Why………….? coz Speed thrills but Kills! Why Should Speed Governor / Limiter be Installed.

Slides:



Advertisements
Similar presentations
1. Instrument Clusters Theory Support Automotive – Displays & Accessories 1 of 13 Instrument Clusters Topics covered in this presentation: Analog Instrument.
Advertisements

Setup/Installation/Operation of an Environmental Control Unit (ECU)
HYDRAULICS & PNEUMATICS
Bridgwater College Electronic Ignition - Programme Ignition.
-By Atul Gosavi - Guided by Prof. N.P. Jadhav SEMINAR ON.
ZEEMS II Modular Fuel Systems.
ELECTRONIC FUEL INJECTION. Introduction Strict emission standards require precise fuel delivery Computers used to calculate fuel needs EFI very precise,
Analysis of Spark Ignition Engine Management System
A Familiarization to Speed Governor
HYDRAULIC SYSTEMS and APPLY DEVICES
Chapter 33 Charging System Fundamentals.
NEXT GENERATION ANTILOCK BRAKES VELAMMAL COLLEGE OF
Sensors used in EFI (Electronic Fuel Injection)
Automotive Wave forms.
Sensors and Actuators John Errington MSc. Sensors and Actuators Sensors produce a signal in response to a change in their surroundings e.g. Thermostat.
Starting System Fundamentals
ABS(Antilock braking system)
Electrical Electricity Fuses Relays Solenoids Electrical Testing
ANTI LOCK BRAKING SYSTEM
Abs.
Electro-Pneumatics Module 1
SEMINAR ON “GASOLINE DIRECT INJECTION”
Industrial Machine Control
Motor Vehicle Level 3 Electronics and Electronic Components Resource 1.
Electronic Fuel Injection Vocabulary 1.Injector (solenoid ) 9.)emission standards 2.Stoichiometric14.7 to 1 3.Throttle body of injection 4.Port injection10.)Types.
Propellers The engines are equipped with four bladed, full
Regenerative Braking Systems 27 © 2013 Pearson Higher Education, Inc. Pearson Prentice Hall - Upper Saddle River, NJ Advanced Automotive Electricity.
Directional Control Valve CV691. Present system New Proposed System with CV691 valve Directional Control Valve CV691 with integrated Flow Control Valve.
Charge Controllers Regulating Battery Charging.
9 Electronic Transmission Controls.
ELECTRO – PROPORTIONAL VALVES
Diagnosis and Troubleshooting of Automotive Electrical, Electronic, and Computer Systems, Fifth Edition By James D. Halderman © 2010 Pearson Higher Education,
Automotive Wave forms. Oscilloscope's An oscilloscope can be a priceless price of test equipment used for observation of electrical/electronic wave patterns.
High frequency solenoid valve SX10 Series
Computer Fundamentals 14 © 2013 Pearson Higher Education, Inc. Pearson Prentice Hall - Upper Saddle River, NJ Advanced Automotive Electricity and.
Definition: anti-lock braking system (ABS): is a safety system that allows the wheels on a motor vehicle to continue interacting tractively with the road.
CHAPTER Computer Fundamentals 13 Copyright © 2016 by Pearson Education, Inc. All Rights Reserved Automotive Electrical and Engine Performance, 7e James.
PRESENTATION ON CAMLESS ENGINE
Diesel Engine Management Systems
7/15/2002PP.AFD.09 1 of 43 Yaskawa Electric America Variable Frequency Drives In HVAC Applications.
Diesel Engine Management Systems
Proportional and Servo Valves
Flow Characteristics of Port Fuel Injection System P M V Subbarao Professor Mechanical Engineering Department Matching of Injector with Engine Requirements.
Alphard - Engine Contents Click a Section Tab.
Engine Overall 2UZ-FE Engine
Types of Sensors Used in Multi-Point Fuel Injection System
Diesel Engine Management Systems Steve Baker. Diesel Engine Management Systems Steve Baker.
SEMINAR ON TURBO DIRECT INJECTION ENGINES
Instrument Clusters Topics covered in this presentation:
MULTI POINT FUEL INJECTION
Introduction to Electronic Fuel Systems
Electronic Fuel Injection
Actuators Topics covered in this presentation:
Electronic Fuel Injection
UNIT INJECTOR SYSTEM.
ANTI LOCK BRAKING SYSTEM
Eksempel ABS - Bremser..
Asahi/America Electric Actuators Series 94.
Gasoline electronic Fuel Injection Systems
Subsystems of EFI Chapter 22 Lesson 2.
Figure 18.1 Typical port fuel-injection system, indicating the location of various components. Notice that the fuel pressure regulator is located on.
Diesel Automotive Engines
Electronic Automatic Transmissions
Two Common Types of EFI Chapter 22 Lesson 3.
Asahi/America Electric Actuators Series 94.
Sensors Chapter 17 Lesson 3.
Anti-lock Brake System (ABS)
Actuators Chapter 17 Lesson 5.
Flow Control Valves & Pressure Relief valves
Automotive Technology Principles, Diagnosis, and Service
Presentation transcript:

Why………….? coz Speed thrills but Kills! Why Should Speed Governor / Limiter be Installed

SPEED LIMITATION DEVICE Speed Limitation Device (SLD), commonly known as Vehicle Speed Governor is a micro-controller based electronic unit, which constantly monitors the speed of a vehicle and governs the speed within the set limit. The Unit offers a variety of benefits to the fleet owners, drivers and passengers. The advantages of the Speed Limitation Device include :  Better safety by avoiding over-speeding  Reduced strain on engines, thereby increasing the life of engines  Increased Fuel Economy  Improved Operational Efficiency  Negligible Current Consumption (10 MA in Sleep Mode)  Easy Installation

Speed Limitation Device comprises of Electronic Control Unit : The Electronic Control Unit is the brain of the system that receives the signals from the speed sensor and activates the control module to govern the speed of the vehicle. The Set Speed, Speedometer Ratio and Gearbox rpm are fed into the ECU with the help of a Hand Held Programmer. Speed Sensor : A specially designed two pulse Hall Effect Sensor is used to generate pulses in relation to the speed of the vehicle and transmit the same to the Electronic Control Unit. The sensor is easily mountable on the gear- box without loss or modification to any existing part. The mechanism has been designed to withstand hazardous and dusty, corrosive and grimy environment and ensure efficiency and reliability for a long time.

Solenoid Valve : The solenoid valve is a 2 way valve which controls the flow of fluid through a single passage. It has two ports, an inlet and outlet. A normally closed valve does not pass fuel unless it is energized. There is fail-safe positive valve closing in the event of power disconnection that prevents flooding and overfilling. The long life aluminum casting and waterproof coils insure performance consistency for a long life. Minimum pressure drop and internal design of this valve assures exceptional flow performances.

The Electronic Control Unit is powered from the battery through the Ignition switch. When ignition is turned ON, the ECU is powered. The ECU activates the solenoid valve, which opens allowing the fuel to be injected in to the engine. The electronically controlled, solenoid flow valve regulates fuel and the system offers speed control in all climatic conditions for diesel vehicles. When the vehicle is in motion, the Electronic Control Unit receives frequency signals from the speed sensor mounted on the engine gearbox. At a preset frequency programmed by the computer, the ECU transmits a signal to the fuel flow solenoid valve. The valve closes reducing the fuel supply, which in turn reduces the vehicle speed. The Electronic control unit virtually eliminates all moving parts and there is no throttle delay and the fast reaction time of the solenoid valve makes it one of the most efficient speed limiters. Principle of Operation

Stabilized Speed: Speed shall not vary by more than 4 % of the Stabilized speed (or) 2 Km/hr whichever is higher. The rate of change of speed shall not exceed 0.2 m/sec2 when measured on a period greater than 0.1 seconds. The Speed Limitation Device is designed as per Automotive Industry Standards AIS-018/2001/July 2001 (IS 10250) Tamper Proof Tamper Proofing is achieved by not allowing acceleration beyond the ‘set’ speed in the following conditions: If Power or Signal wires to the ECU are sealed for total security. If ECU Module is bypassed in the event of tampering with a time pulse relay with a set frequency in order to maintain a controlled fuel flow to the solenoid valve. If Speed Sensor is so positioned that it is not easily reachable.

Specifications Sl NoItemSpecificationRemarks 1Rated Voltage12 V24 V DC- 2Rated Electric Current1.0 Amp or Less- 3Operating Temperature-20°C ~ + 80°CWater Proof 4Weight (Net)840 gram / Unit- 5Dimension (package)130x 110x130-

How Does The Limiter Function E C U Solenoid Valve Fuel injection pump Fuel Filte r Diesel Tank sensor Diesel pipe line Electric power Speed signal SCHEMATIC SHOWING PROCESS DIAGRAM FOR SPEED CONTROL

Technical Specifications Electronic Control Unit Operating Voltage:12 V – 32 V DC Operating Temperature:10º C to 55º C ± 2º C Operating Current:150 mA max. Solenoid Valve Operating Voltage:12 V DC Operating Current :500 mA ± 2% Diameter:4 - 7 mm Differential pressure:0 – 2.2 Mpa. Speed Sensor Operating Voltage:10 V – 14 V Operating Frequency:1 Hz to 400 Hz No. of Pulses:2 Pulses / rotation Duty Cycle Signal: 100 % of Total Time Period Output Signal Amplitude: 4 V to 2.7 V

HOVEL’S SPEED LIMITER SYSTEM SYSTEM