FRET-Introduction FRET involves the transfer of energy from an excited donor fluorophore to an adjacent acceptor fluorophore. We use CFP and YFP, two color.

Slides:



Advertisements
Similar presentations
Three common mechanisms for bimolecular quenching
Advertisements

Biology Mathematics Engineering Optics Physics Robotics Informatics.
ABSTRACT Fluorescence Confocal Microscopy (FCM) is nowadays one of the most important tools in biomedicine research. In fact, it makes possible to accurately.
Fluorophores bound to the specimen surface and those in the surrounding medium exist in an equilibrium state. When these molecules are excited and detected.
Special Applications in Fluorescence Spectroscopy Miklós Nyitrai; 2007 March 14.
Oligonucleotides – Primers and Probes by … as quality counts! Competence and Service in Molecular Biology metabion´s history.
Study of Protein Association by Fluorescence-based Methods Kristin Michalski UWM RET Intern In association with Professor Vali Raicu.
Fluorescence Microscopy Chelsea Aitken Peter Aspinall.
1 QED In Vivo USB Input Output Box configuration This tutorial contains a number of instructions embedded in a great deal of explanation. Procedures that.
Practical aspects of fluorescence microscopy
Illumination and Filters Foundations of Microscopy Series Amanda Combs Advanced Instrumentation and Physics.
Are You FRETting? Find Out for Sure With FLIM Frequency Domain FLIM for Your Scope Intelligent Imaging Innovations.
FRET(Fluorescent Resonance Energy Transfer)
Fluorescence Techniques
Cell nucleus GFP flow analysis from sequences of LSCFM images Isabel Rodrigues 1,2 and João Sanches 2,3
Lecture 7: Fluorescence: Polarization and FRET Bioc 5085 March 31, 2014.
Miriam Israelowitz 1 and Dr. David L. Wilson 2 1 Department of Physics, Case Western Reserve University, Cleveland OH, 2 Deparment of Biomedical Engineering,
Chapter 15 Molecular Luminescence Spectrometry Three types of Luminescence methods are: (i) molecular fluorescence (ii) phosphorescence (iii) chemiluminescence.
Powerpoint Templates Page 1 Powerpoint Templates Spectroscopic Microscopy.
Scanning excitation and emission spectra I Wavelength (nm) )Scan excitation with emission set at 380 nm -λ ex,max = 280 nm 2) Scan emission.
1 Introduction to Atomic Spectroscopy Lecture 10.
Spectroscopy images GiGi Gs Globals by Enrico Gratton The Globals program originally developed at the LFD for analysis of multiple files from spectroscopy.
The Plasmamembrane and Lipid Rafts 08/2007 Lecture by Dr. Dirk Lang Dept. of Human Biology UCT Medical School Room Phone:
Today’s Announcements 1.Next Tuesday: Diffusion (Why moving in a cell is like swimming in concrete.) 2. Homework assigned today Last graded Homework:
Förster Resonance Energy Transfer (FRET)
FRET 발표자 최예림.
IPC Friedrich-Schiller-Universität Jena 1 Radiationless excitation energy transfer requires interaction between donor and acceptor  Emission spectrum.
Introduction to Digital Image Analysis Kurt Thorn NIC.
Computer Graphics CC416 Lecture 04: Bresenham Line Algorithm & Mid-point circle algorithm Dr. Manal Helal – Fall 2014.
FRET and Biosensors Kurt Thorn Nikon Imaging Center Image: Thomas Huckaba.
Date of download: 6/28/2016 Copyright © 2016 SPIE. All rights reserved. Image collection and region of interest assignment. Four channels were collected.
Date of download: 7/7/2016 Copyright © 2016 SPIE. All rights reserved. The spectral overlap of Cerulean or mTFP with Venus is compared. The excitation.
Date of download: 7/8/2016 Copyright © 2016 SPIE. All rights reserved. Schematic representations of the HP1α and C/EBPα proteins indicating the relative.
Date of download: 7/22/2016 Copyright © 2016 SPIE. All rights reserved. The diffusional mobilities of Venus-LC3 and Venus-Atg4BC74A in both the cytoplasm.
Measurement Methods in Systems Biology
Figure 5. A model for rolling-circle amplification of telomeres
Measuring Fluorescence Resonance Energy Transfer in vivo
Statistical Analysis with Excel
Statistical Analysis with Excel
Reliable and Global Measurement of Fluorescence Resonance Energy Transfer Using Fluorescence Microscopes  Zongping Xia, Yuechueng Liu  Biophysical Journal 
Statistical Analysis with Excel
Dual Modes of Cdc42 Recycling Fine-Tune Polarized Morphogenesis
Today’s take-home lessons: FRET (i. e
Photobleaching-Corrected FRET Efficiency Imaging of Live Cells
New Turf for CFP/YFP FRET Imaging of Membrane Signaling Molecules
Fluorescence Applications in Molecular Neurobiology
Dynamics of interphase microtubules in Schizosaccharomyces pombe
Förster Resonance Energy Transfer (FRET)
Florian Mueller, Tatsuya Morisaki, Davide Mazza, James G. McNally 
Raibatak Das, Stephanie Hammond, David Holowka, Barbara Baird 
Research Techniques Made Simple: Methodology and Applications of Förster Resonance Energy Transfer (FRET) Microscopy  Joshua A. Broussard, Kathleen J.
New Turf for CFP/YFP FRET Imaging of Membrane Signaling Molecules
Single-Molecule Microscopy Reveals Plasma Membrane Microdomains Created by Protein-Protein Networks that Exclude or Trap Signaling Molecules in T Cells 
Localization of ASH1 mRNA Particles in Living Yeast
Volume 13, Issue 2, Pages (January 2003)
Membrane Hemifusion Is a Stable Intermediate of Exocytosis
Quantifying the Interaction between EGFR Dimers and Grb2 in Live Cells
The Bacterial Cytoskeleton
Determinants of S. cerevisiae Dynein Localization and Activation
Eugenia Y. Xu, Karl A. Zawadzki, James R. Broach  Molecular Cell 
Volume 31, Issue 6, Pages (September 2001)
Cytotoxic T Lymphocyte Antigen-4 Accumulation in the Immunological Synapse Is Regulated by TCR Signal Strength  Jackson G. Egen, James P. Allison  Immunity 
Single-Molecule Three-Color FRET
Volume 18, Issue 1, Pages (April 2005)
Polarized Fluorescence Resonance Energy Transfer Microscopy
Volume 17, Issue 7, Pages (July 2010)
Mobility of Synaptic Vesicles in Different Pools in Resting and Stimulated Frog Motor Nerve Terminals  Michael A. Gaffield, Silvio O. Rizzoli, William.
Marko Kaksonen, Yidi Sun, David G. Drubin  Cell 
Self-Organization of Minimal Anaphase Spindle Midzone Bundles
Elena Oancea, Tobias Meyer  Cell 
Presentation transcript:

FRET-Introduction FRET involves the transfer of energy from an excited donor fluorophore to an adjacent acceptor fluorophore. We use CFP and YFP, two color variants of GFP, as donor and acceptor. Two proteins are tagged as described elsewhere. We measure fluorescence by microscopy and define the CFP and YFP channels as the standard filter combinations used for visualization.elsewhere

During the lifetime of the excited state of CFP an energy field is created by the oscillation of the excited state electron. YFP can be excited through resonance with this energy field. For the transfer of energy to occur the fluorophore to fluorophore distance must be within approximately 100 angstroms. The distance requirement is described by the Forster equation for the efficiency of transfer: Given that the Ro for the CFP-YFP combination is 49 angstroms: In practice we have found that the fluorophore to fluorophore distance must be less than 70 angstroms to be detected by our methods.

To examine FRET between two tagged proteins CFP is excited with CFP excitation filter and the emission from YFP is captured using the YFP emission filter. We call this filter combination the FRET channel.

There are two problems that are encountered when using CFP and YFP as FRET partners. First the FRET channel is polluted with fluorescence spilling over from CFP. Even when CFP is expressed alone a certain amount of fluorescence is observed in the FRET channel. However we quantify the amount of fluorescence in the FRETchannel when CFP is expressed alone and define a spillover factor:

In addition the FRET channel is polluted by some direct excitation of YFP. Just as in the case with CFP, even when YFP is expressed alone a certain amount of fluorescence is observed in the FRET channel. Again, we quantify the amount of fluorescence in the FRETchannel when YFP is expressed alone and define a spillover factor:

Let's return to the FRET experiment: We have two proteins tagged with YFP and CFP and co-expressed in the cell. We acquire images from the 3 channels in the order shown. In practice we have found that the order of acquisition is important because YFP rapidly bleaches when exposed to the CFP excitation light. From the CFP and YFP channel data we calculate the total fluorescence expected in the FRET channel from spillover:YFP rapidly bleaches FRET is then measured as the relative increase in the FRET channel over the expected background from spillover: If there is no FRET then FRETR is 1. The maximum FRETR we have observed is approximately 2.5 for positive controls in which a protein is tagged with CFP and YFP in tandem using plasmid pDH18. plasmid pDH18

Microscope Base: Set up for Differential Interference Contrast (DIC) Observation Objectives: UPlanApo/100X 1.35 Oil; UPlanApo/60X 1.40 Oil Immersion Oil: Applied Precision, N=1.514 Camera: Photometrics CoolSNAP HQ, Hammatsu Orca IIPhotometrics CoolSNAP HQ Light Source: OSRAM HBO 100W/2, Mercury Short Arc Lamp. We replace the lamp when it has more than hours of usage or the YFP photosensor values are less than 550,000. Excitation Filters: XF1071 (440AF21); XF1068 (500AF25) Emission Filters: XF3075 (480AF30); XF3074 (545AF35) Dichroic: XF2065 ( DBDR) All filters from Omega Optical or ChromaOmega Optical Temperature Controlled Growth: Bioptechs Objective Heater and Controller Model FCS2, Closed Chamber System Controller, Model FCS3. Typically live cells are kept at room temperature. The Bioptechs controllers are used for temperature-sensitive mutants where temperature needs to be tightly regulated. We use the 60X objective with the protective sleeve removed for this purpose.Bioptechs Objective Heater and Controller Model FCS2, Closed Chamber System Controller, Model FCS3

We tag proteins with CFP and YFP using the procedure described elsewhere on the web site. The tagged proteins are expressed under the control of their own promoter. They fully replace the wild-type, untagged protein. There is no wild-type gene. This means that for an essential protein the tagged version is functional.described elsewhere on the web site On the day before image acquisition, fresh cells are plated on YPD supplemented with 3X adenine and grown at 30 C. The addition of extra adenine eliminates the red pigment that would otherwise accumulate in our ade2 strains. The next day colonies the size of pin heads are scraped up together and resuspended in 30 ul of SD media. There is no need for sonication before visualization since cell separation is complete under these conditions. A 3 ul aliquot is placed on a 1% SDC low melt agarose pad on a microsope slide. The preparation of the slide is presented on the next few pages.YPD supplemented with 3X adeninered pigmentSD media

Before proceeding with our general acquisition parameters several properties of YFP and CFP need to be introduced. First, CFP and YFP photobleach much more rapidly than GFP. After six repetitions of 0.25 second exposures (a total of just 1.5 seconds!) CFP fluorescence is reduced 50%. YFP is more stable, as it takes 6.5 seconds of total exposure to diminish the signal intensity to 50%. The rapid photobleaching of CFP requires that exposure times be kept to a minimum. In practice we have found that in FRET experiments 0.4 second exposure times are optimum. The only exception is for very bright signals where the exposure times can be reduced further. The other practical point is that fluorescence is never examined by eye before acquisition by the camera.

One other property of YFP dictates the order of image acquisition. YFP is rapidly photobleached when excited with the CFP excitation energy. Thus in our FRET experiment YFP must be imaged first, followed by the FRET channel (CFP excitation, YFP emission) and finally the CFP channel.

The precise details for acquistion will depend on the microscope. We illustrate with screen captures from our DeltaVision microscope running Softworx. Our typical experimental protocol is shown here. We image with the 100X objective, the camera is set for 2 x 2 binning, 3 sequential 0.4 second exposures capture the YFP, FRET and CFP channels and finally a 0.05 second DIC image is captured.

Just as for image acquisition, the details for image analysis will depend on the image analysis software. We demonstrate our analysis using the Softworx program that is part of our DeltaVision system. The first step is to determine the Spillover factors described in the Introduction. This is accomplished by imaging two strains in which one of your proteins of interest is tagged with either YFP or CFP alone. For example we demonstrate how we determined the YFP Spillover factor for a spindle pole body (SPB) component. In the image below, Spc110 is tagged with YFP. No other fluorescent protein is labeled. We had run the FRET acquisition series and acquired 4 bundled images, just as if we were examining FRET between a pair of proteins. In the left strip the depressed and highlighted "545" button displays the YFP channel. The Data Inspector panel allows us to create a 5 x 5 pixel box that encompasses the image of the SPB. The pixel intensity data is saved to a space delimited text output file.DeltaVision systemIntroductionFRET acquisition series

The next step is to select an appropriate 5 x 5 pixel background box. The choice of a background region is a critical step. In the case of the SPB we first examine the DIC image, below, to orient the position of the selection box. The background region will be an adjacent square within the cell, as shown in the next web page. If the protein had a diffuse nuclear pattern, an adjacent region in the cytoplasm would be chosen. The most challenging case is a signal that is present throughout the cell. In that case we mix in isogenic cells without a label and use a region in an adjacent cell as background. The choice of background requires your best judgement. One check on the choice of background is that a negative control for FRET will have a FRETR value different from the expected value of 1.00.

The process of collecting a YFP image, a YFP background image, a FRET image and a FRET background image is repeated approximately 60 times. With as little as 40 separate data points a reasonable average value can be calculated, but in general 60 narrows the standard deviation. In the end a text file is generated that will have all the data for the objects (in this case 60 different SPBs) in groups of 4, as shown, in part, below.

The data text file is manipulated to remove extraneous data and restructure the format to yield the following Microsoft Excel spreadsheet. We have created a Perl script to automate the process for our DeltaVision files. The Perl script will be available soon. However the manipulations can also be done through basic cutting and pasting in a word processor program and Excel. Columns A - D are the sum of the intensity values in the 5 x 5 pixel box. The YFP and FRET columns are the background subtracted total intensity values. YFP Spillover factor is calculated by dividing the FRET values by the YFP values. The average and standard deviation are then computed.

The CFP Spillover factor is calculated in the same manner, except the YFP tag is replaced by CFP. How often to measure the Spillover factors? The factors will reflect changes in light intensity due to the age of mercury lamp, so it is a good idea to measure the spillover factors over the lifetime of the lamp. By tracking photosensor values and changing the bulb after 100 hours of use one can minimize the change in spillover factors, as well as keep the images bright. Once the factors are available FRETR can be evaluated.

In the FRET experiment two proteins are labeled, one with CFP and one with YFP. The FRETR value will indicate whether the fluorescent proteins are in close proximity and by implication the two tagged proteins are adjacent, i.e. within 70 angstroms. Image capture and and the initial analysis is the same as described in earlier web pages. A text file is created that has the intensity values for the YFP, YFP background, FRET, FRET background, CFP and CFP background. An example is shown in the next 2 pages.i.e. within 70 angstroms.

FRETR is not a direct measure of the amount or efficiency of energy transfer. FRETR is a relative and empirical measure of energy transfer. FRETR equals the relative increase in the amount of light in the FRET channel when compared to an expected baseline determined from the fluorescence in the YFP and CFP channels. In order to best interpret FRETR one creates a positive control. The positive control is constructed with pDH18 and creates a strain in which one of the proteins of interest is fused to a tandem YFP-CFP tag. In practice we have found that FRETR for our positive controls are typically 2.50 with a % standard deviation. If an experimental pair of proteins yields a FRETR of greater than 2 than the proteins are in close proximity to each other. Of course, since FRETR is an empircal measure biased in part by fluorescence filters, camera specifications and the experimental set up, the value for the positive control may be higher or lower.pDH18 What is the lower limit of detection? To push the sensitivity of FRETR one needs a carefully chosen negative control. This would be a pair of proteins which a priori one knows are too distant from each other (> 100 angstroms) to FRET. One can then verify that the methodology and spillover factors return the expected FRETR value of In this case we have seen that FRETR values as low as 1.07 can represent energy transfer. In the absence of negative controls certainly values of 1.20 and higher represent energy transfer, assuming a positive control of 2.5.

Fluorescence resonance/Förster energy transfer (FRET) is the radiationless transfer of energy between two molecules, which can occur if they are very close to each other (< 10 nm), see Fig.6. Therefore FRET makes it possible to measure if two molecules, for example a ligand and a receptor, interact with eachother. For FRET to happen the fluorescence emission spectrum of the donor has to overlap with the adsorption spectrum of the acceptor and the donor and acceptor transition dipole orientations must be approximately parallell. The transfer can be measured by looking at the quenching of fluorescence of the donor in presence and absence of the acceptor, or by excitation of the donor and then looking at the fluorescence of the acceptor. Fig.6 Upper Left: The acceptor and donor fluorophores must be closer than ~ 10 nm for the energy transfer to occur. Lower Left: The emission spectrum of the donor must overlap with the excitation spectrum of the acceptor. Right: An example of the acceptor bleaching FRET technique with CFP as the donor and YFP as the acceptor.

Fluorescence Recovery After Photobleaching (FRAP) is the recovery of fluorescence in a defined region of interest (ROI) of a sample after a bleaching event, see Fig.5. FRAP results from the movement of unbleached fluorophores from the surroundings into the bleached area. FRAP is used to measure the dynamics of 2D or 3D molecular mobility e.g. diffusion, transport or any other kind of movement of fluorescently labeled molecules in membranes or in living cells. The recovery time (half-recovery time) indicates the speed of this mobility, e.g. diffusion time. A related method is FLIP (Fluorescence Loss in Photobleaching), which is the decrease/disappearance of fluorescence in a defined region adjacent to a repetitively bleached region. Like FRAP, FLIP is used to measure the dynamics of molecular mobility in membranes or in living cells. Fig.5 Upper Left: Images of a live cell prebleach, postbleach and after five minutes. Lower Left: Corresponding images of a fixed cell. Right: The FRAP curve gives information about the mobility of a molecule and the fraction of immobile species.