KASA TECHNOLOGIES LIMITED (Channel Partners of ERICO , USA)

Slides:



Advertisements
Similar presentations
ABOUT US Bondada Engineering Private Limited (BEPL) is formed by a team of qualified professionals with the motto to serve infrastructure sector, providing.
Advertisements

University of Sunderland / MDIS. » Explain the process of internationalization; » Identify reasons for FDI; » Select target markets and sites for exporting.
Striving to exceed customer demands by delivering the best.
Authentic Infotech adding value to business Copyright © 2009 Authentic Infotech Corporate Profile.
Bonding Requirements For Gas Piping Systems Bob Torbin October 2007
INNOVATIVE SOLUTIONS IN SEALING TECHNOLOGY. About FLEET Gaskets Fleet Gaskets India Pvt. Ltd. was established in India in 1999 with a technical know-how.
Earth Ground Resistance The Basics
GROUND We walk on it, play on it, and live on it, but what is it in reality when it comes to communications systems, and how do we obtain a “TRUE” and.
ASHLOK Presents Safe Earthing Electrode (ASEEL)
Telecom Cabling Grounding and bonding.
EE4503 Electrical Systems Design
ASSIGNMENT TEACHER Smt. K.VASUMATHY GROUP MEMBERS:- MANSI DWIVEDI (ET 4 TH SEM) ARTI DWIVEDI (ET 4 TH SEM) DIKSHA CHANDRAKAR (ET 4 TH SEM) MAMTA CHOUDHARY.
Guide to Network Cabling Fundamentals
AC Mitigation Overview
Month Year Working together to achieve your desired outcomes, by delivering service excellence. Building Engineering Solutions for the optimisation of.
Association of Mechanical Engineering and Metalworking Industries of Latvia MASOC Association of Mechanical Engineering and Metalworking Industries.
©2012 Cengage Learning. All Rights Reserved. May not be scanned, copied or duplicated, or posted to a publicly accessible website, in whole or in part.
PRERNA Group Empowering Recruitment Services. Contents Mission & Vision Introduction Services Recruitment Process Technology Portfolio Industry Vertical.
Grounding of Airfield Lighting Joseph Vigilante, PE Penn State/FAA Hershey Conference 2009.
Company Presentation.  Incorporated in the year 2000  Primary focus on Telecom and IT Solutions & Services  Active Player in India & South East Asia.
About Us Premier Talent Search Company Delivering Top end Talent across the Globe Resouring for IT and Management Expertise Resouring for Non-IT and Management.
ASHLOK SAFE EARTHING ELECTRODE LIMITED ----an ISO 9001:2000 certified company & SIGNET COMPONENTS PVT. LIMITED Presents Patented Maintenance Free Earthing.
I n t u i t C o n f i d e n t i a l 1 SMP Service Management Professional Solution Introduction May 2007 Mark Stair President, High 5 Software ,
1 Chemical Rod Features of Chemical Rod Provides Low Impedance Earth Ideal for installations with limited space Product description LYTECH’s Chemical Rod.
AQM for business innovation 1 METEF AQM for business innovation AQM is a large technical services center based in Provaglio d’Iseo – BS offering.
FOOTPRINTS Organisations are continuously looking for Business, Partners, Alliances and Talented People Organisations are continuously looking for Opportunities.
Riyadh Al-Dakheel Group. INTRODUCTION  RDG established in 2000 in the Eastern Province of Saudi Arabia  More than 500 employees are currently working.
PSerc Lightning Protection: A Stroke of Luck? Theory and Application: Customer Side Low Voltage Systems Ward Jewell Wichita State University APPA 2005.
Sanjay Kumar INDIA Renewable Energy Policy Imperatives for Developing Countries.
RPG Vision Going for Growth
OUR PASSION: Earthmoving & Mining Machines Plant Maintenance Fabrication Erection.
The Specialists in ESD Protection EBP Continuous Monitor Vermason.co.uk Made in the United States of America Item Item UK Plug - Euro Plug.
Integrated Grounding, Equipotential Bonding and Lightning Protection in Smart Grids and Smart Buildings – A Multi-Faced Approach Ladies and gentlemen,
Partnership Plus™ Program AFC Distributor Strategy 2004 Return to AFCOnline.com.
Your Trade Connection with India T&A TRADE SOLUTIONS PVT LTD Business with India Starts Here….
Introduction are part of History Started business in 2001 Sourced audio-video consumer electronics. Our mission is to achieve excellence by following.
“WE ARE LOOKING FORWARD TO BEING YOUR PARTNER ”. INTRODUCTION  40HRS. Inc. was founded In the year 2000 in San Jose, California USA.  40HRS Vietnam.
____Real- Deal.in____ Reliable | Efficient | Affordable | Luxurious.
Energy Efficiency in Rotating Equipments Potential and Role of stake holders Pune
____Real-Deal.in____ Reliable | Efficient | Affordable | Luxurious.
“Axis Softech Private Limited is one of the best Travel Portal Development Company based in New Delhi, India. we provide all types of travel software,
V. Sumantran Executive Vice-Chairman Hinduja Automotive Ltd.
Welcome To Biz-Ective 1 We are a team of Professional IT and Sales people who have developed this concept and expanding its services continously.
Electronic Components Distributor. Contact Information PRICE ELECTRONICS, LLC N 138 th Ave Peoria, AZ Ph: Fax:
VM TECHNOLOGIES DESIGN. DEVELOP. DELIVER
DHYEYA BUSINESS SERVICES LLP Strategy Marketing Management Consultancy, IT services and Corporate Training By IIM Alumni Consultants Dhyeya Business Services.
Earthing in an electrical network ensures your safety.
Grounding the Electrical System Reference: AAVIM “Electrical Wiring” Created May 2007.
Committed to connecting the world Overview of ITU-T SG5 Work on Damage protection and safety Guy-Michel KOUAKOU Chairman of Study Group 5 Regional Group.
Proposal and Company Information Document CONTENT About Indagatio Research Our Research Offerings Why Indagatio Research Our Work Process Project Snapshot.
Original Medical (OML) is India’s biggest hospital Medical products exporters and a well-known name in the world of indispensable surgical utensils and.
Address: 16(A)-III, Heavy Industrial Area, Jodhpur (Rajasthan) (India) Website: Website: Phone:
Overview We Take It Further... CORPORATE VISION  “...to make people and businesses realize their true potential by carving out best solutions.”
Radiant Info Solutions Pvt.Ltd.. An ISO 9001:2008 Certified Organisation Company Profile  Radiant was incorporated in the year 2007 with a vision “To.
Axis Softech Private Limited 137, Ground Floor, Sant Nagar, East of Kailash, New Delhi, Delhi Ph. No Mobile No: Website:
Global Earthing Lightning Protection System Market by Manufacturers, Regions, Type and Application, Forecast to 2021 Published: December 2016 Single User.
Rajiv Gandhi Institute of Technology (RGIT)
Arkom Engineering Consultants
Company Profile
Grounding the Electrical System
Axis Softech: Best Travel Portal Development Company
Presentation Protect LTD.
Earthing System Earthing System for : - Electrical Network
Grounding the Electrical System
Sit on the FTTH MENA board and lead the Smart City Advisory group
POWER QUALITY AND MANAGEMENT. TITLE : EARTH GROUND GRID SYSTEM AND POWER GROUND SYSTEM. PREPARED BY : JOBIN ABRAHAM.
CORPORATE PROFILE JUNE 2016
Renovation remodeling house repairing company
Earthing System Earthing System for : - Electrical Network
Contactor A contactor is an electrically controlled switch (relay) used for switching an electrical power circuit. A contactor is typically controlled.
Presentation transcript:

KASA TECHNOLOGIES LIMITED (Channel Partners of ERICO , USA) COMPANY PROFILE

KASA TECHNOLOGIES LIMITED Channel Partners

Facilities Protection Solutions covering: Direct Strike Lightning Protection Transient and Surge Protection Grounding Systems Plus the DESIGN of the installed system

Introduction KASA has been promoted by Mr.K.P.Srivastava, an Engineer by qualification and profession. The Company started its operations offering infrastructure supply & support services for electrical projects and succeeded in obtaining orders from some leading telecom companies. The Company continues evaluating new business avenues with greater scope of growth and services for solutions to the industry.

Company Policy “It will be a continuous endeavor of the company to provide world class state of the art products and services to its valued customers and give them value for money in real time. The management, business partners and the employees of the company will have a un-daunted focus in making this endeavor a reality.”

The Search for Technical Excellence KASA, in its endeavor to achieve technical superiority in their field, became Channel Partners of Erico of USA who are world leaders in state of the art Earthing, Lightning Protection, Grounding solutions and inventors of Exothermic welding called Cad Weld. KASA represents Erico in India as their Channel Partners as well as distributors for their products.

Life time Guarantee We are the only Company which guarantees constant Ohmic value over the entire life cycle (30 to 35 years) of the grounding system installed by us.

Services Evaluation of Earthing and Lightning protection needs. Installation at sites. Consultancy for Earthing and Electrical projects.

We serve Telecom Industry Power/Energy Industry Defence Engineering Industry Petroleum Industry IT Engineering/Architecture/Project consulting

Some of Our Customers Airtel IDEA Cellular Vodafone Aircel Tata Teleservices Ericsson Wipro Siemens Limited HCL DRDO Cabinet Secretariat Reliance Energy (BSES) Reliance energy – Dahanu Power Plant Jay Pee (Hydropower Projects) BEL ThyssenKrupp (Overseas) Jindal

Desirable Grounding System Characteristics Must comply with all local and national codes Low in resistance and impedance Mechanically robust and reliable Resistant to corrosion Life expectancy equal to that of the installation Cost effective A poor grounding system is worse than no grounding system. Keep in mind that codes establish minimum requirements only and are not design guides or installation manuals. Engineers often specify requirements that far exceed the minimum required by code. The grounding system must not only exhibit a low impedance at 60 HZ, but also a low impedance at the high frequencies encountered during lightning and surge events. The grounding components should able to withstand electromagnetic forces as well as resist tampering by the general public. Connectors should not be affected by lawn equipment or people trying to loosen bolted connectors either on purpose or accidentally. Corrosion is the enemy of all grounding components. The selection of materials is critical. Grounding components are located underground, in cement, or behind walls. Inspection of these elements is not easy and there are no warning indications when a conductor has been cut, a connection has loosened, or a ground rod has corroded. Installing products that will never need to be maintained provides the greatest degree of performance and safety. Grounding systems can be installed using products ranging from cheap to exotically expensive. A cost effective system will use the proper product for the application. You would not walk into a substation that had a sign reading “This Substation Is Not Grounded” (hopefully). However, if no such warning exists in the same substation and the connections have increase in resistance or the ground rods corroded, people are at increased risk because they have a false sense of security. Workers in the electrical industry rely on the performance of the grounding system more than the rest of us.

Components of the Grounding System – The “Grounding Chain” Ground Electrode Conductor Grounding Connector Grounding Electrode The Soil Location and Function of Grounding System Components Most ERICO people are familiar with the Grounding Chain. Like a chain, the grounding system is only as strong as its weakest link. Failure of any component renders the entire system ineffective and unable to perform the important functions outlined on the previous slide. They include: Grounding Conductor – typically made from copper, it is available in stranded or solid form and with or without a tin coating. Solid conductor has less surface area than stranded making it better suited for corrosive soils. Stranded conductor is more flexible and easier to work with in larger sizes. Tin plating helps to prevent galvanic corrosion of nearby underground steel. Copperweld or copper coated steel conductor is sometimes used in areas prone to theft. The grounding connector attaches the conductor to the electrode. Brazing, mechanical, and exothermic connections are available. A discussion of the differences between the different types is a separate presentation. The grounding electrode is the “thing” we put in the ground to provide the physical attachment to the earth. Natural electrodes are intrinsic to a facility and include copper water pipe, building steel, and the rebar found in concrete foundations. “Made” electrodes are installed specifically to improve the grounding system performance and include plates, mesh, counterpoise wires, and ground rods. The ground rod is the most commonly installed made electrode and the subject of this presentation. The soil plays a significant role in the final resistance of the grounding system. The conductivity of the soil, measured in ohm-centimeters or ohm-meters (not ohms per centimeter) varies with soil type, moisture content, temperature, and the presence of electrolytes. Soil resistivty is like a golf score, the lower the better. However, the lower the resistivity, the more corrosive the soil tends to be so there is a trade off. The grounding components are located in the harsh underground environment. Most of the time, they will sit there and do nothing. Then, a fault will occur or a lightning strike or surge will require dissipation. At that point, the components will be expected to carry large amounts of current and perform like new.

GROUND RODS (Electrodes) Material Choices

Comparison of life expectancy Material Selection – Earth Rod Comparison of life expectancy Galvanised steel rods are one of the cheapest electrodes available. However, they are not the most cost effective since they have a relatively short service life. Solid copper & stainless steel rods have a long service life. However, they are considerably more expensive than galvanized steel rods. In addition to this, solid copper rods are not suited to deep driving or even driving short lengths into hard ground, without bending. As a compromise, steel cored ground rods, clad in a copper or stainless steel sheath were developed. These ground rods are much less expensive than their solid counterparts. They are capable of being deep driven. However, the sheath of this rod type has been known to slip or tear, particularly the copper version. Once this sheath has been damaged, the integrity of the entire electrode is at risk. 1

GROUND RODS (Electrodes) International standards require a minimum of 0.25 mm copper on a Copperbonded rod ERITECH bonded rod Requirement of BS7430; UL467 Copper specimens buried in 43 soil types for 8-13 yrs Calculated average penetration in 30 years would be 0.17 mm in 41 of the 43 different soils Based on this, 0.25 mm established as minimum Service Life – In Excess Of 30 Years A number of international standards (including BS7430 and UL467) specify a requirement for 0.25 mm (10 mil) minimum thickness of copper deposited over the steel core. This was determined by a series of American tests in which copper specimens were buried in 43 different soils for 8 to 13 years. By measuring weight loss, the average penetration per year was calculated. Using these figures, it was determined that the average penetration in 30 years would be 0.17 mm (6.7 mil) in 41 of the 43 different soils. Based on these tests, 0.25 mm (10 mil) was established as the minimum thickness of copper over the steel. This insures the ground rod will have a life expectancy in most soils of over 30 years. Typical sheathed rod 1

THANK YOU KASA TECHNOLOGIES LIMITED 252B 3rd FLOOR , SANT NAGAR , EAST OF KAILASH , NEW DELHI – 110065. PHONE :- 011 -46516961 / 64. FAX :- 011 – 46516965. EMAIL :- corpoffice@kasatechno.com WEBSITE :- www.kasatechno.com