M o n t r e a l P r o t o c o l, O E W G - 3 0, G e n e v a, 1 5 - 1 8 J u n e 2 0 1 0 1 XIX/8 Report on HCFC Alternatives for High Ambient Temperature.

Slides:



Advertisements
Similar presentations
UNEP OzonAction Webinar on Challenges for the phase-out of HCFC in the air conditioner sector 17 th October 2012 Sukumar Devotta Member, RTOC and World.
Advertisements

1 HCFC Phase –out in Air Conditioning Sector Background, Challenges and Progress Sidi Menad SI AHMED 17 TH October 2012.
1 Hydrocarbons as Alternatives to HCFC-22 A Cool Solution? UNIDO, Ole Reinholdt Nielsen 10 April 2013.
1 Mobilizing Available Funds To Destroy Ozone Depleting Substances.
Workshop on ODS Bank Management (OEWG-30) Geneva, Switzerland Monday 14 June 2010 Timing, Size and Cost of ODS Bank Management Opportunities Paul Ashford.
HFCs: A Critical Link in Protecting Climate and the Ozone Layer Alternatives to high-GWP HFCs UNEP side-event, Montreal Protocol MoP-23, 21 November 2011.
Report of the TEAP XXI/9 Task Force
T E A P a n d T O C s - A s s e s s m e n t , M O P - 20, D o h a 1 The TEAP and TOC 2010 Assessment Reports Timelines and issues that will be dealt.
T E A P a t M o n t r e a l P r o t o c o l M O P - 2 0, N o v , D o h a 1 TEAP Update Presentation for MOP-20.
0 - 0.
Valorisation of Low-Grade Waste Heat
ACTIVE LEARNING PROCESS
INDO-US WORKSHOP ON HYDROFLUOROCARBONS (HFCs)
REFRIGERATION SYSTEMS
Air Conditioning EPA Type III.
Chapter 9 REFRIGERATION AND LIQUEFACTION
REFRIGERATION, HEAT PUMP CYCLES
Updates on alternative technologies and international developments in the Refrigeration and Air Conditioning Sectors.
Refrigeration Cycles CHAPTER 11: PTT 201/4 THERMODYNAMICS
Seite 1 GTZ PROKLIMA INTERNATIONAL PROKLIMA The potential for hydrocarbon refrigerants as HCFC-22 replacement in air conditioning Atmosphere.
REFRIGERATION.
Market Presence Grows with Environmental Concerns.
Andrea Mariottini Riello Gas Boilers Division
What is. SummitPlus + is a high performance replacement for R-22 refrigerant in R-22 AC systems.
The Challenge: Moving Away From HCFC Refrigerants.
A/C Final Project: Design Builder
Air Conditioners.
Addition 1’s to 20.
ENERGY SURVEYING Please Click through this presentation.
Energy Saving in Hospitals: Hong Kong Initiatives
10 CHAPTER Refrigeration Cycles.
POLICY ON HFC IN SEYCHELLES Presented by Inese Chang-Waye National Ozone Coordinator.
1 Report on Decision XXIII/11 Use of ODSs on ships.
Technical Seminar on Refrigeration & Air Conditioning
Moisture to water converter. Out Line : Abstract Introduction Heat Pump Heat Pump Components Conclusion.
Michael Galka and Dr. Paul Blowers The University of Arizona
Session I Challenges and opportunities in addressing high-GWP HFCs in the refrigeration sector.
New Refrigerants Question Time Introductory Comments Ray Gluckman Director, Climate Change SKM Enviros April 26 th 2012, RAC, London.
Current and Future HFC Demand
REFRIGERATION & AIR CONDITIONING DIVISION Hydrocarbons for Domestic Appliances Dr.-Ing. Jürgen Süss VP R&D Brussels, October 2009.
UNEP Workshop on HFCs management.
Overall issues for adequate design for high-ambient temperature operation by: Samir Hamed Petra Engineering Ind. Co. Rtoc member.
Technical consideration of feasibility of low GWP alternatives: performance, cost, et.al. Kazuhiro Sato Mitsubishi Heavy Industries, Ltd. On behalf of.
1 Current and Future HFC Demand by Sectors Bella Maranion TEAP co-chair OEWG-35, Bangkok, 22 April 2015.
H F C M a n a g e m e n t W o r k s h o p, J u l y , P a r i sRoberto Peixoto - IMT Roberto A. Peixoto Maua Institute of Technology - IMT.
Summary of the rapporteurs Key conclusions of the Workshop on HFC Management: Technical issues K. Shepardson / S. Sicars OEWG Bangkok 22 April 2015.
Low-GWP options for cascade systems for medium-sized and larger commercial refrigeration equipment Workshop on HFC management Bangkok 20 th April 2015.
UNEP Ozone Secretariat Workshop on HFC management: technical issues Overview of HFC Market Sectors Presentation by Lambert Kuijpers, Ray Gluckman and Sukumar.
Refrigeration Cycles Chapter 11: ERT 206/4 THERMODYNAMICS
REFRIGERATION, COMPRESSED AIR SYSTEMS & EFFICIENT USE OF ENERGY
Dr Daniel Colbourne 36th Meeting of the Open-ended Working Group of the Parties to the Montreal Protocol – Side Event UNEP.
36th OEWG UNEP SIDE EVENT 22 J u l y , P a r i sRoberto Peixoto - IMT Roberto A. Peixoto Maua Institute of Technology – IMT Brazil Disclaimer: The.
Availability of Low-GWP Alternatives Options for Near Term & Longer Term Transitions OZONACTION NETWORK FOR LATIN AMERICA AND THE CARIBBEAN OCTOBER 6-8.
INDUSTRY PROGRESS AND NEEDS FOR REPLACING HIGH GWP HFC S Montreal Protocol HFC Management Workshop Paris July 11, 2014.
Challenges Faced by Companies in Article 5 Parties in Converting to Low-GWP options R K Mehta RAMA – INDIA 20 th & 21st April 2015 Bangkok.
M o n t r e a l P r o t o c o l M O P - 2 6, N o v e m b e r , P a r i s 1 TEAP XXV/8 Task Force Report SUPPLEMENT to the Assessment of.
Basic Refrigeration. Star Refrigeration Wednesday 12 September 2007.
Update on HPMP preparation Art. 5 and CEIT ECA Network meeting - May 18-22, 2009 Yerevan, Armenia.
REFRIGERATION Refrigeration is a process in which work is done to move heat from one location to another. Uses of Refrigeration :  Industrial uses 
Refrigeration and Heat Pump Systems
HVAC EQUIPMENT: COOLING SOURCES (see Chapter 16)
Commercial Refrigeration Trends and challenges for RECS
THIRD ANNUAL CO3OL WORKSHOP
Hydrocarbon Refrigerants
TEAP XXV/8 Task Force Report
Presentation by Ray Gluckman July 9th 2018, Vienna
Radhey S. Agarwal Member, OORG
ODS AND ALTERNATIVES IN RAC SECTOR
CHALLENGES IN MEETING 2020 HCFC PHASE OUT TARGETS
Presentation transcript:

M o n t r e a l P r o t o c o l, O E W G - 3 0, G e n e v a, J u n e XIX/8 Report on HCFC Alternatives for High Ambient Temperature Regions Lambert Kuijpers Roberto Peixoto TEAP, co-chairs UNEP Refrigeration TOC

M o n t r e a l P r o t o c o l, O E W G - 3 0, G e n e v a, J u n e Decision XIX/8 At MOP-19 in Montreal, Decision XIX/8 was taken related to HCFC alternatives and specific climatic conditions: To request the TEAP to conduct a scoping study addressing the prospects for the promotion and acceptance of alternatives to HCFCs in the refrigeration and air conditioning sectors in Article 5 Parties, with specific reference to specific climatic conditions and unique operating conditions, such as those in mines that are not open pit mines, in some Article 5 Parties; To request the TEAP to provide a summary of the outcome of the study referred to in the preceding paragraph in its 2008 progress report with a view to identifying areas requiring more detailed study of the alternatives available and their applicability

M o n t r e a l P r o t o c o l, O E W G - 3 0, G e n e v a, J u n e Status 2010 Decision XIX/8 asks for guidance on the replacements for HCFC-22, which is a commonly used refrigerant under hot ambient conditions An RTOC sub-committee was assembled Delay in 2008 was due to problems in gathering accurate commercial product data from different countries Delay in 2009 was due to logistics, including difficulties in organising visits to South African mines Final report review at TEAP meeting 2010

M o n t r e a l P r o t o c o l, O E W G - 3 0, G e n e v a, J u n e High Temperatures in Many Places

M o n t r e a l P r o t o c o l, O E W G - 3 0, G e n e v a, J u n e A wide variety of candidate refrigerants (HFC, HFC based blends, HCs) can replace HCFC-22 in very hot climates Refrigerant selection pays attention to: Global Warming Potential, Cooling capacity at elevated ambient temperatures, Energy consumption, energy efficiency and related impacts on electricity supplies, availability of the refrigerant alternatives and suitable equipment. Refrigerants for High Ambient Temperature Air Conditioning

M o n t r e a l P r o t o c o l, O E W G - 3 0, G e n e v a, J u n e R-410A & R-407C Have Inferior Technical Performance to R-22 in AC In AC, the primary global replacement, especially for the dominant air-cooled designs, is R-410A One component of this blend, HFC-125, has a comparatively low critical point temperature (66 o C), resulting in a rapidly declining capacity and efficiency as condensing temperatures approach the critical temperature of the blend The same effect occurs with the blend R-407C

M o n t r e a l P r o t o c o l, O E W G - 3 0, G e n e v a, J u n e Elaborated Analyses For AC, condensing temperatures have been varied between 35 and 65 C 65 C condensation may occur at ambient temperatures in the range of C, if no precautions in design taken Even if 65 C condensing temperature would lead to substantial efficiency and capacity decreases, note that this temperature will only occur during part of a season, leading to much lower impact on annual performance Additional system design features (such as night operation combined with cold storage) have positive effects

M o n t r e a l P r o t o c o l, O E W G - 3 0, G e n e v a, J u n e Refrigerant Efficiencies at Various Condensing Temperatures 8

M o n t r e a l P r o t o c o l, O E W G - 3 0, G e n e v a, J u n e Application engineers will need to oversize equipment to compensate for the reduced capacity at the design ambient temperature In most cases R-410A or R-407C will need to be sized 5-10% larger than HCFC-22 equipment to compensate for the lower capacity at ambient temperatures up to 50 C The increased capital cost of oversizing the equipment will be about 3% for a 10% increase in capacity 9 Refrigerants for High Ambient Temperature Air Conditioning

M o n t r e a l P r o t o c o l, O E W G - 3 0, G e n e v a, J u n e The natural refrigerant HC_290 can replace HCFC-22 in low charge applications (small window and portable room air conditioners). When replacing HCFC-22 with HC-290 one needs to consider appropriate design changes to minimise the refrigerant charge of HC-290 to comply with the applicable codes and standards on refrigerant charges and flammability 10 Refrigerants for High Ambient Temperature Air Conditioning

M o n t r e a l P r o t o c o l, O E W G - 3 0, G e n e v a, J u n e HFC-32 and HFC-32 in blends are candidates for the longer-term replacement of R-410A The refrigerant HFC-32 is very moderately flammable HFC-32 has a GWP approximately one third of the GWP of R-410A and exhibits much better high ambient performance than R-410A Design changes required to convert from R-410A to HFC-32 are minor 11 Emerging Refrigerants for High Ambient Temperature Air Conditioning

M o n t r e a l P r o t o c o l, O E W G - 3 0, G e n e v a, J u n e Refrigerants for High Ambient Temperature Refrigeration The primary global replacement for commercial refrigeration is R-404A. The two components of this blend are HFC-125 and HFC-143a, both having relatively low critical temperatures causing a rapidly declining capacity and efficiency as condensing temperatures approach the critical temperature of the blend The study examines the suitability of R-404A, HCs, CO2 and ammonia as candidate HCFC-22 alternatives for very hot climates

M o n t r e a l P r o t o c o l, O E W G - 3 0, G e n e v a, J u n e For stand alone equipment, in high ambient temperature conditions, one high-GWP refrigerant (HFC-134a) and three low-GWP refrigerants (HC-600a, HC-290 and possibly HFC-1234yf) can be used with the current refrigeration technologies For centralized systems, low-GWP toxic and flammable refrigerants can be used in indirect systems conditions because there is no significant variation of the evaporation temperature 13 Refrigerants for High Ambient Temperature Refrigeration

M o n t r e a l P r o t o c o l, O E W G - 3 0, G e n e v a, J u n e HFC blends with high GWP, such as R-404A or even R-422D or R-427A can be used, but for those two blends the refrigerating capacity could be lower by about 5% and the efficiency could also be lower by 5-10% HCs, such as HC-290 and HC-1270, can be used at high ambient temperature since they exhibit relatively low discharge temperatures compared to HCFC-22. However, refrigerant quantities have to be limited for safety reasons 14 Refrigerants for High Ambient Temperature Refrigeration

M o n t r e a l P r o t o c o l, O E W G - 3 0, G e n e v a, J u n e The new low-GWP short-lived HFC-1234yf as well as new low-GWP blends can be expected to be commercialised during the next three years These new low-GWP refrigerants might also be used in indirect systems or cascading systems with CO 2 either as a refrigerant (in the low stage) or as a heat transfer fluid 15 Refrigerants for High Ambient Temperature Refrigeration

M o n t r e a l P r o t o c o l, O E W G - 3 0, G e n e v a, J u n e Refrigerants for Deep Mines The technology for deep mines is rather different than for high-ambient temperature operation The ambient heat rejection (refrigerant condensing) temperatures generally are less extreme in mines In addition, with low humidity, heat rejection typically employs water cooling towers rather than air-cooled condensers (i.e., the governing performance parameter is the wet-bulb rather than the dry-bulb temperature) 16

M o n t r e a l P r o t o c o l, O E W G - 3 0, G e n e v a, J u n e Refrigerants for Deep Mines A study tour of deep mines was made to South Africa in the second part of 2009 During the tour, leading mining companies, the engineering firms supporting them, researchers, and government contacts were consulted to verify the problems and confirm the solutions 17

M o n t r e a l P r o t o c o l, O E W G - 3 0, G e n e v a, J u n e Most newer mine chillers in the last decade have used HFC-134a, or ammonia (R-717) However, some older and some small mines use HCFC-22 Some newer installations use HCFC-123 to attain high efficiencies Some recent systems use water (R-718) as a refrigerant in a vacuum, with a vapour-compression flash cycle to produce ice slurries directly Some proposed systems would use air (R-729) in air- standard reverse Brayton cycles Refrigerants for Deep Mines

M o n t r e a l P r o t o c o l, O E W G - 3 0, G e n e v a, J u n e Summary for both AC & Refrigeration Some HFC blends that are alternatives for HCFC-22 have a low critical point temperature (66 o C), resulting in a rapidly declining capacity and efficiency as condensing temperatures approach the blend critical temperature

M o n t r e a l P r o t o c o l, O E W G - 3 0, G e n e v a, J u n e Summary (AC) In most cases equipment using R-410A or R-407C will only need to be sized 5-10% larger than HCFC-22 equipment to compensate for the lower capacity at ambient temperatures up to 50 C As a HCFC-22 alternative, HC-290 is suitable in low charge applications (<250 g) with appropriate design changes to comply with all applicable codes/standards HFC-32 is a candidate for the (longer-term) replacement of R-410A

M o n t r e a l P r o t o c o l, O E W G - 3 0, G e n e v a, J u n e Summary (Refrigeration) The use of indirect systems is possible at high ambient temperature conditions R-404A, or even R-422D or R-427A can be used, but the refrigerating capacity and the efficiency would decrease by about 5% and 5-10% HCs such as HC-290 and HC-1270 can be used in hot climates; they exhibit relatively low discharge temperatures compared to HCFC-22 The new low-GWP short-lived HFC-1234yf and new low- GWP blends can be expected during the next three years; they may also be used in indirect systems

M o n t r e a l P r o t o c o l, O E W G - 3 0, G e n e v a, J u n e Summary (Deep Mines) The ambient heat rejection (refrigerant condensing) temperatures generally are less extreme in mines. In addition, heat rejection typically employs water cooling towers rather than air-cooled condensers Most mine chillers in the last decade have used HFC- 134a, or ammonia (R-717) HCFC-22 old chillers can be mostly replaced by HFC-134a and ammonia chillers