Wireless Remote Controller (MR-AH01/BH01) HQ SE.  On/Off control  Air flow control  Temperature setting  Filter reset  Louver Control  Simple ON/OFF.

Slides:



Advertisements
Similar presentations
EACO News Magazine 2010 September : Topics DVM Plus III up compatibility New control devices –MIM-B16 –MIM-B17 –MIM-B18 How to change option code.
Advertisements

Page 1 Updated by: Yap Boon Thiam Technical Engineer Date: 09/5/2012.
Operating Functions.
JED Microprocessors Pty Ltd Presenting the JED T430 low-cost Projector Controllers Nov 22nd, 2009.
PC CMD V2 Enhancement and New Firmware
WebStat™ Programming and Configuration of Thermostats.
WIRED TYPE MULTI ZONE FANCOIL CONTROL SYSTEM MODEL : WSF- 700 SYSTEM
IR Control Materials taken from a variety of sources including IR Remote for the Boe-Bot by Andy Lindsay.
= ( es ) 2 energy savings. 53% SAVINGS* THAN OTHER LEADING INVERTERS! Best Energy Savings! High 11+ EER CASSETTE INVERTER FLOOR STANDING INVERTER HIGH.
① The output signal of a room thermostat is ON or OFF according to changes of room temperature ② The power supply to a motorized valve is ON or OFF according.
In this presentation you will:
EVOLUTION® Hands-On Demo This guide is meant to help lead a hands-on demo or presentation. The items listed are a suggestion for things to review, please.
PVD100 ‘Point Velocity Display’ Kota Samarahan Kuching, Sarawak July 2008.
1 Lab Equipment. 2 TopicSlides DC Power Supply3-4 Digital Multimeter5-8 Function Generator9-12 Scope – basic controls13-20 Scope – cursors21-24 Scope.
Cooling Only 38MFC/ 40MFC Heat Pump 38MFQ/ 40MFQ
Make your premises an Oasis of security Oasis_EN_1010_c1.
DWR-113 FAQ’s 3G WiFi Router.
Introduction ► Scope:- Service Diagnostics Routines can use for XXL, Side by Side products with STEALTH user interface with single evaporator fan product.
Ch. 5 – Access Points. Overview Access Point Connection.
Wall / V 12 V 12 Introduction Arguments Technical details Installation.
Solution Feb Samsung Electronics.
MDS Smart Commander.
On/Off Temp Holiday Select Fan Air clean Operation Auto SwingRoom Temp Week Select SET/CLR Hour MIN Timer Program Set Fan Speed Jet Cool Cancel RESET E_Heater.
I Pag 1 Microchiller 2. I Pag 2 I Pag 3 Information on the display.
ResourcePoint™ Data Entry Workflow. What is the ResourcePoint Module? The ResourcePoint module is a provider database that contains “operational” provider.
1 Active Floor. 2 General information 3 Active floor layout Main points: EC fan Blades Grilles.
MDS COMMISSIONING.
Connecting and Configuring Clickers. InterWrite PRS - Clicker 2-line LCD Display See data entered Confirmation answer received Variety of question types.
MDS Monitoring Software. Page 2 Contents  Introduction  User Interface  Service Personnel Interface  System Requirement  Demonstration.
. Error Explanation . Cautions . Solution MAP . Communication wiring
GCS Top CS Competitiveness Driven by Innovation and Challenge 1 / 12 Option Code (2011. August) GCS HQ CAC.
Chiller Panel Controller. Objectives What is the Features of Chiller Panel Controller What is the Features of Chiller Panel Controller How to use Chiller.
Page 1 Air-cooled Inverter Product Range Updated by: Yap Boon Thiam Technical Engineer Date: 14/5/2012.
DLP LCD PANEL Programming
1 THE VICTOR READER WAVE ● Plays DAISY books as well as music and books on MP3 or audio CD ● Powerful navigation features ● Go directly to any page number.
Midea WIFI air conditioner connection
TECHNICAL TRAINING SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB.
Indoor Growing Environment (IGE) Adam Wolfe (CSC) Levie Kirkland (CET) Brandon Lewis (CET)
Fan Coils Units Control
Digital Temperature Switches The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
WS50(Stratacache) Software updating guide (By Using USB)
6. Trouble Shooting Guide Breakthrough InnovationHVAC & Energy Solution 6.Trouble Shooting Guide ① You can find trouble shooting guide in General.
MCQUAY DIGITAL SCROLL SYSTEM
Service Section Technical Training December 2005.
Infrared Remote Description Remote control distance : About 5m Two modes: 1. Default control Mode( for all Panel) 2. Page control Mode ( for DLP using,
目录 12 in 1 Sensor Features ● PIR motion sensor ● Ultrasonic sensor ● LUX sensor ● Temperature sensor ● 2 Dry contacts ● 2 external condition inputs ● IR(infrared)
Multifunctional LCD Panel HDL-MPL8.48. LCD Panel Description The HDL-MPL8.48 series is a new generation of wall mounted switch, with a total of 8 metal.
1 i-Pendant for the R-J3iC & R-30iA Controllers ArcTool Version (GMAW) i Pendant New.
Horizon Photo-mote. ability to access photographs and images stored online, with the aid of a wireless remote remote enables the user to identify and.
The New Switch can replace all the Old Room Needed Controllers 1– Light Switches and Wall Dimmers 2– Air-conditioning Thermostat 3– Volume Control 4–
Problem Solving using Error Code Saijo Denki Inverter R-410A
All Freezer Advance. When the Freezer is first supplied with power or if a power outage occurs, the display will indicate this by flashing the temperature.
Service Section Technical Training. Sequential Controller SQ 1.0.
Sigma Air Manager Basic
Application Case Study Christmas Lights Controller
The New Digital Inverter Light Commercial Range
CHIGO VRF System Commissioning.
5. Outdoor unit Installation
Wireless 4 Buttons Touch Panel
Wireless 3 Buttons Touch Panel
7. Test operation.
IR Control Materials taken from a variety of sources including IR Remote for the Boe-Bot by Andy Lindsay.
Curtain Actuator M/W
P. 1 FIELD SETTINGS INDOOR UNIT : –REMOTE CONTROLLER : INSPECTION MODE, FIELD SETTING, SERVICE MODE. OUTDOOR UNIT : –PUSH BUTTON + LED INDICATION : TEST.
Call to Fix Canon Pixma MX340 printer Error 5200
सोलर पॅनेलचा उपयोग करुन रीचर्जेबल टॉर्च बनवणे.
McCrometer Nano Board Test Procedure
Setup 1; Add iMCB. Set up : Please check circuit and follow proper wiring before power up.
April 2019 FUJITSU GENERAL LIMITED
Presentation transcript:

Wireless Remote Controller (MR-AH01/BH01) HQ SE

 On/Off control  Air flow control  Temperature setting  Filter reset  Louver Control  Simple ON/OFF schedule  Service Mode - Main/RMC address check - Communication status check Features MR-AH01 MR-BH01 Main Difference  MR-AH01 : ON/OFF schedule time Increase only  MR-BH01 : ON/OFF schedule time Increase/Decrease both For MR-BH01, real time clock is not supported ! Wireless remote controller

Option code setting mode (MR-AH01) 1. Remove one battery from the wireless remote controller. 2. Press + together and put the battery back to enter the option code setting mode. 3. Use the Mode button to toggle the option code page. 4. Press the Set/Cancel button to change the option code. Toggle option code page Set option code Entering option code modeSetting option code

Option code setting mode (MR-BH01) 1. Remove one battery from the wireless remote controller. 2. Press + together and put the battery back to enter the option code setting mode. 3. Use the Mode button to toggle the option code page 4. Press Power button to change the option code. Toggle option code page Set option code Entering option code modeSetting option code Press together

Option code setting mode (Neo forte R/C) 1. Remove one battery from the wireless remote controller. 2. Press Temp ▲▼ together and put the battery back to enter the option code setting mode. 3. Set option code 2 digits. And press “Mode” and set next 2 digits. 4. Press the On/Off power button to change the option code. Entering option code modeSetting option code

4) Then “OFF timer” is displayed. 5) Set next 2 digit. 6) After setting completion, press “On/Off” ※ Only blue colored 20 digits should be set 1) Set 2 digits using Temp ▲▼ button 2) Press “Mode”, then ◀ will move to down. Set next 2 digit 3) After setting 10 digits, press “Mode” Option code setting mode (Neo forte R/C)

Service mode (MR-AH01) 1. Remote one battery from the wireless remote controller. 2. Press + together and put the battery back to enter the Service Mode. NOTE : Whenever Mode, Func1 and Func2 are changed, signal wave is transmitted from the wireless remote controller. Mode Func1 Func2 Press Set/Cancel button Entering service modeSelecting service mode

Service mode (MR-BH01) 1. Remote one battery from the wireless remote controller. 2. Press + together and put the battery back to enter the Service Mode. NOTE : Whenever Mode, Func1 and Func2 are changed, signal wave is transmitted from the wireless remote controller. Mode Func2 Press Set/Cancel button Entering service mode Func1 Selecting service mode Press together

Service mode ModeFunc1Func2Description 000 COM1 communication status (Blinking display only is valid)  Operation LED Blinking – communication status of all channels  Schedule LED Blinking – Outdoor ↔ Indoor units communication status  Fan LED Blinking – Wired remote controller ↔ Indoor units communication status  Filter LED Blinking – Interface module ↔ Indoor units communication status 010 COM1 Main Address check 020 LED display test (Rotating display) Operation LED → Schedule LED → FAN LED → Filter LED → Defrost LED All On → All Off → All On → All Off ……… MAIN address Operation LED Schedule LED FAN LED Filter LED 0OFF 1 ON 2OFF ONOFF …………… 15ON

ModeFunc1Func2Description 10x0 MAIN address assigned by outdoor unit (if in the AUTO addressing mode) (Read as decimal value) x : MAIN address of indoor unit If matched, all LEDs are lit ON. Ex) For DVM Plus II, MAIN(1) = 1, MAIN(2) =2  MAIN address = 12 11x0 RMC Address check. (Read as HEX value) x : RMC address of indoor unit If matched, all LEDs are lit ON Ex) For DVM Plus II, RMC(1)=1, RMC(2)=2  RMC address = 1* = 18 For DVM Plus II, RMC(1)=2, RMC(2)=1  RMC address = 2* = 22 13x0 Rotary switch MAIN address check (Read as decimal value) x : MAIN address of indoor unit If matched, all LEDs are lit ON Ex) For DVM Plus II, MAIN(1) = 1, MAIN(2) =2  MAIN address = 12 NOTE : Exit the service mode by pressing any general keys in the Normal mode. NOTE : Service mode 10,11 and 13 are not allowed for COM1-only indoor units. NOTE : Applied for Cassette/Duct indoor units (not for Wall-mount indoor units) Service mode