1 Shell-and-Tube Heat Exchangers Shell-and-Tube Heat Exchangers Choose of the right TEMA type and decide which stream goes in the tubes By:A.Behzadi.

Slides:



Advertisements
Similar presentations
Chapter 18 ChEN 4253 Terry A. Ring
Advertisements

HEAT EXCHANGER GUIDED BY: PREPARED BY:
Heat Exchangers Design Considerations. Heat Exchangers Key Concepts Heat Transfer Coefficients Naming Shell and Tube Exchangers Safety In Design of Exchangers.
Basic construction Concepts
Convection in Flat Plate Turbulent Boundary Layers P M V Subbarao Associate Professor Mechanical Engineering Department IIT Delhi An Extra Effect For.
Shell-and-Tube Heat Exchangers
ME421 Heat Exchanger and Steam Generator Design Lecture Notes 7 Part 1 Shell-and-Tube Heat Exchangers.
Kern’s Description of Shell Side Flow in SHELL-AND-TUBE HEAT EXCHANGER P M V Subbarao Professor Mechanical Engineering Department I I T Delhi Another.
Blue-OX Energy Management TJ Chancellor Paul Cole Sara Habib Mira Kim Claudio Ramos Vicente Rosas.
 A 'heat exchanger' may be defined as an equipment which transfers the energy from a hot fluid to a cold fluid. Here, the process of heating or cooling.
Types of Heat Exchangers
Kern Method of SHELL-AND-TUBE HEAT EXCHANGER Analysis
Closure of Kern’s Method
Kern’s Description of Shell Side Flow in SHELL-AND-TUBE HEAT EXCHANGER
SHELL-AND-TUBE HEAT EXCHANGERS
Heat Convection : Cylinder in Cross Flow P M V Subbarao Associate Professor Mechanical Engineering Department IIT Delhi A Common Industrial Application.
Kern Method of SHELL-AND-TUBE HEAT EXCHANGER Analysis
Heat transfer equipments:
Hydraulic Analysis of STHE Using Bell Delaware Method
Heat exchangers The device at which heat exchange between two fluids at different temperatures and separated by a solid wall occurs is called heat exchanger.
Thermo-economic Optimization of STHE P M V Subbarao Professor Mechanical Engineering Department I I T Delhi Minimizing capital and operating costs of shell.
ME421 Heat Exchanger and Steam Generator Design
Introduction to Heat Exchangers
THERMAL ANALYSIS OF SHELL AND TUBE HEAT EXCHANGER
Shell and Tube Heat Exchangers
Supervised by : Dr. mohammad fahim Eng. Yousef ali Yaqoub bader ali.
HEAT EXCHANGER By Farhan Ahmad Department of Chemical Engineering,
ME421 Heat Exchanger and Steam Generator Design Lecture Notes 6 Double-Pipe Heat Exchangers.
Shell and Tube Heat Exchangers. Goals: By the end of today’s lecture, you should be able to:  describe the common shell-and-tube HE designs  draw temperature.
Heat Exchanger Design Anand V P Gurumoorthy Associate Professor
Heat Exchanger & Classification Prepared by: Nimesh Gajjar
INTRODUCTION Definition:
Capture and Utilization of Carbon Dioxide Ethanol Production Presented By: Dana Al-Maiyas. Supervised By: Prof.Mohamad A.Fahim. Eng.Yousif Ismael.
ME 414 : Project 1 Heating System for NASA North Pole Project Team Members Alan Benedict Jeffrey Jones Laura O’Hair Aaron Randall May 5, 2006.
Heat Exchangers This is session 19 in curriculum manual.
Heat Transfer Equations For “thin walled” tubes, A i = A o.
SHELL AND TUBE HEAT EXCHANGER
Design Formulae for Mingled Shell-side stream P M V Subbarao Professor Mechanical Engineering Department I I T Delhi Corrections for Non-Ideal (Cross.
Large Shell Heat Exchangers P M V Subbarao Professor Mechanical Engineering Department I I T Delhi An Engineering Solution to the Crisis of Massive Volume.
The Family of Shell and Tube Heat Exchangers P M V Subbarao Professor Mechanical Engineering Department I I T Delhi Family members with Simple Geometrical.
Heat Exchangers Heat exchangers are used to transfer heat from one stream to another. They are used to heat streams and to cool streams. The streams can.
Team Yellow. Experiment 3 IRI Economics FCI and Annual Costs FCI is $4.63 million Annual product cost is $104 million Annual cash flow is -$77 million.
Chapter 11 Heat Exchangers ( ) Heat Exchangers.
Equipment Design Designed by Eman A. Khajah. Outline Design of Heater. Design of Stripper.
Table of content 1- Heat exchanger design (cooler ) 2- Distillation column design. 3- Valve.
Heat Transfer Equations For “thin walled” tubes, A i = A o.
FOOD ENGINEERING DESIGN AND ECONOMICS
Done by: Zainab Al-fadhli Supervised by: Prof: M.Fahim Eng : Yusuf Ismail Kuwait university Engineering and Petroleum college Chemical Engineering Department.
Table of Content Introduction of heat exchanger. Design of Coolers. Introduction of fixed bed reactors. Design of reactors.
ME444 ENGINEERING PIPING SYSTEM DESIGN CHAPTER 11: STEAM PIPING SYSTEM (1)
Heat Transfer by Convection
Government Engineering College HEAT EXCHANGER Mechanical Engineering Department Sub: Heat Transfer Sub Code: Presented by: RAVAL SACHIN.
TP - heat exchanger design.ppt 1 Transport Processes Overall heat transfer coefficient  From previous studies (CPP module): Q’=UAΔT LM Some typical U.
CHE 441 Lecture 6 Heat Exchanger Design. Heat Exchangers  Heat Transfer Basics  Tubular Exchangers  Heat Exchanger Design  Compact Heat Exchangers.
CHEMCAD Seminar Heat Transfer John Edwards, P&I Design Ltd
DESIGN OF SHELL AND TUBE HEAT EXCHANGER
Unit 42: Heat Transfer and Combustion
ERT 216 HEAT AND MASS TRANSFER
CONTENTS DESIGN PROBLEM INTRODUCTION FLOW CHART OF DESIGN
By: Brittany Watton & Jeff Philippart
WHAT IS HX……??? Heat exchangers are equipment that transfer
General Description Shell and Tube Heat Exchangers are one of the most popular types of exchanger due to the flexibility the designer has to.
Process Equipment Design and Heuristics – Heat Exchangers
Tubes Dimensions Tube diameters in the range 5/8 in. (16 mm) to 2 in. (50 mm) are used. The smaller diameters 5/8 to 1 in. (16 to 25 mm) are preferred.
Chapter 4 Heat Exchangers: Design Considerations
Chapter 18 ChEN 4253 Terry A. Ring
PLATE HEAT EXCHANGERS Gasketed plate heat exchangers
Heat Exchangers Heat Exchangers.
SHELL-AND-TUBE HEAT EXCHANGERS
Presentation transcript:

1 Shell-and-Tube Heat Exchangers Shell-and-Tube Heat Exchangers Choose of the right TEMA type and decide which stream goes in the tubes By:A.Behzadi

2 Lecture series Introduction to heat exchangers Selection of the best type for a given application Selection of right shell and tube Design of shell and tube

3 Contents Why shell-and-tube? Scope of shell-and-tube Construction TEMA standards Choice of TEMA type Fluid allocation Design problems Enhancement Improved designs

4 Why shell-and-tube? CEC survey: S&T accounted for 85% of new exchangers supplied to oil-refining, chemical, petrochemical and power companies in leading European countries. Why? Can be designed for almost any duty with a very wide range of temperatures and pressures Can be built in many materials Many suppliers Repair can be by non-specialists Design methods and mechanical codes have been established from many years of experience

5 Scope of shell-and-tube Maximum pressure – Shell 300 bar (4500 psia) – Tube 1400 bar (20000 psia) Temperature range – Maximum 600 o C (1100 o F) or even 650 o C – Minimum -100 o C (-150 o F) Fluids –Subject to materials –Available in a wide range of materials Size per unit ft 2 ( m 2 ) Can be extended with special designs/materials

6 Construction Bundle of tubes in large cylindrical shell Baffles used both to support the tubes and to direct into multiple cross flow Gaps or clearances must be left between the baffle and the shell and between the tubes and the baffle to enable assembly Shell Tubes Baffle

7 Shell-side flow

8 Tube layouts Typically, 1 in tubes on a 1.25 in pitch or 0.75 in tubes on a 1 in pitch Triangular layouts give more tubes in a given shell Square layouts give cleaning lanes with close pitch pitch Triangular 30 o Rotated triangula r 60 o Squar e 90 o Rotate d square 45 o

9 TEMA standards The design and construction is usually based on TEMA 8th Edition 1998 Supplements pressure vessel codes like ASME and BS 5500 Sets out constructional details, recommended tube sizes, allowable clearances, terminology etc. Provides basis for contracts Tends to be followed rigidly even when not strictly necessary Many users have their own additions to the standard which suppliers must follow

10 TEMA terminology Letters given for the front end, shell and rear end types Exchanger given three letter designation Above is AEL Shell Front end stationary head type Rear end head type

11 Front head type A-type is standard for dirty tube side B-type for clean tube side duties. Use if possible since cheap and simple. B Channel and removable cover Bonnet (integral cover) A

12 More front-end head types C-type with removable shell for hazardous tube- side fluids, heavy bundles or services that need frequent shell-side cleaning N-type for fixed for hazardous fluids on shell side D-type or welded to tube sheet bonnet for high pressure (over 150 bar) B N D

13 Shell type E-type shell should be used if possible but F shell gives pure counter-current flow with two tube passes (avoids very long exchangers) EF One-pass shell Two-pass shell Longitudinal baffle Note, longitudinal baffles are difficult to seal with the shell especially when reinserting the shell after maintenance

14 More shell types G and H shells normally only used for horizontal thermosyphon reboilers J and X shells if allowable pressure drop can not be achieved in an E shell J H G X Split flow Double split flow Divided flowCross flow Longitudinal baffles

15 Rear head type These fall into three general types fixed tube sheet (L, M, N) U-tube floating head (P, S, T, W) Use fixed tube sheet if  T below 50 o C, otherwise use other types to allow for differential thermal expansion You can use bellows in shell to allow for expansion but these are special items which have pressure limitations (max. 35 bar)

16 Fixed rear head types L is a mirror of the A front end head M is a mirror of the bonnet (B) front end N is the mirror of the N front end L Fixed tube sheet

17 Floating heads and U tube Allow bundle removal and mechanical cleaning on the shell side U tube is simple design but it is difficult to clean the tube side round the bend

18 Floating heads T S Pull through floating head Note large shell/bundle gap Similar to T but with smaller shell/ bundle gap Split backing ring

19 Other floating heads Not used often and then with small exchangers PW Outside packing to give smaller shell/bundle gap Externally sealed floating tube sheet maximum of 2 tube passes

20 Shell-to-bundle clearance (on diameter) Shell diameter, m Clearance, mm Fixed and U-tube P and S T

21 Example BES Bonnet front end, single shell pass and split backing ring floating head

22 What is this?

23 Allocation of fluids Put dirty stream on the tube side - easier to clean inside the tubes Put high pressure stream in the tubes to avoid thick, expensive shell When special materials required for one stream, put that one in the tubes to avoid expensive shell Cross flow gives higher coefficients than in plane tubes, hence put fluid with lowest coefficient on the shell side If no obvious benefit, try streams both ways and see which gives best design

24 Example 1 Debutaniser overhead condenser Hot sideCold side FluidLight hydrocarbonCooling water CorrosiveNoNo Pressure(bar) Temp. In/Out ( o C)46 / 4220 / 30 Vap. fract. In/Out1 / 00 / 0 Fouling res. (m 2 K/W)

25 Example 2 Crude tank outlet heater Cold sideHot side FluidCrude oilSteam CorrosiveNoNo Pressure(bar)2.010 Temp. In/Out ( o C)10 / / 180 Vap. fract. In/Out0 / 01 / 0 Fouling res. (m 2 K/W)

26 Rule of thumb on costing Price increases strongly with shell diameter/number of tubes because of shell thickness and tube/tube-sheet fixing Price increases little with tube length Hence, long thin exchangers are usually best Consider two exchangers with the same area: fixed tubesheet, 30 bar both side, carbon steel, area 6060 ft 2 (564 m 2 ), 3/4 in (19 mm) tubes LengthDiameterTubesCost 10ft60 in3139$112k (£70k) 60ft25 in523$54k (£34k)

27 Shell thickness p is the guage pressure in the shell t is the shell wall thickness  is the stress in the shell From a force balance pDsDs tt p tt hence

28 Typical maximum exchanger sizes Floating HeadFixed head & U tube Diameter60 in (1524 mm)80 in (2000 mm) Length30 ft (9 m) 40 ft (12 m) Area ft 2 (1270 m 2 ) ft 2 (4310 m 2 ) Note that, to remove bundle, you need to allow at least as much length as the length of the bundle

29 Fouling Fouling Shell and tubes can handle fouling but it can be reduced by keeping velocities sufficiently high to avoid deposits avoiding stagnant regions where dirt will collect avoiding hot spots where coking or scaling might occur avoiding cold spots where liquids might freeze or where corrosive products may condense for gases High fouling resistances are a self-fulfilling prophecy