CE MARKING OF IVDDs - the NIBSC perspective Morag Ferguson Division of Virology.

Slides:



Advertisements
Similar presentations
Medical Devices The current legislative and administrative structure.
Advertisements

The regulation of medical devices in Australia. Overview Comparing medicines and medical devices What is a medical device? Statistics on patients requiring.
SALDA In Vitro Diagnostics in South Africa Welcome 5 November 2014 Portfolio Committee Bill
IVD and Point of care testing
Accreditation 1. Purpose of the Module - To create knowledge and understanding on accreditation system - To build capacity of National Governments/ focal.
Yi-Chen Yang, Drug Biology Division Bureau of Food and Drug Analysis Department of Health, Taiwan Collaborative study for establishment of the first national.
Karen Cristiano Biologicals Unit, CRIVIB Calibration against the WHO Standards of National Reference Preparations for detection of blood viruses by NAT:
Introduction to PPDs Regulatory requirements and rationale.
Twinning Project RO2006/IB/EN/09 1 Saxony-Anhalt State Environmental Protection Agency Wolfgang GarcheBukarest Wolfgang Garche Saxony-Anhalt.
CE Regulation Service PROLAB Tech Rev 1 Machinery Directive Flow Chart A brief guide.
Establish Verification Procedures (Task 11 / Principle 6)
Options for Regulation and the Impact of Regulation on the Marketplace 29 November 2005 Alan Kent
S4: Market Surveillance Physikalisch-Technische Bundesanstalt Session 4: Market surveillance Peter Ulbig, Harry Stolz Belgrade, 31 October.
EMS Auditing Definitions
ISO 9001 Interpretation : Exclusions
D. Keane June Internal Quality Audits (4.14) -ISO Requirements for Internal Audits -The Audit Process -Templates for Meeting Requirements.
ISO 9000 Certification ISO 9001 and ISO
CE Marking for Medical Devices “Basic Steps to Compliance” Ján Petrík, PhD. EVPÚ, a.s. Nová Dubnica Medical Devices Branch Office Bratislava 4/27/06 EVPÚ,
EU Regulatory Environment—2008
Guidelines for Laboratory Testing and Result Reporting for Antibody to Hepatitis C Virus Miriam J. Alter, Ph.D. Division of Viral Hepatitis Centers for.
Good Manufacturing Practices for Blood Establishments
Source: ec.europa.eu/CEmarking CE marking makes Europe’s market yours!
Classification of HLA Devices FDA Introduction & Background Sheryl A. Kochman CBER/OBRR/DBA.
The New EMC Directive 2004/108/EC and the DTI transposition Brian Jones and Peter Howick.
BioLife Plasma Services Experience with HBV NAT Testing
S3: Module D Physikalisch-Technische Bundesanstalt Session 3: Conformity Assessment Module D Peter Ulbig, Harry Stolz Belgrade, 31 October.
Regulatory Update Ellen Leinfuss SVP, Life Sciences.
HIV, HCV, and HBV NAT Controls Formulation, Stability and Performance Mark Manak BBI Diagnostics, Inc. A Division of SeraCare Life Sciences, Inc. SoGAT.
IN THE NAME OF GOD Blood Safety S. AMINI KAFI ABAD CLINICAL AND ANATOMICAL PATHOLOGIST IRANIAN BLOOD TRANSFUSION ORGANIZATION(IBTO) RESEARCH CENTER June.
WHY CONFORMITY ASSESSMENT?. What is conformity assessment?  Conformity assessment is the name given to processes that are used to demonstrate that a.
Overview of existing assessment schemes Rolf Bienert, John Lin.
Approximation of legislation to the internal market acquis An EU funded project managed by European Agency for Reconstruction Directive 89/106/EEC on Construction.
21th VHPB meeting on “Prevention of viral hepatitis in Italy: lessons learnt and the way forward” Catania, 7-8 november 2002 RESIDUAL RISK OF TRANSFUSION-
Phare SL Implementation of Technical Regulations on Company Level Top Management Seminar Expert: Willem Wolf Chamber of Commerce and Industry,
Approval Criteria for Assays for Testing Blood Donors for West Nile Virus Robin Biswas, M.D. CBER, FDA Blood Products Advisory Committee Meeting March.
The concept for a network of national Reference Laboratories for high risk IVDs – Results of the working group meeting 1.
Yi-Chen Yang, Yu-Hsuan Chen, Show-Lan Chiu, Hwei-Fang Cheng Drug Biology Division, Bureau of Food and Drug Analysis Department of Health, Taiwan, ROC National.
ENTERPRISE AND INDUSTRY DIRECTORATE GENERAL European Commission 1 PECAs David Eardley DG Enterprise and Industry European Commission Tel: 032 (2)
1 REPUBLIC OF TURKEY PRIME MINISTRY UNDERSECRETARIAT OF FOREIGN TRADE General Directorate of Standardization for Foreign Trade Presented by Selin ÖZŞAHİN.
Proposed algorithm for approval of human TSE tests in Europe.
E UROPEAN B LOOD D IRECTIVE. D ISCLAIMER I have no official status as a spokesperson for the EU, EC, or Member States I present a personal view of the.
Chapter 18 Regulations Tracking. Regulations US: FDA, almost all devices, almost all drugs European Community: devices so far, CE mark is the goal. –Active.
Update on the P. falciparum Standard & Replacement of the HBV & HCV International Standards Sally Baylis, NIBSC SoGAT XIX.
The New Approach and GPSD. Council Resolution of 7 May 1985 on a new approach to technical harmonization and standards [OJ C136 of June 1985] New Approach.
International Scientific Workshop on the Standardization of Genome Amplification Techniques for the Safety Testing of Blood, Tissues and Organs With Regard.
Air Products Solutions for EN th of November 2014 Air Products Internal Use Only Name of speaker.
UPCOMING CHANGES TO IN-VITRO DIAGNOSTICS (IVDs) AND LABORATORY DEVELOPED TESTS (LDTs) REGULATIONS Moj Eram, PhD November 5, 2015.
Support for the Modernisation of the Mongolian Standardisation system – EuropeAid/134305/C/SER/MN Training on standardisation Support to the Modernisation.
European Commission REGULATORY MODEL OF THE EUROPEAN UNION Norbert ANSELMANN Head of Unit, ENTR G2, Standardisation Directorate.
CE mark issues -- PEI view
Workshop on Accreditation of Bodies Certifying Medical Devices Kiev, November 2014.
Workshop on conformity assessment procedures and certification of medical devices INT MARKT Kyiv, November 2011 In Vitro Diagnostic Directive.
Comparative characteristics of Standards ISO 15189:2012 and EN ISO/IEC 17025:2005 – detalization and peculiarities of accreditation process. Ioannis Sitaras.
CLAUDIA PANAIT TAIEX Expert – European Commission Legal Adviser Ministry of Health, ROMANIA.
Technology Services – National Institute of Standards and Technology Conformity Assessment ANSI-HSSP Workshop Emergency Communications December 2, 2004.
M O N T E N E G R O Negotiating Team for the Accession of Montenegro to the European Union Working Group for Chapter 27 – Environment Bilateral screening:
European Diagnostic Manufacturers Association EQA contribution and industry expectations Dr. Claude GIROUD – Chairman Standardization, Quality & Risk Management.
THE OFFICE FOR REGISTRATION OF MEDICINAL PRODUCTS, MEDICAL DEVICES AND BIOCIDAL PRODUCTS Responsibility in the handling of medical devices.
Harmonised use of accreditation for assessing the competence of various Conformity Assessment Bodies Dr Andreas Steinhorst, EA ERA workshop 13 April 2016,
T Mr.Willy Musinguzi, EAC. .Overview of EAC SQMT Infrastructure How EAC standards are Harmonized and Implemented How EAC Quality Infrastructure relates.
Czech Office for Standards, Metrology and Testing Prague/Czech Republic.
Workshop on conformity assessment procedures and certification of medical devices INT MARKT Kyiv, November 2011 Conformity assessment of medical.
ISO Certification For Laboratory Accreditation ISO Certification For Laboratory Accreditation.
Health and Consumers Health and Consumers Introduction to the new Medical Device Regulations and their impact on medical software DG for Internal Market,
Clusters working group COM/CAMD New Regulations
66 items – 70% of circulated products
The EAC Quality Infrastructure and WTO TBT Agreement.
Proposal for a Regulation on medical devices and Proposal for a Regulation on in vitro diagnostic medical devices Key Provisions and GIRP Assessment.
NEW MDR Regulatory Context. NEW MDR Regulatory Context.
MEDICAL DEVICES CONTROL SYSTEM IN INDONESIA
Presentation transcript:

CE MARKING OF IVDDs - the NIBSC perspective Morag Ferguson Division of Virology

Issues to be considered  The IVD directive  IVDDs  Why NIBSC has CE marked some of its working standards  Process of CE marking

The IVD Directive  This is a European Directive aimed at creating a single market and reducing technical barriers to trade for medical devices.  The IVD directive came into force on 7 June 2000

The IVD Directive - key dates  7 December 2003 End of the transitional period - batches of non-CE products cannot be placed on the market. However, batches that are already in the distribution chain on this date can continue to be supplied to the end user  7 December 2005 Full implementation – all IVDs supplied to the end user must be CE marked

Key Elements of the IVD Directive  Classification of IVDs  Essential requirements  Technical Documentation  Conformity assessment procedures  Written Declaration of Conformity

What is an IVDD? An in vitro diagnostic device is defined as a reagent, product, calibrator, control material, kit or instrument, apparatus or equipment, specimen receptacles that is used in vitro for the examination of specimens for diagnostic purposes. Specimens would include: tissue, blood, fluid. In addition, devices an iVD needs to function as intended are iVDs, including software.

Exclusions  Internationally certified ivDs eg WHO International Standards.  In-house use ie ivDs manufactured and used only within the same health institution and on the premises of their manufacture or used on premises in the immediate vicinity without being transferred to another legal entity.

At NIBSC we considered whether our serology and NAT working standards fall within the IVD Directive Questions we asked in order to decide whether we are producing an IVD or not –  How are the standards used?  Does the inclusion of the working standard affect the outcome of the test on the patient/donor?

Use of NIBSC serology working standards in the UK BTS  Working standards for HBsAg, anti-HCV, anti-HIV 1 +2 and anti-HTLV 1 serve as the UK Working Standards cited in Annex 4, General Specifications for Laboratory Test Procedures, of the Guidelines for the Blood Transfusion Services in the United Kingdom, 6 th Edition 2002 (The ‘Red Book’) and have done so since their establishment in the early to mid 1990s.  If these working standards are not detected, the test run is repeated.

Does the inclusion of the working standard affect the outcome of the test on the patient/donor?  The result of the test on the working standard is not impacting on declaring a donor positive as such samples will go through additional confirmatory testing, but it is validating them as being negative/non-reactive.  We therefore decided that the working standards produced and supplied by NIBSC to the UK BTS are IVDs and in accordance with the IVD Directive have to be CE marked.

NIBSC standards which have already been CE marked  HBsAg working standard and monitor sample  Anti-HCV working standard  Anti-HIV 1 working standard  Anti- HIV 2 working standard

Are the NAT working standards also IVDs? Possible uses of NAT working standards  For research purposes only  By plasma fractionators to standardise assays on plasma pools  By diagnostic or laboratories screening blood donors to validate the sensitivity of their assays

Use of NIBSC HCV NAT working standard by the UK BTS  UK BTS laboratories include a dilution of the NIBSC HCV RNA working standard in every test run  The sensitivity of each test run is validated through the detection of this dilution of the NIBSC working standard  This is in addition to validating their assays on the basis of the results of the kit manufacturer’s controls

Is this different from the use of NAT working standards elsewhere in Europe?  Council of Europe guide to the preparation, use and quality assurance of blood components (10th edition, 2004) and the UK Guidelines for Blood Transfusion (The ‘Red Book’) require  …for the release of blood components, HCV RNA NAT assays should detect a run control of 5000IU/ml HCV RNA per donation ie that in a mini-pool of 100 samples you should detect 50IU/ml.

NAT Working standards which NIBSC is in the process of CE marking  HCV RNA  HIV RNA  HBV DNA - to be considered if use within the next 9-12 months increases  Probably not HAV RNA and B19 DNA which are not used by the UK BTS

Conformity Assessment  There are various routes that manufacturers can take to demonstrate compliance with the Directive  Dependent on class of device – self certification unless devices are in high risk categories (Annex II Lists A and list B)  Combination of quality systems and product evaluation  Essentially if the production and characterisation meets ISO 13485:2003, they meet the directive.

List of devices referred to in Annex II list A Reagents and reagent products, including related calibrators and control materials  for determining blood groups - ABO system, rhesus (C, c, D, E, e) anti-Kell,  for the detection, confirmation and quantification in human specimens of markers of HIV infection (HIV 1 and 2), HTLV I and II, and hepatitis B, C and D

The Directive Requirements For Annex II List A devices  A Notified Body must audit the quality system to determine whether it meets the requirements referred to in the relevant quality assurance annex of the Directive and the design certification  This would include an audit of the full quality assurance system and review of the design dossier  Once the Notified Body has issued a certificate of conformity the CE mark can be affixed on the product

Notified Body  Third party certification body, system registrar, testing agency  Designated to conduct conformity assessments  They are required to meet the requirements of the Directive (audited by competent authorities

Common Technical Specifications (CTSs)  The IVD Directive requires that devices must be designed and manufactured in conformity with the essential requirements.  In order to assist manufacturers meet the essential requirements and ensure consistency of the review process across Member States, article 5 of the Directive proposes that CTSs should be prepared.

Common Technical Specifications cont’d  The Directive states that CTS will be prepared for the devices in List A of Annex II, and where necessary, the devices in List B of Annex II.  At present there are no Common Technical Specifications for quality control materials or calibrants