IRC CHAPTER 11 AND HERS RESIDENTIAL ENERGY

Slides:



Advertisements
Similar presentations
BUILDING ENERGY CODES UNIVERSITYwww.energycodes.gov/BECU 1 BUILDING ENERGY CODES UNIVERSITY ANSI/ASHRAE/IES Standard Scope and Application April.
Advertisements

U.S. Department of Energy Building Energy Codes Program
Presents 2012 Revisions to the NC Energy Code For Residential Building started after March 1, 2012.
EarthCraft: Insulating Strategies Energy Efficient Insulation Systems by Church Hill Homes.
2009 IECC – Residential Energy code Training
eQuest Quick Energy Simulation Tool
“Do not take anyone’s advice as to how this building should be assembled.”
Heating, Ventilating, and Air-Conditioning (HVAC)
2009 Washington State Energy Code Residential Sections
Residential Provisions of the 2012 International Energy Conservation Code July 2011 PNNL-SA
Energy Square 1111 “O” Street, Suite 223 Lincoln, Nebraska Website: Phone:
PERMITS & INSPECTIONS DEPARTMENT 2003 INTERNATIONAL RESIDENTIAL CODE IRC.
2004 Florida Building Code, Mechanical/Energy Technical Core Summary (1 hour) June 2004.
Energy Rating Index Performance Path Speaker Name Speaker Affiliation.
West Virginia's residential building code is mandatory statewide; however, adoption by jurisdictions is voluntary. The 2013 West Virginia Legislature.
The House as a System 1. Air Temperature and Water Vapor.
Energy Rating Index Performance Path Speaker Name Speaker Affiliation.
Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010.
Village of Frankfort, Illinois April 21, 2010 The 2009 International Energy Conservation Code Overview.
Presented by: Energy Systems Laboratory (ESL) Texas A&M University Funded by: State Energy Conservation Office (SECO) US Department of Energy (DOE) The.
Residential Provisions of the 2015 International Energy Conservation Code PNNL-SA
Heat Loss & Gain Calculations 1. How Heat Moves in Homes Conduction is the transfer of heat through solid objects, such as the ceilings, walls, and floors.
This 12 part PowerPoint series is taken directly from Energy Savers Booklet, Tips on Saving Energy & Money at Home, U.S. Department of Energy.
The Energy Star Home Drew Tepper. Overview What is an energy star home? What is an energy star home? New Homes New Homes Existing Homes Existing Homes.
Chapter 2: Energy Ratings and Economics To be used with the Guide to Building Energy Efficient Homes in Kentucky.
ENERGY STAR Multifamily High Rise Program Testing and Verification Protocols Webinar – Part II August 2011.
Chapter 4: Air Leakage Control: Materials and Techniques
BUILDING ENERGY CODES UNIVERSITYwww.energycodes.gov/training 1 Building Energy Codes An Introduction Department of Energy Energy Efficiency & Renewable.
1 Foundation Moisture Control and Energy Performance.
Copyright 2008, International Code Council 2012 IECC ® for SERBCA Based on the 2012 International Energy Conservation Code.
Massachusetts “Stretch” Energy Code Marc Breslow Executive Office of Energy & Environmental Affairs.
Adriana Galue Wolfgang Custom Finishes HOME ENERGY STATS Biggest energy consumers Space heating – 34% Appliances and lighting – 34% Refrigerator.
The Fall Builders’ Forum Part 9 Energy Efficiency and Ventilation Regulations “Effective December 19 th, 2014”
MECHANICAL ASPECTS OF MICHIGAN UNIFORM ENERGY CODE MIAM DOHERTY INN CLAIRE, MICHIGAN MARK RILEY.
Arkansas Energy Code 2004 Compliance
1 Connecticut’s New Energy Code Connecticut ASHRAE Tech Session October 13, 2011 Frederick F. Wajcs, Jr. Senior Energy Engineer Connecticut Light and Power.
IECC, REScheck, and COMcheck Mark Halverson Pacific Northwest National Laboratory PNNL-SA
Residential New Construction Montana House: UES Measure Update Adam Hadley Regional Technical Forum April 14, 2015.
Brought to you by: Connecticut Energy Code Frederick F. Wajcs Senior Energy Engineer Northeast Utilities February 10, 2011.
ENERGY CONSERVATION BUILDING CODE – 2006 PRESENTATION BY VP GUPTA PRINCIPAL CHIEF ENGINEER (ELECTRICAL), BSNL CHENNAI.
SEEA Presentation to SEES March 2006 SEEA Presentation to SEES February 2006 SOUTHEAST ENERGY EFFICIENCY ALLIANCE.
Massachusetts New Homes with ENERGY STAR ® The sponsors of the Massachusetts New Homes with ENERGY STAR are Bay State Gas, Berkshire Gas, Cape Light Compact,
Residential Provisions
Demonstrating a Home Under Construction Purpose: To use your knowledge of the construction process and production USPs to influence the sales process and.
Part 2: Buildings as a System Lee F. Ball Jr., PhD
Residential Energy Code Compliance
North Carolina State Buildings Efficiency Conference
Residential Weatherization and Ventilation Subcommittee Presentation to the Regional Technical Forum August 30, 2011.
Insulation and Infiltration
Energy Conservation February 8, Steve Wilson, MBA, CEM, CDSM, BEP The Energy Guy.
BUILDING ENERGY CODES UNIVERSITYwww.energycodes.gov/training 1 BUILDING ENERGY CODES UNIVERSITY Residential Requirements of the 2009 International Energy.
Understanding Building Systems. Physical Layout Building Plans Architectural Plans Structural Plans Mechanical Plans Plumbing Plans Electrical Plans HVAC.
Helping Massachusetts Municipalities Create a Greener Energy Future Code Informational Session February 10, 2016.
Day 2 Part 2 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
Zone 4 R-38 Ceilings U-0.35 Windows, Doors R-13 Walls R-19 Floors R-10 Foundations.
NORTHWEST ENERGY EFFICIENCY ALLIANCE Affordable Performance Home Initial thoughts…… November 2011.
Stretch Code Informational Session March 16, 2011.
Day 4 Part 3 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
Day 4 Part 2 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
Stretch Code Informational Session February 16, 2011.
SMART ENERGY EFFICIENCY FOR SMART PEOPLE PHOTO CREDIT: S. STEWART DOE Solar Decathlon nd Place University of Illinois at Urbana- Champaign.
2015 International Energy Conservation Code
Energy Codes and the Building Envelope
Truss Heel Heights and Energy Code Requirements
Home Energy Savings Program Wyoming
2015 Energy Code: Major Changes for Residential Buildings
Energy Code Program Manager – SPEER
BUILDING Codes And Standards
Compliance Software Tool Approval Technical Assistance Manual
Energy Codes and the Building Envelope
Presentation transcript:

IRC CHAPTER 11 AND HERS RESIDENTIAL ENERGY Kelly Parker, P.E. Oklahoma Building Summit August 26, 2015

IRC Chapter 11 and HERS HERS: Home Energy Rating System

IRC Chapter 11 and HERS

RESNET The RESNET vision: “RESNET’s vision is of a world that encourages and rewards minimum building energy use through independent, performance-based building certification.”

RESNET The RESNET mission: “RESNET’s mission is to ensure the success of the building energy performance certification industry, set the standards of quality and increase the opportunity for ownership of high performance buildings.”

Who Recognizes RESNET’s Standards Builders (for the HERS Rating) Contractors (the emerging retrofit market) States and municipalities for code compliance Federal government agencies IRS: 2005 EPACT new housing tax credit Environmental Protection Agency (EPA): the ENERGY STAR for Homes program (Version 3) Department of Energy (DOE): Building America and National Builders Challenge programs

2009 International Residential Code Chapter 11

Approved software is used to develop a Index. REM/Rate Energy Gauge Others

IRC CHAPTER 11 AND HERS HERS inputs into REM/Rate: General building inputs (sf, vol, # of floors, bedrooms) Foundation wall properties Slab floor properties (sf, insulation, exposed perimeter) Floors over unconditioned space. Rim and band properties (sf, R-value) Above grade wall properties (sf, type) Windows and glass doors (sf, U-factor, SHGC, shading) Door properties Ceiling properties (sf, type, R-value)

Chapter 11 and HERS HERS inputs into REM/Rate: Mechanical equipment properties (Btuh, efficiency) Duct system summary (sf, R-value, location, leakage) Blower door test (leakage) Mechanical ventilation Appliances and lighting summary

IRC 2009 RESIDENTIAL ENERGY New Codes are here and adopted statewide July, 2011. The 2009 IRC addresses issues that have been building problems in the past. Several problem areas that have been around for years will now have solutions.

Oklahoma Uniform Building Code Commission www.ok.gov.oubcc/ Adopted Building Codes   Code Adopted Effective Date of Adoption Modifications to the code International Residential Code ®, 2009 Edition (IRC®, 2009) July 15, 2011 Click Here for modifications to the code adopted by reference Adopted Building Codes   Code Adopted Effective Date of Adoption Modifications to the code International Residential Code ®, 2009 Edition (IRC®, 2009) July 15, 2011 Click Here for modifications to the code adopted by reference

Chapter 11, Energy Efficiency N1101.1 Scope This chapter is for regulating the design and construction of buildings to improve the energy efficiency of those structures.

Chapter 11, Energy Efficiency N1101.2 Compliance Demonstrated by either meeting the requirements of this chapter or the 2009 International Energy Conservation Code. Requirements are climate specific according to Figures N1101.2 and Table N1101.2.

Chapter 11, Energy Efficiency N1101.2.1 and Table N1101.2 Climate Zones, Moisture Regimes, and Warm-Humid Designations (clarification) Places all the above info into one table. Provides county designations for clarity and usability. Warm humid counties are now indicated with an asterisk. All counties in Oklahoma are Climate Zone 3A except for Beaver, Cimarron, and Texas located in the panhandle which are 4B

Chapter 11, Energy Efficiency By accepting State Energy Program funding and submitting letters assuring the Department of Energy that their states would comply with the terms of Section 410, all 50 states have committed to do three things: Adopt a residential building energy code that meets or exceeds the 2009 International Energy Conservation Code (IECC);¹ Adopt a commercial building energy code that meets or exceeds the ANSI/American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE)/IESNA Standard 90.1-2007; and Develop and implement a plan, including active training and enforcement provisions, to achieve 90 percent compliance with the target codes by 2017, including measuring current compliance each year. ¹ U.S. DOE has determined that the 2009 International Residential Code (IRC) does not meet the energy provisions of the 2009 International Energy Conservation Code (IECC).

Chapter 11, Energy Efficiency N1101.3 Identification The code is to identify materials, systems and equipment that allow for the determination of compliance to meet the energy efficiency requirements of this chapter.

Chapter 11, Energy Efficiency   Pursuant to ARRA requirements and to obtain Oklahoma’s $46,704,000 million portion of the SEP, and following Governor Henry’s letter of commitment to Secretary Chu on February 20, 2009, Oklahoma enacted a law on June 2, 2009, creating the Oklahoma Uniform Building Code Commission (UBCC). This enactment was Oklahoma’s first step towards meeting one priority of SEP, which is the “establishment of enforcement of energy efficient building codes and standards, and implementation of voluntary programs that impact new design”. Oklahoma Uniform Building Code Commission Act, 59 O.S. §§ 1000.20 et seq. (2009). Oklahoma Department of Commerce www.okcommerce.gov

Chapter 11, Energy Efficiency All counties are in zone 3A Except Beaver, Cimarron, and Texas, which are in zone 4B.   Pursuant to ARRA requirements and to obtain Oklahoma’s $46,704,000 million portion of the SEP, and following Governor Henry’s letter of commitment to Secretary Chu on February 20, 2009, Oklahoma enacted a law on June 2, 2009, creating the Oklahoma Uniform Building Code Commission (UBCC). This enactment was Oklahoma’s first step towards meeting one priority of SEP, which is the “establishment of enforcement of energy efficient building codes and standards, and implementation of voluntary programs that impact new design”. Oklahoma Uniform Building Code Commission Act, 59 O.S. §§ 1000.20 et seq. (2009). Oklahoma Department of Commerce www.okcommerce.gov

Chapter 11, Energy Efficiency N1101.4 Building Thermal Envelope Insulation All installed insulation ≥12” must have the R-value marked or a certificate must be provided. For sprayed or blown insulation (fiberglass or cellulose), a certificate must list: Initial installed thickness Settled thickness Settled R-value Installed density Coverage area Number of bags installed

Chapter 11, Energy Efficiency N1101.4 Building Thermal Envelope Insulation (continued) For sprayed polyurethane foam: Installed thickness R-value of installation Sticker shall be signed, dated and posted in a “conspicuous location on the job site.”

Chapter 11, Energy Efficiency N1101.4 Blown or Sprayed Roof/Ceiling Insulation Markers installed 1 for every 300sf with numbers at least 1” tall to help determine the depth of the installed insulation. Stickers must face the attic access opening.

Chapter 11, Energy Efficiency N1101.5 Fenestration Product Rating For U-factors (windows, doors and skylights) and solar heat gain coefficient (SHGC) (glazed fenestration) must have a label on each product or assigned a default value from Tables N1101.5(1)-N1101.5(3). Must be accredited by an independent lab and labeled and certified by the manufacturer.

Chapter 11, Energy Efficiency N1101.8 Above Code Programs National, state, or local energy efficiency programs may be used, at the building official or other jurisdiction’s discretion as conforming to the energy code. REM/Rate and HERS Index REScheck

Chapter 11, Energy Efficiency N1101.9 Permanent Energy Certificate (modification) Certificate shall not cover or obstruct required labels on an electrical distribution panel. (Sticker not required in Oklahoma) An efficiency shall not be listed for gas-fired unvented room heaters, electric furnaces, or electric baseboard heaters.

Chapter 11, Energy Efficiency Coming to ALL Houses Example

Chapter 11, Energy Efficiency N1102.1 Insulation and Fenestration Criteria The building envelope shall meet the requirements found in Table N1102.1 according to climate zones found in Table N1101.2.

Chapter 11, Energy Efficiency

Chapter 11, Energy Efficiency N1102.1.1 R-value Computation Shall be the sum of the wall insulation R-value plus the exterior sheathing. No other components are included. The settled R-value shall be used for blown insulation.

Chapter 11, Energy Efficiency N1102.1.2 U-factor Alternative U-factor from Table N1102.1.2 shall be allowed instead of the R-values from Table N1102.1. Comment: U-factor is the inverse of the R-value. Ceiling U-factor of 0.033 is equal to an R-value of 30. U=1/R

Chapter 11, Energy Efficiency N1102.1.3 Total UA Alternative “If the total building thermal envelope UA (sum of the U-factor times assembly area) is less than or equal to the total UA resulting from using the U-factors in Table N1102.1.2, (multiplied by the same assembly area as in the proposed building), the building shall be considered in compliance with Table N1102.1.”

Chapter 11, Energy Efficiency N1102.2.1 Ceilings with Attic Spaces Section requires increased R-values over the exterior wall top plates: R-30 where R-38 is called for in attic. R-38 where R-49 is called for in attic. Does not address R-30 insulation requirement. The stated insulation must be uncompressed. Comment: An R-30 batt in a 6” cavity is approximately equal to an R-21.

Chapter 11, Energy Efficiency N1102.2.2 Ceilings without Attic Spaces Where >R-30 is required for a ceiling but space does not allow for it, R-30 shall be allowed for up to 500sf.

Chapter 11, Energy Efficiency N1102.2 Ceiling and Access Hatch Insulation Requirements (clarification) Access doors to unconditioned space will be weatherstripped and insulated to same R-value as the ceiling. Insulation baffle installed at edges to prevent spilling into the living space and maintain the installed R-value.

Chapter 11, Energy Efficiency Table N1102.2.5 Steel Framed Wall Insulation (modification) Contains an option for steel framed wall without cavity insulation for Zones 1 thru 4. Apply continuous insulation R-10 to outside (equivalent of wood frame R-13).

Chapter 11, Energy Efficiency N1102.2.6 Floors Floor insulation must be placed in permanent contact with the subfloor. Comment: Staples are not permanent; gravity eventually wins. Requires tension wires or equivalent.

Chapter 11, Energy Efficiency N1102.2.7 Basement Walls Basement walls for conditioned space shall be insulated from the grade plane to either 10 feet below or to the basement floor, whichever is less. For climate zone 3, requires either an R-5 on the exterior or R-13 on the interior. No wall insulation required if the floor above the basement is insulated.

Chapter 11, Energy Efficiency N1102.2.8 Slab-on-grade Floors No insulation required for Climate Zone 3. Comment: Slab insulation can be used for the Federal Tax Credit, which expired December 31. We are hoping it will be renewed. Comment: Some builders are achieving a HERS Index of 70 (30% more efficient than a house built to the 2004 IECC) and less to obtain the state tax credit.

Chapter 11, Energy Efficiency N1102.2.9 Crawl Space Walls Nothing required if floor is insulated and crawl is vented. If unvented, crawl space wall insulation must be permanently attached from the floor to the finished Grade level and then vertically and/or horizontally an additional 24 inches. Exposed earth shall be covered with a Class I vapor retarder, overlapped 6” and joints sealed or taped and attached to the stem wall at a height of at least 6”.

Chapter 11, Energy Efficiency N1102.2.11 Thermal Isolated Sunroom Insulation Ceiling insulation shall be R-19 for Climate Zones 1-4 and R-24 for Zones 5-8. Wall insulation shall be at least an R-13. New walls to meet current construction code requirements.

Chapter 11, Energy Efficiency N1102.3.3 Glazed Fenestration Exemption U-factor and SHGC requirements can be waived for up to 15sf of glass. N1102.3.4 Opaque Door Exemption For one opaque door up to 24sf can be exempted from the U-factor requirements.

Chapter 11, Energy Efficiency N1102.3.6 Replacement Fenestration Shall meet the requirements for U-factor and SHGC from Table N1102.1.

Chapter 11, Energy Efficiency N1102.4.1 Sealing of the Building Thermal Envelope (clarification) Joints, seams and penetrations Site-built windows, doors, and skylights Openings between windows/doors and framing or jambs Utility penetrations Dropped ceilings or chases Kneewalls Walls and ceilings separating garage from conditioned space Behind tubs and showers on exterior walls Common walls between units Attic access openings Rim joist junction Other sources of infiltration

Chapter 11, Energy Efficiency Envelope leakage testing option to 7 ACH at 50 Pa. Seven requirements for testing. N1102.4.2.2 Visual inspection option allowed by code official by third party independent from the insulation contractor following list in N1102.4.1.

Chapter 11, Energy Efficiency N1102.4.5 Recessed Lighting (modification) Shall be IC rated. Shall be labeled as meeting ASTM E 283 for air leakage. Shall be sealed with caulk or a gasket between the housing and interior wall. New term: ICAT, Insulation Contact Air Tight

Chapter 11, Energy Efficiency N1103.1.1 Programmable Thermostat Each dwelling unit shall have one thermostat capable of maintaining a daily schedule to maintain different temperature set points. Must be able to achieve temperatures from 55° to 85°. Not required in Oklahoma at this time. Update: July, 2015 new IRC??

Chapter 11, Energy Efficiency N1103.1.2 Heat Pump Supplementary Heat When supplementary electric resistance heat, must have controls preventing supplemental heat operation when the unit is capable of meeting the heating load. Emergency Heating

Chapter 11, Energy Efficiency N1103.2.1 Duct Insulation Ducts in unconditioned space shall be R-8. All others shall be R-6. Oklahoma Tax Credit: Supply and return ducts shall be insulated to a minimum of R-8

Chapter 11, Energy Efficiency N1103.2.2 Duct Sealing (addition) Duct tightness shall be verified by either Post construction test, leakage to outside at 8 cfm per 100 sf or total leakage test at 12 cfm per 100 sf, both at 25 Pa. Rough-in test, total leakage at 6 cfm per 100 sf tested at 25 Pa. (Visual inspection may be used instead of the rough-in test and post construction test in Oklahoma.)

Chapter 11, Energy Efficiency N1103.2.3 Building Cavities Building framing cavities shall not be used as supply ducts N1103.3 Mechanical System Piping Insulation All mechanical system piping carrying fluids above 105°F or below 55°F must be insulated to at least an R-3.

Chapter 11, Energy Efficiency N1103.4 Circulating Hot Water Systems All lines shall be insulated to at least an R-2. In addition, there must be a readily accessible manual switch for disengaging the system when not being used.

Chapter 11, Energy Efficiency N1103.6 Equipment Sizing “Heating and cooling equipment shall be sized as specified in Section M1401.3.” All buildings must have load calculations performed. M1401.3 Sizing HVAC system sized according to ACCA Manual S based on load calculations from ACCA Manual J (Version 8 is the latest version) Comment: ACCA Manual S - Residential Heating and Cooling Equipment Selection Comment: ACCA Manual J8 – Residential Load Calculation

Chapter 11, Energy Efficiency N1103.8.1 Pool Heaters All pool heaters shall have a readily accessible on/off switch for turning the equipment off without adjusting the thermostat. No continuous burning pilot lights allowed.

Chapter 11, Energy Efficiency N1103.8.2 Time Switches Heaters and pumps must have time switches installed that can automatically control use of those components.

Chapter 11, Energy Efficiency N1103.8.3 Pool Covers Heated pools shall have a vapor retardant pool cover on or at the water surface. Comment: removed from the code for Oklahoma. Pools heated above 90°F must have a cover with an R-value of at least 12. Comment: remains in the Oklahoma code.

Chapter 11, Energy Efficiency N1104 Lighting Systems (addition) 50% of permanently installed lighting fixtures required to be CFLs or other high-efficacy lamps. Comment: Can or recessed lighting are exempt in Oklahoma. Update, 2015 IRC??

Kelly Parker, P.E. kellypar@gwssi.com 405-946-0206 Thank You for Your Time Kelly Parker, P.E. kellypar@gwssi.com 405-946-0206