Thomas Jefferson National Accelerator Facility Operated by the Southeastern Universities Research Association for the U.S. Dept. Of Energy 1 Spin Dance.

Slides:



Advertisements
Similar presentations
Journées Instrumentation du GDR Nucléon 8-9 Avril 2008, CEA Saclay Polarized Positrons at the Jefferson Laboratory (i) Physics motivations (ii) Principe.
Advertisements

E166 Collaboration Meeting Princeton, May 2006 e+ Analyzing Power K. Peter Schüler e+ Analyzing Power: what we know from old G EANT 3 simulations.
POLARIMETRY of MeV Photons and Positrons Overview Beam Characterization – undulator photons – positrons Basics of the Transmission Method – for photon.
Thomas Jefferson National Accelerator Facility Operated by the Southeastern Universities Research Association for the U.S. Dept. Of Energy 1 Spin Dance.
Hall A Collaboration Meeting S. Nanda, June 23, 2005 Hall A Compton Polarimeter For Hall A Collaboration Meeting June 23 rd 2005 Sirish Nanda Thomas Jefferson.
MADII Design and Physics Program Jian-ping Chen, Jefferson Lab Hall A Collaboration Meeting June 22-23, 2006 MADII Spectrometer Design Optics and background.
Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, Elastic Scattering Parity-Violating Asymmetry PREX : precise measurement of the density -dependence.
Operated by the Southeastern Universities Research Association for the U.S. Depart. Of Energy Thomas Jefferson National Accelerator Facility Strained superlattice.
Low Q 2 Measurement of g 2 and the LT Spin Polarizability A. Camsonne, J. P. Chen Thomas Jefferson National Accelerator Facility Karl J. Slifer University.
Measuring the Neutron and 3 He Spin Structure at Low Q 2 Vincent Sulkosky College of William and Mary, Williamsburg VA Experimental Overview The.
Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, Elastic Scattering Parity-Violating Asymmetry PREX : density -dependence of the symmetry energy. Nuclear.
Measuring the Neutron and 3 He Spin Structure at Low Q 2 Vincent Sulkosky for the JLab Hall A Collaboration College of William and Mary, Williamsburg VA.
The Spin Structure of 3 He and the Neutron at Low Q 2 : A Measurement of the Extended GDH Integral Vincent Sulkosky (for the JLab Hall A Collaboration)
Deeply Virtual Compton Scattering on the neutron with CLAS12 at 11 GeV k k’ q’ GPDs nn’ Silvia Niccolai CLAS12 Workshop, Paris, March 8th 2011.
5 MeV Mott Measurement for CEBAF Operations group Joe Grames, Marcy Stutzman February 14 th, 2007 Sir Nevill F. Mott at the ceremony with his Nobel Prize.
Compton polarimetry for EIC Jefferson Lab Compton Polarimeters.
1 Electron Beam Polarimetry for EIC/eRHIC W. Lorenzon (Michigan) Introduction Polarimetry at HERA Lessons learned from HERA Polarimetry at EIC.
Electron Polarimetry at JLab Dave Gaskell Jefferson Lab Workshop on Precision Electron Beam Polarimetry for the Electron Ion Collider August University.
Future Sino-US Collaboration in QCD Phyics Ten-Year Anniversary of STAR-China Collaboration Haiyan Gao 高海燕 Duke University 1.
EPAC June 2003 The EPAC June 2003 Questions 1. Clarify the Motivation for the Proposal. 2. How to ensure the e+ polarimeter works right away? 3. What is.
The Size and Shape of the Deuteron The deuteron is not a spherical nucleus. In the standard proton-neutron picture of this simplest nucleus, its shape.
M. Woods (SLAC) Beam Diagnostics for test facilities of i)  ii) polarized e+ source January 9 –11, 2002.
AESOP: Accurate Electron Spin Optical Polarimeter Marcy L. Stutzman, Matt Poelker; Jefferson Lab Timothy J. Gay; University of Nebraska.
Precision Electron Beam Polarimetry Wolfgang Lorenzon (Michigan) SPIN 2008 Symposium 6-October 2008.
Proton polarization measurements in π° photo- production --on behalf of the Jefferson Lab Hall C GEp-III and GEp-2 γ collaboration 2010 Annual Fall Meeting.
New Methods for Precision M ø ller Polarimetry Dave Mack Jefferson Lab ( for Dave Gaskell ) May 20, 2006 PAVI06 Precision M ø ller polarimetry Beam kicker.
Polarimetry of Proton Beams at RHIC A.Bazilevsky Summer Students Lectures June 17, 2010.
Thomas Jefferson National Accelerator Facility Page 1 IPR October 18-20, 2011 John J. LeRose Independent Project Review of 12 GeV Upgrade Jefferson Lab.
/SC-PAC Operated by the Southeastern Universities Research Association for the U.S. Depart. Of Energy Joe Grames CEBAF Operations
A study of systematic uncertainties of Compton e-detector at JLab, Hall C and its cross calibration against Moller polarimeter APS April Meeting 2014 Amrendra.
Polarimetry at the LC Source Which type of polarimetry, at which energies for LC ? Sabine Riemann (DESY), LEPOL Group International Workshop on Linear.
Operated by the Southeastern Universities Research Association for the U.S. Depart. Of Energy Thomas Jefferson National Accelerator Facility Strained Superlattice.
Compton polarimetry for EIC Jefferson Lab Compton Polarimeters.
Summary of EIC Electron Polarimetry Workshop August 23-24, 2007 hosted by the University of Michigan (Ann Arbor) Wolfgang.
Thomas Jefferson National Accelerator Facility Operated by the Southeastern Universities Research Association for the U.S. Dept. Of Energy 1 An Overview.
1 Overview of Polarimetry Outline of Talk Polarized Physics Machine-Detector Interface Issues Upstream Polarimeter Downstream Polarimeter Ken Moffeit,
CEBAF The Continuous Electron Beam Accelerating Facility (CEBAF) at JLab in Newport News, Virginia, is used to study the properties of quark matter. CEBAF.
Summary of Workshop on Precision Electron Beam Polarimetry Newport News June 9-10, 2003 workshop summary by Dave Gaskell, Jefferson Lab Richard Jones,
Thomas Jefferson National Accelerator Facility Hall C Commissioning: The Past (1996) First Exp: “by consensus” What Hampton Univ. wanted What ANL wanted.
Thomas Jefferson National Accelerator Facility G0 Collaboration Meeting, June 18-19, 2003 Updates G0 Tiger Laser High Polarization Photocathodes Mott polarimeter.
Fiducial Cuts for the CLAS E5 Data Set K. Greenholt (G.P. Gilfoyle) Department of Physics University of Richmond, Virginia Goal: To generate electron fiducial.
Measuring the Spin Structure of 3 He and the Neutron at Low Q 2 Timothy Holmstrom College of William and Mary For the Jefferson Lab Hall A Collaboration.
Polarized Positrons at the Jefferson Laboratory Idaho State University, Idaho Accelerator Center, Jefferson Lab, LPC Clermont-Ferrand, LPSC Grenoble, Old.
Polarized Positrons at the Jefferson Laboratory Idaho State University, Idaho Accelerator Center, Jefferson Lab, LPC Clermont-Ferrand, LPSC Grenoble, Old.
Compton polarimetry for EIC. Outline Polarized electron beam Compton process Compton polarimeters at Jefferson Laboratory – Parity experiments at Jlab.
Momentum Corrections for E5 Data Set R. Burrell, G.P. Gilfoyle University of Richmond, Physics Department CEBAF The Continuous Electron Beam Accelerating.
Møller Polarimeter Status Update 1.Møller hardware status (detectors and targets) 2.Systematics for SANE 3.Plan Dave Gaskell SANE Collaboration Meeting.
Workshop on Precision Electron Beam Polarimetry for the Electron Ion Collider, University of Michigan, Aug 23-24, 2007 An EIC-like Polarized Electron Injector:
Moller Polarimeter Q-weak: First direct measurement of the weak charge of the proton Nuruzzaman (
Parity Experiments and JLab Injector Riad Suleiman February 5, 2016.
CEBAF Source and Injector Status PREx-II Collaboration Mtg Feb. 26, 2016 Matt Poelker and Joe Grames Center for Injectors and Sources.
Operated by Jefferson Science Associates, LLC for the U.S. Department of Energy Thomas Jefferson National Accelerator Facility Polarized Electron Beams.
Thomas Jefferson National Accelerator Facility Operated by the Southeastern Universities Research Association for the U.S. Depart. Of Energy The Department.
Operated by the Southeastern Universities Research Association for the U.S. Department of Energy Thomas Jefferson National Accelerator Facility Page 1.
Thomas Jefferson National Accelerator Facility Precision Electron Beam Polarimetry Workshop - June , Jefferson Laboratory Accelerator Tools.
Operated by the Southeastern Universities Research Association for the U.S. Depart. Of Energy Thomas Jefferson National Accelerator Facility M. Baylac,
Pb-Parity and Septum Update Presented by: Luis Mercado UMass - Amherst 12/05/2008 Thanks to Robert Michaels, Kent Pachke, Krishna Kumar, Dustin McNulty.
Status of Polarimeters and Polarized Targets: what are the plans for development of polarized targets to meet the needs of the Day 1 and future experimental.
Jefferson Lab Overview
Mott Polarimeter at CEBAF
Polarized Electrons for Polarized Positrons
The Size and Shape of the Deuteron
Overview of Electron Polarimetry
University of Michigan
5 MeV Mott Measurement for CEBAF Operations group
Accelerator Issues Raised in Hall A Parity Collaboration Meeting, April B-Team Meeting April 29, 2009.
Momentum Corrections for E5 Data Set
Polarized Positrons at Jefferson Lab
A Precision Measurement of GEp/GMp with BLAST
PEPPo : Polarized Positron Production
Presentation transcript:

Thomas Jefferson National Accelerator Facility Operated by the Southeastern Universities Research Association for the U.S. Dept. Of Energy 1 Spin Dance 2000 Measurement Joe Grames Hall A Workshop December 10, 2002

Thomas Jefferson National Accelerator Facility Operated by the Southeastern Universities Research Association for the U.S. Dept. Of Energy 2 Jefferson Lab - E. Chudakov, H. Fenker, A. Freyberger, J. Grames, J. Hansknecht, J. Mitchell, M. Poelker, C. Sinclair, M. Steigerwald, M. Tiefenback CEA Saclay, DSM/DAPNIA/SPHN - C. Cavata, S. Escoffier, F. Marie, T. Pussieux, P. Vernin Florida International University - R. Nasseripour, B. Raue Karkov Institute of Physics and Technology - V. Gorbenko Massachusetts Institute of Technology - D. Higinbotham, R. Suleiman North Carolina Ag. and Tech. State University - S. Danagoulian Old Dominion University - V. Dharmawardane University of Virginia - R. Fatemi, K. Joo, M. Zeier Universitaet Bonn - T. Reichelt Vrije Universiteit - B. Zihlmann Jefferson Lab Spin Dance 2000 Collaboration

Thomas Jefferson National Accelerator Facility Operated by the Southeastern Universities Research Association for the U.S. Dept. Of Energy 3 Overview Present and proposed experiments at the worlds polarized electron accelerators invest considerable resources to design, construct, and operate polarimeters to measure the beam polarization. While experiments using polarized targets or recoil polarimetry do not generally require high precision electron polarimeters, this is not the case with parity violation experiments. Some of the planned parity experiments desire absolute knowledge of the beam polarization at the 1% level. Some discussion of Jefferson Labs polarimeters Spin Dance 2000 measurement

Thomas Jefferson National Accelerator Facility Operated by the Southeastern Universities Research Association for the U.S. Dept. Of Energy 4 What are desirable (necessary) features of electron polarimeters? Large total analyzing power Designs with reduced sensitivity to major systematics High luminosity to rapidly achieve small statistical uncertainty Non-invasive continuous measurement does not disrupt experiment N= ·(P b ·P t ·A) 2 P b PbPb 2 Polarimeter Analyzing Power P b ~ 70% A tot ~ 40% Target: 1 m Au = A tot · P b = N + + N - N + - N -

Thomas Jefferson National Accelerator Facility Operated by the Southeastern Universities Research Association for the U.S. Dept. Of Energy 5 Why is A tot difficult to know? Precise knowledge of the analyzing power is limited. A tot is not a directly measured quantity: measurement requires difficult double-scattering experiments the analyzing power is determined by theory and simulation Factors that affect knowledge of the total analyzing power inferred target polarization detector acceptance multiple scattering

Thomas Jefferson National Accelerator Facility Operated by the Southeastern Universities Research Association for the U.S. Dept. Of Energy 6 Jlab Electron Polarimeters

Thomas Jefferson National Accelerator Facility Operated by the Southeastern Universities Research Association for the U.S. Dept. Of Energy 7 The Role Spin Rotation Plays spin = ·· bend 2 ( g-2 ) x z

Thomas Jefferson National Accelerator Facility Operated by the Southeastern Universities Research Association for the U.S. Dept. Of Energy 8 A spin dance example… The measurable component of the beam polarization depends upon the polarimeter, and its design. P meas sin( Wien + ) The Wien angle varies the measurable component of the beam polarization.

Thomas Jefferson National Accelerator Facility Operated by the Southeastern Universities Research Association for the U.S. Dept. Of Energy 9 Source Strained GaAs photocathode ( = 850 nm, P b >75 %) Accelerator 5.7 GeV, 5 pass recirculation The Experiment

Thomas Jefferson National Accelerator Facility Operated by the Southeastern Universities Research Association for the U.S. Dept. Of Energy 10 Spin Dance 2000 Results P meas sin( Wien + )

Thomas Jefferson National Accelerator Facility Operated by the Southeastern Universities Research Association for the U.S. Dept. Of Energy 11 Only statistical uncertainties used to reveal systematic uncertainty. Polarimeters of 3 types (Mott, Moller, Compton) agree. Uncertainty in Wien angle induces < 0.2% relative effect. Relative Analyzing Powers Compared P meas normalized to Mott for reference

Thomas Jefferson National Accelerator Facility Operated by the Southeastern Universities Research Association for the U.S. Dept. Of Energy 12 Spin Based Energy Measurements E = 2mec22mec2 g e - 2 ·

Thomas Jefferson National Accelerator Facility Operated by the Southeastern Universities Research Association for the U.S. Dept. Of Energy 13 Hall B 35 MeV shift? = -2.9° or = -0.22°

Thomas Jefferson National Accelerator Facility Operated by the Southeastern Universities Research Association for the U.S. Dept. Of Energy 14 Jefferson Lab has started down the path of developing high precision polarimetry, which presently can be inferred only by intercomparison of different polarimeters with different systematics using a beam known to have the same polarization for all the polarimeters. The Spin Dance 2000 experiment: First high precision comparison between Mott, Moller, and Compton All five polarimeters do not agree within quoted systematic uncertainty Three different polarimetry techniques (Mott, Moller, Compton) agree Revealing systematic differences is a first step toward understanding them Often, the polarimeter is viewed only as the tool, but to reach the 1% mark it must continue to be the experiment. Conclusions

Thomas Jefferson National Accelerator Facility Operated by the Southeastern Universities Research Association for the U.S. Dept. Of Energy 15 Part of a letter by L.H. Thomas to Goudsmit (25 March 1926). Reproduced from a transparency shown by Goudsmit during his 1971 lecture. The original is presumably in the Goudsmit archive kept by the AIP Center for History of Physics. One last remark...