MNS Sprint - A Market Driven Solution

Slides:



Advertisements
Similar presentations
Medium-Voltage Switchgear - Then and Now -
Advertisements

Gdpack 40.5kV Technical Data Sheet MV-LV Prefabricated Substation
SHS2 Gas insulated switch–disconnector / isolator
Arc-Killer SV-25 – DF-2 + Range Arc-Killer SV-25 - DF-2 + Range.
Premset : A New generation of MV Switchgear
Copyright © 2011 Rockwell Automation, Inc. All rights reserved. Insert Photo Here OneGear™ 7.2kV Motor Control Center.
ATEC-Produktmanagement / Dietrich Probst OEM key account manager start saving fuel and make a contribution for climate protection in your own home.
FIPTMV Medium Voltage Technology
Frankfurt (Germany), 6-9 June 2011 Coordination between TSOs and DSOs – a necessity for system planning and operation Dr. Ralph Pfeiffer Amprion GmbH 1.
December, 2010 Vmax – Indoor vacuum circuit-breakers for Primary Distribution Product presentation 1VCP – Rev. D, en – Presentation –
ABB - 1- ABB ABB Load Interrupter Switchgear. ABB - 2 ABB Contents Introduction to Load Interrupter Switchgear What, Where, Why ABB Technical Offering.
Power Factor Correction and Filtering : LV offer Give oxygen to your electrical network.
ABB Connectivity & Smart Grid Ahmed Fahmy,Senior Technical Promoter Novmber 2014 NEMA technical workshop.
VHA PANEL WITH HPA12 CIRCUIT BREAKER
SF6 load-break switch-disconnector
Breaker Basics Welcome to this general overview of ABB.
EE4503 Electrical Systems Design
Multi-function apparatus for secondary distribution
Medium Voltage Switchgear
UniGear ZVC Standard Product
EDIA DIVISION Titre de la présentation en Arial, 45 Alpican capacitors F.Dupré 09/11/2012.
Motor Control Center MNS iS with Condition Monitoring
WHO WANTS TO BE A MILLIONAIRE?
Pole Mounted Switch Disconnector NPS
Electrical Installation 2
Frankfurt (Germany), 6-9 June 2011 V Ramesh – India – Session 1: Network components – 1096 Integrated Switching Devices (ISD) V.RAMESH ABB Limited, Nashik,
CHENDIAN SCIENCE&TECHNOLOGIES CO.,LTD Tel/Fax: Website: www. Chinacdm.com.cn
Module 5, Unit A Vocabulary Review Game. 2 pt 3 pt 4 pt 5pt 1 pt 2 pt 3 pt 4 pt 5 pt 1 pt 2pt 3 pt 4pt 5 pt 1pt 2pt 3 pt 4 pt 5 pt 1 pt 2 pt 3 pt 4pt.
All rights reserved Gas-insulated Switchgear (GIS)
All rights reserved MV SWITCHGEAR.
Circuit Master Circuit Master™ uses three PROVEN technologies* – Capacitor (reduces DEMAND) – Harmonic Filter (harmful frequencies) – Surge Protection.
A low - cost high performance MV RMU with circuit breakers for use in remote controlled MV / LV substations Fabio GIAMMANCO Luca GIANSANTE 1 1.
Copyright © 2011 Rockwell Automation, Inc. All rights reserved. Insert Photo Here OneGear™ SMC™ Flex Controller kV.
Reyrolle LMT Breaker Retrofit BU PPMV – PG Service Marketing and Sales
Power Plant Construction and QA/QC Section 4.4 – In-Plant Electrical Distribution Engineering Technology Division.
PowerIT Air Insulated Cubicle Uniswitch
© ABB Schaltanlagentechnik - 12/21/2015 Optimizing System Performance Protect IT – MNS Motor Management INSUM.
132KV GSS PIPAR CITY JODHPUR
1 Pacini IT Barcelona May 2003 Improvement in the Distribution Assets Management by the Exploitation of the Innovative Component Technology.
Craig T. Riesen Energy Workshop II 1 Electricity & Generation Basics of Electricity and Electrical Transmission Transmission Generation electrons.
This project on Primary sub station of Visakhapatnam port trust at Visakhapatnam. It is 132kv/11kv substation with incoming feeder from APTransco and 11.
5SL4 10 kA / 5SL6 6 kA miniature circuit breakers
OEZ s.r.o. Quick and universal solution for your order Modeion 05/2012.
KAIST NUCLEAR & QAUNTUM NICIEL SEMINAR 1 / 23 Review on Power Factor Young Seung LEE 04/26/2005 SEMINAR.
© ABB Schaltanlagentechnik TGC900003N AH Licensing MNS Coordinated solutions, systems & products for your business.
POWER FACTOR CORRECTION
Comparison of AIS and GIS Grid Station Muhammad Ali Ashraf Management Associate (Electrical) CPP Project.
Power Factor Correction The Definitive power solution
v1/2011 Strikesorb Protection Solutions
Low Voltage Systems MNS iS with MSpeed Technical Introduction
Power Factor Correction The Definitive power solution
Effects of Harmonics on Capacitors Electrical System
Sensor presentation.
POWER FACTOR CORRECTION
Management Of Tulkarm Electrical Network
Sensor presentation.
Transmission Solutions
Power distribution and UPS in a single, compact system
Name, department/event, date
Overview of PowerCube Units and ANSI frames
Oil-tight MV fuse CEF-OT with TPC bushings
Low Voltage Products division
ABB SACE Emax 2 ANSI C37 / UL1066 Concept Global Product Management
Friday, December 28, 2018 ABB SACE Emax 2 Concept
All rights reserved Gas-insulated Switchgear (GIS)
The smart choice for demanding motor switching
Its strengths, your benefits
Its strengths, your benefits
Presentation transcript:

MNS Sprint - A Market Driven Solution Power IT - Low Voltage Switchgear MNS Sprint

MNS Sprint for industrial applications

MNS Sprint for building applications

MNS Sprint for building applications

Low voltage switchgear

Functional compartments

Frame and busbar systems

Busbar systems

Circuit breaker cubicle

Variants MNS Sprint Direct feeder Motor starter Energy distribution Modules up to 132 kW fused and fuseless Coordination acc. 35 kA, Typ 1 Connection to a control system possible Rated current up to 2300 A Air circuit breaker and moulded case circuit breaker available Connection to a control system possible M MNS Sprint Energy distribution Reactive power compensation Regler Modules up to 630 A Fused and fuseless Compact design Fuse switch disconnectors Smissline S-System Modules with reactor up to 25 kvar Modules without reactor up to 50 kvar Microprocessor-based control unit

Circuit breaker Air circuit breaker Moulded case circuit breaker ABB Sace circuit breaker are equipped with a microprocessor- based release Simple linking to a control system

Emax - Overcurrent release

Energy distribution

Compact Two main switching devices on a base plate Up to 2 x 230 A per module Up to 24 feeder per cubicle Compact design for high currents

Professional Very compact design for energy distribution with low currents Up to 36 one-pole MCBs with max. 63 A per module or: Up to 6 three-pole motor pro-tection switches with max. 45 A per module

Fuse switch disconnectors One- or three-pole operated Sizes: 00: 160 A 1 : 250 A 2 : 400 A 3 : 630 A Very economic solution for energy distribution up to 630 A Up to 24 devices of size 00 can be build into a cubicle. Up to 10 devices of sizes 1, 2 or 3 can be build into a cubicle.

Fuse switch disconnectors in the cubicle

Integration of the Smissline S-System

Range of motor starters

Motor starter

Exchanging of modules

Reactive power compensation

Reasons for reactive power compensation kWh P S QEVU QC kvarh Saving costs by transferring a higher amount of active power, or relieving transmission lines and plants (transformers, generators) reduced dimensioning of all transmission elements reducing heat losses and voltage drops no consumption of primary energy to provide reactive power

Cost savings with RPC Tariff: 0.25 DM/kWh tan  = Q / P > 0.5 ( cos  > 0.89 ind.) Overconsumption: 15% (active power consumtion) Example: Without compensation cos  = 0.7 100 000 kWh · tan ( arccos 0.7 ) = 102 020 kvarh Customer pays for: 102 020 kvarh - ( 0.5 · 100 000 kWh ) = 52 020 kvarh With compensation cos  = 0.9 12 x 52 020 kvarh x 0.15 x 0.25 DM/kvarh = 23 409 DM/year => cost reduction of 23 409 DM/year through reactive power compensation

Technical data Standards IEC 439-1 Electrical Characteristics Rated insulation voltage Ui < 1000 VAC Rated operational voltage Ue < 400 - 690 VAC Rated frequence 50/60 Hz Horizontal Busbar System/Vertical Busbar System Rated current Ie < 2000 / 1250 A Rated impulse withstand current Ipk < 165 / 73,5 kA Rated short-time withstand current Icw < 75 / 35 kA (1 s) Degree of protection IP00 ... IP54 Standard colour RAL 7035 Dimensions Heigh 2200 mm, Width 400, 600, 800, 1000, 1400 mm, Depth 400 mm Material Enclosures Aluzinc or zinc-galv. sheet steel Busbars Copper

Characteristics MNS Sprint Safety Economic viability Flexibility Type tested switchgear assembly in acc. with IEC 439-1 Arc proofed for 35 kA (440 V; 0,1 s) acc. IEC 1641 Carrying out routine tests for each switchgear Operational safety thanks to position of the main busbar system in the rear section of the switchgear Compact design Optimized for buildings and industrial applications Easy engineering and industrial production with high volumes due to standardized assemblies Reduction of operating cost through reactive power compensation MNS Sprint Flexibility Reliability Modular design Comprehensive product range Optimal adaptability to customer specific operational and environmental conditions Easy to refit and modify with insulated distribution bars Combination with MNS cubicles possible Experience with more than 500.000 MNS cubicles sold worldwide Top-quality electrical and mechanical components High corrosion resistance Maintenance-free mechanical connections Certification in acc. with ISO 9001