Nanotechnology Metal Oxide Semiconductor (NTMOS) H2S Gas Sensor

Slides:



Advertisements
Similar presentations
Gas Detection Instruments
Advertisements

Copyright© 2014 Austin Analytics Group, LLC. Stand Alone System High Temperature System Hazardous Area System Universal/Remote Display System Copyright©
Gas Detection Strategies Overview of Selection Criteria for Gas Detection Systems.
Open-Path Gas Detection - Philosophy of Use or The Story of Clouds.
… for Combustible Gas Detection S4000C Intelligent Sensors..
Sensor Operating Theory
Load Cell &DP Cell 2007-CHEM-17.
1 Kraft Fuels LPG Products & Services Your Logo Here Franz Keiling An Overview about LPG Dispensers and Technology Franz Keiling An Overview about LPG.
Preferred Utilities Manufacturing Corp South Street Danbury CT Fuel Oil Handling Systems Tank Gauges and Leak Detection.
Hazmat Industry Technician. Types of Equipment Monitoring equipment Detection devices Air sampling systems.
Dr C Narain Spantech Products, South Godstone, Surrey, UK The exclusive representative for ACD in Europe, Middle East and India.
Product Line Overview Company Overview  Incorporated in 1983  Developed and patented first Electronic Cylinder Scale – Model.
Company Confidential © 2005 All Rights Reserved. What is it? State-of-the-art: microprocessor-based, wall-mount gas monitor Easy installation and operation:
Semiconductor Input Devices
E VERY L IFE H AS A P URPOSE… Flame Detection Theory.
E VERY L IFE H AS A P URPOSE… Ultima ® MOS-5 Hydrogen Sulfide Intelligent Sensor E VERY L IFE H AS A P URPOSE… Introduction to a HART Enabled Detector.
THE LATEST DETECTION TOOLS FOR LEAK / ODOR RESPONSE, CARBON MONOXIDE AND CONFINED SPACE ENTRY Paul D. Wehnert Vice President – Sales & Marketing Heath.
E VERY L IFE H AS A P URPOSE… FlameGard 5 UV/IR Flame Detector The Benefits of HART on Installation and Maintenance of Flame Detectors.
1 Engine Protector Safe Rider Vehicle Technologies (Pty) Ltd PO Box 11376, Rynfield South Africa Tel./ fax Cell:
Air Monitoring Presented By: Etech Environmental & Safety Solutions, Inc.
GST FIRE ALARM SYSTEM INTERNATIONAL BUSINESS DEPARTMENT , GST BEIJING
Air Quality Division Tank Degassing and Cleaning Rules; TSH :May 15, 2008 Page 1 Changes to Tank Degassing and Cleaning Rules Texas Association of Environmental.
The EX100 & EX1000 Oil in Water Monitors. The EX100/1000 Oil In Water Monitor Features 1.Continuous Flow and Accurate Measurement. 2.Measurement range.
Gas Sensor and Transmitter
Designing for the Alternative Energy market CONFIDENTIAL: All contents copyright of Illinois Tool Works, Inc. (ITW). The ITW Photonics Group, Cal Sensors,
Ultima® X Series Gas Monitors
1150-D Burnett Ave. Concord, CA USA (800) (925) Fax: (925) Chemical Monitoring Systems.
The Fumigation Monitor Company Integrated Fumigation Monitoring &Web Based Data Acquisition Methyl Bromide & Alternatives Conference Surabaya, Indonesia.
E VERY L IFE H AS A P URPOSE… ULTIMA ® OPIR-5 Open Path Gas Detector E VERY L IFE H AS A P URPOSE…
E VERY L IFE H AS A P URPOSE… Chillgard ® L Series Refrigerant Monitors.
Iris Range : «Unconventional» conventional detectors.
Ron Helson HART Communication Foundation Austin, TX
Patrick Thornton, SNS/FPE June 9, 2008
HazMat Technician Mod 1 Unit 2 Slide 1 Ohio Hazmat & WMD Technician Module 1 Unit 2 Field Survey Instruments.
E VERY L IFE H AS A P URPOSE… Chillgard ® RT Refrigerant Monitors.
Florida Operations Level Hazardous Materials Training Unit 5.5 MISSION SPECIFIC: Air Monitoring and Sampling.
File Name – Date - Owner of File Welcome! TANK BLANKETING Its Theory and Purpose, The Process and Its Setup.
Smart transmitters.
High Sensitivity Smoke Detection
Providing Cost Effective And Reliable Gas Detection Solutions Since 1975.
Standards Certification Education & Training Publishing Conferences & Exhibits Sensors-Related Standards Development at ISA Charley Robinson ISA Standards.
E VERY L IFE H AS A P URPOSE… Toxgard ® II Gas Monitor.
CPAC May 2005 John Mosher – Honeywell Sensing & Control Sensor Actuator Manager (SAM) Controller Considerations And Specification Identification.
H2S Gas Meter/Detector. Introduction Air monitoring data is useful for: *Assessing the health risks to the public and response workers. *Selecting personal.
© 2006 MSA VaporLab™ 700 Gas Analyzer. © 2006 MSA Product Description  Rack mount, turn-key gas analyzer  Analyzes a complex matrix for trace quantities.
E VERY L IFE H AS A P URPOSE… 9010 / 9020 Controller.
Industrial Pressure Transmitters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers.
ARM Based Gas Leakage Detection System Student Name USN NO Guide Name H.O.D Name Name Of The College & Dept.
New Product Developments World Leaders in Combustion Management Solutions New Products New Products.
E VERY L IFE H AS A P URPOSE… Ultima ® XI Gas Monitor.
Series RHP Temperature and Humidity Transmitter The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential.
“ELMIZ” PJSC was found in 1996 as a results of “Kyiv Radio Plant” restructuring according to the decision of the Cabinet of Ministers of Ukraine. The enterprise.
1150-D Burnett Ave. Concord, CA (800) Fax: (925) WIZARD 4000® Chemical Monitoring System.
Transformer Gas Tester Agenda Application Historical Solutions RKI’s Solution Features & Benefits Marketing.
THIN FILM GAS SENSORS Chemical sensors are important to all aspects of modern life. They Provide information about chemical substances needed by instruments.
TOWARDS A TEST METHOD FOR HYDROGEN SENSOR PERFORMANCE NATHAN D. MARSH AND THOMAS G. CLEARY Fire Research Division, National Institute of Standards and.
AGROFARM WEATHER MONITOR USING LabVIEW. INTRODUCTION Innovation in agriculture field Implementing instrumentation tech. in agricultural field The quantity.
LEAK – MASTER ® MAP SECURE PACKAGING MAP LEAK TESTING A7 start.
Bi-Weekly Safety Meeting November 29, The days of using canaries in mines as primitive gas detectors are long gone..they've been replaced by fixed.
Metal Nanoparticle Hydrogen Sensor
Excavation & Trenching Awareness Plus
Temperature Sensors.
Temperature sensors Temperature is the most often-measured environmental quantity. This might be expected since most physical, electronic, chemical, mechanical,
New Cosmos Electric, Co., Ltd.,
Enclosed Parking Ventilation 1 EK Engineering (India) CO/NO2 detection, Fan Control and automation System E: Mobile:
THUM Adapter Impact on Hazardous Area Classification
Magnetostrictive Liquid Level Transmitter
Pressure Level Sensor OTT PLS
Instrumentation and control
Risk Management Student Powerpoint
Presentation transcript:

Nanotechnology Metal Oxide Semiconductor (NTMOS) H2S Gas Sensor January 2009

New Toxic Gas Detector Functional Flexible Reliable Provides H2S gas detection in extreme temperature and humidity conditions Detects H2S faster and more accurately than traditional Metal Oxide Sensors (MOS) Flexible Can be installed as a stand-alone sensor or combined with a display for local indication Reliable Lasts longer and stays awake more than previous MOS H2S gas sensors Provides accurate and long-lasting operation in extreme climates, as proven through third-party performance testing to the ISA-92.0.01 standard

Engineered and Designed for H2S Detection Linear 4-20 mA Output Proportional to 0-100 ppm H2S Explosion-Proof, Stainless Steel Housing Approved for Class 1 Division 1 Hazardous Areas Onboard Humidity Sensor Provides an Accurate Reading in Extreme Climates Automatic Calibration Line Provides Easy One-person Calibration Automatic Fault Diagnostics Indication via Current Output NTMOS Technology Means Higher Sensitivity and Long- lasting Detection Integrated Temperature Sensor for Compensation

Certified to ANSI/ISA Performance Standard Performance Requirements for Toxic Gas- Detection Instruments: Hydrogen Sulfide ISA–92.0.01: New World Standard for Toxic Gas Detection 2.1 This Standard addresses the details of construction, performance, and testing of portable, mobile, and stationary electrical gas-detection instruments operating at ambient temperatures and pressures used to provide a warning of the presence of toxic gases in air. Instruments used to detect flammable (explosive) concentrations of toxic gas(es) when the LEL exceeds the TLV are excluded.

New World Standard for Toxic Gas Detection 92.0.01 Specification Full Scale Range 10 to 100 ppm H2S 0 to 100 ppm H2S * Temperature Range 14 to 122 °F (–10 to 50 °C) -40 to 149 °F (–40 to 65 °C) * Relative Humidity Range 15 to 90% 15 to 90% * Response Time (Full Scale) T20 < 10 seconds T50 < 30 seconds T20  2 seconds * T50  3 seconds * Accuracy / Linearity 10% of applied gas concentration or 2 ppm 10% of applied gas concentration or 2 ppm * * In accordance with FMID 3033318

Designed for Toxic Gas Applications Designed to be installed where low levels of H2S can be detected to avoid the threat to human beings: Crude Oil Tank Storage Tank farms storing crude oil and H2S require continuous monitoring for gas leaks. In addition to the tanks, common leak sources include pipes and valves, which require sensors. Remote Oil / Gas Well Sites Oil and gas well production sites require H2S protection in and around the site. Common monitoring locations include the well heads, flare stacks, and storage tanks. Oil / Gas Drilling Sites Leaks, such as blowouts in oil drilling applications, are subject to releasing large quantities of H2S gas into areas around the site. Typical gas monitoring locations include the driller stand, bell nipple, shale shaker, and mud tank.

Superior H2S Gas Detection Typical While conventional electrochemical (E-Chem) gas sensors are typically used to detect H2S Gas… …our NTMOS sensors detect H2S faster, are more accurate, and last longer in extreme temperature and humidity applications.

Environmental Effects on Sensor Performance Temperature E-Chem NTMOS Low Med High NTMOS NTMOS NTMOS High E-Chem E-Chem E-Chem No Effect Affects Performance Affects Performance and Sensor Life NTMOS NTMOS NTMOS Humidity Med E-Chem E-Chem E-Chem NTMOS NTMOS NTMOS Low E-Chem E-Chem E-Chem

Comparing Technologies Accuracy Stability Longevity Det-Tronics NTMOS Sensor Metal Oxide Sensor (MOS) Conventional Electrochemical Accuracy in High Temperatures No Yes Longevity in Extreme Climates Accuracy in Humid Air Accuracy in Dry Air Stable Calibration Over Time

How Does the NTMOS Sensor Work? Target gas reacts with the metal oxide and changes the resistance proportional to the gas concentration. The large sensor surface area absorbs the gas vapor, thus lowering the potential barrier and sensor resistance. Because this resistance change is non-linear and specific to each sensor, it is logarithmically correlated to the gas concentration. Sensor is Incorporated With the Microheater

Nanotechnology MOS = More Surface Area NanoFact Advantages: Increased surface area means a faster response and higher sensitivity — typically T50 is less than 5 seconds Pure material design avoids syndrome of sensor falling asleep NTMOS tolerates extreme temperature and humidity ranges Rugged and long lasting sensor technology Nanotechnology, which deals with devices typically less than 100 nanometers in size, is making a significant contribution to the fields of computer storage, semiconductors, biotechnology, manufacturing and energy. The additional surface area (~10X) is what gives the NTMOS its advantage over original MOS sensor technology.

Ordering the NTMOS

Compatible with FlexVu Display Local Display with Relay, Alarm, and Fault Outputs Combined with isolated 4-20mA 4-20 mA output with HART Nonintrusive Calibration Fully Explosion-Proof Housing Available in 316SS Construction Easy-to-Set Alarm Levels Access to Alarm and Fault History Multiple Conduit Access Points Det-Tronics NTMOS Shown with FlexVu Display

New Toxic Gas Detector Customer Benefits Fast Response (T50 < 5 sec) Means Increased Safety Protection in Extreme Climates with Advanced Sensor Humidity and Temperature Compensation Automatic Calibration with Nonvolatile Memory to Revert to Previous Calibration if Necessary No Undisclosed Failures due to Internal Diagnostics and Automatic Notification Reduced Maintenance Costs with quick set-up and easy device interrogation Det-Tronics NTMOS Shown with FlexVu Display

Our Mission Corporate Headquarters, Minneapolis, MN Det-Tronics, the DET-TRONICS logo, and FlexVu are registered trademarks or trademarks of Detector Electronics Corporation in the United States, other countries or both. Other company, product, or service names may be trademarks or service marks of others.