Novel MS discovery-to-targeted SRM workflows incorporating ROC curve analysis of putative biomarker candidates in bona fide clinical samples Mary F Lopez.

Slides:



Advertisements
Similar presentations
Protein Quantitation II: Multiple Reaction Monitoring
Advertisements

Protein Quantitation II: Multiple Reaction Monitoring
Conclusion The workflow presented provides a strategy to incorporate unbiased glycopeptide identification to generate an initial list of targets for data.
© Copyright 2009 by the American Association for Clinical Chemistry Selected Reaction Monitoring–Mass Spectrometric Immunoassay Responsive to Parathyroid.
* CORRESPONDING AUTHOR Bioanalysis of Exenatide: Intact Versus Signature Peptide Approach to Reach Optimal Sensitivity in Large Molecule Quantification.
TSQ Vantage Multiplexed LC-MS/MS SRM assay for parathyroid hormone (PTH) and variants: Correlation with current clinical immunoassay methods. Bryan Krastins.
Long-Term Biological Variation of Serum Protein Electrophoresis M-Spike, Urine M-Spike, and Monoclonal Serum Free Light Chain Quantification: Implications.
Proteored Multicentric Experiment 8 (PME8) Quantitative Targeted Analysis in Proteomics. An Assesment Study (QTAPAS) ProteoRed WG1-WG2 Meeting Pamplona,
Amino Acid Analyzer Nashwa Othman.
Advantages of a Two-Pass Workflow for Biomarker Discovery in Plasma or Serum Samples for Clinical Research Maryann S Vogelsang 1, Bryan Krastins 1, David.
FIGURE 5. Plot of peptide charge state ratios. Quality Control Concept Figure 6 shows a concept for the implementation of quality control as system suitability.
Improving Throughput for Highly Multiplexed Targeted Quantification Methods Using Novel API-Remote Instrument Control and State-Model Data Acquisition.
Overview Purpose: Accurately estimate peptide retention based on spectrum library data utilizing commonly observed peptides in place of synthetic standards.
Proteomics Informatics Workshop Part III: Protein Quantitation
Fa 05CSE182 CSE182-L9 Mass Spectrometry Quantitation and other applications.
Thoughts on Biomarker Discovery and Validation Karla Ballman, Ph.D. Division of Biostatistics October 29, 2007.
Kyiv, TRAINING WORKSHOP ON PHARMACEUTICAL QUALITY, GOOD MANUFACTURING PRACTICE & BIOEQUIVALENCE Validation of Analytical Methods Used For Bioequivalence.
Isolation of N-linked glycopeptides from plasma Yong Zhou 1, Ruedi Aebersold 2, and Hui Zhang 1,3 * 1 Institute for Systems Biology, Seattle, Washington.
Conclusion  Comprehensive workflow identified approximately 70% more high confident peptide as compare to general search strategy.  The comprehensive.
Tryptic digestion Proteomics Workflow for Gel-based and LC-coupled Mass Spectrometry Protein or peptide pre-fractionation is a prerequisite for the reduction.
Simoa Accelerator Laboratory
Proteomics Informatics – Data Analysis and Visualization (Week 13)
Regular or Decaf? Options for Quantitative Biomarker Discovery Mary F Lopez Director, BRIMS MSACL San Diego, Feb 8, 2011.
Production of polypeptides, Da, and middle-down analysis by LC-MSMS Catherine Fenselau 1, Joseph Cannon 1, Nathan Edwards 2, Karen Lohnes 1,
The following minimum specified ranges should be considered: Drug substance or a finished (drug) product 80 to 120 % of the test concentration Content.
2007 GeneSpring MS GeneSpring for Metabolite BioMarker Analysis using Mass Spectrometry data Agilent Q-TOF VIP Visit Jan 16-17, 2007 Santa Clara, CA Thon.
Serendipity in the Blood: Mass spectrometry in the discovery of clinical biomarkers AFMR Symposium Boston, 4/24/13 Mary F Lopez, Director BRIMS Biomarker.
© 2010 SRI International - Company Confidential and Proprietary Information Quantitative Proteomics: Approaches and Current Capabilities Pathway Tools.
Proteomics and Biomarker Discovery “Research-grade” Targeted Proteomics Assay Development: PRMs for PTM Studies with Skyline or, “How I learned to ditch.
Bringing Metrology to Clinical Proteomic Research David Bunk Chemical Science and Technology Laboratory National Institute of Standards and Technology.
Integrated Targeted Quantitative Method for Insulin and its Therapeutic Analogs Eric Niederkofler 1, Dobrin Nedelkov 1, Urban Kiernan 1, David Phillips.
Outline Selection of candidate proteins for the multiplex analysis of DBS via targeted proteomics The currently employed strategies for the selection.
Additional file 1 1.1Workflow of large-scale proteomic analysis of normal human kidney glomerulus 1.2Detailed procedure of LC-MS/MS analysis Additional.
Chem. 231 – 2/18 Lecture. Announcements Set 2 Homework – Due Wednesday Quiz 2 – Next Monday Set 1 Labs –should be switching instruments today (or after.
Quality Assurance How do you know your results are correct? How confident are you?
A new "Molecular Scanner" design for interfacing gel electrophoresis with MALDI-TOF ThP Stephen J. Hattan; Kenneth C. Parker; Marvin L. Vestal SimulTof.
Evaluation of the Presage™ ST2 ELISA Jun Lu 1, David G. Grenache 1,2 1 ARUP Institute for Clinical and Experimental Pathology, Salt Lake City, UT 2 Department.
June 9th, 2013 Matthew J. Rardin June 9th, 2013 Matthew J. Rardin MS1 and MS2 crosstalk in label free quantitation of mass spectrometry data independent.
Multiple flavors of mass analyzers Single MS (peptide fingerprinting): Identifies m/z of peptide only Peptide id’d by comparison to database, of predicted.
Overview of Mass Spectrometry
Isotope Labeled Internal Standards in Skyline
Salamanca, March 16th 2010 Participants: Laboratori de Proteomica-HUVH Servicio de Proteómica-CNB-CSIC Participants: Laboratori de Proteomica-HUVH Servicio.
 Remember Chemistry panel Quality Control:-  In a medical laboratory, it is a statistical process used to monitor and evaluate the analytical process.
Workflows to set up acquisition methods for scheduled sMRM-HR on the TripleTOF 5600 Start from a data dependent acquisition (DDA) Perform data base search.
What is proteomics? Richard Mbasu and Ben Richards.
The world leader in serving science For Research Use Only. Not for use in diagnostic procedures Quantitative Analysis of 4 Immunosuppressant Drugs in Whole.
DIA Method Design, Data Acquisition, and Assessment
Protein quantitation I: Overview (Week 5). Fractionation Digestion LC-MS Lysis MS Sample i Protein j Peptide k Proteomic Bioinformatics – Quantitation.
Introduction to Liquid Phase Mass Spectrometry
EQUIPMENT and METHOD VALIDATION
Diagnostic clinical chemistry
Raphael Sandaltzopoulos, PhD, MBA Professor at MBG (Molecular Biology) Lab. of Gene Expression, Molecular Diagnosis and Modern Therapeutics,
Target Analyses in Parallel Reaction Monitoring Mode (PRM)
Plasma Free Metanephrines Analysis using LC-MS/MS with Porous Graphitic Carbon Column Xiang He (Kevin) and Marta Kozak Thermo Fisher Scientific.
Table 1. Quality Parameters Being Considered for Evaluation
Multi-Analyte LC-MS/MS Methods – Best Practice.
Jarrett Egertson, Ph.D. MacCoss Lab
Mass Spectrometry Vs. Immunoassay
2 Dimensional Gel Electrophoresis
Pinpointing phosphorylation sites using Selected Reaction Monitoring and Skyline Christina Ludwig group of Ruedi Aebersold, ETH Zürich.
Strategies for Eliminating Interferences in Optical Emission Spectroscopy Best practices to optimize your method and correct for interferences to produce.
Practical clinical chemistry
Using Spotfire for Proteomic Analysis
Bioinformatics Solutions Inc.
Proteomics Informatics David Fenyő
Metabolomics: Preanalytical Variables
ANALYTICAL METHOD VALIDATION
Quality Assessment The goal of laboratory analysis is to provide the accurate, reliable and timeliness result Quality assurance The overall program that.
Quantitative Proteomics II: Targeted Quantitation
Proteomics Informatics David Fenyő
Presentation transcript:

Novel MS discovery-to-targeted SRM workflows incorporating ROC curve analysis of putative biomarker candidates in bona fide clinical samples Mary F Lopez Director, BRIMS Swedish Proteomics Society, Gothenberg, Sweden

Biomarker Discovery-to-Targeted Workflow for Proteomics Fishing for differentially expressed proteins Discovery of putative biomarkers Targeting proteins in known pathways Verification of putative biomarkers

Quantitative Biomarker Discovery using SIEVE and Two-Pass Workflow on Orbitrap Velos

The SIEVE workflow can be described in 3 main steps:

Design and Optimization Robust, commercially available nanoflow LC Commercially available columns Focus on stable spray Focus on high reproducibility of peak intensities, CV<8% Pass 1: Quantification Chromatographic alignment Uncompromised full scan measurements Each sample is measured once – no need for replicates Internal peptide standards (normalization) Triplicate runs of peptide standards every 12 runs (instrument QC) “Top10” data dependent acquisition Stringent Precursor ion selection criteria Pass 2: Identification Targeted fragmentation by Inclusion list Relaxed Precursor ion selection criteria Not all samples measured – subset as determined from SIEVE analysis Internal peptide standards Marker stratification using multi marker and single ROC AUC (SIEVE 1.3) Export to Ingenuity pathway analysis In order to realize the quantitative power of SIEVE, data collection must be very robust methods Inclusion list BRIMS Two-Pass Discovery Workflow using SIEVE and Orbitrap Velos

LC setup for Two-Pass Workflow Thermo Proxeon EasyNanoLC eliminates need for time consuming SPE and sample pump downs. Just acidify, add standards and load digested peptides. Controlled trapping flow rates ensure consistent sample retention and salt removal. Rapid column equilibration allows for enhanced duty cycle. Hydrophobicity differences from trapping column to resolving column allows for effective refocusing. Larger resolving column allows for higher capacity, and rapid application of gradient to the column(flow rates to 1.0uL/min) Waste tubing HV in(from source) 5cm trap column 25cm resolving column From pump/ autosampler To Orbitrap Velos

Data Quality – Spray Stability March 30 April 4 Spray stability is the largest factor in reproducible measurements.

Data Quality – Peak Shape

Data Reproducibility - CV Aligned data

Monitor Lab Environment BRIMS Lab Weather Temperature, Humidity, Power Temperature, Humidity, Power

Method for Assessing Systematic Errors without Sample Technical Replicates Systematic errors are assessed from triplicate acquisition of standard sample. Internal standards are spiked in all samples. Systematic errors are assessed from triplicate acquisition of standard sample. Internal standards are spiked in all samples. Blank Standard s Calibration Top 10 Fragmen ta-tion Sample Full Scan Blank run Standards calibration Column regeneration – top 10 Patient samples – full scan only Pass 1 Acquisition cycle

The Two- Pass workflow increases sensitivity by effectively fractionating samples in silico Typical MS acquisition parameters are not geared for quantification. Data dependent acquisition triggers MS2 based on intensity so most low abundance biomarkers are not identified in complex mixtures with large dynamic range ie blood. Classical “shotgun” approaches focus on physical sample fractionation strategies such as depletion and cation exchange coupled with data dependent acquisition. Physical fractionation such as depletion and cation exchange results in loss of albumin binding proteins and multiple runs for each sample. These approaches are very labor intensive, time consuming and typically do not allow for rigorous quantification and statistical power because fewer samples are analyzed due to time and instrument constraints. The Two-Pass Workflow using Inclusion Lists optimizes parameters for full scan quantification and MS2 triggering separately. This results in: Higher sensitivity and getting deeper into the proteome, ie more ID’s Precise and reproducible quantification Flexibility in creating the inclusion list based upon desired attributes such as differential expression, PTM’s or other parameters. Reducing the number of replicates needed since LC reproducibility and %CV’s are so low (ca 8%) Increases the biological sampling power (can run more samples in a shorter time). Decreases the circular biomarker identification syndrome, ie we identified Albumin AGAIN.

Quantitative Statistics for the Two-Pass Workflow unique peptides Data dependent “Top 10” Inclusion list 1 Inclusion list 2 Inclusion list 3 Data Dependent “Top 10” vs Inclusion list Dataset from a recent collaboration on stroke (discussed in later slides) Ion Score vs Concentration of Spiked Standard Peptide in Plasma

Ongoing collaboration with Dr. MingMing Ning, Mass General Hospital and Harvard University Discovery of Blood Biomarkers in PFO related Acute Stroke Application of Discovery Two-Pass Workflow using SIEVE and Orbitrap Velos

Atrial septum The prevalence of PFOs in the general population is around 25%, but it is doubled in cryptogenic (unknown cause) stroke patients. These patients are often young and “healthy”. If there is a clot traveling into the right side of the heart, it can cross the PFO, enter the left atrium, and travel out of the heart and to the brain causing a stroke. This suggests a causal relationship between PFO and cryptogenic stroke. Supported by NIH/NINDS (Dr Tom Jacobs), MGH Cardio- Neurology Division evaluates patients with PFO related stroke and the therapeutic efficacy of surgical PFO closure and other stroke treatment. Venous blood samples from stroke patients are taken before (upon admission) and at12 month follow up after PFO closure. Biomarkers for PFO-related stroke could be clinically useful. Number of patients Sample typePatient 5PFO pre OPStroke 8Patient matched PFO post OPStroke Collaboration with Dr. M. Ning, Harvard, MGH, on PFO Stroke When the atrial septum does not close properly, it is called a patent foramen ovale or PFO.

SIEVE experiment for the PFO stroke study Sample groups were identified in SIEVE at the beginning of the analysis Number of patients Sample typePatient 5PFO pre OPStroke 8Patient matched PFO post OPStroke

SIEVE data demonstrated high reproducibility and robustness of measurements Reconstructed ion chromatogram of an example frame (not differentially expressed) Whisker plot of expression ratios for all 13 peptides identified for protein gi Gray area represents 90% confidence interval for expected protein ratio 3575 unique peptides and 263 proteins were identified in the study with high confidence 128 were differentially expressed (determined by ratio)

ROC* analysis: How can we quickly rank the potential “usefulness” of putative biomarkers for clinical research? Why? Expression ratio and Pvalue may not necessarily be specific to the pathology. How can we query the data and test the classification power of the target analytes? Create ROC curves by plotting false positives vs true positives while adjusting the criteria threshold. The area under the curve, AUC is a measurement of classification power. Use AUC to select optimal candidates and discard suboptimal candidates. AUC values range from 0.5 to 1.0. An AUC of 1.0 indicates a specificity and sensitivity of 100%. Generate AUC values for individual markers and marker ratios. *Receiver Operating Characteristic (a classification model) Specificity Sensitivity

Top 21 single proteins with highest ROC AUC for PFO Stroke Study * Ratio = PRE OP/POST OP

Biological context? Ingenuity Pathways Analysis (IPA) Top networkLipid Metabolism Top physiological system development and function Neurological Disease Top diseaseHematological system Top Canonical pathways Acute phase signaling Coagulation system Complement system Intrinsic Prothrombin Pathway Extrinsic Prothrombin Pathway The entire PFO stroke dataset was uploaded and analyzed with IPA

Top 2 ROC AUC candidates, selected literature references Clin Chim Acta Apr;402(1-2): Inter-alpha-trypsin inhibitor heavy chain 4 is a novel marker of acute ischemic stroke. Kashyap RSKashyap RS, Nayak AR, Deshpande PS, Kabra D, Purohit HJ, Taori GM, Daginawala HF.Nayak ARDeshpande PSKabra DPurohit HJTaori GMDaginawala HF Biochemistry Research Laboratory, Central India Institute of Medical Sciences, 88/2 Bajaj Nagar Nagpur-10, India. Stroke Jul;38(7): Epub 2007 May 24. Prothrombotic mutations as risk factors for cryptogenic ischemic cerebrovascular events in young subjects with patent foramen ovale. Botto NBotto N, Spadoni I, Giusti S, Ait-Ali L, Sicari R, Andreassi MG.Spadoni IGiusti SAit-Ali LSicari RAndreassi MG CNR Institute of Clinical Physiology, G. Pasquinucci Hospital, Massa, Italy.

Verification and translation of putative biomarkers into targeted assays using SRM and Pinpoint TM Software

Pinpoint software was developed (at BRIMS) to make SRM assays easy, automated and efficient List of Targeted Proteins Discovery data: Protein Discoverer SIEVE Peptide Atlas NIST GPM Recombinant Protein Heavy-Labeled Peptides QC Standards Exhaustive List: - Peptides - Transitions Identify and Verify: - Best Peptides - Best Transitions Refine Transition List Optimize LC Gradient Verify the LC-SRM Assay with Recombinant Digests Analyze Biological Samples Pinpoint Pinpoint Algorithmic prediction

Pinpoint provides assay throughput options… 5-10 peptides peptides peptides peptides Regular multiple SRM Scheduled SRM (tSRM) tSRM + iSRM tSRM + iSRM + Split-n-stitch Automated scoring schemes to help prioritize large analysis into high, medium, low quality bins And more… Single software to help iterative method building to go from protein list to absolute abundance Multi-threaded Extremely easy data and results sharing Customers can give video feedback Video help tutorials to get you started

iSRM – Quantifying and verifying low level biomarkers in biological matrices y3y3 y4y4 y5y5 y6y6 y7y7 y8y8 y9y9 y 10 E L A S G L F P V G F K Primary SRM Transition m/z → NL: 2.48E2 Primary SRM Transition m/z → NL: 1.50E2 Data Dependent SRM Primary and Secondary SRM Transitions NL: 1.12E3

Ongoing collaboration with Dr. MingMing Ning, Mass General Hospital and Harvard University Development of a multiplexed SRM assay for Apolipoproteins: Application Cardiovascular disease and stroke Targeted assay development for high abundance proteins

Ischemic vs hemorrhagic stroke About 80 percent of strokes are ischemic, caused by a blockage of the vessels that supply blood to the brain. More than 400,000 people in the United States every year are affected. About 20 percent of all strokes are hemorrhagic; this type of stroke involves the rupture of a blood vessel in or around the brain. TPA is the only treatment for ischemic stroke. It can only be given within 6 hrs of the event. If TPA is given to a hemorrhagic stroke patient, death can result. An assay that could accurately differentiate ischemic from hemorrhagic stroke quickly would be clinically useful. Diagnosis for acute stroke is currently by: Neurological exam CAT scan MRI Lumbar pucture

Number of patients Blood Collection timesSample type 53Upon admissionIschemic Stroke 26Upon admissionHemorrhagic stroke Development of a multiplexed assay for a panel of apolipoproteins: application to stroke  The relative levels of various apolipoproteins can be important biomarkers for heart disease, stroke, Alzheimer’s, diabetes and metabolic syndrome.  Typically, these proteins are individually measured in blood by immunoassay.  The availability of a multiplexed assay that could simultaneously and quantitatively measure a panel of apolipoproteins would be an extremely useful clinical research tool.  We decided to interrogate clinical samples to see if apolipoproteins could be used to classify different types of strokes. Clinical Samples

Single day development of a multiplexed assay for a panel of apolipoproteins using Pinpoint Import protein sequences and prior LC-MS/MS discovery data library for 10 Apolipoproteins 1 Choose optimal “proteotypic” peptides: ie, Highest intensity and unique. Narrow list down to one peptide per protein 2 3 Choose at least 5 fragment transitions per peptide. This ensures accurate identification of peptides. Create method and run sample triplicates.

ROC analysis of apolipoprotein levels in hemorrhagic vs ischemic stroke patients: Single marker AUC Top AUC for single marker Apo CIII0.80 Apo AI0.76 Apo CII0.70 Apo D Apolipoprotein Panel Apo AI Apo AII Apo AIV Apo B Apo CI Apo CII Apo CIII Apo D Apo E Apo H

ROC analysis of apolipoprotein levels in hemorrhagic vs ischemic stroke patients: Multi marker AUC Top AUC for multi markers Apo CIII and Apo AII0.80 Apo CIII and Apo CI0.87 Apo H and Apo AII0.86 Apo AI and Apo CI Apolipoprotein Panel Apo AI Apo AII Apo AIV Apo B Apo CI Apo CII Apo CIII Apo D Apo E Apo H

Development of an assay for PTH: Collaboration with Intrinsic BioProbes and Mayo Clinic Clinical Chemistry, 2010 Targeted assay development for low abundance proteins Dr. Ravinder Singh Dr. Randall Nelson

The large dynamic range of proteins in blood presents a technical hurdle to the development of SRM assays biomarkers present in low abundance PTH is secreted into the circulatory system to produce healthy concentrations of ca 15 – 65 pg/mL, therefore enrichment is required for mass spec detection PTH range

Intrinsic BioProbes/ThermoFisher PTH assay platform for enrichment of low abundance proteins using MSIA (Mass Spec Immuno Assay) Clinical samples Capture on AB activated tips MSIA TIP Versette (ALH) TSQ Vantage (MS) Affinity Capture Automated Processing Quantitative Analysis  Conventional PTH assays typically rely on two-antibody recognition systems, ie ELISA. Immunoassays cannot accurately differentiate between full length (PTH aa1- 84) and clinically important variants (aa7-84 and others). There is a need for more specific assays that can accurately quantify different clinical variants.

Not all immunocapture/immunoprecipitation methods can deliver the necessary recovery and signal Antibody capture method AnalyteLocation testedLimit of detection (LOD) in matrix pg/mL Analyte MWLOD in matrix pmol/L SISCAPATroponinAddona et al Clin Chem 2009, 55: K50 SISCAPAThyroglobulinHoofnagle et al Clin Chem 2008, 54: K4 96 well ELISA Plate PTHThermo BRIMS unpublished 25010K30 Magnetic beadsPTHThermo BRIMS unpublished 20010K25 MSIA TipPTHLopez et al Clin Chem 2010, 56: K 1

Development of a PTH assay:Top down analysis confirmed that PTH is heterogeneous and variants have clinical relevance Relative Intensity Renal failure samples

We chose 4 tryptic monitoring and 2 variant specific peptides for SRM PTH Variant Map Residue Number N Variant or SRM Fragment [1-84] [7-84] [34-84] [37-84] [38-84] [45-84] [28-84] [48-84] [34-77] [37-77] [38-77] [1-13] [7-13] [14-20] [28-44] [34-44] [73-80] SVSEIQLMHNLGK LMHNLGK HLNSMER LQDVHNFVALGAPLAPR FVALGAPLAPR ADVNVLTK Variant specific

Standard curves for PTH peptide SRM assays demonstrate high precision LQDVHNFVALGAPLAPR SVSEIQLMHNLGK LOD was estimated at ca 8pg/mL and LOQ was calculated to be ca 30 pg/mL. R2 = 0.93 %CV < 10 R2 = 0.98 %CV < 10

Differential expression ratios of PTH peptides in renal failure vs normal Samples, ratios ranged from LQDVHNFVALGAPLAPR (aa28-44)SVSSEIQLMHNLGK (aa1-13)HLNSMER (aa14-20) FVALGAPLAPR (aa34-44) ADVNVLTK (aa73-80) Ratio = 7.6 Ratio = 7.5Ratio = 12.3 Ratio = 9.2Ratio = 4.4

Summary An integrated workflow for quantitative, label-free proteomic analysis facilitates discovery Important components of a discovery platform include powerful instrumentation and software Results from discovery experiments can be translated into targeted assays for biomarker verification

Acknowledgements Mary Lopez- Director David Sarracino- Manager, Biomarker Workflows Bryan Krastins- Biomarker Scientist Amol Prakash- Bioinformatic Scientist Michael Athanas- Software Consultant Taha Rezai Quantitative Proteomics Scientist Jennifer Sutton- Manager, Biomarker Research BRIMS TEAM Thermo Fisher Scott Peterman Amy Zumwalt Andreas Huhmer Bernard Delanghe IBI, ASU Biodesign Institute Randall Nelson Dobrin Nedelkov Paul Oran Chad Borges Mass General Hospital, Harvard U. MingMing Ning Ferdinando S Buonanno Eng H Lo Mayo Clinic Ravinder Singh Dave Barnidge

BACKUP SLIDES

Proxeon Easy-nLC Trap Column 100um x 5 cm PS-DVB 5um(15-20um for dirty samples) particle 300A pore Loading flow rates 5um traps 5uL a min; 15-20uL a min for 15-20um particle traps Resolving column 100um x 25cm C18AQ 200A Buffer A 5% Methanol 0.2% formic acid/water Buffer B 90% acetonitrile 0.2% formic acid water Thermo Nanospray Source Instrument Tuned on angiotensin 1 Lock masses used common polysiloxane and pthalates Two-Pass workflow LC configuration