Radial Velocity Detection of Planets: I. Techniques 1. Keplerian Orbits 2. Spectrographs/Doppler shifts 3. Precise Radial Velocity measurements.

Slides:



Advertisements
Similar presentations
Lecture 5 Binary stars.
Advertisements

BINARIES - Key to Comprehension of the Universe, Brno, Czech Republic, June 8-12, 2009 Selim O. SELAM Mesut YILMAZ Ankara University Observatory Hideyuki.
The Detection and Properties of Planetary Systems
Chapter 5 Telescopes. 5.1 Optical Telescopes The Hubble Space Telescope 5.2 Telescope Size The Hubble Space Telescope 5.3 Images and Detectors Diffraction.
Dr Matt Burleigh The Sun and the Stars. Dr Matt Burleigh The Sun and the Stars Binary stars: Most stars are found in binary or multiple systems. Binary.
WHY STUDY ASTROPHYSICS?  To gain an understanding of our universe and our role in it Learn about how the universe operates --> modern science  Observations.
Spectral Resolution and Spectrometers
Echelle Spectroscopy Dr Ray Stathakis, AAO. What is it? n Echelle spectroscopy is used to observe single objects at high spectral detail. n The spectrum.
Spectral Resolution and Spectrometers A Brief Guide to Understanding and Obtaining the Proper Resolution of the 785 Raman System.
Stellar Continua How do we measure stellar continua? How precisely can we measure them? What are the units? What can we learn from the continuum? –Temperature.
The Origin of Modern Astronomy Chapter 4:. Isaac Newton 1689.
Universe Eighth Edition Universe Roger A. Freedman William J. Kaufmann III CHAPTER 17 The Nature of Stars CHAPTER 17 The Nature of Stars.
The Properties of Stars Masses. Using Newton’s Law of Gravity to Determine the Mass of a Celestial Body Newton’s law of gravity, combined with his laws.
Detection of Terrestrial Extra-Solar Planets via Gravitational Microlensing David Bennett University of Notre Dame.
Astronomy190 - Topics in Astronomy Astronomy and Astrobiology Lecture 19 : Extrasolar Planets Ty Robinson.
Spectrographs. Spectral Resolution d 1 2 Consider two monochromatic beams They will just be resolved when they have a wavelength separation of d Resolving.
Astronomical Spectroscopy
Properties of Stars. Distance Luminosity (intrinsic brightness) Temperature (at the surface) Radius Mass.
CEE 540 Spring Term 2012 go over syllabus and course requirements project spectra lab demo: parts of a spectrograph image in focal plane hg spectral emission.
Rotational Motion and The Law of Gravity
Spring School of Spectroscopic Data Analyses 8-12 April 2013 Astronomical Institute of the University of Wroclaw Wroclaw, Poland.
Astronomical Instrumentation Often, astronomers use additional optics between the telescope optics and their detectors. This is called the instrumentation.
The mass ratio of the stellar components of a spectroscopic binary can be directly computed from their ratio in radial velocities. To derive the total.
Observational Methods 1.Spectroscopy 2.Photometry Prof. Dr. Artie Hatzes > Lehre -> Jena.
AST 111 Exoplanets I.
Extrasolar planets. Detection methods 1.Pulsar timing 2.Astrometric wobble 3.Radial velocities 4.Gravitational lensing 5.Transits 6.Dust disks 7.Direct.
Spectrographs. Literature: Astronomical Optics, Daniel Schneider Astronomical Observations, Gordon Walker Stellar Photospheres, David Gray.
Radiation Kirchoff’s Laws  Light emitted by a blackbody, a hot opaque body, or hot dense gas produces a continuous spectrum  A hot transparent gas produces.
The Doppler Method, or Radial Velocity Detection of Planets: I. Technique 1. Keplerian Orbits 2. Spectrographs/Doppler shifts 3. Precise Radial Velocity.
14 October Observational Astronomy SPECTROSCOPY and spectrometers Kitchin, pp
Precision Doppler spectroscopy Guillem Anglada-Escude School of Physics and Astronomy Queen Mary, University of London Institute for Astrophysics Georg-August-Universität.
1B11 Foundations of Astronomy Orbits Liz Puchnarewicz
CHAPTER 4: Visible Light and Other Electromagnetic Radiation.
1 II-6 Stellar Mass and Binary Stars (Main Ref.: Lecture notes; FK Sec.4 - 4, 6, 7; 17-9, 10, and 11, Box 4-2, 4-4) II-6a. Introduction If the star is.
18 October Observational Astronomy SPECTROSCOPY and spectrometers Kitchin, pp
Spectrographs. Literature: Astronomical Optics, Daniel Schroeder Astronomical Observations, Gordon Walker Stellar Photospheres, David Gray.
Astronomical Spectroscopy Notes from Richard Gray, Appalachian State, and D. J. Schroeder 1974 in “Methods of Experimental Physics, Vol. 12-Part A Optical.
AST 443/PHY 517 : Observational Techniques November 6, 2007 ASTROMETRY By: Jackie Faherty.
Physical properties. Review Question What are the three ways we have of determining a stars temperature?
Stars: Binary Systems. Binary star systems allow the determination of stellar masses. The orbital velocity of stars in a binary system reflect the stellar.
Radial Velocity Detection of Planets: I. Techniques and Tools 1. Keplerian Orbits 2. Spectrographs/Doppler shifts 3. Precise Radial Velocity measurements.
Chapter 7 Rotational Motion and The Law of Gravity.
The Search for Extra-Solar Planets Dr Martin Hendry Dept of Physics and Astronomy.
Astronomy The study of objects and matter outside the earth's atmosphere and of their physical and chemical properties.
Extrasolar planets. Detection methods 1.Pulsar Timing Pulsars are rapidly rotating neutron stars, with extremely regular periods Anomalies in these periods.
Radial Velocity Detection of Planets: I. Techniques and Tools 1. Keplerian Orbits 2. Spectrographs/Doppler shifts 3. Precise Radial Velocity measurements.
Extrasolar Planets Is there a twin of our Home Planetsomewhere out there? Gero Rupprecht, ESO Brandys,
MOS Data Reduction Michael Balogh University of Durham.
Practical applications: CCD spectroscopy Tracing path of 2-d spectrum across detector –Measuring position of spectrum on detector –Fitting a polynomial.
AS 3004 Stellar Dynamics Energy of Orbit Energy of orbit is E = T+W; (KE + PE) –where V is the speed in the relative orbit Hence the total Energy is is.
Radial Velocity Detection of Planets: I. Techniques 1. Keplerian Orbits 2.Spectrographs/Doppler shifts 3. Precise Radial Velocity measurements Contact:
Stars come in all sizes, small, large and even larger.
Eva Meyer MPIA-Student-Workshop, Italy Various information from different detection methods.
Spectrographs. Literature: Astronomical Optics, Daniel Schroeder Astronomical Observations, Gordon Walker Stellar Photospheres, David Gray.
Lect. 5, gratings&light, CAPSTONE Lecture 5: Radiation from atoms.
Can we find Earth-mass habitable planets orbiting our nearest star, α Centauri? John Hearnshaw, Dept. of Physics and Astronomy University of Canterbury.
14 January Observational Astronomy SPECTROSCOPIC data reduction Piskunov & Valenti 2002, A&A 385, 1095.
Lecture 13 Light: the Cosmic Messenger Telescopes and Observational Astronomy.
The Orbits, Sizes, Rotations, Velocities, and Trajectories of our Local Planets and of our Star Chase Nordquist MUSIC OF THE SPHERES.
Atmospheric extinction Suppose that Earth’s atmosphere has mass absorption coefficient  at wavelength. If f 0 is flux of incoming beam above atmosphere,
Properties of Stars. "There are countless suns and countless earths all rotating around their suns in exactly the same way as the seven planets of our.
The Detection and Properties of Planetary Systems Prof. Dr. Artie Hatzes.
F. Pepe Observatoire de Genève Optical astronomical spectroscopy at the VLT (Part 2)
Chapter 7 Rotational Motion and The Law of Gravity.
Orbits and Masses of Stars Types of Binary Stars Visual Binaries Spectroscopic Binaries/Doppler Effect Eclipsing Binary Stars Main Sequence/Mass-Luminosity.
Hunting for exoplanets around K giants
Introduction to Spectroscopy
Instrument Considerations
Spectroscopy Workshop
Presentation transcript:

Radial Velocity Detection of Planets: I. Techniques 1. Keplerian Orbits 2. Spectrographs/Doppler shifts 3. Precise Radial Velocity measurements

apap asas V P 2 = 4242 (a s + a p ) 3 G(m s + m p ) msms mpmp Newton‘s form of Kepler‘s Law

P 2 = 4242 (a s + a p ) 3 G(m s + m p ) Approximations: a p » a s m s » m p P2 ≈P2 ≈ 4242 ap3ap3 Gm s

Circular orbits: V = 2as2as P Conservation of momentum: m s × a s = m p × a p a s = m p a p msms Solve Kepler‘s law for a p : a p = P 2 Gm s 4242 () 1/3 … and insert in expression for a s and then V for circular orbits

V = 22 P(4  2 ) 1/3 m p P 2/3 G 1/3 m s 1/3 V = P 1/3 m s 2/3 mpmp = 28.4 P 1/3 m s 2/3 mpmp m p in Jupiter masses m s in solar masses P in years V in m/s 28.4 P 1/3 m s 2/3 m p sin i V obs =

PlanetMass (M J )V(m s –1 ) Mercury1.74 × 10 – Venus2.56 × 10 – Earth3.15 × 10 – Mars3.38 × 10 – Jupiter Saturn Uranus Neptune Pluto1.74 × 10 –4 3×10 –5 Radial Velocity Amplitude of Sun due to Planets in the Solar System

Radial Velocity Amplitude of Planets at Different a Radial Velocity (m/s) G2 V star

Radial Velocity (m/s) A0 V star

M2 V star

eccentricity Elliptical Orbits = OF1/a O

 : angle between Vernal equinox and angle of ascending node direction (orientation of orbit in sky) i: orbital inclination (unknown and cannot be determined P: period of orbit  : orientation of periastron e: eccentricity M or T: Epoch K: velocity amplitude Important for radial velocities Not important for radial velocities

Radial velocity shape as a function of eccentricity:

Radial velocity shape as a function of , e = 0.7 :

Eccentric orbit can sometimes escape detection: With poor sampling this star would be considered constant

Eccentricities of bodies in the Solar System

Important for orbital solutions: The Mass Function f(m) = (m p sin i) 3 (m p + m s ) 2 = P 2G2G K 3 (1 – e 2 ) 3/2 P = period K = Amplitude m p = mass of planet (companion) m s = mass of star e = eccentricity

Observer Because you measure the radial component of the velocity you cannot be sure you are detecting a low mass object viewed almost in the orbital plane, or a high mass object viewed perpendicular to the orbital plane We only measure M Planet x sin i i

The orbital inclination We only measure m sin i, a lower limit to the mass. What is the average inclination? i The probability that a given axial orientation is proportional to the fraction of a celestrial sphere the axis can point to while maintaining the same inclination P(i) di = 2  sin i di

The orbital inclination P(i) di = 2  sin i di Mean inclination: =  ∫ P(i) sin i di 0  ∫ P(i) di 0 =  /4 = 0.79 Mean inclination is 52 degrees and you measure 80% of the true mass

The orbital inclination P(i) di = 2  sin i di But for the mass function sin 3 i is what is important : =  ∫ P(i) sin 3 i di 0  ∫ P(i) di 0 =  ∫ sin 4 i di  0 = 3  /16 = 0.59

The orbital inclination P(i) di = 2  sin i di Probability i <  : P(i<  ) =  ∫ P(i) di 0  ∫ 0 2 (1 – cos  ) =  < 10 deg : P= 0.03 (sin i = 0.17)

Measurement of Doppler Shifts In the non-relativistic case: – 0 0 = vv c We measure  v by measuring 

The Radial Velocity Measurement Error with Time How did we accomplish this?

The Answer: 1. Electronic Detectors (CCDs) 2. Large wavelength Coverage Spectrographs 3. Simultanous Wavelength Calibration (minimize instrumental effects)

Instrumentation for Doppler Measurements High Resolution Spectrographs with Large Wavelength Coverage

collimator Echelle Spectrographs slit camera detector corrector From telescope Cross disperser

A spectrograph is just a camera which produces an image of the slit at the detector. The dispersing element produces images as a function of wavelength without disperser with disperser slit

5000 A 4000 A n = – A 4000 A n = – A 5000 A n = A 5000 A n = 1 Most of light is in n=0

These are the instensity distribution of the first 3 orders of a reflection grating

3000 m= m= m= Schematic: orders separated in the vertical direction for clarity 1200 gr/mm grating 2 1 You want to observe 1 in order m=1, but light 2 at order m=2, where 1 ≠ 2 contaminates your spectra Order blocking filters must be used

4000 m=99 m=100 m= Schematic: orders separated in the vertical direction for clarity 79 gr/mm grating Need interference blocking filter but why throw away light? In reality:

yy ∞ 2 y m-2 m-1 m m+2 m+3   Free Spectral Range  m Grating cross-dispersed echelle spectrographs

On a detector we only measure x- and y- positions, there is no information about wavelength. For this we need a calibration source y x

CCD detectors only give you x- and y- position. A doppler shift of spectral lines will appear as  x  x →  →  v How large is  x ?

Spectral Resolution d 1 2 Consider two monochromatic beams They will just be resolved when they have a wavelength separation of d Resolving power: d = full width of half maximum of calibration lamp emission lines R = d ← 2 detector pixels

R = →  = 0.11 Angstroms → Angstroms / pixel (2 pixel 5500 Ang. 1 pixel typically 15  m 1 pixel = Ang → x (310 8 m/s)/5500 Ang → = 3000 m/s per pixel = v  c  v = 10 m/s = 1/300 pixel = 0.05  m = 5 x 10 –6 cm  v = 1 m/s = 1/1000 pixel → 5 x 10 –7 cm

RAng/pixelVelocity per pixel (m/s)  pixel Shift in mm ×10 – ×10 – – ×10 – ×10 – ×10 –4 10 – ×10 –4 2×10 –6 So, one should use high resolution spectrographs….up to a point For  v = 20 m/s How does the RV precision depend on the properties of your spectrograph?

Wavelength coverage: Each spectral line gives a measurement of the Doppler shift The more lines, the more accurate the measurement:  Nlines =  1line /√N lines → Need broad wavelength coverage Wavelength coverage is inversely proportional to R:  detector Low resolution High resolution 

Noise:  Signal to noise ratio S/N = I/  I For photon statistics:  = √I → S/N = √I I = detected photons Note: recall that if two stars have magnitudes m 1 and m 2, their brightness ratio is  B = (m 1 – m 2 )

 (S/N) –1 Price: S/N  t 2 exposure 14 Exposure factor S/N  t 2 exposure

How does the radial velocity precision depend on all parameters?  (m/s) = Constant × (S/N) –1 R –3/2 (  ) –1/2  : error R: spectral resolving power S/N: signal to noise ratio  : wavelength coverage of spectrograph in Angstroms For R= , S/N=150,  =2000 Å,  = 2 m/s C ≈ 2.4 × 10 11

The Radial Velocity precision depends not only on the properties of the spectrograph but also on the properties of the star. Good RV precision → cool stars of spectral type later than F6 Poor RV precision → hot stars of spectral type earlier than F6 Why?

A7 star K0 star Early-type stars have few spectral lines (high effective temperatures) and high rotation rates.

A0 A5 F0 F5 RV Error (m/s) G0G5 K0 K5 M0 Spectral Type Main Sequence Stars Ideal for 3m class tel. Too faint (8m class tel.). Poor precision 98% of known exoplanets are found around stars with spectral types later than F6

Including dependence on stellar parameters v sin i : projected rotational velocity of star in km/s f(T eff ) = factor taking into account line density f(T eff ) ≈ 1 for solar type star f(T eff ) ≈ 3 for A-type star f(T eff ) ≈ 0.5 for M-type star  (m/s) ≈ Constant ×(S/N) –1 R –3/2 v sin i ( 2 ) f(T eff ) (  ) –1/2

Eliminate Instrumental Shifts Recall that on a spectrograph we only measure a Doppler shift in  x (pixels). This has to be converted into a wavelength to get the radial velocity shift. Instrumental shifts (shifts of the detector and/or optics) can introduce „Doppler shifts“ larger than the ones due to the stellar motion z.B. for TLS spectrograph with R= our best RV precision is 1.8 m/s → 1.2 x 10 –6 cm

Traditional method: Observe your star→ Then your calibration source→

Problem: these are not taken at the same time…... Short term shifts of the spectrograph can limit precision to several hunrdreds of m/s

Solution 1: Observe your calibration source (Th-Ar) simultaneously to your data: Spectrographs: CORALIE, ELODIE, HARPS Stellar spectrum Thorium-Argon calibration

Advantages of simultaneous Th-Ar calibration: Large wavelength coverage (2000 – 3000 Å) Computationally simple: cross correlation Disadvantages of simultaneous Th-Ar calibration: Th-Ar are active devices (need to apply a voltage) Lamps change with time Th-Ar calibration not on the same region of the detector as the stellar spectrum Some contamination that is difficult to model Cannot model the instrumental profile, therefore you have to stablize the spectrograph

One Problem: Th-Ar lamps change with time!

Solution 2: Absorption cell a) Griffin and Griffin: Use the Earth‘s atmosphere:

O2O Angstroms

Filled circles are data taken at McDonald Observatory using the telluric lines at 6300 Ang. Example: The companion to HD using the telluric method. Best precision is 15–30 m/s

Limitations of the telluric technique: Limited wavelength range (≈ 10s Angstroms) Pressure, temperature variations in the Earth‘s atmosphere Winds Line depths of telluric lines vary with air mass Cannot observe a star without telluric lines which is needed in the reduction process.

Absorption lines of the star Absorption lines of cellAbsorption lines of star + cell b) Use a „controlled“ absorption cell

Campbell & Walker: Hydrogen Fluoride cell: Demonstrated radial velocity precision of 13 m s –1 in 1980!

Drawbacks: Limited wavelength range (≈ 100 Ang.) Temperature stablized at 100 C Long path length (1m) Has to be refilled after every observing run Dangerous

A better idea: Iodine cell (first proposed by Beckers in 1979 for solar studies) Advantages over HF: 1000 Angstroms of coverage Stablized at 50–75 C Short path length (≈ 10 cm) Can model instrumental profile Cell is always sealed and used for >10 years If cell breaks you will not die! Spectrum of iodine

Spectrum of star through Iodine cell:

The iodine cell used at the CES spectrograph at La Silla

Modelling the Instrumental Profile: The Advantage of Iodine What is an instrumental profile (IP): Consider a monochromatic beam of light (delta function) Perfect spectrograph

Modelling the Instrumental Profile (IP) We do not live in a perfect world: A real spectrograph IP is usually a Gaussian that has a width of 2 detector pixels The IP is a „smoothing“ or „blurring“ function caused by your instrument

Convolution  f(u)  (x–u)du = f *  f(x):  (x):

Convolution  (x-u) a1a1 a2a2 g(x) a3a3 a2a2 a3a3 a1a1 Convolution is a smoothing function. In our case f(x) is the stellar spectrum and  (x) is our instrumental profile.

The IP is not so much the problem as changes in the IP No problem with this IP Or this IP Unless it turns into this Shift of centroid will appear as a velocity shift

Use a high resolution spectrum of iodine to model IP Iodine observed with RV instrument Iodine Observed with a Fourier Transform Spectrometer

FTS spectrum rebinned to sampling of RV instrument FTS spectrum convolved with calculated IP Observed I 2

Model IP Gaussians contributing to IP IP =  g i Sampling in Data space Sampling in IP space = 5×Data space sampling

Instrumental Profile Changes in ESO‘s CES spectrograph 2 March Jan 1995

Instrumental Profile Changes in ESO‘s CES spectrograph over 5 years:

Mathematically you solve this equation: I obs ( ) = k[T I2 ( )I s ( +  )]*IP Where: I obs ( ) : observed spectrum T I2 : iodine transmission function k: normalizing factor I s ( ): Deconvolved stellar spectrum without iodine and with IP removed IP: Instrumental Point Spread Function Problem: IP varies across the detector. Solve this equation iteratively

Modeling the Instrumental Profile In each chunk: Remove continuum slope in data : 2 parameters Calculate dispersion (Å/pixel): 3 parameters (2 order polynomial: a0, a1, a2) Calculate IP with 5 Gaussians: 9 parameters: 5 widths, 4 amplitudes (position and widths of satellite Gaussians fixed) Calculate Radial Velocity: 1 parameters Combine with high resolution iodine spectrum and stellar spectrum without iodine Iterate until model spectrum fits the observed spectrum

Sample fit to an observed chunk of data

Sample IP from one order of a spectrum taken at TLS But why is the IP double peaked?

Recall that at the detector we have an image of a slit. The slit is square shape and this is convolved with a Gaussian emission line profile, in other words they should have a flat top The modeling uses a sum of Gaussians and the only way to mimic a flat top is with two Gaussians. The IP function is oversampled, when you rebin to 2 pixels of „real detector“ space, one no longer sees the dip in the middle and the IP is square topped. 2 detector pixels

WITH TREATMENT OF IP-ASYMMETRIES

HARPS Simultaneous ThAr cannot model the IP. One has to stabilize the entire spectrograph

Valenti, Butler, and Marcy, 1995, PASP, 107, 966, „Determining Spectrometer Instrumental Profiles Using FTS Reference Spectra“ Butler, R. P.; Marcy, G. W.; Williams, E.; McCarthy, C.; Dosanjh, P.; Vogt, S. S., 1996, PASP, 108, 500, „Attaining Doppler Precision of 3 m/s“ Endl, Kürster, Els, 2000, Astronomy and Astrophysics, “The planet search program at the ESO Coudé Echelle spectrometer. I. Data modeling technique and radial velocity precision tests“ Additional information on RV modeling:

Barycentric Correction Earth’s orbital motion can contribute ± 30 km/s (maximum) Earth’s rotation can contribute ± 460 m/s (maximum)

Needed for Correct Barycentric Corrections: Accurate coordinates of observatory Distance of observatory to Earth‘s center (altitude) Accurate position of stars, including proper motion:   ′  ′ Worst case Scenario: Barnard‘s star Most programs use the JPL Ephemeris which provides barycentric corrections to a few cm/s

For highest precision an exposure meter is required time Photons from star Mid-point of exposure No clouds time Photons from star Centroid of intensity w/clouds Clouds

Differential Earth Velocity: Causes „smearing“ of spectral lines Keep exposure times < min