T HE S OUNDS OF L IFE C ENTER AT U MASS M EMORIAL Current Technique in the Audiologic Evaluation of Infants Todd B. Sauter, M.A., CCC-A Director of Audiology-

Slides:



Advertisements
Similar presentations
Characteristics of Congenital Hearing Loss Barbara S. Herrmann, Ph.D. CCC-A Audiology Department Massachusetts Eye and Ear Infirmary Harvard Medical School.
Advertisements

Antonia Brancia Maxon, Ph.D. Texas ENT Specialists, P.A.
Diagnostic Pediatric Audiology from Birth to Intervention
AUDITORY BRAINSTEM RESPONSE (ABR) DR.S.H.HASHEMI 1.
IAPA Summer School 2008 Neonatal Hearing Screening and Auditory Neuropathy Berlin, Germany April 10th and 11th UPDATING THE ELECTROPHYSIOLOGY IN NEONATAL.
Limitation of Click-Evoked ABR: Lack of Frequency-Specificity
Program.
AUDIOGRAM AND IMMITTANCE TUTORIAL
Pre-operative evaluation and post-operative rehabilitation for paediatric cochlear implantation Han Demin, M.D., Ph.D. Beijing Institute of Otolaryngology.
M.Sc. in Medical Engineering
TOPIC 5 NONBEHAVIORAL ASSESSMENT MEASURES IMMITANCE AUDIOMETRY.
Measurement of Hearing and Audiogram Interpretation
ASHA 1997 HEARING SCREENING GUIDELINES ASHA Guidelines for Hearing Screening - Children 1997.
Early Childhood Hearing Screening in Colorado. Screening Mandates Newborn Grades K, 1,2,3,5,7,9 Child Find BUT A GAP STILL EXISTS!
Hear and now: Chinese Health in NZ
Provider 10 minute Refresher Course June Special Instructions ●Be sure to put on Slide Show view ●Use your mouse to select your answers ●Click anywhere.
Physiologic Measures Physiologic Tests in Audiology Otoacoustic Emissions Evoked Potentials Immittance Measures.
Continuity Clinic Tympanometry. Continuity Clinic Objectives Identify the uses and limitations of tympanometry and SGAR in the diagnosis of otitis media.
Measuring the brain’s response to temporally modulated sound stimuli Chloe Rose Institute of Digital Healthcare, WMG, University of Warwick, INTRODUCTION.
Understanding and Interpreting Acoustic Reflexes
SPED 537 ECSE Methods Multiple Disabilities Ch 6 & 7 Deborah Chen, Ph.D. California State University, Northridge April
1 Special Testing. 2 Site of Lesion Cochlear—sensory Nerve—neural (retrocochlear) Reliability vs. validity.
Audiological Evaluation A to Z
Audiological Evaluation
Otoacoustic Emissions Low-level sounds produced by the cochlea and recordable in the external ear canal. Spontaneous Click-evoked Distortion Product Stimulus.
Cochlear Implants American Sign Language Children & Cochlear Implants Psychological Evaluation of Implant Candidates James H. Johnson, Ph.D., ABPP Department.
Instrumentation 2/22/00. Magnetic Resonance Imaging Magnetic field through tissue Pass radio waves through tissue –Protons absorb some energy & change.
Test of Hearing And Pure tone Audiometry
Bastaninejad, Shahin, MD, ORL-HNS
Clinical Applications
The Ear.
CSD 2230 HUMAN COMMUNICATION DISORDERS Topic 5 Hearing Disorders and Hearing Loss Assessment.
Reading an Audiogram. Air vs. Bone Conduction A/C  Via TDH-50P headphones Placed on Pinna  Checks the validity of entire ear system  Tests that ipsilateral.
Test of Hearing And Pure-tone Audiometry
Pure Tone Audiometry most commonly used test for evaluating auditory sensitivity delivered primarily through air conduction and bone conduction displayed.
THE BIONIC EAR BME 181 SEMINAR Mihir Subash. WHAT IS THE BIONIC EAR?  A Bionic Ear, which is known as a cochlear implant, is an artificial hearing device,
Need for cortical evoked potentials Assessment and determination of amplification benefit in actual hearing aid users is an issue that continues to be.
Acoustic Immittance Otoacoustic Emissions Auditory Evoked Potentials Objective Tests.
Auditory Brainstem Response
Otoacoustic Emissions Low-level sounds produced by the cochlea and recordable in the external ear canal. Spontaneous Click-evoked Distortion Product Stimulus.
Introduction to Cortical Auditory Evoked Potentials (CAEP)
Hosted by Mrs. Manning AudiologyHEARING LOSS AUDIO- GRAMS SOUND
Otoacoustic Emission Test. What are otoacoustic emissions? These are low intensity sounds produced by the cochlea as the outer hair cells expand and contract.
AEPs Ahmed Khater, MD, PhD Ass. Prof. of audio-vestibular medicine
Otoacoustic Emissions Objective tests of Hearing.
AUDIOLOGY IN ORL DR. BANDAR MOHAMMED AL- QAHTANI, M.D KSMC.
INTRODUCTION TO TYMPANOMETRY
Hearing Loss Basic Audiology Information By El Eshun.
Otoacoustic Emissions
52 The Sense of Hearing Dr. A.R. Jamshidi Fard 2011.
Screening Tests for DISORDERS!!! Or Crusading the Clinic.
Objective Tests of the Auditory System SPA 4302 Summer A, 2004.
Introduction to Audiology How to Read an Audiogram Degrees of Hearing Loss Types, Causes and Prevalence of Hearing Loss Types of Tests.
TOPIC 3 OVERVIEW OF HEARING ASSESSMENT. Hearing Evaluation “The main purpose of the hearing evaluation is to define the nature and extent of the hearing.
Introduction to Audiology Ed Brown Consultant Clinical Scientist (Audiology) South of Tyne NHSP Local Director Royal Hospital Sunderland SR4 7TP
Newborn Hearing Screening. R EPUBLIC A CT N O AN ACT ESTABLISHING A UNIVERSAL NEWBORN HEARING SCREENING PROGRAM FOR THE PREVENTION, EARLY DIAGNOSIS.
HEARING- 3. LEARNING OBJECTIVES LEARNING OBJECTIVES Discuss the principles used in performing tests of hearing Discuss the principles used in performing.
HEARING Module 20. Hearing – sound waves  Audition – the sense or act of hearing  Frequency – the number of complete wavelengths that pass a point in.
Acoustic Immitance (Impedance and Admittance)
Diagnostic and Rehabilitative Audiology Danielle Rose, Au.D. Clinical Audiologist Vanderbilt Bill Wilkerson Center.
Auditory Evoked Potential (AEP)Testing
Interpretation Normal acoustic reflex threshold
Computer Architecture and Networks Lab. 컴퓨터 구조 및 네트워크 연구실 Auditory Brainstem Response : Differential Diagnosis(3/3) 윤준철.
HEADS OF SERVICES TRAINING
Audiograms Degree, Type and Configuration
Audiological Evaluation A to Z
Sadegh jafarzadeh Ph.D Mashhad university of medical sciences
Objective tests of the auditory system
Equipment for measuring OAE
Hearing Loss Adapted from NYDBC / Susie Morgan.
Presentation transcript:

T HE S OUNDS OF L IFE C ENTER AT U MASS M EMORIAL Current Technique in the Audiologic Evaluation of Infants Todd B. Sauter, M.A., CCC-A Director of Audiology- UMass Memorial Medical Center PhD Candidate – University of Massachusetts Amherst Instructor – Dept. of Otolaryngology University of Massachusetts Medical School

T HE S OUNDS OF L IFE C ENTER AT U MASS M EMORIAL Growing Repertoire of Tools at the Disposal of Audiologist Auditory Brainstem Response (ABR) Auditory Steady-State Response (ASSR) Otoacoustic Emissions (OAE) Multiple Frequency Tympanometry Middle Ear Muscle Reflexes

T HE S OUNDS OF L IFE C ENTER AT U MASS M EMORIAL Questions about Infant Testing by Audiologists (And Others) Questions about Infant Testing by Audiologists (And Others) Which of these tests are most important?Which of these tests are most important? Which of these tests should come first?Which of these tests should come first? Do I have to do all these tests on every child or just one test?Do I have to do all these tests on every child or just one test?

T HE S OUNDS OF L IFE C ENTER AT U MASS M EMORIAL Best Practices in Infant Testing Evidence-BasedClinically Efficient

T HE S OUNDS OF L IFE C ENTER AT U MASS M EMORIAL Overview of Tests

T HE S OUNDS OF L IFE C ENTER AT U MASS M EMORIAL What is an ABR? What is an ABR? The Auditory Brainstem Response is the representation of electrical activity generated by the eighth cranial nerve and brainstem in response to auditory stimulationThe Auditory Brainstem Response is the representation of electrical activity generated by the eighth cranial nerve and brainstem in response to auditory stimulation

T HE S OUNDS OF L IFE C ENTER AT U MASS M EMORIAL How is an ABR recorded? Electrodes are placed on the scalp and coupled via leads to an amplifier and signal averager. EEG activity from the scalp is recorded while the ear(s) are stimulated via earphones with brief clicks or tones.Electrodes are placed on the scalp and coupled via leads to an amplifier and signal averager. EEG activity from the scalp is recorded while the ear(s) are stimulated via earphones with brief clicks or tones. A series of waveforms unique to the auditory neural structures is viewed after time-locking the EEG recording to each auditory stimulus and averaging several thousand recordings.A series of waveforms unique to the auditory neural structures is viewed after time-locking the EEG recording to each auditory stimulus and averaging several thousand recordings.

T HE S OUNDS OF L IFE C ENTER AT U MASS M EMORIAL Example Normal Hearing 18 Month-Old – 2000 Hz Tone-Burst 70 dBnHL 10 dBnHL

T HE S OUNDS OF L IFE C ENTER AT U MASS M EMORIAL Distortion Product Otoacoustic Emissions (DPOAE) Janet Stockard Sullivan 2003

T HE S OUNDS OF L IFE C ENTER AT U MASS M EMORIAL What does the presence or absence of OAEs tell us? Presence = There is no significant conductive loss (no need for bone conduction ABR) and threshold sensitivity is better than ~35 dBHL (except in cases of auditory neuropathy/asynchrony)Presence = There is no significant conductive loss (no need for bone conduction ABR) and threshold sensitivity is better than ~35 dBHL (except in cases of auditory neuropathy/asynchrony) Absence = Possible conductive component and/or sensorineural hearing loss ~35 dBHL or greaterAbsence = Possible conductive component and/or sensorineural hearing loss ~35 dBHL or greater

T HE S OUNDS OF L IFE C ENTER AT U MASS M EMORIAL Tympanometry Janet Stockard Sullivan 2003

T HE S OUNDS OF L IFE C ENTER AT U MASS M EMORIAL What does Tympanometry tell us? If sound energy is being lost in the outer or middle ear due to fluid, vernix, anatomical abnormalities, etc. (conductive component to loss)If sound energy is being lost in the outer or middle ear due to fluid, vernix, anatomical abnormalities, etc. (conductive component to loss) Provides cross-check with bone conductionProvides cross-check with bone conduction Had poor sensitivity in the past due to adult settings being used in infant ears (different!).Had poor sensitivity in the past due to adult settings being used in infant ears (different!). Now more appropriate equipment settings (1000 Hz probe tone) and normative data for infants is available.Now more appropriate equipment settings (1000 Hz probe tone) and normative data for infants is available.

T HE S OUNDS OF L IFE C ENTER AT U MASS M EMORIAL Middle Ear Muscle Reflex Also known as acoustic reflex or stapedial reflexAlso known as acoustic reflex or stapedial reflex Measured using same equipment/probe as tympanometryMeasured using same equipment/probe as tympanometry Looking for sharp reduction in middle ear admittance in response to loud sound due to contraction of middle ear muscles.Looking for sharp reduction in middle ear admittance in response to loud sound due to contraction of middle ear muscles. Should not be present with conductive loss, severe or profound sensorineural hearing loss, or auditory neuropathy/asynchrony.Should not be present with conductive loss, severe or profound sensorineural hearing loss, or auditory neuropathy/asynchrony. Ideally is not used as a stand-alone test, but as a cross- check against ABR, OAE, etc.Ideally is not used as a stand-alone test, but as a cross- check against ABR, OAE, etc. Best elicited in infants using a 1000 Hz probe-tone and broadband noise stimulus.Best elicited in infants using a 1000 Hz probe-tone and broadband noise stimulus.

T HE S OUNDS OF L IFE C ENTER AT U MASS M EMORIAL What is Auditory Steady-State Response (ASSR)? Similar to ABR, but EEG activity is analyzed in frequency domain rather than time domain.Similar to ABR, but EEG activity is analyzed in frequency domain rather than time domain. Stimulus is modulated pure toneStimulus is modulated pure tone If response, EEG activity will modulate at same frequency as the stimulusIf response, EEG activity will modulate at same frequency as the stimulus Statistical computer algorithm determines if response or no responseStatistical computer algorithm determines if response or no response

T HE S OUNDS OF L IFE C ENTER AT U MASS M EMORIAL Advantages of ASSR –Can test up to limits of transducer (through severe/profound range) *** Artifactual results? (See Gorga 2004, Small and Stapells 2004) from stimulus artifact or vestibular system *** Artifactual results? (See Gorga 2004, Small and Stapells 2004) from stimulus artifact or vestibular system –Has potential to be a faster test than ABR when perfected –Some equipment can test multiple frequencies and both ears simultaneously –Uses same basic set-up and equipment as ABR

T HE S OUNDS OF L IFE C ENTER AT U MASS M EMORIAL Limitations of ASSR Cannot analyze raw data, must trust pass/fail criteria given by equipment for each run (can be viewed as advantage) Extremely limited published clinical database (improving) Bone conduction not yet perfected for clinical use (Cant determine conductive vs. sensorineural with ASSR alone) Large threshold estimation range for normal hearing and mild loss (20 db) High intensity steady state stimuli may cause acoustic trauma

T HE S OUNDS OF L IFE C ENTER AT U MASS M EMORIAL What we still need to learn about ASSR Conductive vs. Sensorineural lossConductive vs. Sensorineural loss Effects of auditory asynchrony, retrocochlear disease, etc. on ASSREffects of auditory asynchrony, retrocochlear disease, etc. on ASSR Sedation effectsSedation effects Are responses at very high levels (>100 dB) truly auditory or artifactual?Are responses at very high levels (>100 dB) truly auditory or artifactual? Reliable bone conduction testingReliable bone conduction testing

T HE S OUNDS OF L IFE C ENTER AT U MASS M EMORIAL Gold-Standard: Tone-burst Auditory Brainstem Response Tone-Burst ABR Click ABR OAEASSR High-Frequency Tympanometry Middle Ear Muscle Reflex

T HE S OUNDS OF L IFE C ENTER AT U MASS M EMORIAL Myths about ABR in Infant Threshold Assessment 1.Its too slow 2.It isnt accurate 3.It isnt frequency-specific enough 4.It is difficult to interpret

T HE S OUNDS OF L IFE C ENTER AT U MASS M EMORIAL Myth #1: Its too slow Slow stimulus rates (<20/sec) are not necessary in most patients but are still employed by many centers routinely.Slow stimulus rates (<20/sec) are not necessary in most patients but are still employed by many centers routinely. The click latency-intensity function is not necessary in most patients and results in too much valuable test time being spent testing above threshold.The click latency-intensity function is not necessary in most patients and results in too much valuable test time being spent testing above threshold.

T HE S OUNDS OF L IFE C ENTER AT U MASS M EMORIAL Rate Effects Above Threshold 11.1/sec 39.1/sec 21.1/sec 55.9/sec Time for 4000 sweeps – 6 minutesTime for 4000 sweeps – 3 minutes Time for 4000 sweeps – 1 minute, 42 sec Time for 4000 sweeps – 1 minute, 10 sec

T HE S OUNDS OF L IFE C ENTER AT U MASS M EMORIAL Rate Effects Near Threshold 21.1/sec 39.1/sec 55.9/sec - At low stimulus intensities or near threshold, the early ABR waveforms are absent, while wave V amplitude stays relatively consistent. The use of slow-stimulus rates, in most cases, gains you nothing but longer test times. This is not true in cases of neurological impairment or auditory asynchrony.

T HE S OUNDS OF L IFE C ENTER AT U MASS M EMORIAL Myth #2: It Isnt Accurate A strict review of tone-burst ABR literature with testing done under appropriate parameters found threshold accuracy of ± 5 dB (95 % Confidence Interval) for Hz. (Stapells 2000)A strict review of tone-burst ABR literature with testing done under appropriate parameters found threshold accuracy of ± 5 dB (95 % Confidence Interval) for Hz. (Stapells 2000) Poor accuracy is likely most often associated with either poor technique or attempts to interpret poor dataPoor accuracy is likely most often associated with either poor technique or attempts to interpret poor data

T HE S OUNDS OF L IFE C ENTER AT U MASS M EMORIAL Broadband Click ABR – Poorly Used as Estimate of Hz

T HE S OUNDS OF L IFE C ENTER AT U MASS M EMORIAL Broadband Click ABR – Poorly Used as Estimate of Hz Stapells 1998

T HE S OUNDS OF L IFE C ENTER AT U MASS M EMORIAL Myth #3: It isnt frequency specific enough Stapells 1995

T HE S OUNDS OF L IFE C ENTER AT U MASS M EMORIAL Myth #4: It is Difficult to Interpret - Poor Data - Only Averaged ~ 1000 Sweeps - Difficult to Interpret - Waveforms marked Incorrectly - Clean Data - Averaged Sweeps - True Wave Vs are only significant EEG deflection

T HE S OUNDS OF L IFE C ENTER AT U MASS M EMORIAL Most Common Mistakes in Infant ABR (IMHO) Click stimulus used as estimate of 2-4 KHz Underaveraging of signal Lack of an consistent test sequence algorithm

T HE S OUNDS OF L IFE C ENTER AT U MASS M EMORIAL Sample Test Sequence

T HE S OUNDS OF L IFE C ENTER AT U MASS M EMORIAL Testing Sequence for New Infants Based on answering the most important questions first while the child is asleep:Based on answering the most important questions first while the child is asleep: 1.Is hearing normal at the most important speech intelligibility frequency? 2.Both ears? 3.If hearing is not normal, is it a permanent loss? 4.How severe is it? 5.Other frequencies? ( Hz) 6.If profound loss, is there residual hearing? 7.Could it be Auditory Neuropathy/Asynchrony? 8.Will other tests support the diagnosis?

T HE S OUNDS OF L IFE C ENTER AT U MASS M EMORIAL Testing Sequence 1.Is hearing normal at the most important speech intelligibility frequency? - Low intensity (30 dB) 2000 Hz air-conduction tone burst ABR 2.Both ears? - Get 2000 Hz on each ear before moving on 3.If hearing is not normal, is it a permanent loss? - Get 2000 Hz bone-conduction information early in the testing to determine if loss is conductive or sensorineural in nature. Not necessary if DPOAEs are present.

T HE S OUNDS OF L IFE C ENTER AT U MASS M EMORIAL Testing Sequence 4.How severe is it? - Use aggressive bracketing technique - search in 30 dB intervals before using smaller (5/10 dB) steps to mark threshold 5.Other frequencies? - Use a logical sequence of frequencies to get the most useful information first – 2000 Hz, then 500 Hz, then 4000, etc.

T HE S OUNDS OF L IFE C ENTER AT U MASS M EMORIAL Testing Sequence 6.If profound loss, is there residual hearing? - If no tone-burst response, test click ABR at 90 dB and ASSR up to 115 dB (never this high if DPOAE present) 7.Could it be auditory neuropathy/asynchrony? - Obtain 90 dB slow-rate click ABR at both rarefaction and condensation polarities to look for presence of cochlear microphonic (hair-cell response)

T HE S OUNDS OF L IFE C ENTER AT U MASS M EMORIAL Testing Sequence 8.Will other tests support the diagnosis? - If conductive hearing loss or auditory asynchrony is suspected, cross-check with tympanometry and middle-ear muscle reflexes.

T HE S OUNDS OF L IFE C ENTER AT U MASS M EMORIAL Questions?