B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee1 Neutron detection efficiency of the KLOE calorimeter B.Sciascia (LNF  INFN) for the KLONE.

Slides:



Advertisements
Similar presentations
Advanced Neutron Spectrometer (ANS) Geant4 Simulations
Advertisements

NDVCS measurement with BoNuS RTPC M. Osipenko December 2, 2009, CLAS12 Central Detector Collaboration meeting.
Stefan Roesler SC-RP/CERN on behalf of the CERN-SLAC RP Collaboration
Study of plastic scintillators for fast neutron measurements
Multi Pixel Photon Counters (MPPC) and Scintillating Fibers (Sci-Fi)
Neutron background measurements at LNGS Gian Luca Raselli INFN - Pavia JRA1 meeting, Paris 14 Feb
Hall D Photon Beam Simulation and Rates Part 1: photon beam line Part 2: tagger Richard Jones, University of Connecticut Hall D Beam Line and Tagger Review.
Y. Karadzhov MICE Video Conference Thu April 9 Slide 1 Absolute Time Calibration Method General description of the TOF DAQ setup For the TOF Data Acquisition.
Luminosity Monitors MICE Video Conference 7 May 2009 Paul Soler.
Study of two pion channel from photoproduction on the deuteron Lewis Graham Proposal Phys 745 Class May 6, 2009.
The Time-of-Flight system of the PAMELA experiment: in-flight performances. Rita Carbone INFN and University of Napoli RICAP ’07, Rome,
RF background, analysis of MTA data & implications for MICE Rikard Sandström, Geneva University MICE Collaboration Meeting – Analysis session, October.
Atmospheric Neutrino Oscillations in Soudan 2
The Transverse detector is made of an array of 256 scintillating fibers coupled to Avalanche PhotoDiodes (APD). The small size of the fibers (5X5mm) results.
The PEPPo e - & e + polarization measurements E. Fanchini On behalf of the PEPPo collaboration POSIPOL 2012 Zeuthen 4-6 September E. Fanchini -Posipol.
Abstract A time resolved radial profile neutron diagnostic is being designed for the National Spherical Torus Experiment (NSTX). The design goal is to.
Study of response uniformity of LHCb ECAL Mikhail Prokudin, ITEP.
A scintillation detector for neutrons below 1 MeV with gamma-ray rejection Scintillators are 3 mm BC408, 10 layers total Adjacent layers are optically.
14/02/2007 Paolo Walter Cattaneo 1 1.Trigger analysis 2.Muon rate 3.Q distribution 4.Baseline 5.Pulse shape 6.Z measurement 7.Att measurement OUTLINE.
Journées GDR Nucléon - Instrumentation April 8-9, 2008 – Saclay M.Anelli, G.Battistoni, S.Bertolucci, C.Bini, P.Branchini, C.Curceanu, G.De Zorzi, A.Di.
Possibilities of TOF measurements on NPI neutron generators Mitja Majerle Department of Nuclear Reactions Nuclear Physics Institute ASCR.
1 Report on analysis of PoGO Beam Test at Spring-8 Tsunefumi Mizuno July 15, 2003 July 21, 2003 revised August 1, 2003 updated.
NESTOR SIMULATION TOOLS AND METHODS Antonis Leisos Hellenic Open University Vlvnt Workhop.
Neutron detection in LHe ( HMI run 2004) R.Golub, E. Korobkina, J. Zou M. Hayden, G. Archibold J. Boissevain, W.S.Wilburn C. Gould.
Shashlyk FE-DAQ requirements Pavel Semenov IHEP, Protvino on behalf of the IHEP PANDA group PANDA FE-DAQ workshop, Bodenmais April 2009.
Measurement of the neutron detection efficiency of the KLOE calorimeter P.Gauzzi (Universita’ La Sapienza e INFN – Roma) for the KLONE Group 10 th ICATPP.
Anna Ferrari VCI 2007, Wien, February 22nd, Measurement and simulation of the neutron response and detection efficiency of a Pb – scintillating.
Apollo Go, NCU Taiwan BES III Luminosity Monitor Apollo Go National Central University, Taiwan September 16, 2002.
Experimental Nuclear Physics Some Recent Activities 1.Development of a detector for low-energy neutrons a. Hardware -- A Novel Design Idea b. Measure the.
Nov Beam Catcher in KOPIO (H. Mikata Kaon mini worksyop1 Beam Catcher in the KOPIO experiment Hideki Morii (Kyoto Univ.) for the KOPIO.
Measurement and simulation of neutron detection efficiency in lead-scintillating fiber calorimeter Active material:  1.0 mm diameter scintillating fiber.
Hadronic interaction studies with the ARGO-YBJ experiment (5,800 m 2 ) 10 Pads (56 x 62 cm 2 ) for each RPC 8 Strips (6.5 x 62 cm 2 ) for each Pad ( 
1 NaI calibrationneutron observation NaI calibration and neutron observation during the charge exchange experiment 1.Improving the NaI energy resolution.
Total photoabsorption on quasi free nucleons at 600 – 1500 MeV N.Rudnev, A.Ignatov, A.Lapik, A.Mushkarenkov, V.Nedorezov, A.Turinge for the GRAAL collaboratiion.
Progress on F  with the KLOE experiment (untagged) Federico Nguyen Università Roma TRE February 27 th 2006.
00 Cooler CSB Direct or Extra Photons in d+d  0 Andrew Bacher for the CSB Cooler Collaboration ECT Trento, June 2005.
T. Lari – INFN Milan Status of ATLAS Pixel Test beam simulation Status of the validation studies with test-beam data of the Geant4 simulation and Pixel.
M.Anelli, G.Battistoni, S.Bertolucci, C.Bini, P.Branchini, C.Curceanu, G.De Zorzi, A.Di Domenico, B.Di Micco, A.Ferrari, S.Fiore, P.Gauzzi, S.Giovannella,F.Happacher,
Luminosity Monitor Design MICE Collaboration Meeting 31 May 2009 Paul Soler.
 0 life time analysis updates, preliminary results from Primex experiment 08/13/2007 I.Larin, Hall-B meeting.
Simultaneous photo-production measurement of the  and  mesons on the nucleons at the range 680 – 1500 MeV N.Rudnev, V.Nedorezov, A.Turinge for the GRAAL.
MEG 実験 2009 液体キセノン検出器の性能 II 西村康宏, 他 MEG コラボレーション 東京大学素粒子物理国際研究セン ター 第 65 回年次大会 岡山大学.
Paolo Massarotti Kaon meeting March 2007  ±  X    X  Time measurement use neutral vertex only in order to obtain a completely independent.
ArgonneResult_ ppt1 Comparison of data and simulation of Argonne Beam Test July 10, 2004 Tsunefumi Mizuno
1 Cosmic Ray Physics with IceTop and IceCube Serap Tilav University of Delaware for The IceCube Collaboration ISVHECRI2010 June 28 - July 2, 2010 Fermilab.
3/06/06 CALOR 06Alexandre Zabi - Imperial College1 CMS ECAL Performance: Test Beam Results Alexandre Zabi on behalf of the CMS ECAL Group CMS ECAL.
Tracker Neutron Detector: INFN plans CLAS12 Central Detector Meeting - Saclay 2-3 December 2009 Patrizia Rossi for the INFN groups: Genova, Laboratori.
Simulation and reconstruction of CLAS12 Electromagnetic Calorimeter in GSIM12 S. Stepanyan (JLAB), N. Dashyan (YerPhI) CLAS12 Detector workshop, February.
Monte Carlo methods in spallation experiments Defense of the phD thesis Mitja Majerle “Phasotron” and “Energy Plus Transmutation” setups (schematic drawings)
ICARUS T600: low energy electrons
The PSD at Pb-Pb run PSD drawbacks at Ar beam
Study of Hypernuclei with Heavy Ion Beams (HypHI) at GSI Shizu Minami GSI, Germany on behalf of HypHI collaboration Introduction Phase 0 experiment R.
at TSL high energy neutron facility
Cross-section Measurements of (n,xn) Threshold Reactions
Dr. Mikhail Runtso, Mr. Pavel Naumov,
Luminosity Monitor Status
Filimon Roukoutakis, MC-PAD ITN ER
Tracking System at CERN 06 and 07 test beams
Central detector for CLAS12: CTOF and Neutron detector
an ecofriendly possibility
Neutron detection efficiency of the KLOE calorimeter
Very high efficiency, about 4 times
Single trigger, no target
LNF - Beam Test Facility Sept. 29 – Oct. 04
Timing Counter Sept CSN I, Assisi 2004 Giorgio Cecchet.
p0 life time analysis: general method, updates and preliminary result
Времяпролетный детектор PANDA
Measurement and simulation of neutron detection
O. Svoboda, A. Krása, A. Kugler, M. Majerle, J. Vrzalová, V. Wagner
A Neutron Counter for the CLAS12 Central Detector
Presentation transcript:

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee1 Neutron detection efficiency of the KLOE calorimeter B.Sciascia (LNF  INFN) for the KLONE Group XXXIII LNF Scientific Committee Open session 27 November 2006

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee2 Outline The KLONE (KLOe Neutron Efficiency) group measured the neutron detection efficiency of a KLOE calorimeter prototype, at The Svedberg Laboratory (TSL), Uppsala. Reasons behind the formation of the KLONE group. Characteristic of the neutron source at TSL. Experimental setup. Measurements: Method Neutron detection efficiency for a 5 cm thick scintillator. Calorimeter neutron detection efficiency, preliminary results. Neutron energy spectrum from Time of Flight, preliminary results. Monte Carlo: Some comparisons between data and “fast” Monte Carlo. Detailed beam line and calorimeter simulation. Physical processes behind the test beam results.

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee3 The reasons behind KLONE Preliminary measurement with KLOE data and MC (neutron are produced by K  interactions with the beam pipe and inner DC walls) showed an efficiency of  40%, larger than the expected  10% if only the amount of scintillator is taken into account. (B. Sciascia, Thumb rule: efficiency scales with scintillator thickness (1%/cm). Several works in literature mention an enhancement of neutron detection efficiency for fast neutron in presence of high Z materials, particularly lead (e.g. see M.Pelliccioni et al., NIMA 297 (1990) ). KLOE calorimeter has very good time resolution, good energy resolution, and high efficiency for photons. With high neutron detection efficiency, could be also the first of a new kind of neutron detectors. High neutron detection efficiency is relevant for the future experiments at LNF: AMADEUS: study of deeply bound kaonic nuclei. DANTE: measurement of nucleon time  like form factors.

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee4 KLONE group Funding: Use as much as possible already existing material. Got some INFN funds: CSN5, DR LNF, KLOE, AMADEUS. Got CEE funds via TARI projects. A lot of help for: Mechanic: G.Bisogni, U.Martini et al. Electronics: A.Balla et al. Detector support: M.Anelli, A.DiVirgilio et al. Transports: M.Rossi, P.Caponera. Interesting and useful interactions with TSL group.

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee5 Neutron source (TSL) Neutron beam from MeV protons on 7 Li target. 42% of neutrons at max energy. Calorimeter at  5 m from target. Absolute neutron flux in the peak measured after the last collimator by 3 beam intensity monitor: better accuracy  10%. E KIN (MeV)

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee6 Experimental setup and data set (1) (3) (2) 1. Old KLOE calorimeter prototype, 3×5 cells (4.2×4.2cm 2 ), 60 cm long, read out at both ends by Hamamatsu/Burle PMTs. 2. Beam position monitor: array of 7 scintillating counters, 1 cm thick. 3. Reference counter: NE110, 5 cm thick, 10×20 cm 2. A rotating frame allows for vertical (data taking with n beam) and horizontal (for calibration with cosmic rays) positions. 3 large data sets collected with different beam intensity: low (1.5 kHz/cm 2 ), medium (3.0 kHz/cm 2 ), and high (6.0 kHz/cm 2 ) For each configuration, several trigger threshold scans. Typical run: Mevents, 1.7 kHz DAQ rate. Cosmic rays run (beam off) for calibrations with MIPs.

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee7 Method of measurement f LIVE Thr (mV)  = R TRIGGER R NEUTRON × f LIVE ×  R NEUTRON : From beam monitor via neutron flux intensity measured by TSL. R TRIGGER : use coincidence between sides. Scintillator: T1 = Side 1×Side 2. Calorimeter: use the analog sum of 12 PMs/side (first four planes); sum are first discriminated and formed: T1 =  A×  B f LIVE : live time fraction  : for preliminary measurement, assume full acceptance and no background. Global (no energy dependency) efficiency measurement:

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee8 Scintillator efficiency - 1 Good check of the measurement method, even if the live time fraction is high in almost all acquired runs. Calibration of the energy scale with a 90 Sr  source. 10% accuracy for both vertical (  ) and horizontal (Threshold) scales. Thr (MeV e  equiv. energy)  (%)

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee9 Scintillator efficiency - 2 The comparison with previous published measurements in the same energy range, by scaling them to our thickness, is good within the errors. Agrees with thumb rule (1%/cm): 5% for 5 cm thick scintillator (with a threshold of  2.5 MeV electron equivalent energy) Thr (MeV e  equiv. energy)  (%)

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee10 Calorimeter efficiency - 1 Energy scale set using the conversion factor from KLOE. 10% uncertainty on both horizontal and vertical scales. Stability wrt very different run conditions: a factor 4 variations of both live time fraction (e.g. f LIVE =0.2  0.8) and beam intensity (1.5  6.0 kHz/cm 2 ). Small efficiency decrease with high beam intensity; possible pile-up effects, have to be studied.  (%) Thr (MeV e  equiv. energy)

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee11 Calorimeter efficiency - 2 Very high efficiency, about 4 times larger than the expected if only the amount of scintillator is taken into account: 8% for 8 cm of scintillating fibers. Compare with our scintillator efficiency measurement, scaled by the scintillator ratio factor 8/5  (%) Thr (MeV e  equiv. energy)

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee12 Neutron spectrum from ToF - 1 n a) b)c) d) For the 3 cells of first calorimeter plane: Correct raw spectra (a) for T0 (b) and convert into ns (c) TDC spectra of single cell show a 41 ns time structure (from phase locking). Has to be corrected for wrong clock association (d). At  5 m from target, rephasing needed for n kinetic energies less than 50 MeV.

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee13 Neutron spectrum from ToF - 2 e) f) E KIN (MeV) From ToF spectrum obtain velocity spectrum (e). Assuming neutron mass determine kinetic energy spectrum (f). Compare with the input theoretical n spectrum. The “per cell” exercise has to be repeated for the whole calorimeter after the cluster procedure definition.

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee14 Data – fast MC comparison For the central cell of the first plane, compare data with fast MC. Assume a n efficiency as function of the kinetic energy. Data-MC comparison of time, velocity, and kinetic energy distributions (dots are Data, line is MC). Other shapes of the efficiency curve have been tested, obtaining a worse agreement between Data and Mc. E KIN (MeV) ns  (E KIN ) 

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee15 MC: detailed simulation 7 Li Target Shielding (concrete and steel) Calorimeter Using Fluka code, simulate a detailed description of the main elements of the beam line (source, collimator, shielding,…) and of the calorimeter: KLOE simulation: lead-scintillator layers. New simulation, using lattice tool, design the fiber-lead structure.

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee Don’t interact:  14 % Elastic (%)Inelastic (%) Lead32.6 (1.5)31.4 (1.5) Fiber10.4 (1.0)7.0 (0.8) Glue2.3 (0.5)2.2 (0.5) From the simulation of a sample of 1000 monoenergetic (180 MeV) neutrons:  10% elastic processes within the scintillator: could produce the “expected” efficiency.  31% inelastic processes within lead: produce the “unexpected” efficiency rise. The energy is deposited by photons and protons. Also low energy neutrons contribute because of the rise of n-p cross section for low energy neutrons. In average, 5.4 secondary particles per primary n are generated in inelastic interactions, counting only neutrons above 19.6 MeV. The interactions of low energy (E n <19.6 MeV) secondary neutrons produce, in average, 97.7 secondary particles per primary neutron. MC: physical processes Secondary (%) (E n >19.6MeV) Secondary (%) (E n <19.6MeV) n  p6.81.1

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee17 Conclusions and future plans The preliminary measurement of the neutron detection efficiency of the KLOE calorimeter, done using KLOE data, has been confirmed by the test beam at TSL. The preliminary results show an efficiency 4-5 times larger than the expected if only the amount of scintillator is taken into account. For comparison the efficiency of the 5 cm thick NE110 scintillator has been measured, and turns out to be about 5% as expected. The results are in agreement with recent simulations based on Fluka. Complete simulations of the calorimeter and the beam line will allow to better understand the efficiency increase. Apparently the inelastic interactions of the neutrons on lead produce a large amount of secondary particles. The high sampling frequency of the calorimeter allows the detection of such particles. We plan to complete the analysis of TSL data in the next months. A new test beam is foreseen (summer 2007) at Louvain (Belgium) to extend the investigation to lower kinetic energies (down to 10 MeV) and to improve the knowledge of the energy dependency of the neutron efficiency.

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee18 Spare slides

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee19 Neutron source details (TSL) Both TSL (Uppsala) and Louvain source look reasonable. Louvain could not be used before 2007 (T MAX =68 MeV) No beam extraction signal. n are produced with proton on 7 Li target, 3 m collimator, sweep magnet. n energy peaked at cyclotron energy; low energy tail. n timing phase-locked to main cyclotron RF with narrow pulse duration:  TOF =1.5  3 ns. Beam spot increases linearly with distance from target: use a circular collimator 2 cm diameter at 3 m. Approved on 18 May 2006: code F183 assigned Allocated beam time: October 2006, 8 shifts of 8 hours assigned. Cost: 400 Euro/hour (half paid on TARI)

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee20 Details on DAQ Scintillator trigger: Side 1 – Side 2 coincidence (T1=S1×S2) Calorimeter trigger: based on analog sum of the signals of the first 4 plan out of 5 (T1=  A×  B). Trigger signal is phase locked with RF signal (T1 free). Vetoed from retriggering by a 5-35  s busy signal and by the DAQ busy. The final trigger signal is: T2 = T1free.AND.NOT(BUSY). T1free, T2, and the n monitor signals are acquired by a scaler asynchronous from DAQ. Fraction of live time: T2/T1free; essential for the efficiency evaluation. T2/T1 FREE Thr (mV) Neutron rate proportional to neutron monitor via neutron flux intensity (I 0 ) and peak fraction (f P ) An absolute rate calibration should be provided by scintillator counter. Calorimeter scintillator efficiency rate is almost independent from beam monitor.

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee21 Time structure 4.2 ms 2.4 ms 40 ns 41 ns  5 ns FWHM RF Macro structure Calorimeter Trigger signal

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee22 Test of phase locking Beam RF T1(Free) Test done with a random trigger at 60KHz

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee23 S 1 (ADC counts) Thr (mV) 1.15 count/mV 1.02 count/mV S 2 (ADC counts) Thr (mV) Trigger threshold calibration: mV to ADC counts Scintillator calibration  source to set the energy scale in MeV: 90 Sr   endpoint MeV; 90 Y   endpoint MeV. Fit of the b spectrum, with ADC counts to MeV factor as a free parameter MeV/count MeV/count ADC counts S1S1 S2S2

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee24 Calorimeter calibration  A  1.6 count/mV  B  2.0 count/mV ADC counts mV Cell response equalized: MIP peak at  600 ADC counts. Trigger threshold calibration: - HP attenuators used for  A and  B not to exceed the dynamic range of the ADC; different attenuation factors: f A =2.0, f B = Threshold in counts studied with different methods. Energy scale set with MIPs using the conversion factor from KLOE: a MIP in a calorimeter cell corresponds to an electron of 35 MeV.

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee25 Raw TDC spectrum, no T0

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee26 Raw TDC spectrum, T0 corr.

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee27 TDC spectrum, not rephased

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee28 TDC spectra, RF rephased

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee29 Velocity spectrum

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee30 Kinetic energy spectrum

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee31 Data – fast MC comparison - 2 Worse agreement if we assume an efficiency increasing with energy. E KIN (MeV) ns  (E KIN ) 

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee32 Clustering For each side: group adjacent cells in “side cluster”. For event with at least a “side cluster” on each side, compute “event cluster” information.

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee33 Weighed energy average on cell: 0 X Side A: x and z coordinates 0 Z

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee34 Weighed energy average on cell:Sum of cell energies: Side A: time and energy

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee35 n Cluster: coordinates Y X Z 0 0

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee36 Cluster: time and energy

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee37 Signal development time - 1 n Time difference between a cluster in one of the first four plans (trigger) and one in the fifth plane. As a reference, KLOE expected time resolution for 5-20 MeV photons is ns. ns

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee38 Signal development time - 2 ns Difference between the cluster time (computed as energy weighed average) and the time of the cell making up the cluster itself. As a reference, KLOE expected time resolution for 5-20 MeV photons is ns.

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee Energy response 180 MeV neutrons MC energy distribution is too broaden and no energy direct measurement can be done. Little correlation between released and incident energies. Data energy distribution peaked at  20 MeV.

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee40 Calorimeter details 1.2 mm 1.35 mm 1.0 mm 1 mm diameter scintillating fiber (Kuraray SCSF-81, Pol.Hi.Tech 0046), emitting in the blue-green region, Peak <460nm. 0.5 mm lead grooved layers (95% Pb and 5% Bi). Glue: Bicron BC-600ML, 72% epoxy resin, 28% hardener. Core: polystyrene,  =1.050 g/cm 3, n=1.6 Cladding: PMMA, n=1.49 Only  3% of produced photons are trapped in the fiber. But: small transit time spread due to uni-modal propagation at 21 , small attenuation ( =4-5m), optical contact with glue (n GLUE  n CORE ) remove cladding light  TR = 21  cladding core 36 

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee Details on calorimeter simulation Old simulation: lead-scintillator layers (GEANT3) New simulation: with FLUKA, using lattice tool, the fiber-lead structure has been designed and replicated 200 times. Active material (fibers + cladding): polystyrene C 2 H 3 homogeneous material with  =1.044 g/cm 3 (average between cladding and core). Passive materials: lead foils, 95% Pb and 5% Bi homogeneous compound. Glue: 72% epoxy resin C 2 H 4 O,  =1.14 g/cm 3, 28% hardener,  =0.95 g/cm 3, hardener details: GLUEFIBRES LEAD Base module (198 fibers): 200 layer replicas: PolyoxypropylediamineC 7 H 20 NO 3 90% TriethanolamineC 6 H 15 NO 3 7% AminoehylpiperazineC 6 H 20 N 3 1.5% DiethylenediamineC 4 H 10 N 2 1.5%

B. Sciascia 27 November 2006, XXXIII LNF Scientific Committee without Birks effect Birks effect is important for neutron detection: the energy is released essentially by protons. Birks parameters highly dependent from the scintillating material Can be measured on KLOE data using protons from Da  ne machine background (photo production on beam pipe and quadrupoles), see: C. Bini, MC details: Birks parameters