Rome, January 17th,2006 Flavio Gatti WHIM and Mission Opportunities TES microcalorimeters in the European context Flavio Gatti University and INFN, Genoa.

Slides:



Advertisements
Similar presentations
Alex C. MUELLER, NuPECC meeting, Athens, March EURONS 1st annual report: Generalities (I) With an EC contribution of 14,056,000 EURONS is.
Advertisements

Space environment and detection : lessons learned from PLANCK/HFI François PAJOT Institut d'Astrophysique Spatiale François PAJOT Institut d'Astrophysique.
Recent progress with TES microcalorimeters and signal multiplexing J. Ullom NIST NASA GSFC SRON J. Beall R. Doriese W. Duncan L. Ferreira G. Hilton R.
Readout ASIC Development VERITAS II Garching, 28 January 2014 Matteo Porro.
X-ray Astronomy Lee Yacobi Selected Topics in Astrophysics July 9.
Astro-E2 and Japanese future space programs for high energy astrophysics Astro-E2 NeXT XEUS Small satellite programs Tadayasu Dotani (ISAS)
Statistical analysis of the X-ray emission properties of type-1 AGN in the XMM-2dF Wide Angle Survey Silvia Mateos Leicester University (UK) Leicester.
ISRSI Meeting, Perugia, January 2005 Integrating Space Radiation Sensing Infrastructures (ISRSI) Review of Old ISRSI Proposal.
CCD-style imaging for the JCMT. SCUBA-2 technology  the ability to construct large format detector arrays  signal readouts that can be multiplexed To.
Detectors for the JWST Near Infrared Spectrograph (NIRSpec) B.J. Rauscher 1, P. Strada 2, M.W. Regan 3, D.F. Figer 3, P. Jakobsen 2, S.H. Moseley 1, T.
X-Ray Spectroscopy. 1 eV 100 eV 10 eV Energy (keV) The need for high resolution X-ray spectroscopy Astrophysical Plasmas: Simulation of the emission from.
Sept. 18, 2008SLUO 2008 Annual Meeting Detector R&D at KIPAC Hiro Tajima Kavli InStitute of Particle Astrophysics and Cosmology.
June X-Ray Spectroscopy with Microcalorimeters1 X-Ray Spectrometry with Microcalorimeters.
Athena – Advanced Telescope for High Energy Astrophysics ATHENA: The Advanced Telescope for High Energy Astrophysics Nicholas E. White, NASA/GSFC On behalf.
Daniele Pergolesi, Institut d’Astrophysique de Paris, Nov 14 th The MARE experiment on direct measurement of neutrino mass Daniele Pergolesi UNIVERSITY.
Cardiff University Astronomy Instrumentation Group IRAM Camera meeting October 13-14, Cardiff University Astronomical Instrumentation Peter Ade.
High-resolution X-ray spectroscopy with microcalorimeters L. Piro Some key scientific drivers: –GRB engine and progenitors: X-ray lines and absorption.
Alex C. Mueller, MANETEURONS PCC-Meeting, Mainz (Germany), April 2006 EURONS 1st annual report: Generalities (I)  With an EC contribution of 14,056,000.
ConX – XEUS meeting Panu Helistö, Mikko Kiviranta Utrecht,
Fast Detectors for Medical and Particle Physics Applications Wilfried Vogel Hamamatsu Photonics France March 8, 2007.
Netherlands Institute for Space Research Development of TES-microcalorimeter arrays and Frequency Domain Multiplexed read-out Henk Hoevers Division Sensor.
Potential Impacts of UV/Optical Photon- Counting DetectorTechnology Developments Christopher Martin California Institute of Technology NRC Technology Roadmap.
Our Mission Visible detectors fully matching the requirements of Adaptive Optics wavefront sensors for 10m class telescopes do not yet exist: current detectors.
1 Workshop on X-ray Mission Architectural Concepts Linthicum, MD December 14-15, 2011 Enabling Technologies for the High-Resolution Imaging Spectrometer.
XEUS cryogenic instrument October 2004 CRYOGENIC SPECTROMETER PROTOTYPE Rationale: Development and demonstration of technical readiness for future.
Opticon Porto 1 High Time Resolution Astrophysics Network Andy Shearer Centre for Astronomy School of Physics, NUI, Galway Ireland.
Scientific objectives for XEUS: Galaxies Groups and Clusters at z~2 Study of the Evolution of clusters in the mass range kT > 2 keV up to z=2. Dynamics,
MANU2: status report Maria Ribeiro Gomes* for the Genoa Group IAP, 14-Nov-05 * pos-doc under TRN HPRN-CT
NUVA Mission NUVA will map and review the instrumental performance of existing and near future capabilities in the UV on a global scale. It will assess.
Large Area Microcalorimeters of the Diffuse X-ray Background Sarah Bank Towson University August 5, 2004.
EURECA  XEUS EURopean-JapanEse micro-Calorimeter Array Piet de Korte.
Fully depleted MAPS: Pegasus and MIMOSA 33 Maciej Kachel, Wojciech Duliński PICSEL group, IPHC Strasbourg 1 For low energy X-ray applications.
Academia Sinica National Taiwan University AMiBA System Performance Kai-yang Lin 1,2 and AMiBA Team 1,2,3 1 Institute of Astronomy and Astrophysics, Academia.
Tobias Haas DESY 8 November 2005 A Pixel Telescope for Detector R&D for an ILC Introduction: EUDET Introduction: EUDET First general ideas (with some interludes)
Instrumental Development in Japan for Future Missions 1.Si strip detectors(GLAST) 2.Supermirror technology 3.New hard-X/  detectors 4.TES calorimeters.
Metallic magnetic calorimeters (MMC) for high resolution x-ray spectroscopy Loredana GASTALDO, Markus LINCK, Sönke SCHÄFER, Hannes ROTZINGER, Andreas BURCK,
JW den Herder 1 18/10/2004 Science case Main science drivers (comsic vision ): Super Novae and the life cycle of matter Study of cluster evolution.
Development of CCDs for the SXI We have developed 2 different types of CCDs for the SXI in parallel.. *Advantage =>They are successfully employed for current.
Observational Astrophysics I
Status of Development of Metallic Magnetic Calorimeters A.Fleischmann, T. Daniyarov H. Rotzinger, M. Linck, C. Enss Kirchhoff-Institut für Physik Universität.
Strasbourg, France, 17 December, 2004, seminairGrzegorz DEPTUCH  MAPS technology decoupled charge sensing and signal transfer (improved radiation.
F. GattiTAUP2007, Sendai, MARE an experiment for the calorimetric search of m  with sub eV sensitivity F.Gatti On the behalf of the Collaboration.
Min Kyu Lee ( 이민규 ) Kyoung Beom Lee ( 이경범 ) Yong-Hamb Kim ( 김용함 ) Low Temperature Detectors 2006 Workshop on the Underground Experiment at Yangyang TEXONO-KIMS.
X-ray emission properties of BLAGN in the XMM-2dF Wide Angle Survey S. Mateos, M.G. Watson, J. A. Tedds and the XMM-Newton Survey Science Centre Department.
Cryogenic Detectors and Test Infrastructure at the University of Leicester G.W. Fraser Space Research Centre, Michael Atiyah Building, Department of Physics.
1 Wojciech Dulinski Pixel 2000, Genova, Italy Pixel Sensors for Single Photon Detection Contents - Idea and basic architecture.
UCSC August 12, 2008 U.S. Upgrade R&D Meeting: Strip Detector  Seiden.
Development of a Segmented Planar Germanium Imaging Detector
XEUS Cryogenic Instrument October 2004 Cryogenic X-ray sensor development in US, Europe and Japan Micro-calorimeters Doped - thermistors Astro-E2.
Metallic Magnetic Calorimeters for High-Resolution X-ray Spectroscopy D. Hengstler, C. Pies, S. Schäfer, S. Kempf, M. Krantz, L. Gamer, J. Geist, A. Pabinger,
Laboratory Astrophysics using an Engineering Model XRS Microcalorimeter Array NASA/GSFCLLNL. F. Scott PorterPeter Beiersdorfer Keith GendreauGreg Brown.
Prospects to Use Silicon Photomultipliers for the Astroparticle Physics Experiments EUSO and MAGIC A. Nepomuk Otte Max-Planck-Institut für Physik München.
DEPARTMENT OF PHYSICS AND ASTRONOMY X-ray Astronomy and Space Instrumentation I3 Meeting, December 2004 Integrating Space Radiation Sensing Infrastructures.
3D-ASICS for X-ray Science
MPI Semiconductor Laboratory, The XEUS Instrument Working Group, PNSensor The X-ray Evolving-Universe Spectroscopy (XEUS) mission is under study by the.
MARE Microcalorimeter Arrays for a Rhenium Experiment A DETECTOR OVERVIEW Andrea Giuliani, University of Insubria, Como, and INFN Milano on behalf of the.
1 MARE Direct determination of neutrino mass with Low Temperature Microcalorimeters Flavio Gatti University and INFN of Genoa CSNII, 29 Sept 2009.
Infinipix DEPFETs (for the ATHENA project) Seeon, May 2014 Alexander Bähr MPE 1 Alexander Bähr Max-Planck-Institute f. extraterrestr. Physics.
Thorsten Lux. Charged particles X-ray (UV) Photons Cathode Anode Amplification Provides: xy position Energy (z position) e- CsI coating 2 Gas (Mixture)
CMB & LSS Virtual Research Community Marcos López-Caniego Enrique Martínez Isabel Campos Jesús Marco Instituto de Física de Cantabria (CSIC-UC) EGI Community.
Yong-Hamb Kim Development of cryogenic CaMoO 4 detector 2nd International Workshop on double beta decay search Oct. 7~ Oct. 8, 2010.
Page Detector and Electronics R&D for picosecond resolution, single photon detection and imaging J.S. MilnesPhotek Ltd T.M. ConneelyUniversity.
UNIVERSITY OF JYVÄSKYLÄ NSC Nanoscience Center Applications of cryogenic detectors in materials research: opportunities for novel instruments Kimmo Kinnunen.
Diagnostics of FRIBs beam transport line
WP microelectronics and interconnections
The XENIA mission Cosmic chemical evolution of baryons
LSST Camera Detector Status
Progress on the development of a low-cost fast-timing microchannel plate photodetector Junqi Xie1, Karen Byrum1, Marcel Demarteau1, Joseph Gregar1, Edward.
Radiation Detection via Transition Edge Sensor (TES)
MARE Microcalorimeter Arrays for a Rhenium Experiment
Presentation transcript:

Rome, January 17th,2006 Flavio Gatti WHIM and Mission Opportunities TES microcalorimeters in the European context Flavio Gatti University and INFN, Genoa

TES  calorimeters context TES  calorimeters context TES (Transition Edge Sensor) is without any doubt the reference technology for very high resolution EDXS (Energy Dispersive X-ray Spectroscopy) TES (Transition Edge Sensor) is without any doubt the reference technology for very high resolution EDXS (Energy Dispersive X-ray Spectroscopy) –TES  calorimeters are presently the LTD (Low Temperature Detectors) with the most outstanding spectral performance (2.3 eV FWHM at 6KeV- NIST 2005, USA) –TES allow a count rate at 10 3 cps and better –Q.E. aproches %, depending on the spectral range NIST, 2005 – single pixel best result

SQUID output

TES  calorimeters context TES  calorimeters context TES technology takes advantage of the widely TES technology takes advantage of the widely –TES are made by using extensively micro-fabrication techniques (surface or bulk micromachining) and planar “all metal” thin film techniques, widely used in MEMS and Microelectronis GFSC – Surf. Micr. SRON

SRON PIXEL

TES  calorimeters context TES  calorimeters context TES allow imaging TES allow imaging –TES  calorimeters can be integrated in a close-packed array with high filling factor for imaging –US (NIST, GSFC-NASA), EU(SRON) have made small arrays from 3x3 to 5x5 –32x32 array with read-out fabricated for the SCUBA-2 exp.

TES  calorimeters context TES  calorimeters context TES read-out is made by SQUID preamplifier TES read-out is made by SQUID preamplifier –SQUID technology is well established but fast Multiplexed read out is a peculiar development needed for these application

TDM FDM

TES  calorimeters context TES  calorimeters context TES micro-calorimeter works below 0.1 K TES micro-calorimeter works below 0.1 K –Development of dedicated of fridge assembly for space application is mandatory –Huge steps forward in the 0.1 K cooling techniques has been made in the last few years: ADR based fridge

The European Context Main question: “is it possible to take in charge the TES detector technology (as a whole) and demonstrate the capability to manage them in order to provide an instrument for a EU X-ray Mission?” Main question: “is it possible to take in charge the TES detector technology (as a whole) and demonstrate the capability to manage them in order to provide an instrument for a EU X-ray Mission?” In EU there is deep expertise in many field of the TES technology, but fractioned in several countries and institution. In EU there is deep expertise in many field of the TES technology, but fractioned in several countries and institution. These activities are mostly under-funded and not coordinated These activities are mostly under-funded and not coordinated Without any doubt excellent results in technological achievements ( i.e. array technology ) and spectral performance, 3 eV FWHM at 6KeV have been made by the SRON group. Without any doubt excellent results in technological achievements ( i.e. array technology ) and spectral performance, 3 eV FWHM at 6KeV have been made by the SRON group.

EURECA consortium An EURopEan MicroCalorimeter Array An EURopEan MicroCalorimeter Array Brings together Europe’s foremost research and technology laboratories working on cryogenic detectors for X-ray instrumentation in a joint effort to develop an Imaging X-ray Microcalorimeter Brings together Europe’s foremost research and technology laboratories working on cryogenic detectors for X-ray instrumentation in a joint effort to develop an Imaging X-ray Microcalorimeter the baseline design already lead to an instrument, currently non-existent in Europe and, which will be fully competitive with similar developments in US and Japan the baseline design already lead to an instrument, currently non-existent in Europe and, which will be fully competitive with similar developments in US and Japan research on detectors and read-out still continues, improved detector designs, detector types, electronics, and read-out concepts are developed. The baseline design of the Imaging X-ray  ex.: tech. break-through in oder to achieve 1 eV research on detectors and read-out still continues, improved detector designs, detector types, electronics, and read-out concepts are developed. The baseline design of the Imaging X-ray  ex.: tech. break-through in oder to achieve 1 eV

The main goal is: The main goal is: –to develop and integrate cryogenic imaging X-ray detectors and read-out electronics in an appropriate cooler by the –Achieve a state-of-the-art performance of a cryogenic microcalorimeter array and its read-out. No such instrument exists within Europe The principal motivation: The principal motivation: –for this activity is that futur X-ray astrophysical mission will most likely employ imaging X-ray microcalorimeters; The missions are either an European effort or will be based on a collaboration between Europe, USA and/or Japan (ESTREMO,DIOS,NEW…). Outside astrophysics: Outside astrophysics: –possible niche-applications may exist in material sciences and fusion plasma diagnostics; non- astrophysical users could be a big community!

The EURECA instruments

EURECA performance guideline for a XEUS-like mission Spatial resolution element - pixel size ≤ 2 arcsec µm Field of view – array size 1 arcmin - 32 × 32 resolution elements Energy range - Detection efficiency 0.1 – 3.0 keV -- > 90% for 1-3 keV FWHM energy resolution keV (goal) Countrate – Effective time constant > 250 c/s/pixel µs Background rejection min. ion. Part. > 95%(TBV) Total countrate c/s (TBV)

EURECA CONSORTIUM Mullard Space Science Laboratory, and X-ray Astronomy Group Univ. Leicester : Cryogenics, Signal analisys Mullard Space Science Laboratory, and X-ray Astronomy Group Univ. Leicester : Cryogenics, Signal analisys VTT, Observatory/University of Helsinki: SQUID readout and FDM VTT, Observatory/University of Helsinki: SQUID readout and FDM Kirchhoff Institut für Physik, Uni. Heidelberg: MMC as future opportunity Kirchhoff Institut für Physik, Uni. Heidelberg: MMC as future opportunity JAXA, Metropolitan Univ, Seiko II: an alternative readout electronics JAXA, Metropolitan Univ, Seiko II: an alternative readout electronics Instituto de Ciencia de Materiales de Barcelona, Instituto de Física de Cantabria, Instituto de Microelectrónica de Madrid, Instituto de Nanotecnología de Aragón, Instituto de Ciencia de Materiales de Aragón: electronic integrated components and films Instituto de Ciencia de Materiales de Barcelona, Instituto de Física de Cantabria, Instituto de Microelectrónica de Madrid, Instituto de Nanotecnología de Aragón, Instituto de Ciencia de Materiales de Aragón: electronic integrated components and films

ITALIAN CONTEXT INAF (Rome), INFN (Genua), Alenia Spazio (Milano) participate to the consortium INAF (Rome), INFN (Genua), Alenia Spazio (Milano) participate to the consortium In the EURECA the Italian Groups are committed to develop and study TES development IrAu (INFN) and Superconducting absorber (INFN), perform test and study on final prototype (INAF), cold FLL-electronics (Alacatel-Alenia Spazio) In the EURECA the Italian Groups are committed to develop and study TES development IrAu (INFN) and Superconducting absorber (INFN), perform test and study on final prototype (INAF), cold FLL-electronics (Alacatel-Alenia Spazio) INFN has a long history (20 years) in LTD (in particular Genoa devoted the last 10 years in TES developments) and Rome INAF group has an outstanding position in spaced base HEA. INFN has a long history (20 years) in LTD (in particular Genoa devoted the last 10 years in TES developments) and Rome INAF group has an outstanding position in spaced base HEA.

The Italian Group The group is collaborating in order to speed up the TES development for a flight instrument. The group is collaborating in order to speed up the TES development for a flight instrument. However a 5.9 eV resolution has been already achieved However a 5.9 eV resolution has been already achieved The Group is working on new detector design aiming to demonstrate the 2-3 eV resolution in a short time. The Group is working on new detector design aiming to demonstrate the 2-3 eV resolution in a short time.