Pain Stimulator Bryan Eckerle 1, Katharine McFadden 1, Adam Platt 1, Elizabeth Slyziuk 2, Jennifer Wells 1 Advisors: Paul King, Ph.D. 1 and Stephen Bruehl,

Slides:



Advertisements
Similar presentations
VL Connector To introduce the VL wire-to-board and wire-to-wire, crimp style connector series.
Advertisements

LabVIEW 7.1 Tutorial. Measurement Lab. MECH262-MECH261 Imran Haider Malik January 16, 2006.
1 Pain. 2 Types of Pain Acute Pain Acute Pain –Complex combination of sensory, perceptual, & emotional experiences as a result of a noxious stimulus –Mediated.
PNI Connector Purpose: To introduce the PNI wire-to-board and wire-to-wire, crimp style connector from JST. Objectives: Illustrate the intended application.
Data Acquisition Risanuri Hidayat.
Using an FPGA to Control the Protection of National Security and Sailor Lives at Sea Brenda G. Martinez, Undergraduate Student K.L. Butler-Purry, Ph.D.,
Alan Young, Dr. Weidong Zhou and Dr. Hongjun Yang Department of Electrical Engineering, The University of Texas at Arlington, Arlington, Texas Figure.
Introduction to LabVIEW 8.5
Multidisciplinary Engineering Senior Design Project 6508 Controls Lab Interface Improvement Preliminary Design Review 11/11/05 Team Members: Michael Abbott,
Bradley University Department of Electrical and Computer Engineering 2011 Wind Tunnel Control (WEBWIND) By: Adam Green Advisor: Dr. Aleksander Malinowski.
EDGE™ Centering Magnet Device P08028 By: Aaron Burger.
FOLLOWER SENSORS AND ACTUATORS EE 552 INTSTRUCTOR :Dr MOHAN KRISNAN BY MOHAMMED KASHIF IQBAL ANESH BODDAPATTI UNIVERSITY OF DETROIT MERCY.
Characterization of Optical Devices Using Magnitude and Group Delay Measurement Haiqiao Lin, Undergraduate Student Dr. Christi Madsen, Professor Department.
Team Bi-directional -Keith Beland -Christian Brinegar -Justin Marsha.
Multidisciplinary Engineering Senior Design Project 6218 Soft Tissue “Tensile” Tester Preliminary Design Review 2/24/2006 Project Sponsor: Bausch & Lomb.
GE Energy Silicon Wafer Measurement System Team 10 Olin Biddy Scott Johnson Chetwyn Jones Rob McCoy Tim Weber.
Research Methods in MIS
Codey Lozier Christian Thompson Advisor: Dr. Mohammad Saadeh
Productivity Solutions. 2 Healthcare challenges today: profitability Maximizing Profitability –Subjective approximations make it difficult to project.
Autonomous Control of Scalextric Slot Car on User-Defined Track Siddharth Kamath Souma Mondal Dhaval Patel School of Electrical and Computer Engineering.
Automated Feeding Solution for Dog Owners Final Report December 7, 2007 Project Automated Dog Feeder Project Advisor Dr. Hongwei Wu The Canine Hunger Force.
Automated Feeding Solutions for Dog Owners Preliminary Design Review October 19, 2007 Project Automated Dog Feeder Project Advisor Dr. Hongwei Wu The Canine.
ESAT 3640 Therapeutic Modalities
Full Mission Simulation Report New Jersey Space Grant Consortium at Stevens Institute of Technology and Rutgers University Ethan Hayon, Mark Siembab, Mike.
DESIGN OF MODERN INTEGRAGTED LABORATORY-STATION (ILS) FOR ENGINEERING EXPERIMENTAL COURSES M. Kostic, Srinivasa Rao Vaddiraju, Srinivas.
Theoretical Analysis of a Nanosensor based on WO 3 coated Carbon Nanotube for Ultra-high Sensitive Breath Acetone Sensing Ming Xia, Advisor: Prof. Xingguo.
Interfacing Physics Sensors Using National Instruments Educational Laboratory Virtual Instrumentation Suite & LabVIEW by Eric Ethridge Left to right: motion.
Chapter 5 Engineering Tools for Electrical and Computer Engineers.
Accessible Home Vital Signs Monitoring System
LabVIEW Data Acquisition and Analysis Electrocardiogram and Muscle Sympathetic Nervous Activity Jennifer Britton Advisor: Richard Shiavi Biomedical Engineering.
Indigenous software for quantification of autonomic tone Prof. K K Deepak MD, PhD, MNAMS Professor of Physiology All India Institute.
COMPUTER MAIN PARTS By: diego Andrés pulgarin Pérez Teacher: Bertha Inés Ramírez Osorio Cesde 2015.
Blood Pressure Monitor Re-Calibration Lei Qu 1, Ross Hamilton 1,David Lee 1, Haniff Mohd Nor 2 Advisor: Dr. Andre Churchwell 3, Dr. Paul King 1 Acknowledgments.
Educational Laboratory Virtual Instrumentation Suite (ELVIS) May Client: National Instruments Advisors: Dr. Mani Mina, Dr. Diane Rover Group Members:
In-Vivo Device for Measuring and Adjusting Lap-Band Pressure Mark Fritz 1, John Huidekoper 1, Andrew Koivuniemi 1, David Mayhew 1, Chris Schroeder 1 Robert.
CP-154,526, a CRF type-1 receptor antagonist, attenuates the cue-and methamphetamine-induced reinstatement of extinguished methamphetamine- seeking behavior.
Venkateswarlu Gaddam, Gautam Sharma, Neelesh Kumar, Amod Kumar, S.K. Mahna NIT Kurukshetra Central Scientific Instruments Organisation (CSIO) Council for.
Tomotherapy Radiation Treatment for Cancer 3-D Imaging of Target Tissue Helical Delivery Pattern Intensity Modulation Radiotherapy (IMRT) -Multileaf Collimator.
GC/Computer Interfacing Using LabVIEW Courtney Arnott April 22, 2002 CHEM 250.
Introduction to LabVIEW 8.5
Evaluation of Ergonomics of Data Entry System in Neonatal Intensive Care Unit John Fonge 1, Kendra Mills 1, and Brandy Scott 1 Advisor: Dr. William Walsh,
Drop Testing Apparatus Team Members: Deatly Butler Mark Clouse Chris Dux Kris Honas Shaun Scott Drew Stephens Client: Itron, Inc. Brian Priest Technical.
Team: Charlie Haggart, Gabriel J. Martínez-Díaz,
What is Electrical Engineering?
Automated Maze System Development Group 9 Tanvir Haque Sidd Murthy Samar Shah Advisors: Dr. Herbert Y. Meltzer, Psychiatry Dr. Paul King, Biomedical Engineering.
Programmable Biofeedback Chest Exerciser Eileen Bock, Lauren Cassell, Margaret Gipson, Laurie McAlexander Department of Biomedical Engineering, Vanderbilt.
POR:NATALIA RESTREPO BUSTAMANTE. hardware refers to all physical parts of a computer system; its components are: electrical, electronic, electromechanical.
The completed wheel design functions to produce resultant force as a function of voltage. Final Design Redesigned circuit to increase CMRR and amplify.
Pain Stimulator Adam PlattJen Wells Biz SlyziukKalee McFadden Bryan EckerleApril 13, 2004.
Automated Maze System Development Group 9 Tanvir Haque Sidd Murthy Samar Shah Advisors: Dr. Herbert Y. Meltzer, Psychiatry Dr. Paul King, Biomedical Engineering.
Digital Electronics and Computer Interfacing Tim Mewes 5. Computer Interfacing – DAQ cards.
The Use of Virtual Reality for Persons with Balance Disorders Susan L. Whitney, PT, PhD, NCS, ATC University of Pittsburgh Supported by the National Institute.
Probing Pain Perception Client: Christopher Coe, Ph.D. Department of Psychology Advisor: Professor Willis Tompkins Team Members: Stacey Hoebel, Jeff Swift,
.  Attached strain gauges to top and bottom of a new aluminum tab and connected them into a half Wheatstone bridge circuit.  Secured one end of the tab.
PRiME (Physiological Recording in MRI Environment) John Kakareka Signal Processing and Instrumentation Section, Division of Computational Bioscience, Center.
Accessible Home Vital Signs Monitoring System Kristyn Eilertsen Adam Goodale Stephen Kepper Sunil Narayan Stacey Tarver Group 22 BME 272 Advised by Paul.
MEASUREMENTS AND ITS TYPES. Basics of Measurement Theory  Measurement are “ the assignment of numerical to represent (physical properties.)”  Measurement.
ELVIS Educational Laboratory Virtual Instrumentation Suite: Phase II Abstract Problem Statement The goal of this project is to convert the EE 201 labs.
AGROFARM WEATHER MONITOR USING LabVIEW. INTRODUCTION Innovation in agriculture field Implementing instrumentation tech. in agricultural field The quantity.
بسم الله الرحمن الرحيم.
Behavioral and Medical Trends in Sensitivity to the Effects of Caffeine Abstract Caffeine has unquestionably become the world’s most popular psychomotor.
SIGNAL CONDITIONING Signal conditioning is stage of instrumentation system used for modifying the transduced signal into a usable format for the final.
SCADA for Remote Industrial Plant
Data Acquisition Systems
Project Members: M.Premraj ( ) G.Rakesh ( ) J.Rameshwaran ( )
Improving Simulations in the Post Anesthesia Care Unit
Engineering Tools for Electrical and Computer Engineers
Jennifer Britton Biomedical Engineering Vanderbilt University
Pain Stimulator Adam Platt Jen Wells Biz Slyziuk Kalee McFadden
Presentation transcript:

Pain Stimulator Bryan Eckerle 1, Katharine McFadden 1, Adam Platt 1, Elizabeth Slyziuk 2, Jennifer Wells 1 Advisors: Paul King, Ph.D. 1 and Stephen Bruehl, Ph.D. 3 1 Vanderbilt University Department of Biomedical Engineering 2 Vanderbilt University Department of Mechanical Engineering 3 Vanderbilt University Medical Center Department of Anesthesiology Numerical Pain Rating Numerical Pain Rating Numerical Pain Rating Numerical Pain Rating Screening and Questionnaires 5 Min. Resting BP Assessment Assess Baroreceptor Sensitivity (BRS) 15 Min. Seated Rest 5 Min. Seated Rest Insert Cannula Assess Emotions (EAS) Plasma Sample Drug or Placebo Infusion Over 10 Min. 30 Min. Adaptation Assess EAS and Side Effects Plasma Sample Assess BRS: 5 Min. Seated Rest 5 Min. Rest Insert Finger Adjust & Apply Pressure 20 Min. Seated Rest 15s Manual Data Entry & Analysis PROBLEM STATEMENT Dr. Bruehl’s main objective is to understand endogenous pain regulatory mechanisms in humans, with particular interest in the relationship between blood pressure, acute pain sensitivity, and chronic pain. He is currently studying the effects of Yohimbine, a selective α-2 adrenergic receptor antagonist, to understand the role of the adrenergic system in regulation of pain pathways. He is using a device based on the original Forgione-Barber Finger Pressure Stimulator to stimulate C-fibers. The device has a fixed amount of weight attached to a lever with an unknown amount of pressure being applied to the dorsal surface of the second phalanx of the index finger. It is mounted on a table that does not allow for adjustments to accommodate variance in subject height or forearm length. Additionally, the system does not include an electronic output. The administrator asks the subject for a numerical pain rating on a scale from 0 to 100, anchored with “no pain” and “worst pain imaginable,” thus creating a numerical bias. Our objective is to create an adjustable, electronically integrated, and standardized acute pain stimulus to compare responses under placebo and under blockade of various receptors. IMPROVEMENTS ELECTRONIC OUTPUT using LabVIEW 7.1 Automated TimerDigital Data Storage Digital DisplayAbility to Export data for further statistical analysis Graphical OutputAutomated Start of Data Acquisition (contact switch) Audiovisual Cues Adjustability Hand DominanceForearm Length Subject HeightAdjustable Weight Applied directly over Contact Point Pain Reading Linear Potentiometers eliminate numerical bias SYSTEM SCHEMATIC Circuit sensitivity Vs=5V Potentiometer sensitivity = 1500Ω/cm PC Computer LabVIEW 7.1 USB DAQ NI 6009 DEVICE Potentiometer Circuits Contact Switch Circuit IMPROVED EXPERIMENTAL PROCEDURE EXAMPLE OF PREVIOUS DATA Subject Number 008NO GRAPHICAL OUTPUT Reported Pain Level: 30, 50, 65, 90MANUAL DATA ENTRY NECESSARY ADDITIONAL EQUIPMENT National Instruments LabVIEW Version National Instruments USB-6009 Data Acquisition Device Mouser Electronics 60mm Linear 10k Taiwan Alpha Slide Potentiometer RESULTS Time, sec Pain Level PREVIOUS DEVICEIMPROVED DEVICE APPROACHES CONSIDERED Vibration, thermal and electrical stimuli were considered, but ultimately rejected in order to maintain pressure stimulus of C-fibers. A pneumatic pressure device was also considered, but rejected for the stable and reliable lever system already in place. PROJECT DELIVERABLES Modified version of Forgione-Barber Finger Pressure Stimulator Software for data acquisition Vertically adjustable medical table Sliding scales to eliminate number bias Integrated system: device mounted to table, connected to sliding scale and software CONCLUSION Design specifications were met so that the experiment is adjustable for subject variance, automated, and electronically integrated. The study is improved as a result. Screening and Questionnaires 5 Min. Resting BP Assessment Assess Barorecptor Sensitivity (BRS) 15 Min. Seated Rest 5 Min. Seated Rest Insert Cannula Assess Emotions (EAS) Plasma Sample Drug Infusion Over 10 Min. 30 Min. Adaptation Assess EAS and Side Effects Plasma Sample Assess BRS: 5 Min. Seated Rest 5 Min. Rest Insert Finger Adjust & Apply Pressure 20 Min. Seated Rest LabVIEW collects data for 1 minute, data is saved and exported for future statistical analysis EXPERIMENTAL PROCEDURE