Technical presentation SC350

Slides:



Advertisements
Similar presentations
The Basics Equipment Maintenance and Safety
Advertisements

Training Presentation
MANUAL TRANSMISSION ELECTRICAL. OBJECTIVES n Diagnose electrical problems by logic and symptom description. n Perform troubleshooting procedures using.
Club Car IQ Technical Information
Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
Daikin Altherma™ Troubling Shooting
Refrigerators.
Common Faults - Machinery Cover missing or not fitted correctly Action : replace or refit covers Nuts or bolts missing from covers Action : replace Seals.
1 I. Troubleshooting ◆ Troubleshooting of hydraulic machine FailuresReasonsCountermeasures Hydraulic driving motor can ’ t start 1)Fuse burnt 2)Electric.
3” BACKWASH VALVE WITH SUPERSTAR ACTUATOR BASIC SERVICE MANUAL Does not apply to PLC-MP version SUPERSTARS.
Graphic Symbol Location 1. DIN Terminal X52 The machine is powered by electricity using copper cable with 5 wires (3 phase wires + neutral wire +
Presented By. HIGHLY SUGGESTED ITEMS  Condescent Dryer  Chiller  An additional in-line filter  Coalescing Filter  Any and all of these items will.
Troubleshooting Aircraft Charging Systems ( Alternators/Reciprocating Engines) by Herb Spenner.
Section 4: Electric Motors
The DB In-Line Pumpout Unit Easy-to-use control panel with one switch to run the unit. 15 AMP reset fuse. 115 AC External water pump and tank drain have.
Sunday, May 17, 2015 Pressure Booster Service. Sunday, May 17, 2015 Booster Service Basics Control Panel Components Setting a pressure switch Setting.
Sales presentation Welcome to the sales presentation on Nilfisk SC350
California Friendly ® Landscape Training Irrigation System Troubleshooting The Metropolitan Water District of Southern California and the Family of Southern.
Charging System Service
VAT: Volt Ampere Tester
The hand-held unit doesn‘t work properly Fault analysis of MANKAR-CARRY No fluid running out of the atomiser The switch valve is defective The filter is.
CARBURETED FUEL SYSTEM
AccuMax Multi-Point Injection Mechanics
Automotive Batteries.
WELCOME TO THE TECHNICAL presentation OF Sc500
Electrical Electricity Fuses Relays Solenoids Electrical Testing
Technical presentation Nilfisk BR 652/752
Project Goals And Objectives ____________________________________________________ Create a “smart”, customizable, all in one system Little to no learning.
STARTING SYSTEM.
2013 NATEF Task Area A-7 Heating, Ventilation, and A/C A. A/C System Diagnosis & Repair B. Refrigeration System Component D & R C. Heating, Ventilation.
Chapter 9 Cranking Systems.
RT 408 Repairing manual. Chapter one The whole machine problems.
Starter System Service Chapter 33 Page 439. Service Begins with Checking System Check the battery first –Voltage should be 12.6 and while the starter.
CHARGING SYSTEM Major Parts Battery                                               Alternator Regulator.
USA ZAMA BASIC BIS. USA ZAMA What is BIS ?  What does BIS mean? – BIS is an acronym for B alanced I dle S ystem – The BIS system is part of the idle.
MonoDrive & XT Constant Pressure Controller
WELCOME TO THE TECHNICAL presentation OF Sc2000
WELCOME TO THE TECHNICAL PRESENTATION OF SC100 1.
Troubleshooting Small Engine Systems Jason Spurlin 4/10/02 Virginia Tech Edited by the CTAE Resource Network February 2011.
E8 / PPA Solar PV Design Implementation O&M Marshall Islands March 31-April 11, Preventive Maintenance.
I. The whole machine problems. 1. Machine does not work properly Possible causes : 1 ) How to test the voltage: transfer the millimeter to voltage range(20V),
WELCOME TO THE SALES PRESENTATION OF THE NILFISK RIDE-ON SCRUBBER DRYER SC2000 THE AIM OF THE TRAINING IS TO PROVIDE YOU WITH KEY SELLING POINTS SC2000.
Model 12 Intek Horizontal OHV
SAMI MAKERSPACE MAKE: AN ELECTRONICS WORKSHOP. ELECTRICITY BASICS.
Automotive Heating and Air Conditioning, Fifth Edition By Tom Birch © 2010 Pearson Higher Education, Inc. Pearson Prentice Hall - Upper Saddle River, NJ.
WELCOME TO THE TECHNICAL PRESENTATION OF SCRUBTEC R
MCB Connor, Sunny, Kia. What does it do? A circuit breaker is an automatically operated electrical switch designed to protect an electrical circuit from.
 Measurement of difference in potential energy between 2 locations in a circuit.  Also called potential difference  Measured in volts (V)  Drives.
TROUBLESHOOTING ELECTRIC MOTORS
Teknologi Dan Rekayasa
PostBase Automatic Feeder Component Removal Service Training
Starting System Circuit Operation and Testing
34 Chapter Small Engine Performance, Maintenance, and Troubleshooting.
E2 Motors and Motor Starting
AC Repair & Furnace Repair - Tips To Consider
Furnace Cleaning and Some Tips for Repairs
T400 Motor Replacement.
WASHERS.
SB Packing Automatic Downpuller Power Unit
Fuel Supply System Service
MAINTENEANCE AND REPAIR OF STARTING SYSTEMS
Troubleshooting 11/14/2018 Water King Service Seminar.
MINNY 16 TROUBLESHOOTING Doc THE MACHINE DOES NOT START
Domestic Electricity AIM: To understand the use of domestic electricity and safety features such as fuses, circuit breakers and the earth circuit
OBJECTIVES After studying Chapter 24, the reader should be able to: Prepare for ASE Electrical/Electronic Systems (A6) certification test content area.
Delphi Fuel pump. Overshoot protection screw. No load throttle adjust
Changing Oil and an Oil Filter
Presentation transcript:

Technical presentation SC350 Welcome to the technical presentation on NILFISK SC350, The aim of the training is to provide you with technical points of the machine.

Technical specifications VOLTAGE (V) 12 IP PROTECTION CLASS IPX4 INSULATION CLASS III RATED POWER (W) 450 BRUSH MOTOR (W) 240 VACUUM MOTOR POWER (W) 200 AIRFLOW (L/SEC) 17,8 VACUUM (KPA) 6,9 SOUND PRESSURE LEVEL (dB(A)) 64 WATER FLOW (L/M) 0,25 / 0,5 SOLUTION/RECOVERY TANK (L) 11/11 BRUSH PRESSURE (KG) 27 BRUSH SPEED (RPM) 140 BRUSH SIZE (MM) 370

Turnable BRUSH DECK The system works once the machine is lifted due the friction of the rubber pad (D) on the top of the brush allow the deck is pulled by the brush rotation. Disassembly: Remove the screw (C), then remove the hub assembly (D). Remove the 4 screws (E). Remove the gear motor. Remove the 4 screws (A), the flange (B) and disassemble the brush deck. Check the rubber pads (D) for integrity; if necessary replace them.

BRUSH DECK - TROUBLESHOOTING Open circuit The resettable fuse (F1) determines an open in the supply circuit of the brush deck motor. This system allows to prevent the circuits from being damaged under overload conditions. The open in the fuse can be caused by the following: 1. Short circuit in the brush motor wiring harness; fault in the motor. 2. Overvoltage of the gear motor. Brush do not turn Possible causes: 1. The brush motor electromagnetic switch wiring harness is damaged (repair). 2. The brush motor electromagnetic switch (ES1) is damaged (replace). 3. The brush motor fuse (F1) is tripped (reset). 4. The motor is faulty (repair or replace). 5. The wiring harness is damaged (repair). Malfunction of the brush deck mechanical rotation system Possible causes: 1. The rubber pads between deck and brush are worn (replace). 2. The rubber damping joint is worn (replace). 3. The end-of-stroke cable is broken (replace).

BRUSH MOTOR ELECTRICAL INPUT CHECK Lift the machine, Apply an ammeter on the blue power supply cable, Turn on the machine with the main switch, check that the electrical input of the motor is 6-8 Amps at 12V. (without load) If the electrical input is higher: Check if there is dust or dirt (ropes, cables, etc.) on the brush hubs. Disassemble the motor and check the condition of all its components. Replace the motor. NOTE Sealed gearmotor, No carbon brush replacement, No motor available separately, No gearbox available separately

SOLUTION SYSTEM SOLENOID VALVE Solenoid valve (E) has stamped arrow (F) must be tuned in the direction of the solution flow as shown in the figure.

SOLUTION SYSTEM - TROUBLESHOOTING Small amount of solution or no solution to the brush Possible causes: 1. The solution tank valve is clogged/dirty or broken (clean or replace). 2. The solenoid valve (EV) is broken or there is an open in the electrical connection (replace the solenoid valve/repair the electrical connection). 3. There is debris in the solution tank clogging the output hole (clean the tank). 4. There is debris in the solution hoses and/or reducer clogging the flow (clean the hose). The solution reaches the brush also when the machine is off 1. There is dirt or calcium deposit on the solenoid valve gasket (clean). 2. The solenoid valve (EV) is broken (replace).

VACUUM SYSTEM Apply an ammeter on the cable (B), Turn on the machine with the main switch, Check the motor electrical input is 15-18 Amps at 12V.

VACUUM SYSTEM - TROUBLESHOOTING The vacuum system motor does not turn on, Possible causes: 1. The vacuum system motor wiring harness is damaged or disconnected (repair / connect). 2. The fuse (F2) is blown (replace). 3. The vacuum system motor is faulty (check the electrical input). Dirty water vacuuming is insufficient or there is no vacuuming, Possible causes: 1. The vacuum grid with automatic shut-off fl oat is activated because the recovery tank is full (empty the recovery tank). 2. The debris tray is clogged (clean). 3. The vacuum grid with automatic shut-off fl oat is dirty, or the vacuum pre-filter is dirty (clean). 4. The tank cover is not correctly positioned (adjust). 5. The tank cover gasket is not efficient (replace/clean). 6. The vacuum system motor filter is dirty (clean). 7. The squeegee or the vacuum hose is clogged or damaged (clean or repair/replace). 8. The vacuum gaskets are damaged or do not match perfectly (repair or replace). The squeegee leaves lining on the floor or does not collect water, Possible causes: 1. There is debris under the blade (remove). 2. The squeegee blade edges are torn or worn (replace).

Battery & onboard charger Standard on-board charger SPE CBHD2 12V 12A high frequency POWER SUPPLY:100-240 V±10% 50-60 Hz PROTECTION GRADE: IP66 Fully controlled by machine electronics CERTIFICATION: UL RECOGNIZED, PSE MARKED DEFAULT CHARGING CURVES: OPTIMA BATTERIES OPTIMA BATTERY 12V 55 Ah C20 AGM SPIRACEL - BTDCM4.2

Battery & charger curve selection DIPSWITCH CONFIGURATION To change the dipswitch configuration, remove the round black cap located close to the openings on the bottom of the charger using a tool like a screwdriver.

Component Layout

Wiring diagram

END OF PRESENTATION QUESTION & COMMENTS?