Landscape for Deemed Lighting Workpapers Building Code and Voluntary Program Relationship Building Code Changes Driven by Big Vision Voluntary Program.

Slides:



Advertisements
Similar presentations
LAMPS (Chapter 3) Lamp efficacy, life, and color Incandescent
Advertisements

Lighting Retrofits The low hanging fruit or is it? Kentucky Electric Cooperatives 2006 Key Accounts Technical Conference.
Residential Light Fixtures ENERGY STAR ® Specifications Additions to Specs Pierrette LeBlanc, Office of Energy Efficiency June 4, 2008.
T12 Replacements with HPT8s in Kitchens and Garages Regional Technical Forum October 15, 2013.
Energy Service Productivity Management ©2007 ESPM Energy Consultants, L.L.C. All Rights Reserved.
CFL ENERGY EFFICIENCY LABELLING/ PUBLIC PROCUREMENT Presented at the workshop on “energy efficient procurement” Mumbai, September 20, 2005.
LOT30 Task 8: Scenario-, policy-, impact- and sensitivity analysis First Draft.
PNM Energy Efficiency Business Rebates for Facility Managers Retrofit Rebate Opportunities July 13, 2010.
Commercial Energy Efficiency Program IFMA Luncheon July 16, 2014.
The LOWEST COST LIGHTING SOLUTION Comparison Presentation.
D EEMED M EASURE U PDATES June 1, 2011 Regional Technical Forum Presented by: Bob Tingleff SBW Consulting, Inc.
City of Boulder Meeting Kyoto -- Carbon Emissions Reduction: Commercial Lighting.
Energy-Saving Lighting Options. Lighting Facts Accounts for 20% to 25% of all electricity used Average household spends 5% to 10% on lighting More energy.
Lighting Calculations
Energy retrofit solution for 400w MH Highbays!! Question:How many fixture lumens do you need to replace one 400w MH highbay? Answer:About 20,000 lumens.
Why BoldPlay? Brilliant Design. Intuitive Engineering Innovation + Design = Performance Serious Energy Savings Ideal direct/indirect distribution maximum.
State Incentives for Energy Efficiency Commercial and Industrial New Jersey Board of Public Utilities Office of Clean Energy Mona L. Mosser Bureau of Energy.
Lighting Retrofit Training.  Know and understand your local power company incentive program. KEMA is a federal organization that administers several.
Grocery Measure: LEDs for Reach-In Display Cases Regional Technical Forum July 21 st, 2015 Mohit Singh-Chhabra.
1 Using Webcrawlers to Estimate Incremental Measure Costs for the Retail Plug-Load Portfolio (RPP) Program November 21, 2014.
LED Case Lighting With and Without Motion Sensors Michele Friedrich – Sr. Engineer PECI 1/5/2010.
Put Your Business in the Best Light Commercial and Industrial Lighting Program.
2009 CAMPUS LIGHTING RETROFIT FORUM Laboratory Lighting Controls Upgrade New Laboratory Building Biological Sciences 3 Beat Title 24 Energy Standard by.
Photometric Data Photometry is the science of measurement of light.
Energy Conservation Western North Carolina Recycler’s Networking Council Black Mountain, North Carolina December 9, 2004 Keyes McGee, E.I. North Carolina.
Artificial Lighting Design Task lighting for general purpose rooms involves the installation of light sources that will provide the optimum amount of.
FLUORESCENT LUMINAIRES Fluorescent Luminaires U.S. Department of Energy Rebuild America Business Partners And Lithonia Lighting.
LED Case Lighting in Vertical and Semi-Vertical Open Refrigerated Cases Eric Mullendore – Energy Analyst PECI 6/29/2010.
Objectives Talk about grades Talk about project and field trip Review important lectures.
Main Headquarters: 120 Water Street, Suite 350, North Andover, MA With offices in: NY, ME, TX, CA, OR Standard Protocol for Non-Residential.
Saving Energy and Improving Light Quality in Street Lighting P K Mukherjee Amit Khare CLASP Applications of the SEAD Street Lighting Tool Clean Energy.
The savings with energy efficient LED lighting is realized before the first fixture is turned on.
Deemed Savings Update: ECMs in Display Cases Ben Cartwright PECI January 5, 2009.
INTD 51 the functions of illumination lighting can be a tremendous force in architectural, interior, and landscape design.
PAGE 1 Sustainable Buildings 2030 © 2008 THE WEIDT GROUP Building Energy Benchmarks THE WEIDT GROUP.
T12 to HPT8 Change-outs Small/Rural request for development May 15, 2012.
SPARTA | Fall 2014 LED Retrofit Capabilities at MSU (Revisited)
Northwest Power and Conservation Council A Look At The Council’s Conservation Planning Methodology and Assumptions A Look At The Council’s Conservation.
Advanced Lighting Control Systems (ALCS) Energy Estimation Tool Pacific Gas & Electric Company Dave Alexander.
RTF Residential Lighting Subcommittee Tuesday, March 4, 11am – 12:30pm 1.
Residential LED Fixtures Research Discussion Research and Evaluation Subcommittee January 8, 2016.
Objectives Learn about lighting design.
RTF Management Updates Jennifer Light Regional Technical Forum January 21, 2016.
Exterior LED Area Lights
Lighting facts.  Lighting can be a big energy consumer in offices and production areas and experience shows that energy savings may be achieved - often.
National Approaches to Networked Lighting Systems DLC’s CALC Project and Examples from Outside California October 20, 2015.
Making Sense of the Ever-Changing LED Technology FMA Future Facilities Summit in Chicago May 28, 2015.
Why Lighting Matters Win with LED Technology TODAY! John Dombrowski The information in this document is confidential and proprietary, and may not be used,
November 2, 2011 Comprehensive Lighting: Solutions for the Greater Good David Landers Manager, Business Energy Management Efficiency Connections Northwest.
| 1 Distributor Training Presentation EVERLINE LED Sign Tubes.
PAURAVI SHAH IOU WATTAGE RANGE METHOD(WRM) WORKING GROUP: HENRY LIU(PG&E), PAURAVI SHAH(PG&E),MINI DAMODARAN(PG&E), THOMAS PASKER, AJAY WADHERA (SCE),
| 1 Universal Lighting Technologies ULT Marketing Lamp Training.
Prescriptive Residential and Nonresidential Programs
Updated HID Ballast Efficiency Regulations
Agenda » General Methodology » Approaches to Key Issues
Incandescent Light Bulb LUMEN DESIGN METHOD Where: N = E A F UF LLF N = number of lamps E = level of illuminance A = Area at working plane.
ART 2640, Building Systems of Interior Environments Fall Semester 2016 Tuesdays & Thursdays 9:00-10:20 Grover Center E218 Matthew Ziff, Associate Professor.
2017 Commercial Energy Efficiency Program
Calculating Payback Period
CAPE & OUR PPN HISTORY IN BUSINESS SINCE 1953, PPN MEMBER SINCE 2014
Economics of Energy Efficient Lighting
Regional Sales Manager
NATIONAL LIGHTING CODE
Regional Sales Manager
Point-by-Point Factors
Regional Sales Manager
Technology in Architecture
Objectives Learn about lighting design.
Announcement Next class: 15 minutes quiz
Regional Sales Manager
Presentation transcript:

Landscape for Deemed Lighting Workpapers Building Code and Voluntary Program Relationship Building Code Changes Driven by Big Vision Voluntary Program Driven by Least Common Denominator Most Conservative Assumption = Low savings Low Savings = Low Rebate Low Rebate = Lost Opportunity to influence purchasing There is a technical challenge in identifying the energy savings that can justify an effective rebate for the market while accounting for the real implications of energy codes.

Downstream Incentive Mechanism These deemed incentives are intended to be simple and broadly applicable: The measure case is driven by a minimum equipment specification. Customer completes application after purchasing qualifying equipment: Verification of equipment qualification should be as simple as possible Only required documentation is customer-provided invoice: Incentive should depend on the manufacturer, model & quantity Customer location, market segment, and other details can be determined by processing center: Invoice review verifies the equipment specification of the installed equipment via applicable industry resources. Account information is used to determine market segment and climate zone. The base case technology, specific application and wattage are unknown. The program has no way to determine specific application: A 2x4 troffer at an office location may be installed in a hallway, private office, or stairwell. A 2x4 troffer at a retail location is located in the office, retail floor, or breakroom. Incentive savings should represent overall characteristics for the location type

Other Assumptions beyond today’s scope Generally downstream measures assume ROB (Replace on Burnout— i.e. the fixture could not be relamped/reballasted), claiming only the energy savings from code to proposed. Code baseline calculations assume every project would trigger code and 100% of the projects would be code compliant. 40 fixtures is generally the trigger point T24 code

Key Challenge for Interior Lighting Recessed lighting is a key area of product growth LED technology is making significant retrofit savings available: DLC- listed recessed products average 93 fixture lumens / Watt But what is the code baseline assumption for a new recessed fixture? Title 24 provides only lighting power densities: We looked at the CASE Reports (Codes and Standards Enhancement) written to justify savings and feasibility of Title 24 updates Goal is to provide fluorescent fixture performance against which any LED recessed fixture performance can be measured

Choice of Comparison Metric Coefficient of UtilizationFixture Efficacy (lm/W) Availability for baseline products CU is often not present on fluorescent fixtures; industry moving towards modeling Calculable from spec sheets (lamp lumens x lamp qty x BF x fixture efficiency) Availability for LED products Not availableReadily available, 3 rd -party verified and listed by DLC Variability by room geometry for a given fixture Can vary from 30% - 80% based on room geometry & reflectances Does not vary by room geometry Correlation with actual task illuminance ExcellentLess strong; best for large open spaces and high reflectances Potential Variations DLC also lists lumen output in the ⁰ zone, even more highly correlated with horizontal illuminance Base case vs. measure fixture comparison via either Fixture Efficacy or Coefficient of Utilization (CU = ratio of lumens hitting task plane to lumens existing lamp):

T compliant Basecase Fixture Wattages Indoor Lighting CASE Reports for T were based on an office lighting layout from an actual building: – “fixtures are ‘high performance T8’ fixtures, i.e. they are compliant with the…new Federal lamp standard” We suggest using this fixture type to define a energy savings baseline for code-compliant recessed lighting fixtures which can be compared to measure case performance of LED troffers There are many possible options for fixture layouts and space geometries, but the model in this case report was selected as representative of a variety of interior applications.

T compliant Basecase Fixture Wattages Complete Building LPD for Offices: 0.8 W – (Area Category Method blend for offices: 0.86 W) The modeled fixtures contain HPT8 lamp & ballast: – 3T8 Parabolic Troffer with 3100-lm lamps – 72 Watts – 8’ x 10’ spacing – 43.9 maintained footcandles on workplane – 0.59 Coefficient of Utilization There are many possible options for fixture layouts and space geometries, but we can compare these fixtures to modern LED troffers on the basis of efficacy in lumens per Watt.

T compliant Basecase Fixture Wattages The 2x4 troffer in the CASE model most closely resembles the Cooper 2P2GAX-332S36I: – /products/documents/metalux/spec_sheets/090386_2P2GAX33 2_3L_T8_18C.pdf /products/documents/metalux/spec_sheets/090386_2P2GAX33 2_3L_T8_18C.pdf – roducts/recessed_linear_lighting/parabolics/_ ssd.html roducts/recessed_linear_lighting/parabolics/_ ssd.html – Also closely resembles Fixture #24 in the IES 9 th Edition Handbook, p. 414 Using either of the above as models, the fixture efficacy would be 74.7% (ratio of lamp lumens to fixture lumen output) – This yield a 68.5 lm/W fixture efficacy at initial conditions

Base case efficacy & Energy Savings 68.5 lu/W for 2x4 fixtures suggests 16.5 lu/W improvement from T24-compliant baseline to DLC-minimum of 85 lu/W – Average DLC-listed fixture has measured efficacy of 92.3 lu/W – 1x4 and 2x2 fixture efficacies in the 2P2GAX parabolic line are similar and lower, so using the 2x4 for the baseline will yield a conservative estimate 66.5% for 1x4 232S113I; 72.2% for 2x2 2U1-5/8S33I232S113I2U1-5/8S33I Both fixtures provide 40 fc illuminance with 80/50/20 reflectances at 0.72 W/sq.ft. N.B.: Using a fixture efficacy comparison would not work well for fixtures with highly specific distribution requirements or vertical illuminance requirements such as warehouse aisles: this analysis is for horizontal average illuminance only