DSSD – Si, 300 mkm, 1.85 mm pitch, 59.5x59.5 mm**2. CsI(Tl)/PD, 20x20(front)23x23(back)x100mm**3. Produced by St.Gobain, Khar’kov and China Companies PD.

Slides:



Advertisements
Similar presentations
Detector Characterisation Group
Advertisements

NLC – The Next Linear Collider Project Colorado Univ. - Boulder Calorimetry Cornell-ALCPG Calorimetry Detector Study Plans at Colorado Uriel Nauenberg.
Hybrid Detector Array ( ) The RIKEN-ATOMKI hybrid array Gábor Kalinka (ATOMKI, Debrecen) 3rd Japan-Hungary Joint Seminar on Physics in Modern Science.
W. Clarida, HCAL Meeting, Fermilab Oct. 06 Quartz Plate Calorimeter Prototype Geant4 Simulation Progress W. Clarida The University of Iowa.
ECAL Spike Plot Approval ECAL Anomalous Signal Plots Approval Adi Bornheim for ECAL
Prototype of the Daya Bay Neutrino Detector Wang Zhimin IHEP, Daya Bay.
Geant4 simulations for the calorimeter prototypes D. Di Julio, J. Cederkäll, P. Golubev, B. Jakobsson Lund University, Lund, Sweden.
Proton test facilities Uppsala, TSL, GWC, B-line (Blue hall): Energy ±0.80 MeV. Flux reduced from normal 2·10 8 s -1 to 900 s -1 with a profile as.
Geant4 simulations for the calorimeter prototypes D. Di Julio, J. Cederkäll, P. Golubev, B. Jakobsson Lund University, Lund, Sweden.
Tests of scintillators CsI, CsI(Na), BGO, NaI(Tl) CsI(Tl)
ipno.in2p3.fr Milano - October 2006IPNO-RDD-Jean Peyré1 Measurements of CsI(Tl) Crystals with PMT and APD Jean Peyré Milano - Oct 2006.
1 A Design of PET detector using Microchannel Plate PMT with Transmission Line Readout Heejong Kim 1, Chien-Min Kao 1, Chin-Tu Chen 1, Jean-Francois Genat.
GEM DHCAL Simulation Studies J. Yu* Univ. of Texas at Arlington ALCW, July 15, 2003 Cornell University (*on behalf of the UTA team; S. Habib, V. Kaushik,
R&D on CsI(Tl) + APD Optimisation of the energy resolution M. Gascón I.Durán.
Crystals !? R3B/EXL meeting Milan Oct-06. Crystal growing factories Quality and price on 20(23)*20(23)*110 mm 3 detector light output uniformity* price.
Ionization. Measuring Ions A beam of charged particles will ionize gas. –Particle energy E –Chamber area A An applied field will cause ions and electrons.
GEANT4 simulations for the Lund R 3 B prototype Douglas Di Julio Lund University, Lund, Sweden.
Nustar/crystal simulations B. Genolini Crystal: CsI(Tl) (Saint Gobain), wrapped with reflector (VM2000, Tyveck?) Geometry:
Especially concerning optimization of identification power, energy resolution, efficiency, optimal readout device for the barrel part of CALIFA, a calorimeter.
What the Lund/Dubna group wishes to achieve until next annual meeting produce two* close-to-final (forward) EGPA clusters requiresCsI(Tl) decided (alternatives?,doping.
B. Jakobsson, CWG meeting, June 18-19, 2007: Intoductory slide
ipno.in2p3.fr Orsay - October 2007IPNO-RDD-Jean Peyré1 Test Protocole for Crystals with Gamma Sources Jean Peyré Oct 2007.
ipno.in2p3.fr Lund - June 2007IPNO-RDD-Jean Peyré1 Measurements of some Crystals with PMT R&D on Calorimeters Jean Peyré Lund - June 2007.
Gamma Spectroscopy HPT TVAN Technical Training
Charge collection studies on heavily diodes from RD50 multiplication run G. Kramberger, V. Cindro, I. Mandić, M. Mikuž Ϯ, M. Milovanović, M. Zavrtanik.
Realistic requirements from R 3 B program  In-beam tests of Demonstrators (no TRD yet) Decisions on: Readout device, Forward cap detectors (  Detector.
The Transverse detector is made of an array of 256 scintillating fibers coupled to Avalanche PhotoDiodes (APD). The small size of the fibers (5X5mm) results.
EXL/crystal simulations B. Genolini Simulation of NUSTAR crystals with Litrani Presentation of Litrani: simulation of.
Report on SiPM Tests SiPM as a alternative photo detector to replace PMT. Qauntify basic characteristics Measure Energy, Timing resolution Develop simulation.
The Design of Barrel Electromagnetic Calorimeter (BEMC) October Lu Jun-guang.
St. Petersburg State University. Department of Physics. Division of Computational Physics. COMPUTER SIMULATION OF CURRENT PRODUCED BY PULSE OF HARD RADIATION.
1 Alessandra Casale Università degli Studi di Genova INFN Sezione Genova FT-Cal Prototype Simulations.
SuperNEMO Simulations Darren Price University of Manchester July, 2005.
NEW COMMENTS TO ILC BEAM ENERGY MEASUREMENTS BASED ON SYNCHROTRON RADIATION FROM MAGNETIC SPECTROMETER E.Syresin, B. Zalikhanov-DLNP, JINR R. Makarov-MSU.
Light Output Uniformity of Long CsI(Tl) crystals - the “bottle-neck” for gamma and proton spectroscopy Light Output Uniformity for CsI(Tl) as supplied.
Setup for hypernuclear gamma-ray spectroscopy at J-PARC K.Shirotori Tohoku Univ. Japan for the Hyperball-J collaboration J-PARC E13 hypernuclear  -ray.
LRT2004 Sudbury, December 2004Igor G. Irastorza, CEA Saclay NOSTOS: a spherical TPC to detect low energy neutrinos Igor G. Irastorza CEA/Saclay NOSTOS.
The High Resolution Array The High Resolution Array is a detector designed to detect and identify light charged particles like protons, deuterium, triton,
Photodetection EDIT Internal photoelectric effect in Si Band gap (T=300K) = 1.12 eV (~1100 nm) More than 1 photoelectron can be created by light in silicon.
Montpellier, November 15, 2003 J. Cvach, TileHCAL and APD readout1 TileHCAL- fibre readout by APD APDs and preamplifiers Energy scan with DESY beam –Energy.
1 Report on analysis of PoGO Beam Test at Spring-8 Tsunefumi Mizuno July 15, 2003 July 21, 2003 revised August 1, 2003 updated.
Simulation of the energy response of  rays in CsI crystal arrays Thomas ZERGUERRAS EXL-R3B Collaboration Meeting, Orsay (France), 02/02/ /03/2006.
8 th Aug 2009 ANL User Workshop Towards Nuclear Spectroscopy using a Position Sensitive Avalanche Photo Diode S. Lakshmi University of Massachusetts Lowell.
Experimental Nuclear Physics Some Recent Activities 1.Development of a detector for low-energy neutrons a. Hardware -- A Novel Design Idea b. Measure the.
Jyly 8, 2009, 3rd open meeting of Belle II collaboration, KEK1 Charles University Prague Zdeněk Doležal for the DEPFET beam test group 3rd Open Meeting.
Gain stability and the LYSO beam radiation monitor measurements
WIMP search Result from KIMS experiments Kim Seung Cheon (DMRC,SNU)
? At Yangyang beach, looking for something in the swamp of particles and waves. 1 The recent results from KIMS Seung Cheon Kim (Seoul National University)
00 Cooler CSB Direct or Extra Photons in d+d  0 Andrew Bacher for the CSB Cooler Collaboration ECT Trento, June 2005.
Geant4 Tutorial, Oct28 th 2003V. Daniel Elvira Geant4 Simulation of the CMS 2002 Hcal Test Beam V. Daniel Elvira Geant4 Tutorial.
HMPiD upgrade variant; simulation status N. Smirnov Physics Department, Yale University, May, 06. CERN visit.
CALICE, CERN June 29, 2004J. Zálešák, APDs for tileHCAL1 APDs for tileHCAL MiniCal studies with APDs in e-test beam J. Zálešák, Prague with different preamplifiers.
MEG 実験 2009 液体キセノン検出器の性能 II 西村康宏, 他 MEG コラボレーション 東京大学素粒子物理国際研究セン ター 第 65 回年次大会 岡山大学.
Testbeam analysis Lesya Shchutska. 2 beam telescope ECAL trigger  Prototype: short bars (3×7.35×114 mm 3 ), W absorber, 21 layer, 18 X 0  Readout: Signal.
WP 22 – SciFi Development and Characterisation of Inorganic Scintillating Fibers Made of LuAG:Ce and LYSO:Ce S. Diehl 1, R. Novotny 1, Aubry Nicolas 2.
CALIFA - USC R&D activities: Designing and prototyping CALIFA a next generation calorimeter for R3B/FAIR Huelva July 07.
Optimization of Scintillators for Stacked-layer Detectors of FNGR 1,2 Jea Hyung Cho, 1,2 Kwang Hyun Kim *, and 3 Young Hyun Jung 1 Biomedical Engineering,
Hybrid Detector(s) for Complete Gamma Ray Spectroscopy S. S. Bhattacharjee, R Raut, S S Ghugre, A K Sinha UGC-DAE Consortium For Scientific Research, Kolkata.
Manoj B. Jadhav Supervisor Prof. Raghava Varma I.I.T. Bombay PANDA Collaboration Meeting, PARIS – September 11, 2012.
The Status of Hyperball-J Akio Sasaki Dept. of Phys. Tohoku Univ. 23/9/2011.
Prospect of SiPM application to TOF in PANDA
Idee per lo sviluppo del Charge Identifier
Ultra fast SF57 based SAC M. Raggi Sapienza Università di Roma
The Lund R3B prototype: In-beam proton tests and simulations
Comparison of GAMMA-400 and Fermi-LAT telescopes
GLAST LAT tracker signal simulation and trigger timing study
SIGMA: a detector for γ-ray spectroscopy & imaging Dr Laura AGATA/GRETINA Collaboration Meeting
MCP PET Simulation (7) – Pixelated X-tal
HE instrument and in-orbit performance
Implantation detector as active stopper Rakesh Kumar, P. Doornenbal, I
Presentation transcript:

DSSD – Si, 300 mkm, 1.85 mm pitch, 59.5x59.5 mm**2. CsI(Tl)/PD, 20x20(front)23x23(back)x100mm**3. Produced by St.Gobain, Khar’kov and China Companies PD – 10.5x11.5x0.300 mm**3. Light guide /CsI(Tl)/ to fit PD active area Lund, V.Avdeichikov DSSD Module of 9 (3x3) CsI(Tl) elements, 20x20x100 mm**3 Photo Diodes CsI(Tl) Demonstrator (3x3 module) In-Beam and Bench Tests. Problems and Solutions (Lund- Dubna CWG, presented by V.Avdeichikov)

CsI(Tl) scintillators, the PD’s, APD’s and Double Sided Strip Detector

CsI(Tl) Demonstrator (3x3 module) In-Beam and Bench Tests. Problems and Solutions (Lund- Dubna CWG, presented by V.Avdeichikov) 1.Structure of the Si + CsI(Tl) element a) Requirements on CsI(Tl) - geometry – 20x20 (front), 23x23 (back), L=100 (200) mm; with or w/o tail - Tl concentration ( c = 0.07 mol%),  c <0.7% - surface treatment / mirror/ - light collection uniformity – as best as possible ( for each crystal) 2. Suppliers and Prices - Shanghai SICCAS High Technology Corporation (20x20/23x23x100 mm**3) - AMCRYS Ltd, Khar’kov (20x20/23/23x100, 20x20/23x23x200) - St Gobain CRYSTALS ( 20x20/23x23 x100) 3.Bench tests / gammas, alphas/ - wrapping material – Al foil, Tyvek paper, VM2000 ( Vikuit ESR) - light collection - efficiency of light collection 10x10x10 -  20x20x100 mm**2 - tests with the PD and APD light readout 4.In-beam tests, protons, 180 MeV - energy resolution - light-energy relations, slope parameter (calibration) - inelastic interaction, multiple scattering - GEANT simulation 5. Some useful info on Scintillators Lund, V.Avdeichikov

Shanghai SICCAS High Technology Corporation: 100 mm, 20*20/23*23 mm 2 (no lightguide) no wrapping US$ 200 € 148 ………………… ” ……………, ESR wrapping (special price?)US$ 200 € 148 AMCRYS Ltd, Kharkov 110 mm, 20*20/23*23 mm 2 (lightguide 11*11 mm 2 ), no wrappingUS$ 172 € mm, 20*20/26*26 mm 2 (lightguide 11*11 mm ), no wrapping US $ 330 € 244 St Gobain CRYSTALS 110 mm, 20*20/23*23 mm 2 (lightguide 11*11 mm 2 ), teflon wrapping, optimized light € 1051 ………………………………. ” …………………………………non-optimized € mm, 20*20/26*26 mm 2 (lightguide 11*11 mm 2 ), wrapping, optimized € 1551 ………………………………. ” …………………………………non-optimized € 916 (at least 25% reduction for big numbers is given) Companies and Prices Lund, V.Avdeichikov

3. Bench tests. Light collection and Light output uniformity Tested rapping materials 1. Al foil… 2. PFTE tape. 2. TYVEK paper/ used by ALICE/PHOS for PWO wrapping… 3. Vikuiti ESR ( Visual Mirror ) – the best, max. uniformity and max. Light Output…Almost 100% reflection!!!! wrapping Ris Fair 011.ps Light Output must be a) as high as possible, b) as uniform as possible along the crystal.  L defines an energy resolution / for gammas and particles / and energy scale linearity!!! Lund, V.Avdeichikov Co60, Cs137 gammas

Bench tests Light collection uniformity Light output uniformity for supplied crystals and gamma spectroscopy measured by the CsI(Tl)/APD /left / and after our improvement in light uniformity / right Fig./. Lund, V.Avdeichikov As suppliedAfter correction

“Focusing phenomenon” – a typical nonuniformity picture for long crystals. Primary ( as measured by Suppliers ) spread of Light Output along the crystal as measured by Cs137 gamma source) - open circles, and after our improvement - filled circles. The method consists in “shadowing” of back facet of crystal near the front face. The loss in Light Output due to the correction of the uniformity – 10 – 15%. Final L.O. spread dL<0.7% Correction of Light output uniformity Lund, V.Avdeichikov

PD is used to calibrate the scale and to define noise level. R% down to 2.8keV is possible ( CMS/PHOS-CERN Preamp.). 10x10x10 mm**2 – an ideal crystal. R%(59.5 keV)=R% (Gen) = R (in keV) for  lines!! Shaping = 3.0 mksec. Light collect. efficiency for 20x20x100 = 60-75% (of 10x10x10), for both shapes, see Fig. Crystals of excellent light uniformity, <0.7%. Lund, V.Avdeichikov Picture2 Loss of light, 10x10x10 mm**3 vs 20x20x100 mm**3 crystal Am, 59 keV

Bench test CsI(Tl)/APD, CsI(Tl)/PD !0x10x10 mm**3 20x20x100 mm**3 Test of crystals of different size with APD (left) and PD ( right) readout. No big difference for gamma energies >0.66 MeV Lund, V.Avdeichikov

In-beam tests Fig 7x7/CsI  Si) -  (CsI(Tl)) method (Cu absorber is used to get second energy point, 93.3 MeV) CsI(Tl) - 9 elements, 20x20(23x23)x100 mm**3 Si – 7x7 mm*2, 310 mk 20x20 mm**2, 529 mkm DSSD – 16x16 strips, 310 mkm Uppsala, GWC, protons, MeV We measured : energy resolution, slope parameter a2, L=a1*exp(a2) +c, inelastic interaction, multiple scattering. Data are taken for central detector Lund, V.Avdeichikov 2

Uppsala, GWC, protons, MeV Energy resolution Energy resolution of CsI(Tl) detectors for protons, MeV. Tl doping for Khar’kov mol% - to get optimal particle identification in pulse shape analysis Compilation of our data on the energy resolution Temperature dependence of Light output for CsI(Tl)/PD + electronic elements is 0.4%/1 C (GLAST Calorimeter data[]) To get an energy resolution on the level <0.4% we need to stabilize the temperature of CsI(Tl) sample on the level better than 1 C Lund, V.Avdeichikov

In-beam tests a2 – slope parameter. Precision in a2 results in final energy resolution of CsI(Tl) as for charged particles, so for gammas !!!! Data from this experiment a2 depends on shaping const, light collection uniformity and ??????? Light-Energy relations. L=a1*exp(a2*E) + c Lund, V.Avdeichikov

In-beam test. Inelastic interactions (and multiple scattering) 20x20x100, CsI Si, 7x7 mm**2 or 60x60 mm**2 DSSD Comparison of the calculations and (our) experimental data of the particle losses due to the inelastic interactions in the CsI crystal. Thick dotted curves are calculations from Glauber model, thin dotted curves – from the complete fusion model. Point marked as big circle is taken from this in-beam test. To extract info about the multiple scattering we need to proceed with data analysis with Double Side Strip Detector Lund, V.Avdeichikov

GEANT simulation Multiple scattering Inelastic interactions Inelastic interaction + multiple scattering CsI(Tl) 40x40x100 mm**3 !!!! Simulation for the geometry of 40x40x100 mm**3 of CsI crystal Excellent coincidence with data !! except of…….shape of the “tail”… 190. MeV Lund, V.Avdeichikov

GEANT simulations The position and fraction of “washed out” events for geometry of 40x40x100 mm**3 CsI crystal. E_p=190 MeV D A B C Lund, V.Avdeichikov Attention to Fig. D !!! Almost 80% detection loss in the region about 3 mm from detector periphery (mostly because of multiple scattering) Gain corrected sum signal in the central crystal of 3x3 PWO detector array ( ALICE)

Energy resolution of the “ideal” CsI scint for gammas defined in great extent by the noise of PD+ Preamp.+ Shaper. Measurement of low-energy (say, less than 660 keV) gammas with quite reasonable resolution by using PD is a almost irresolvable problem… Signal from the PD is only 60 keV for 1.17 MeV gammas!!!!!! Lund, V.Avdeichikov Some useful info on scintillators K_ampl.=50.

Some useful info on scintillators Fig.5. Energy resolution of six different scintillators for alpha- particles from the {226}Ra and {241}Am sources. Solid lines represent power law fits, R(%)=b1*exp(-b2*E) The alpha/gamma ratio - the ratio of the light output of alpha-particle and gamma-rays with equal energies. Data are taken with a 1.5 msec shaping time constant of main amplifier. Solid lines are drawn to guide an eye. Lund, V.Avdeichikov

We need: 1. GEANT simulation for given geometry 2. To analyze the multiple scattering 3. To prepare gamma tests?? CsI(Tl), 20x20(23x23)x100 mm**3 Module of 3x3 samles