Www.disp.duke.edu Near Field Photonic Crystal Multi- Mode Spectrometer Adam Saltzman 4/19/02 BME 265 Dr. J Izatt Collaborators: Vasily Astratov UNC Chalet,

Slides:



Advertisements
Similar presentations
The Film Camera.
Advertisements

Digital Camera Essential Elements Part 1 Sept
The Microscope.
Blizard Advanced Light Microscopy club Making friends with your microscope.
Motivation Spectroscopy is most important analysis tool in all natural sciences Astrophysics, chemical/material sciences, biomedicine, geophysics,… Industry.
Optical Astronomy Imaging Chain: Telescopes & CCDs.
427 PHC.  Atomic emission spectroscopy (AES) is based upon emission of electromagnetic radiation by atoms.
ABRF meeting 09 Light Microscopy Research Group. Why are there no standards? Imaging was largely an ultrastructure tool Digital imaging only common in.
Optics and Telescopes Chapter 5 Survey of Astronomy om astro1010-lee.com.
R. Hui Photonics for bio-imaging and bio- sensing Rongqing Hui Dept. Electrical Engineering & Computer Science, The University of Kansas, Lawrence Kansas.
Pore Detection in Small Diameter Bores The University of Michigan, Ann Arbor NSF Engineering Research Center for Reconfigurable Manufacturing Systems.
1 Earth’s Atmosphere & Telescopes Whether light is absorbed by the atmosphere or not depends greatly on its wavelength. Earth’s atmosphere can absorb certain.
Remote sensing in meteorology
Light and Telescopes Chapter 5. Traditional Telescopes The 4-m Mayall Telescope at Kitt Peak National Observatory (Arizona)
Exam II Review. Review of traveling wave interference Phase changes due to: Optical path length differences sources out of phase General solution.
Fluorescence. Topics Sensitivity (nM-pM) –Contrast UV-vis measurements Derivatization Laser-Induced Fluorescence.
1 Computer Science 631 Lecture 6: Color Ramin Zabih Computer Science Department CORNELL UNIVERSITY.
Methods Eye (visible window) Camera – film Camera – CCD (Digital) Collecting Electromagnetic Information.
Astronomical Spectroscopy
Ch 25 1 Chapter 25 Optical Instruments © 2006, B.J. Lieb Some figures electronically reproduced by permission of Pearson Education, Inc., Upper Saddle.
14.2 Data Capture Digital Imaging using CCDs. Capacitors  A capacitor is a device that stores charge.  Def’n of Capacitance - The ratio of the charge.
Digital Technology 14.2 Data capture; Digital imaging using charge-coupled devices (CCDs)
Digital Cameras (Basics) CCD (charge coupled device): image sensor Resolution: amount of detail the camera can capture Capturing Color: filters go on.
Question 1 Modern telescopes use mirrors rather than lenses for all of these reasons EXCEPT 1) Light passing through lenses can be absorbed or scattered.
Introduction to Machine Vision Systems
Digital Photography Fundamentals Rule One - all digital cameras capture information at 72 dots per inch (DPI) regardless of their total pixel count and.
Lens ALens B Avg. Angular Resolution Best Angular Resolution (deg) Worst Angular Resolution (deg) Image Surface Area (mm 2 )
Microscope.
1 CCTV SYSTEMS CCD VERSUS CMOS COMPARISON CCD (charge coupled device) and CMOS (complementary metal oxide semiconductor) image sensors are two different.
Chapter 25 Optical Instruments.
Atomic Emission Spectroscopy
Astronomical Instrumentation Often, astronomers use additional optics between the telescope optics and their detectors. This is called the instrumentation.
Telescopes & Light: Part 1. A Telescopes is a tool used to gather light from objects in the universe.
Chapter 6: The Tools of the Astronomer. Telescopes come in two general types Refractors use lenses to bend the light to a focus Reflectors use mirrors.
Measurements in Fluid Mechanics 058:180 (ME:5180) Time & Location: 2:30P - 3:20P MWF 3315 SC Office Hours: 4:00P – 5:00P MWF 223B-5 HL Instructor: Lichuan.
Dr. Andrew Tomasch 2405 Randall Lab
Miriam Israelowitz 1 and Dr. David L. Wilson 2 1 Department of Physics, Case Western Reserve University, Cleveland OH, 2 Deparment of Biomedical Engineering,
Astrophotography The Basics. Image Capture Devices Digital Compact cameras Webcams Digital SLR cameras Astronomical CCD cameras.
Digital Cameras, Digital Video and Scanners Vince DiNoto
Simple Double Beam Spectrometer
Simple Double Beam Spectrometer
A Multi-Spectral Structured Light 3D Imaging System MATTHEW BEARDMORE MATTHEW BOWEN.
Figure 8.Color map of the geometric correction along the dispersion axis for segment A. Figure 4. Measured distortions for all PSA positions for segment.
EUROPEAN EXTREMELY LARGE TELESCOPE WILL HAVE A 40 METER MIRROR AND WILL GATHER 13 TIMES MORE LIGHT THAT THE BEST CURRENT TELESCOPE – IMAGES WILL BE 16.
DECam Daily Flatfield Calibration DECam calibration workshop, TAMU April 20 th, 2009 Jean-Philippe Rheault, Texas A&M University.
Clicker Questions Chapter 3 Telescopes Copyright © 2010 Pearson Education, Inc.
Freiburg 7/07/20001 laser beam lens CCD (long arm) screen + grid CCD (short arm) glass plates at  45° STAMP : Saclay Telescope for the Alignment of Many.
1. These basics are common to ALL cameras: F-Stop Shutter Speed Film Speed 2.
Sounds of Old Technology IB Assessment Statements Topic 14.2., Data Capture and Digital Imaging Using Charge-Coupled Devices (CCDs) Define capacitance.
The Nature of Light. Light Can Act Like Waves or In 1801 Thomas Young an English scientist did an experiment. –Double slit experiment Passed a beam of.
State of Engineering in Precision Agriculture, Boundaries and Limits for Agronomy.
Observing Transfer Functions For Multimode Spectrometers.
Intelligent Robotics Today: Vision & Time & Space Complexity.
Real-Time Dynamic Shadow Algorithms Evan Closson CSE 528.
XBSM Analysis - Dan Peterson Review of the optics elements: Pinhole (“GAP”), FZP, Coded Aperture Extracting information from the GAP what is the GAP width?
Real-time Parathyroid Visualization System for use in Endocrine Surgery Oral Presentation 4 March 18, 2010 BME 273 Senior Design Group 1 Isaac Pence Advisors:
Presentation on.  There are many methods for measuring of fiber structure. Such as:  The absorption of infrared radiation  Raman scattering of light.
April / 2010 UFOAnalyzerV2 1 UFOAnalyzerV2 (UA2) the key of accuracy UA2 inputs video clip files and outputs meteor trajectories. UA2 does following steps.
Digital Light Sources First introduced in 2001.
Microscope.
Simple Double Beam Spectrometer
UFOAnalyzerV2 (UA2) the key of accuracy
Using a Radio Telescope
Chapter 33 Lenses and Optical Instruments
Aerial Images.
NANO 230 Micro/NanoFabrication
Computer Vision Lecture 4: Color
What Is Spectral Imaging? An Introduction
Detective Quantum Efficiency Preliminary Design Review
Remote sensing in meteorology
Presentation transcript:

Near Field Photonic Crystal Multi- Mode Spectrometer Adam Saltzman 4/19/02 BME 265 Dr. J Izatt Collaborators: Vasily Astratov UNC Chalet, Scott McCain, Michael Sullivan, David Brady Duke University

Multi Mode Spectrometer What are they and why are they superior A multi mode Spectrometer is a spectrometer that can detect the average spectrum of many incoming modes of light. A traditional spectrometer the ocean optics USB 2000 Note two things first this product is small compact and Easily interfaced. To compete in this market you need to push past such well established standards Second its input is a 50 Micron fiber. This fiber aperture Defines the resolution of the spectrometer. In this Spectrometer light comes threw the small input aperture And is splayed across a CCD using a grating. The wider The input light means the more overlap from different sections of the grating. In short this means that the Only light it can analyze is light coupled into this fiber.

Multi Mode Spectrometer This Spectrometer design is simple requiring only The size of your smallest CCD for implementation. Implementation requires you to mount a irregular Photonic crystal directly to the front face of the CCD And the difficulty of the spectrometer is all a matrix Inversion problem Note that the input aperture of this spectrometer Is the entire face of a CCD. As long as you can Get a photonic crystal with diverse spectral Properties you can create a spectrometer. The Resolution of your spectrometer is limited by the Resolution of your camera and the quality of your Crystal not by the size of your input aperture

This is a picture of one of our photonic crystals as seen with white light illumination And 5X magnification. The different regions of color are well ordered segments within a larger photonic structure. The entire crystal is formed of silica micro spheres slowly gravity settled in a fluid bath. The interesting domain properties occur when this bath is brought supercriticaly to vapor and the domains collapse in on themselves. The result is the small domains that you see here. What is a Non-uniform Photonic Crystal

Calibration and forming a spectrometer Monochrometer Slit Output on Edges Oriel light Source Electrim camera Condensing Lens Tube to limit stray light This is the calibration step for the monochrometer. The photonic crystal is mounted directly to the face of the CCD, under the cover glass. Pictures are taken while being illuminated with monochromatic light. Note: Because the intensity of the light varies with wavelength and the response of the CCD varies with wavelength Pictures need to be taken before the photonic crystal is mounted in order to subtract off a background.

Spectral Variance of Near Field Electrim and Imaged Cool Snap Setups Variance of photonic crystal, photos taken with imaging lens and the Cool snap camera. The Cool snap is a 16bit cooled camera with high dynamic range. Variance taken using new background technique and Electrim camera. Electrim is a 10 bit uncooled camera with a low dynamic range.

Difficulties With Poor Variance Problems to be Overcome Because of the Poor resolution of the images and the low dynamic range of the camera Much of the relevant data was lost. The Dynamic range problem can be overcome by taking different background and crystal images at different exposure times for different wavelengths. Although this is possible for a successful spectrometer this is unreasonable and time consuming it requires multiple steps to a already complicated calibration process. The resolution issue can only be corrected by using a higher quality CCD. Because of the poor quality of this spectral variance map an inversion is not possible, But I have completed the code and formatted it in a fashion that will make inversion of this data take moments I will outline the inversion process and give examples of past data from the older system which shows real goals.

Inversion Process Once the calibration photos are taken and a spectral variance map computed its necessary to compute a transfer function for this system. In the simplest mathematical formulation. Input*Transfer=Output We know the output response to each wavelength. So to find the transfer function we multiply the system by the inverse of the input function Input -1 *Input*Transfer=Output*Input -1 Therefore Transfer=Output*Input -1 This is a tensor of values a different value for each of the computed inputs

Inversion Process Continued We know from above that out Input*Transfer=Output and we know are transfer function So are input=Output*Transfer -1 From this simple reconstruction you can reproduce the input signal of any unknown Source. The image to your left is an example of mean centered and Non mean centered reconstructions of a similar photonic crystal in the previous incarnation of this spectrometer. The red line is the actual visible signature of neon and the blue boxes are a 2nm resolution reconstruction. I had hoped for results of at least this caliber with significantly less difficulty.

Advantages of New System The new design for the spectrometer is mobile and complete. It is small compact and set. Previous designs required a imaging system which required a telescoping lens to image the photonic crystal onto the CCD. This old design is sensitive to the slightest motion between camera and crystal. Additional Problems with the old design include focusing on multiple planes within the crystal and extreme sensitivity to stray light

More Advantages This new design by mounting the crystal directly onto the CCD eliminates many of the initial problems. The simplicity of the design requires no lenses or apertures there is never any issue with focusing on the crystal or moving the sample. The crystal functionally becomes part of the CCD. Also because the sample is directly on the plane of the CCD it is difficult for stray light to impinge between the camera and the photonic crystal this makes the system much more robust to environmental conditions

Difficulties Because of the nature of the experiment I was forced to chose a CCD that I could remove the cover plate from and subsequently glue samples to. This required multiple CCD arrays and an accessible camera. Since CCD’s are prohibitively expensive and camera assemblies are not normally accessible this may be as far as this camera can go. Some simple changes that can be made in my procedure is to cut the calibration process into multiple small sections. Keeping track of the background in these small sections will enable me to overcome the dynamic range difficulties of this system. Also perhaps attaching a different thicker photonic crystal will increase the spectral variance of the sample and also allow me to up the integration time stabilizing the image.

Side Notes The pictures taken with the camera show values and are far from the same. The picture on the right is the background subtracted image at 500nm the one on the left is the background subtracted image at 600nm. There is some hope for this that possibly by compensating for the poor dynamic range of this camera I will be able to create a successful inversion