STYLITIS-POWER …designed for in‐coming and out‐coming power/energy analysis.

Slides:



Advertisements
Similar presentations
Yokogawa Network Solutions Presents:
Advertisements

Welcome to the Radionet Monitoring Secure-Com Presentation.
Installation base of over 25,000 valued installations, Country wide Installation base of over 25,000 valued installations, Country wide Recognised as.
Troubleshooting Training Course.  Visual and General Test  Perform System Test (Mode  Perform System Test)  Identify The Error  If you need Technical.
1 Rev /02 Modular Construction Dual/Redundant CPU/Power Supply Support TCP/IP Communication Protocol 4096 Camera by 512 Monitor Switching English.
1 Rev /02 Modular Construction Dual/Redundant CPU/Power Supply Support TCP/IP Communication Protocol 4096 Camera by 512 Monitor Switching English.
8 April Doors Network Configuration Parameters (Single Site Mode)
DSL-2870B How to Change ADSL Username and Password in your modem router How to Change Wireless Channel in your modem router How to Open Ports in your modem.
KX-NS1000 Initial Set Up For step by step : 16 May,
Nada Abdulla Ahmed.  SmoothWall Express is an open source firewall distribution based on the GNU/Linux operating system. Designed for ease of use, SmoothWall.
MCS-TOUCHSCREENS MCS-TOUCH-7 FRONT BACK  NEW FOR 2015  High Resolution (1280 x 800)  LCD Display with LED Backlighting.
CheckMeter 2.3 Portable Working Standard Page 1 March 2009.
Cambodia-India Entrepreneurship Development Centre - : :.... :-:-
6 February LAN-50/500 Ethernet Communication.
Monitoring systems COMET types MS55 & MS6 MS55/MS6 Configuration.
© 2010 McQuay International 1 McQuay Delivered VAV System Product Overview October 2010.
STYLITIS-10 …offers high performance data acquisition and control in a competitive price.
DEMONSTRATION FOR SIGMA DATA ACQUISITION MODULES Tempatron Ltd Data Measurements Division Darwin Close Reading RG2 0TB UK T : +44 (0) F :
STYLITIS-101 Advanced, portable data acquisition system covering a wide range of measurement and recording needs.
TAX-AIDE Network Router Setup Network Printer Setups July SMT/TCS Training - Dallas1.
Networking All talk - Selective listen Network up to 15 active nodes + 17 passive nodes Nexus/Discovery panels, network repeaters, R3 19” racks, Alarm.
Energy Management System Future Group. How Energy Management System helps  Gives Electrical parameters and energy consumption Section or store wise for.
G4 Control and Management Solution for Data- Centers and Computer Rooms.
DWR-113 FAQ’s 3G WiFi Router.
TrendReader Standard 2 This generation of TrendReader Standard software utilizes the more familiar Windows format (“tree”) views of functions and file.
Uniflair pCOWeb Ethernet interface card.
STYLITIS-10 …offers high performance data acquisition and control in a competitive price.
University of Bergen public domain software: SEISLOG Linux, data-acquisition system for standard PC and embedded lowcost, low-power solutions Terje Utheim.
RemoteDrive. OVERVIEW OVERVIEW The RemoteDrive is a special software running on Windows TM and controlling the devices manufactured by Elettronica Santerno.
Configuring the MagicInfo Pro Display
GML-3 GPRS BASED METER AND LOGGER THREE PHASE METER WITH INBUILT DATA LOGGER © Embuilt Technologies Visit us at Or For.
Module 13: Configuring Availability of Network Resources and Content.
NV V5.7 Product Presentation. Brand New Professional GUI  Multiple User Interface for different look and feel  Audio indicator on camera (play audio.
Introduction to Windows XP Professional Chapter 2 powered by dj.
Viola Systems M2M solution installation
Portable Working Standard and Power Quality Analyzer
Practical PC, 7th Edition Chapter 2: Working with Windows
1. SERIAL CONNECTION TO A PC Direct connection to the PC via a serial cable. Suitable for dataloggers with a serial RS-232 port. Communication via a serial.
1 Chapter Overview Using the New Connection Wizard to configure network and Internet connections Using the New Connection Wizard to configure outbound.
All rights reserved, property and © CAD Computer GmbH & Co.KG 2009 Cover page.
STYLITIS-41 … is suitable for measurements in Meteorological, Wind/Hydro potential and other Environmental fields.
Gauge Operation and Software by Scott A. Ager. Computer Recommendations 750 MHz Pentium III 64 Meg SRAM 40 Gig Hard Drive 1024 x 768 graphics CD Writer.
EMerge Browser Managed Security Platform Module 3: Startup eMerge Certification Course  Physical connection  TCP/IP Characteristics of PC  Initial connection.
Otasuke GP-EX! Chapter 11 GP-Viewer EX
All rights reserved, property and © CAD Computer GmbH & Co.KG 2009 Cover page.
Opton 4 short presentation1 Opton 4 User friendly operating software for Symmetron’s Stylitis data loggers.
STYLITIS-50 Most advanced datalogger for wind energy assessment.
DIGITAL RECORDING SYSTEM Installation Setup Wizard About Our Software.
STYLITIS-50 Most advanced datalogger for wind energy assessment.
1 Weblite Product Introduction. 2 Control Equipment via the Internet 8 Universal Inputs 8 Universal Outputs software selectable as analog or digital signals.
Power Probe The PSP Power Probe is a three phase data logger, quality of supply monitor, and remote terminal unit for demand-side- management. Historical.
DATA, SITE AND RESOURCE MANAGEMENT SOFTWARE. A Windows application software designed for use with Stylitis data loggers. EMMETRON consolidates resources,
STYLITIS-41 … is suitable for measurements in Meteorological, Wind/Hydro potential and other Environmental fields.
GPRS functionality overview in Horner OCS. GPRS functionality – Peer to Peer communication over GPRS – CSCAPE connectivity over GPRS – Data exchange using.
New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI) Autoflame Training 2014.
CheckMeter 2.1 Portable Working Standard Page 1 March 2009.
PAYware Transact Terminal Interface Manager
1 Chapter Overview Modems The Internet and Web Browsers.
11111 Apollo Internet Monitoring Tutorial Apollo Solar, Inc. 23 F. J. Clarke Circle Bethel, CT (203)
Run the on your PC to start the firmware configuration process Run IP Config Tool.
11 DEPLOYING AN UPDATE MANAGEMENT INFRASTRUCTURE Chapter 6.
Architectural Description The Wind application is based on the JDDAC platform. The system is comprised of a network of weather stations responsible.
DIGITAL MULTIMETER DMG
CMV-NET Chigo VRF Network Centralized Control System
Monitoring systems COMET types MS55 & MS6
Model /21 Clamp on Power HiTESTER
Cover page.
MCS-Connect Change all frames to windows
Administration Training
Presentation transcript:

STYLITIS-POWER …designed for in‐coming and out‐coming power/energy analysis

1. MAIN FEATURES Measurement inputs: -4 differential voltage inputs. (or 1 3-phase line+ neutral). Voltage input range: 0~280VAC -40 differential voltage inputs for connection to voltage‐output current transformers (CT) (or phase lines + neutral). Current input range is software configurable to cater for various CTs: 0,29 to 1,45 full scale VRMS for 0 to 6000A. Measurements: Voltage, Frequency, Current, Power Factor, Active, Reactive and Apparent Power and Energy All inputs sampled simultaneously at 2 kHz sample rate. True RMS value calculation based on full cycles within a 0.5 second interval. Averaging Interval selectable from 0.5 second to 1 hour in steps of 0.5 seconds. Recording in internal 4MB Flash memory. 1 serial communication port (DTE). Built-in Ethernet module. Optional: Built-in GSM/GPRS modem. Power supply may come from first voltage phase connection or separate socket.

2. PHYSICAL FORM Stylitis-Power features: Control -Touch-screen LCD graphic display, brief operation -Total control via our Opton software Com Ports: 1 serial communication port (DTE) INPUT CONNECTORS: Removable screw terminal strips on front panel ENCLOSURE: ΙΡ67 sealed with carrying handle. DIMENSIONS: 27 x 24.6 x 17,4 cm, WEIGHT: 3kg CONNECTORS: Removable circular connectors on left and right side

3. SCREEN AND KEYBOARD Stylitis-Power has an LCD touch screen graphic display. Most operations are performed via Opton, its free operating software. However, via the screen, you can: View instantaneous channel values. View logger time and recording interval. Display instant channel values (voltage, current, power and power factor) for all channels in tabular or bar graph form. Change the acquisition status (ON/OFF). Activate or deactivate the internal modem if there is one (activate either the modem or the serial port). View the internal modem’s signal strength (if there is one, and if it is in GSM data mode). To display instruction pages and general information about the instrument.

4. CHANNELS/MEASUREMENTS AND CT TYPES Input channels (measurements) supported: -Voltage (0~280VRMS): 4 channels or 1 3-phase one. -Frequency of the first Voltage channel. -Current, via Current Transformers: 40 channels or 10 3-phase ones. To save CTs, you can select for the neutral phase’s current to be computed, or, if you do not use neutral, for the third phase’s current to be computed. -Calculated for each current channel: -Power factor. -Active, Reactive and Apparent Power. -Active, Reactive and Apparent Energy, during each recording interval. The types of Current Transformers (Voltage Output ones) supported are: -0~1.000 VRMS output -0~0.500 VRMS output -0~0.333 VRMS output -1 mV/A output (1 VRMS max)

5. STYLITIS-POWER MODELS (VERSIONS) The datalogger is available either as standard model (with built-in Ethernet and RS-232 DTE port) or with an additional built-in modem. Therefore, its versions are: Standard Stylitis-Power. The logger features a built-in Ethernet port and an RS-232 DTE port. Stylitis-Power+GSM. The logger features an additional built-in GSM/GPRS modem. Each Stylitis-Power version is suitable for specific communication methods. These methods are presented in the next chapters.

6. COMMUNICATION METHODS Communicate with the datalogger via Opton, its operating software, in various ways, according to the model used: A.Standard Stylitis-Power 1.Locally 2.Via Ethernet (local network or a static IP internet connection) 3.Via a dynamic IP internet connection (via Symmetron’s Diameson Server) B. Stylitis-Power+GSM 1.Via a GSM data call. 2.Via GPRS, using a cheap Dynamic IP SIM Card (via Symmetron’s Diameson Server)

7. LOCAL COMMUNICATION 1. Locally RS-232 Connect via a null modem serial cable your computer COM port to the logger’s RS-232 DTE port. Stylitis-Power

8. STATIC IP ETHERNET COMMUNICATION 2. Via Ethernet (local network or a static IP internet connection) Connect the datalogger to a LAN or to the internet An ADSL connection (a static IP) for the logger is required only to connect the logger to the internet. LAN/ internet ADSL Router Stylitis-Power

9. DYNAMIC IP ETHERNET COMMUNICATION 3. Via a dynamic IP internet connection (via Symmetron’s Diameson Server) Connect the datalogger to the internet. By using Diameson Gateway, Symmetron’s server software, you do not need a static IP ADSL connection. Internet Dynamic IP ADSL Router Diameson Gateway Stylitis-Power

10. GSM COMMUNICATION 4. Via a GSM data call RS-232 Connect a GSM modem to a computer COM port. Call the logger’s modem, provided that both modems’ SIM cards support GSM data calls. GSM modem Stylitis-Power+GSM

11. GPRS COMMUNICATION (VIA DYNAMIC IP SIM) 5. Via GPRS, using a cheap Dynamic IP SIM Card (via Symmetron’s Diameson Server) Virtual COM Neither ADSL (static IP) connection is required for the logger nor expensive static IP SIM cards. A cheap dynamic IP GPRS SIM card is required. Low operation cost: The datalogger is permanently online, but only data exchange is charged. Devices (Dataloggers and Sym-o-nets) and Computers are connected as clients to Diameson Gateway, Symmetron’s server software. Symmetron’s Diameson is available for connections, but you can use your own Diameson, to manage your own dataloggers. Internet Diameson Gateway Stylitis-Power+GSM

Opton is Stylitis-Power’s free operating software. Start up with Opton, by creating Site folders and Connections. -Create one unique site folder for each datalogger. -In each site folder, multiple (different types of) connections can be created for the logger. The different connection types correspond to the communication methods, discussed before. -The connections created are saved as windows files, which are recognized by Opton in a folder interface, along with the compressed and decompressed data files (see Chapter 14), and setup files, ie logger settings (see next Chapter) saved in a file. Refer to the corresponding screen shot in Chapter 16. After achieving a connection, you can communicate with the logger. Besides changing its settings and download data, you can view some features, and specifically: -View the logger’s status: Instant parameters, such as the date and time, the current data file being recorded, the recording time remaining, etc. Refer to the corresponding screen shot in Chapter 16. -View the instant channel values. Refer to the corresponding screen shot in Chapter 16. -View an Online plot of the selected channels’ values. Samples are plotted every second. Besides the channel, you can also select the measurement (current, power factor, active energy, etc). Refer to the corresponding screen shot in Chapter OPTON: STARTING UP AND VIEW

13. OPTON: SETUP Connect to the datalogger, via Opton, via one of the connections you created and modify its setup. The main settings to be adjusted are the channel settings. VOLTAGE CHANNEL SETTINGS The Voltage Channel refers either to one 3-phase line (+neutral) or to 4 independent 1-phase lines. The only parameter to be set is each line’s slope. There is a default one, but you can also type a more exact calibrated one. CURRENT CHANNEL SETTINGS The Current Channels refer either to 10 3-phase lines (+neutral) or to 40 independent 1-phase lines. The settings of a current channels can be changed in two ways: -Change each phase’s Slope manually. There are default Slopes, but you can also type a more exact calibrated one. -Select a specific Current Transformer Type, along with its full scale current. This way, the Slopes will be calculated automatically. The CT types (correspond to their full scale output voltage) are: 1.000VRMS, 0.500VRMS, 0.333VRMS, 1mV/A RMS (1VRMS max). In 3-phase measurements, you can also save CTs, by selecting for the neutral current to be computed, or if you do not use neutral, by selecting for the 3 rd phase current to be computed. Refer to the corresponding screen shots in Chapter 16. REMAINING SETTINGS Other settings to be adjusted are: – The averaging recording interval (selectable from 0.5 sec to 1 hour). – The logger’s site name. – The GPRS settings of Symmetron’s Diameson server (IP and remote port). – Only for the GSM version: the GPRS settings of the SIM card (APN, User Name, Password).

After writing the desired setup in the datalogger, enable/ disable data acquisition to create data files, stored in the 4MB memory. When enabling acquisition, a new file begins. Files are stored in the logger’s memory in compressed form. When downloaded, a compressed file is decompressed into two data files: – One file containing each current channel’s energy (Active, Reactive and Apparent) within the interval. The sum of a column results in the corresponding energy of the entire file. – One file containing all the remaining measurements: Voltage, Frequency, Current, Power Factor, Active, Reactive and Apparent Power. The data files can be viewed via a text editor. Data are displayed either in plain text form or in grid form (channel columns are apparent). Compressed and decompressed data files are stored in the logger’s site folder, as mentioned in Chapter 12. Data download can be achieved either manually or automatically via AutoConnect software (see Chapter 18). MANUAL DOWNLOAD There are 2 types of manual download: Download the most recent file. If Acquisition is ON, this is the current file. In this case, the current file is firstly closed (the next file begins) and then downloaded. Download one or more consecutive previous files, by typing their number. 14. OPTON: ACQUISITION AND DOWNLOAD

After downloading the data files in the site folder, you can manage them offline. Opton offers some useful tools for offline management and presentation: Plot. View the selected channels’ plot, in up to 3 graph groups. Also, select specific measurements (current, power factor, etc) for each channel. View values at a specific moment with the channel units. Refer to the corresponding screen shot in Chapter 17. Data File Processing. Check the integrity of a folder’s files, ie check for missing or duplicate records or if the interval is the same for all files. Statistics. Statistics of the file’s data can appear per hour, per day, per month and per year. Statistics include be the average values of the data (within the hour, day, month or year), the max, min or sdv values, or sum of all values. The sum of an energy channel results in the total energy of the entire file. Statistics are presented via a bar graph or a dot plot. Refer to the corresponding screen shot in Chapter 17. Export to Excel/.CSV/.TAB file. Export a file’s data to an Excel, a comma delimited or a tab delimited file. 15. OPTON: OFFLINE DATA MANAGEMENT

16. OPTON: SCREEN SHOTS (PART 1) Site folders and files interface Instant data display Channel Setup Data Logger Status

17. OPTON: SCREEN SHOTS (PART 2) Online plot Data file plot Data file statistics

18. AUTOCONNECT SOFTWARE As stated before, data files can be downloaded manually, via Opton, via any connection. However, data download, along with other actions as well, can be preformed automatically, in a regular basis, via the additional free software AutoConnect. The datalogger can perform a different action each weekday: -Download Data: All data files missing from the folder. -Download Status: Instant parameters, such as the current file, the recording time remaining, etc. -Download Current Values. Get the instant channel values. The selected action of a weekday can be performed once a day at a specific selected time, or infinite connections can be made that weekday every as many minutes as you wish. Besides editing the auto connections (like in Opton) via AutoConnect’s interface, you can: -View a list of all your automatic connections and execute one or more manually. -Check each connection’s latest status, ie if it succeeded, or failed and why. -View the date and time of last connection and last successful download for each one.

19. MAIN APPLICATIONS AND CONCLUSION Stylitis-Power could be used in: Electric bill cost management in hotels, factories, etc professional spaces. Isolate your consumptions and detect your intensive loads. Green building certification. Machine operation scheduling in factory. Monitoring of substations network. …and many more Summing up, its main advantages are: Energy/ power analysis of 40 independent lines or 10 3-phase ones. CTs are the only additional accessories needed. Save CTs by selecting the neutral’s or the 3 rd phase’s current to be computed. Variety of communication methods. Standard Ethernet port included for remote communication and installation to your LAN. Free operating and automatic connection software. Portability.

about Symmetron Our company was founded in 1989 by experienced engineers and evolved as a major manufacturer of dataloggers and supplier of measurement equipment. Symmetron is certified according to the ISO9001 quality system and we are proud to have deployed thousands of measurement systems worldwide. Address 1, Antikythiron Street Gerakas Greece tel: fax: