Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, Elastic Scattering Parity-Violating Asymmetry PREX : density -dependence of the symmetry energy. Nuclear.

Slides:



Advertisements
Similar presentations
PREX PAC 29 Jan 2006 R. Michaels Jefferson Lab Lead ( Pb) Radius Experiment : PREX Z of Weak Interaction : Clean Probe Couples Mainly to Neutrons ( T.W.
Advertisements

R. Michaels PREX at HE06 July 2006 Lead ( Pb) Radius Experiment : PREX Z of Weak Interaction : Clean Probe Couples Mainly to Neutrons ( T.W. Donnelly,
R. Michaels, Jlab Argonne Dec 19, 2011 Lead ( Pb) Radius Experiment : PREX Pb E = 1 GeV, electrons on lead Elastic Scattering Parity.
Lead ( Pb) Radius Experiment : PREX
R. Michaels, Jlab UGM, June, 2011 Lead ( Pb) Radius Experiment : PREX Pb E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry.
Robert Michaels PREX at Trento PREX Workshop 09 Physics Interpretation of PREX 208 Pb E = 1 GeV, electrons on lead Elastic Scattering Parity Violating.
R. Michaels, Jlab Seminar, Apr 27, 2011 Lead ( Pb) Radius Experiment : PREX Pb E = 1 GeV, electrons on lead Elastic Scattering Parity Violating.
Thomas Jefferson National Accelerator Facility
Parity Mtg, 18 May 2007 Bob Michaels Lead Target and Warm Septum Interface Performance of Lead Target during e06007 Radiation for PREX, extrapolated from.
Robert J. Feuerbach Jefferson Lab Constructed from contributions from the HAPPEX Collaboration Hall A Collaboration Meeting December 5, 2005 HAPPEX-II.
Robert Michaels HAMC Hall A Analysis Workshop 09 C HAMC = Hall A Monte Carlo ROOT / C++ Design Somewhat like SAMC & genercone For HRS only. Uses LeRose.
Extraction of G E n at Q 2 =1 (GeV/c) 2 by Measurements of May 1, 2011 Ge Jin University of Virginia.
Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, Elastic Scattering Parity-Violating Asymmetry PREX : precise measurement of the density -dependence.
Measuring the Neutron and 3 He Spin Structure at Low Q 2 Vincent Sulkosky for the JLab Hall A Collaboration College of William and Mary, Williamsburg VA.
R. Michaels PVDIS at Nov 2009 Beam Requirements for PVDIS Property ValueRun-Avg Hel. Correl. 1-Day Hel. Correl. Energy 6 and 4.8 GeVdE/E < 1 ppm < 5 ppm.
1/22 MOLLER Juliette M. Mammei. 2/22 Working Groups Polarized Source Hydrogen Target Spectrometer Integrating Detectors Tracking Detectors Polarized Beam.
Lead ( Pb) Radius Experiment : PREX Pb E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons Paul Souder Krishna.
Noise Analysis for PREx - Pb Radius Experiment Presented by: Luis Mercado UMass - Amherst 6/20/2008.
Parity Violation in Electron Scattering Emlyn Hughes SLAC DOE Review June 2, 2004 *SLAC E122 *SLAC E158 *FUTURE.
PN12 Workshop JLab, Nov 2004 R. Michaels Jefferson Lab Parity Violating Neutron Densities Z of Weak Interaction : Clean Probe Couples Mainly to Neutrons.
PREX PAVI06 May 2006 R. Michaels Jefferson Lab Lead ( Pb) Radius Experiment : PREX Z of Weak Interaction : Clean Probe Couples Mainly to Neutrons ( T.W.
Jefferson Lab, Newport News, VA and the Hall A Collaboration E Spokepersons: K. Aniol, A. Saha, J.M. Udías, G. Urciuoli Students:Juan Carlos Cornejo.
PAC38 August 22, Publications in last year G0The G0 Experiment: Apparatus for Parity-Violating…NIIM A646, 59 E01-107Nuclear transparency and effective.
Polarimetry of Proton Beams at RHIC A.Bazilevsky Summer Students Lectures June 17, 2010.
Collimator June 1-19, 2015HUGS The collimator is placed about 85 cm from the target and intercepts scattered electrons from 0.78° to 3.8° Water cooled.
Opportunities for Precision Measurements, New Physics Searches & Low Energy Fixed Target Expts at a Modified “FEL” Accelerator Complex R. D. Carlini 12/7/2011.
High Precision Measurement of the Proton Charge Radius A. Gasparian NC A&T State University, Greensboro, NC Outline  Previous experiments and proton size.
A study of systematic uncertainties of Compton e-detector at JLab, Hall C and its cross calibration against Moller polarimeter APS April Meeting 2014 Amrendra.
Jin Huang PhD Candidate, MIT For Hall A Collaboration Meeting June 10, JLab.
Contractor Assurance System Peer Review April Page 1 NSTAR 2011 May 16, 2011 Jefferson Lab Hugh Montgomery.
Pb Electroweak Asymmetry in Elastic Electron-Nucleus Scattering -- Weak charge form factor -- most weak charge is carried by neutrons PREX and.
1/33CREX Workshop Jefferson Lab March 16-19, 2013 NASA/CXC/SAO.
PVDIS at JLab 6 GeV Robert Michaels Jefferson Lab On Behalf of the HAPPEX Collaboration Acknowledgement: Talk prepared by Kai Pan (MIT graduate student)
Pb Electroweak Asymmetry in Elastic Electron-Nucleus Scattering : A measure of the neutron distribution PREX and CREX 48 Ca Neutron Skin Horowitz.
PREX Mtg, July 2008R. Michaels, JLab Hall A Monte Carlo -- HAMC Similar to A. Deur’s ``Single Arm Monte Carlo’’ “Fast” Monte Carlo -- not Geant ROOT /
Parity Mtg, 7 Dec 2007 Bob Michaels Test Target for PREX and e06007 (tilted) No “active” cooling, conducts to Loop 3.
Polarimetry Report Sabine Riemann on behalf of the DESY/HUB group January 24, 2008 EUROTeV Annual Meeting, Frascati.
SLAC, September 25, 2009 Searching for a U -boson with a positron beam Bogdan Wojtsekhowski Thomas Jefferson National Accelerator Facility  The light.
MOLLER Collaboration Meeting May 2014 Hall A Update Thia Keppel 1.
Measuring the Spin Structure of 3 He and the Neutron at Low Q 2 Timothy Holmstrom College of William and Mary For the Jefferson Lab Hall A Collaboration.
E Precision Measurement of the Neutron Magnetic Form Factor up to Q 2 =13.5 (GeV/c) 2 by the Ratio Method B. Quinn, J. Annand, R. Gilman, B. Wojtsekhowski.
Coulomb distortions in the Lead Radius Experiment (PREX) Tim Cooper (Univ. College Fraser Valley) C. J. Horowitz (Indiana)
PREX Issues. Outline New issue: souce systematics and Aug. 07 run. Update on old issues. Progress at SU.
R. Michaels PREX at PAVI 09 Lead ( Pb) Radius Experiment : PREX Pb E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.
Thomas Roser Snowmass 2001 June 30 - July 21, 2001 Proton Polarimetry Proton polarimeter reactions RHIC polarimeters.
12 GeV MOLLER U PDATE TO THE H ALL A C OLLABORATION Juliette M. Mammei.
John Leacock April 20, 2009 Qweak: A Precision Test of Standard Model and Determination of Weak Charge of the Proton Four fundamental interactions of the.
Albert Riego, Guillem Cortes, Francisco Calviño July 22 th, 2015 Universitat Politecnica de Catalunya, Barcelona (Spain) Third BRIKEN WORKSHOP – IFIC (Valencia,
PV e Fisica oltre il Modello Standard: PREX, SOLID, MOLLER, HPS G.M. Urciuoli.
Hall A Update Thia Keppel User Group Board of Directors January 2015.
Hall A Collab. Mtg, 6/ 2010R. Michaels, JLAB Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, Elastic Scattering Parity-Violating Asymmetry PREX : precise.
Pb-Parity and Septum Update Presented by: Luis Mercado UMass - Amherst 12/05/2008 Thanks to Robert Michaels, Kent Pachke, Krishna Kumar, Dustin McNulty.
Polarized Injector Update
Jefferson Lab Overview
Sanghwa Park (Stony Brook) for the PREX/CREX Collaboration
D. J. Margaziotis HAPPEX Collaboration Meeting
The G0 experiment at JLAB
G0 Accelerator Planning Meeting (11/1/05)
Noise Analysis for PREx - Pb Radius Experiment
Accelerator Issues Raised in Hall A Parity Collaboration Meeting, April B-Team Meeting April 29, 2009.
PREX: Lead / Diamond Target
Lead ( Pb) Radius Experiment : PREX
View from Lab Management HPS Collaboration Meeting
Hall C – this week Time Period Plans 10/24-10/27 Target cool down
Physics Interpretation of PREX
Beam Dump Experiments with Photon and Electron Beams
PREX / CREX Collaboration Meeting and Status
Parity – Violating Neutron Density Measurements : PREX, C-REX
Measurement of Parity-Violation in the N→△ Transition During Qweak
Presentation transcript:

Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, Elastic Scattering Parity-Violating Asymmetry PREX : density -dependence of the symmetry energy. Nuclear physics community very interested in this ! Z 0 : Clean Probe Couples Mainly to Neutrons Nuclear Theory F N (Q 2 ) ( Dany Page ) Obtained 20% statistics Main problem: radiation degradation of vacuum seals and HRS controls systems Applications : Nuclear Physics, Neutron Stars, Atomic Parity, Heavy Ion Collisions Ran Mar 19 – June 20, 2010 Accomplishments : Statistics limited, negligible noise Pb target ran at 50 uA with last 3 days at 70 uA Precision Compton and Moller polarimetry (1.5%) Thin quartz detector for high rates (1 GHz) Septum magnet at high luminosity : low-current cavity monitors, GEM detectors

Blinded Asymmetry slug ~ 1 day Plan to release results at April 2011 APS meeting. Expect dR N / R N ~ 2.5% ( Ultimate goal : 1% ) Proposed new measurements with fixes to vacuum system and shielding Last 3 70 uA promising : 125 ppm detector Hz equiv. flip rate Raster synched to flip rate to reduce noise due to target. Transverse asymmetry A T < 2 ppm (product of Wien flip and IHWP flip) Good chi-square: data are statistical Lessons of PREX PREX Physics Asymmetry vs Data Set Run-averaged asymmetry placed at 1.0 (approx ppm) for presentation. ½ our data; the sign flips with Wien x IHWP flip All data. Sign flips removed

Apparatus was assembled correctly at the 1 mm level.

Kiads HAPLOG 2450 : We were underbending by 5 mrad, need to run 760 A septum (was 729 A) Non-optimal Q 2 Problem: Missing acceptance. Q 2 pushed high

(thanks, Bogdan W.) R. Michaels, Oct 2010 Need GEANT simulations to design the shielding Need engineering and design support.

Using HAMC (Monte Carlo) to predict a future running point. How good is HAMC ? 1 - HRS Keep apparatus same Run 775 A E beam = 925 to 1000 MeV

Future Run of PREX

Lead / Diamond Target Seem to melt after ~1 week We melted two targets A third ran for 4 days at 70 uA. Strategy ? Run with ~12 targets 6 lead/diamond 6 lead/carbon (carbon more robust)

PREX: Things to Do / Conclusions 12 GeV run ? Thinking: Oct – Dec 2013 Hall A Commissioning. Asking for 8 to 10 weeks. Go to PAC in Dec Assuming approval : In ~12 month period prior to experiment: Re-design beamline to withstand radiation & thermal cycling. Design radiation shielding to protect equipment. Minor mods to targets ( try Pb/carbon, add more targets). dR N /R N = 1 %