Raul Garcia-Sanchez Research Investigator: Dr. Paul R. Mahaffy Code 699, NASA Goddard Space Flight Center Research Mentor: Dr. Prabhakar Misra Department.

Slides:



Advertisements
Similar presentations
Gas Chromatography.
Advertisements

Introducing AnalyzerPro. Chapter 1: Qualitative Analysis.
Gas Chromatography, GC L.O.:  Explain the term: retention time.  Interpret gas chromatograms in terms of retention times and the approximate proportions.
Improvements in Mass Spectrometry for Life Science Research – Does Agilent Have the Answer? Ashley Sage PhD.
The Proteomics Core at Wayne State University
Mass Spectrometer Autosampler Jake Ahrens Stephen Pearson Kyle Sala Seth Yellin Project Mentor: Professor Jane Hill.
Mass spectrometry in organic chemistry
Gas chromatography–mass spectrometry (GC-MS) is an analytical method that combines the features of gas-liquid chromatographyand mass spectrometry to identify.
Pesticide screening LC-QTOF, Agilent. National Food Institute, Technical University of Denmark Disposition National Food Institute –EURL –NRL –Personale.
Mass Spectrometry Courtesy Purpose of Mass Spectrometry  Produces spectra of masses from the molecules in a sample of material, and.
Lecture 8. GC/MS.
With Supersonic Molecular Beams Maya Kochman and Aviv Amirav
Proposal for a Standard Representation of the Results of GC-MS Analysis: A Module for ArMet Helen Fuell 1, Manfred Beckmann 2, John Draper 2, Oliver Fiehn.
Metabolomics DNA RNA Protein Biochemicals (Metabolites) Genomics – 25,000 Genes Transcriptomics – 100,000 Transcripts Metabolomics – 2,800 Compounds Proteomics.
Smart Templates for Chemical Identification in GCxGC-MS QingPing Tao 1, Stephen E. Reichenbach 2, Mingtian Ni 3, Arvind Visvanathan 2, Michael Kok 2, Luke.
1 Information-Theoretic Mass Spectral Library Search Arvind Visvanathan CSCE 990 Seminar in Multi-Dimensional Chromatography Systems, Informatics, and.
Monitoring the desorption of analytes from nonpolar SPME fibers using high speed gas chromatography Authors: Kimberly Jasch, Tony Borgerding* Department.
1 Welcome! Mass Spectrometry meets Cheminformatics Tobias Kind and Julie Leary UC Davis Course 6: Concepts for GC-MS Class website: CHE Spring 2008.
Application of Comprehensive Two-Dimensional Gas Chromatography - Mass Spectrometry to Forensic Science Investigations Glenn S. Frysinger Richard B.
Instant Notes Analytical Chemistry
FIGURE 5. Plot of peptide charge state ratios. Quality Control Concept Figure 6 shows a concept for the implementation of quality control as system suitability.
My contact details and information about submitting samples for MS
NIST and other spectral databases John C. Huffman IUMSC.
Gas Chromatography And Mass Spectrometry
 ETL: Extract Transformation and Load  Term is used to describe data migration or data conversion process  ETL may be part of the business process repeated.
By, Blessy Babu. What is Gas Chromatography?  Gas spectroscopy is a technique used to separate volatile components in a mixture.  It is particularly.
Where Innovation Is Tradition SYST699 – Spec Innovations Innoslate™ System Engineering Management Software Tool Test & Analysis.
2007 GeneSpring MS GeneSpring for Metabolite BioMarker Analysis using Mass Spectrometry data Agilent Q-TOF VIP Visit Jan 16-17, 2007 Santa Clara, CA Thon.
Organic Mass Spectrometry
Mass spectrometry session. Summary Fiehn (1) Standardization important Reporting important, but has to be feasible Does not matter which MS instrument.
WebVizOr: A Fault Detection Visualization Tool for Web Applications Goal: Illustrate and evaluate the uses of WebVizOr, a new tool to aid web application.
Vienna Atomic Line Database T. A. Ryabchikova Institute of Astronomy RAS.
TPD Workstation Software TPD software for control/ analysis of experiments Multiple temperature steps. Optimised data acquisition.
Laxman Yetukuri T : Modeling of Proteomics Data
SORCE Data Product Use of HDF5 James Johnson and Suraiya Ahmad NASA Goddard Space Flight Center, Code 902 Goddard Earth Sciences Distributed Active Archive.
Polybrominated diphenyl ethers by HRGC/HRMS Coreen Hamilton Brian Fowler Louis Haviland Axys Analytical Services, Ltd.
7000A GC-QQQ Applications Pesticides in Foods (1).
Software Project MassAnalyst Roeland Luitwieler Marnix Kammer April 24, 2006.
AUDIT IN COMPUTERIZED ENVIRONMENT
Implementation of a Relational Database as an Aid to Automatic Target Recognition Christopher C. Frost Computer Science Mentor: Steven Vanstone.
EBI is an Outstation of the European Molecular Biology Laboratory. In silico analysis of accurate proteomics, complemented by selective isolation of peptides.
SELF- AND CO 2 -BROADENED LINE SHAPE PARAMETERS FOR THE 2 AND 3 BANDS OF HDO V. MALATHY DEVI, D. CHRIS BENNER, Department of Physics, College of William.
Metabolomics MS and Data Analysis PCB 5530 Tom Niehaus Fall 2015.
Mars Exploration Rover Machine Using Java Technology Presented by k.Pranusha k.Ishwarya.
Faculty meeting - 13 Dec 2006 The Hubble Legacy Archive Harald Kuntschner & ST-ECF staff 13 December 2006.
THE MYSTERY BEHIND THE DEATH OF A BRIDE By R.S. Verma, R.M. Tripathi and A.K.Dalela Central Forensic Science Laboratory, DFS, MHA, Govt. of India, Sec.36-A,
Aroclor Analysis and the Challenge of Matrix Interference “Using a Holistic approach in the Laboratory to analyze uncommon matrices with Confidence and.
Fatty Acid Recovery and Identification in Mars Analogue Soil Samples Kimberly Lykens Mentor: Michael Tuite Jet Propulsion Laboratory Planetary Chemistry.
INTERNATIONAL DATABASE OF IGNITABLE LIQUIDS User Guide
Evolution GC-MS/MS: Pesticide analysis in canola oil Evolution GC-MS/MS: Pesticide analysis in canola oil Vivian Watts 1, Ingo Christ 1, Mark Misunis 2.
MS Libraries for Forensics: DART-MS and GC-MS
Post translational modification n- acetylation Peptide Mass Fingerprinting (PMF) is an analytical technique for identifying unknown protein. Proteins to.
QUALITATIVE Chemical Analysis
Metabolomics Data Analysis
An integrated GC-MS workflow solution for the determination of (semi)volatiles in drinking water and solid waste according to the U.S. EPA guidelines B.
International Database of Ignitable Liquids
Open source tools for data analysis
Accelerating Research in Life Sciences
LC-MS/MS Identification of Impurities Present in Synthetic Peptide Drugs Dr Anna Meljon*, Dr Alan Thompson, Dr Osama Chahrour, and Dr John Malone Almac.
Accelerating Research in Life Sciences
Accelerating Research in Life Sciences
The use of cyclohexanone as a “derivatizing” reagent for the GC–MS detection of amphetamines and ephedrines in seizures and the urine  B.M. El-Haj, A.M.
Database Systems Unit 16.
Bioinformatics Solutions Inc.
Presentation Title NEMC 2018 Dale Walker, Bruce Quimby Agilent
Best Practices for Identification and Quantitation
Accelerating Research in Life Sciences
Accelerating Research in Life Sciences
Comprehensive, Non-Target Characterization of Environmental Exposome Samples Using GC×GC and High Resolution Time-of-Flight Mass Spectrometry James Carlson,
Presentation transcript:

Raul Garcia-Sanchez Research Investigator: Dr. Paul R. Mahaffy Code 699, NASA Goddard Space Flight Center Research Mentor: Dr. Prabhakar Misra Department of Physics & Astronomy, Howard University

Summary Research Purpose Research Questions Challenges Tools Methodology File Database Contaminants Database Project Timeline Issues

 The primary purpose of the research is to develop an organic contaminants database for the SAM project that supports the Mars Science Laboratory (MSL).  Our work involves the development of an organic contaminants database that will allow us to determine what compounds are found here on Earth and would be inadvertently detected in the Mars soil and gaseous samples as impurities.  In order to develop a comprehensive target database, we utilize the National Institute of Standards & Technology (NIST) Automated Mass Spectral Deconvolution and Identification System (AMDIS) and Ion Fingerprint Deconvolution (IFD) software to analyze the GC/MS data.

 Analyze data from the rover environment using Gas Chromatography Mass Spectroscopy (GC/MS).  Develop an organic contaminants database for the Sample Analysis at Mars utilizing GC/MS analysis tools.  Utilize this database to identify compounds from actual mission samples.

 What organic compounds can be found in the rover structure? Where in the rover can they be found?  How accurately can we determine the compounds from tests to those on the actual rover?  How will identifying these compounds help when the time comes for the actual mission analysis?

 Identifying the correct contaminant from very similar family of compounds. ◦ i.e., Hexamethyl Cyclotrisiloxane vs ◦ Octamethyl Cyclotetrasiloxane  Obtaining the information required to determine the accuracy of our results.  Learning to interpret the spectra efficiently.

 Software ◦ Automated Mass Spectral Deconvolution and Identification System (AMDIS) ◦ National Institute for Standards and Technology (NIST) MS Search ◦ Ion Signature Quantitative Deconvolution (IFD)  Hardware ◦ GC/MS device

 Utilize IFD to identify the TIC peaks, then select the most significant ones.  Run a similarity (based for highest match/rmatch ratio) and an identity search (based on probability) using IFD.  Interpret the results between these searches.  Export the TIC peak spectra to NIST.  Use NIST to identify the spectra and test if it agrees with IFD results.  Insert entry into contaminants spreadsheet.

 AMDIS is a software used to extract clean spectra from complex GC-MS analysis.  It allows you to build your own target compound library.  It is useful when you have noisy Total Ion Current (TIC) spectral files.  It deconvolutes the data, matching the compounds and finds target compounds from the selected library.  It accepts large data files in different formats (.cdf,.ms,.d, etc.)

 When you have the MS for a compound at a certain retention time in the GC, you can run a search command to see if the compound matches an entry in the NIST library.  The NIST library search program returns the compounds that are most likely to be the compound you are searching for.

Compound to identify from the AMDIS Program The possible identity of the compounds sorted by probability. Mass spectra for searched compound and the selected possible compound.

Peak #1 Peak #2 Peak #3 (selected) Highest Peak in selected spectrum Scan Number and Retention time of the spectrum selected. Peak #4 and so on

Hyperlink to the file. Column Information

Unknown compounds have very low probability, do not meet user criteria and have a low match ratio. Link to file database.

 Retrieve and tabulate information regarding the data files and their run parameters, rover location, etc.  Retrieve the temperatures for the data files based on the method used.  Consult with other researchers to ensure that the results returned by our analysis matches with their expectations of what contaminants should be present.  Integrate the new data into the target library and monitor how effective it is in successfully identifying compounds found in the rover’s environment to ensure correct contaminant detection.

 Continue analyzing more test data files as well as real-time data as it becomes available.  Wrap-up the contaminants data base for the Finnigan data.  Develop a program prompt that will ease the retrieval of the file information.  Analyze Coldfinger (CF) data.

 Is the method obtained by Doris Jallice and Dr. John Canham the same? Injection Temperature Entry in File database. Ramp Temp Rate Entry in File database. Final Temperature Entry in File database***.

 Search 1_5nmolstandard.D at RT = ◦ Fluoranthene (C 16 H %, 926/926 Match ◦ Pyrene (C 16 H %, 909/909 Match  Which compound is correct?

 What are acceptable criteria to determine that a TIC peak is significant? GCMS Analysis of Soil Sample, SAM CDR 6-feb-2007, p.46, D. McLennan

 Missing and uncertain information on files. Unable to find information regarding location on rover of materials analyzed. What is the nomenclature for naming samples? Why are all sample types listed as unknown? What format is the archive number and where is the information located?