To the use of the linear energy spectrometer based on track etch detectors in radiotherapy proton beams, correlation with data measured by means of thermoluminescent.

Slides:



Advertisements
Similar presentations
Chapter 4 Radiation Dosimeters
Advertisements

Estimation of TLD dose measurement uncertainties and thresholds at the Radiation Protection Service Du Toit Volschenk SABS.
New results of radiation environment investigation by Liulin-5 experiment in the human phantom aboard the International Space Station.
Short-range, high-LET recoil tracks in CR-39 plastic nuclear track detector E. R. Benton 1, C. E. Johnson 1, J. DeWitt 1, N. Yasuda 2, and E. V. Benton.
Radiation Environment in a Human Phantom aboard the International Space Station during the Minimum of 23-rd Solar Cycle Semkova J. 1, Koleva R. 1, Maltchev.
LCSC - 01 Monte Carlo Simulation of Radiation Transport, for Stereotactic Radio Surgery Per Kjäll Elekta Instrument AB
Energy deposition and neutron background studies for a low energy proton therapy facility Roxana Rata*, Roger Barlow* * International Institute for Accelerator.
Radiation Exposure, Dose and Relative Biological Effectiveness in Medicine Background Image:
Space radiation dosimetry and the fluorescent nuclear track detector Nakahiro Yasuda National Institute of Radiological Sciences.
Tumour Therapy with Particle Beams Claus Grupen University of Siegen, Germany [physics/ ] Phy 224B Chapter 20: Applications of Nuclear Physics 24.
Interactions of charged particles with the patient I.The depth-dose distribution - How the Bragg Peak comes about - (Thomas Bortfeld) II.The lateral dose.
Study of the fragmentation of Carbon ions for medical applications Protons (hadrons in general) especially suitable for deep-sited tumors (brain, neck.
Radiation Dosimetry Dose Calculations D, LET & H can frequently be obtained reliably by calculations: Alpha & low – Energy Beta Emitters Distributed in.
Alexander Brandl ERHS 630 Exposure and Dose Environmental and Radiological Health Sciences.
TRAINING COURSE ON RADIATION DOSIMETRY: Instrumentation 1 – Gas detectors / Part 1 Anthony WAKER, University of Ontario Instutute of Technology Wed. 21/11/2012,
At the position d max of maximum energy loss of radiation, the number of secondary ionizations products peaks which in turn maximizes the dose at that.
BIOLOGICAL EFFICIENCY OF A THERAPEUTIC PROTON BEAM: A STUDY OF HUMAN MELANOMA CELL LINE I. Petrović 1, A. Ristić-Fira 1, D. Todorović 1, L. Korićanac 1,
Photon and Energy Fluence
Radiation therapy is based on the exposure of malign tumor cells to significant but well localized doses of radiation to destroy the tumor cells. The.
Dose Distribution and Scatter Analysis
11. – , Athens 8th European Conference on Medical Physics DOSIMETRY AUDITS IN RADIOTHERAPY IN THE CZECH REPUBLIC Irena Koniarová Daniela Ekendahl.
TWO FIELD BREAST PLAN VS. OPTIMIZED CONFORMAL BREAST PLAN: COMPARISON OF PLAN PARAMETERS Authors: Borko Basarić, Ozren Čudić, Milan Teodorović, Borislava.
Научно-практический центр протонной лучевой терапии и радиохирургии (Москва-Дубна) A SYSTEM FOR MEASUREMENT OF A THERAPEUTIC PROTON BEAM DOSE DISTRIBUTION.
SOI detector Geant4-based studies to characterise the tissue-equivalence of SOI and diamond microdosimeteric detectors, under development at CMRP S. Dowdell,
In vivo dosimetry Eirik Malinen Eva Stabell Bergstrand Dag Rune Olsen.
New results for Radiation Effects on the Human Health Obtained during the COST-724 Action F. Spurný a, Ts. Dachev b, a Nuclear Physics Institute, Czech.
OSL Albedo Neutron Dosimeter
CT physics and instrumentation
Response of the sensors to different doses from tests in Israel Radiotherapy is used as a treatment in around 50% of cancer cases in the UK. Predominantly,
Internal Radiation Dosimetry Lab 9. Radiation Measurement We use different terms depending on whether: 1.The radiation is coming from a radioactive source.
Studies of neutron cross-sections by activation method in Nuclear Physics Institute Řež and in The Svedberg Laboratory Uppsala and experimental determination.
Spatial distribution and high LET component of absorbed dose measured by passive radiation monitors in ISS Russian segment N. Yasuda, H. Kawashima, M.
11/12/2015NASA-JSC and DIAS1 Study of Sensitivity Fading of CR-39 Detectors during Long Time Exposure D. Zhou a, b, D. O’Sullivan c, E. Semones a, N. Zapp.
Araki F. Ikegami T. and Ishidoya T.
Passive detectors (nuclear track detectors) – part 2: Applications for neutrons This research project has been supported by the Marie Curie Initial Training.
USE OF GEANT4 CODE FOR VALIDATION OF RADIOBIOLOGICAL PARAMETERS OBTAINED AFTER PROTON AND CARBON IRRADIATIONS OF MELANOMA CELLS Ivan Petrović 1, Giuseppe.
Studies of Helium proportional counters response on fast neutrons, at NCSR “Demokritos” M. Zamani, M. Manolopoulou, S. Stoulos, M. Fragopoulou School of.
Experimental Studies of Spatial Distributions of Neutrons Produced by Set-ups with Thick Lead Target Irradiated by Relativistic Protons Vladimír Wagner.
Assessment of radiation shielding materials for protection of space crews using CR-39 plastic nuclear track detector J. M. DeWitt 1, E. R. Benton 1, Y.
Introduction The Radiological Physics Center (RPC) anthropomorphic quality assurance (QA) phantom program is one tool the RPC uses to remotely audit institutions.
Geant4 User Workshop, Catania, Italy, 15th October, 2009
The Use of Accelerator Beams for Calibration and Characterization of Solid State Nuclear Track Detectors Eric Benton Department of Physics Oklahoma State.
Thermoluminescent dosimetry at the IFJ Krakow P. Bilski, B. Obryk INSTITUTE OF NUCLEAR PHYSICS (IFJ), KRAKÓW, POLAND RADMON, 15 February 2006.
Neutron production in Pb/U assembly irradiated by deuterons at 1.6 and 2.52 GeV Ondřej Svoboda Nuclear Physics Institute, Academy of Sciences of Czech.
Several Techniques for Improving Neutron-Energy Dependence of PADC Track Detector K. Oda 1, D. Hayano 1, H. Ohguchi 1,2, T. Yamauchi 1, T. Yamamoto 2 1.
ESTRO, Geneva 2003 The importance of nuclear interactions for dose calculations in proton therapy M.Soukup 1, M.Fippel 2, F. Nuesslin 2 1 Department of.
An electron/positron energy monitor based on synchrotron radiation. I.Meshkov, T. Mamedov, E. Syresin, An electron/positron energy monitor based on synchrotron.
TLD POSTAL DOSE QUALITY AUDIT FOR 6MV AND 15MV PHOTON BEAMS IN RADIOTHERAPY CLINICAL PRACTICE Sonja Petkovska 1, Margarita Ginovska 2, Hristina Spasevska.
If information seems to be missing, make any reasonable assumptions. 1.A target has an areal density of 2.3 g/cm 2 and a thickness of 0.8 inch. What is.
Neutron Dosimetry and Spectrometry in Complex Radiation Fields using CR-39 detectors This research project has been supported by the Marie Curie Initial.
Photoneutron Distributions around 18 MV X-ray Radiotherapy Accelerators using Nuclear Track Detectors Fazal-ur-Rehman, H. Al-Ghamdi, M. I. Al-Jarallah.
Interaction of x-ray photons (and gamma ray photons) with matter.
24 th ICNTS Design and test of an albedo personal neutron dosemeter based on PADC detectors R. Bedogni a, A. Esposito a, G. Gualdrini b, R. Mishra c, S.
Koichi MurakamiGeant4 Physics Verification and Validation (17-19/Jul./2006) 1 Results from the recent carbon test beam at HIMAC Koichi Murakami Statoru.
1 RHIC NSRL LINAC Booster AGS Tandems STAR 6:00 o’clock PHENIX 8:00 o’clock 10:00 o’clock Polarized Jet Target 12:00 o’clock RF 4:00 o’clock (AnDY, CeC)
Development of elements of 3D planning program for radiotherapy Graphical editor options  automated enclose of contour  correction of intersections 
Three years of cross-section measurements of (n,xn) threshold reactions at TSL Uppsala and NPI Řež O. Svoboda, A. Krása, A. Kugler, M. Majerle, J. Vrzalová,
Linear Energy Transfer and Relative Biological Effectiveness
Interactions of Charged Particles with Matter
Radiological Protection in Ion Beam Radiotherapy
An-Najah National University New Campus, Nablus, Palestine
EURADOS Working Group 9: Radiation Dosimetry in Radiotherapy
David Sutton or Colin Martin But Borrowed from Jerry Williams
Development and characterization of the Detectorized Phantom for research in the field of spatial fractionated radiation therapy. D. Ramazanov, V. Pugatch,
Chapter 5 - Interactions of Ionizing Radiation
O. Svoboda, A. Krása, A. Kugler, M. Majerle, J. Vrzalová, V. Wagner
  Olivier Van Hoey, Alessio Parisi, Werner Schoonjans, Filip Vanhavere
Hp(10) irradiations for personal dosimetry traceability
Presentation transcript:

To the use of the linear energy spectrometer based on track etch detectors in radiotherapy proton beams, correlation with data measured by means of thermoluminescent detectors F. Spurný, K. Brabcová, I. Jadrníčková Nuclear Physics Institute, Academy of Sciences of the Czech Republic, Na Truhlarce 39/64, Prague,

Table of contents Proton therapy beams at the Dzhelepov Laboratory of Nuclear Problems (DLNP), Joint Institute for Nuclear Research (JINR), Dubna, Russia – history, basic characteristics Basic approach to the dosimetry of beams; importance of secondary particles; Methods used for the dosimetry of the DLNP JINR proton therapy beams Results of some dosimetry studies realised by means of active and passive dosimeters along the range, including Bragg peak area.

Beams available at the phasotron of the Dzhelepov Laboratory of Nuclear Problems - 1 Clinical therapy started at Dubna at 1967, interrupted between 1974 and 1987, reconstructed to phasotron facility (see Table), six-cabin medical facility at the JINR Laboratory of Nuclear Problems was built: Ejected beam has a micro-structure: particle bunches of 10 ns duration follow each other with an interval about 70 ns.

Beams available at the phasotron of the Dzhelepov Laboratory of Nuclear Problems - 2 Four proton medical beams intended for irradiation of surface and deeply lying tumours with broad and narrow proton beams of various energies (between 100 and 660 MeV); A medical pion channel for beam therapy using high-intensity negative pion beams with energies between 30 and 80 MeV; A neutron channel for medical purposes (the average energy of neutrons in the beam is approximately 350 MeV) for irradiation of large radioresistant tumours.

Beams available at the phasotron of the Dzhelepov Laboratory of Nuclear Problems - 3 Up to now, only proton beams are used, the total number of patients treated at the JINR proton beam is about 460 up to end of 2007 year. Typical dose rates used are of the order of several Gy per minute. The main importance has been since 2001 year devoted to the proton three-dimensional conformal radiation therapy and radiosurgery. At 2004 year a new proton beam, with the average energy 225 MeV, has been extracted to treat particularly prostate cancer. The ridge filter system permits to form a depth-dose distribution with Spread-Out-Bragg Peak with the width about 70 – 85 mm of water. Since 3-4 years, mostly head and neck cancers have been treated.

Basic approach to the dosimetry of beams Basic beam dosimetry and monitoring is assured with ionization chamber (participation NPI), silicon and diamond detectors; these dosimetric data were used to develop the technique of 3D conformal proton radiation therapy and its planning. Homogeneity of beams, their profiles and the importance of secondary particles in the proton energy transfer are followed also (participation NPI) by means of thermoluminescent detectors TLD’s and track etch detectors (TED’s) as spectrometers of linear energy transfer (LET)

LET spectrometer based on a PADC track- etch detectors polyallyldiglycolcarbonate (PADC) – C 12 H 18 O 7 (CR-39) –Page 0.5 mm (Page Moulgings Ltd, England), –Tastrak 0.5 mm (Track Analysis Systems Ltd, Bristol) etching in 5 N NaOH at 70 o C for 18 hours automatic optical image analyzer LUCIA G track parameters => determination of the ratio v T /v B (v T – etch rate of damaged material, v B – etch rate of unaffected bulk material) => LET range covered: ~ 10 to 700 keV/µm; 1 – 100 mSv

Calibration LET = f(V) irradiation in heavy charged particle beams at –HIMAC (NIRS Chiba, Japan) in the frame of ICCHIBAN programs – ICCHIBAN 2, 4, 6, and 8; –NASA Space Radiation Laboratory (Brookhaven National Laboratory) in the frame of ICCHIBAN BNL; –Nuclotron of the Laboratory of High Energies, JINR, Dubna particles: 12 C – 84 Kr, LET ~ 7.5 – 600 keV/  m detection thresholds: Page ~ 10 keV/  m, Tastrak ~ 15 keV/  m, i.e. primary protons are not directly registered at the beam entrance

Examples of etched tracks protons – Bragg peakBlind exposure No.3 ICCHIBAN 8 Matrjoshka – 9 months on ISS 16 O (20) and 56 Fe (402 keV/mm)

Microdosimetric distributions of dose in 205 MeV proton beam Remarks: 1.When normalise to entrance dose – relative contribution of high LET particles increases with the depth 2.When normalise to the dose at point – importance of low LET particles increases (Bragg peak – also primary protons)

Dose characteristics D LET = ∫ (dN / dL). L. dL H LET = ∫ (dN / dL). L. Q(L).dL BWED = ∫ (dN / dL). L. r(L).dL RBWE = BWED / D L – value of linear energy transfer dN/dL – number of tracks N in a L interval dL Q(L) – ICRP 60 quality factor r(L) – biological weighting function protocols for D and H calculations errors of doses and dose equivalents – statistical and systematical uncertainties

Thermoluminescent detectors Materials of TLDs Al 2 O 3 :C, detection threshold (DT) for photons: ~1 µSv; Czech alumophosphate TL glasses (Al-P glass), DT for photons: ~ 10 µSv; CaSO 4 :Dy, DT for photons: ~ 1 µSv MCP700, LiF:Mg,Cu,P; DT for photons: ~ 1 µSv Interpretation procedure – calibration performed in 60 Co photon etalon beams in K air ; readings transformed to D tissue Relative response (RR) to other radiations RR defined relatively to the dose absorbed in tissue from studied radiation X and reference radiation  : RR = (TL reading /D tissue ) X /(TL reading /D tissue )  i.e. as the ratio of TL signals after the exposure to the same dose in tissue due to a particle and due to 60 Co photons

Relative response of TLD as a function of LET

Dosimetry in 145 MeV proton beam The detectors were positioned orthogonal to the beam direction; The absorbed doses in tissue D pic were measured with precise ionisation chamber (PIC). To monitor the JINR beam, an ionisation chamber of the clinical dosimeter was used. The residual uncertainty in protons energy caused by protons range straggling ranged as E aver ~ (25  25) MeV for the Bragg peak region. D pic were equal to (180±5) mGy at the beam entrance, at the Bragg peak region the doses were (180±5) mGy for luminescent detectors, (4.25±0.12) mGy for TED.

Results - TLD’s 145 MeV protons The average value is, when uncertainties of individual values are not considered, equal to (184±27) mGy, close to the reference value. Nevertheless, the response MCP materials is clearly higher than for other materials. Bragg peak region Spread of values is large, due to the different dependence of RR on the LET of particle transferring energy. For Al 2 O 3 :C as for MCP the RR decreases with LET faster than for other two materials, therefore for average LET in Bragg region (~ 10 keV/μm) the decrease is sensible. For other two TLD’s RR’s are close to 1.00, their readings are close to the reference one.

Track etch detectors as spectrometers of LET – distributions of D, and H in LET Microdosimetric distributions of H LET, as measured in proton beam with Tastrak PADC LET spectrometer. Microdosimetric distributions of H LET, as measured in proton beam with Page PADC LET spectrometer. Remarks: For 145 MeV protons predominates in the H-distribution particles with LET higher than ~ 60 keV/µm, i.e. secondary particles formed through the nuclear interactions of primary protons. At Bragg peak region, predominate particles with LET below 100 keV/µm, i.e. protons, both secondary ones as well as a part of primary protons with energies below the threshold of PADC Page detector, i.e. ~10 MeV.

Track etch detectors as spectrometers of LET – total dosimetric quantities Remarks: Doses due to higher LET secondary particles represent at the beam entrance, i.e. 145 MeV protons, few % of the dose delivered through inelastic collisions of primary protons. The contribution is naturally more important for Page PADC, with lower LET threshold (~ 10 keV/µm, compared with ~ 15 keV/µm for Tastrak). At Bragg peak region, the contribution of particles with LET higher than the threshold represents tens of %, These tendencies determine also the values of quality factors. At the entrance they are close to values usual for neutrons, at Bragg peak region are for Page PADC much lower. *) Page 1 – above 10 keV/µm; Page 2 – above 15 keV/µm

Dependence of RR as a function of the residual energy in a high energy proton beam Remarks: 1.Negligible corrections needed for in-depth measurements with AlP glass, resp. CaSO 4 :Dy, 2.Ratio of Al 2 O 3 :C to other TLDs readings can give an estimation on LET

CONCLUSIONS TLD’s and TED based LET spectrometers proved their flexibility for the solution of many different dosimetry tasks. The importance of the energy transfer through the secondary higher LET particles has been qualified and quantified in high energy proton beams from the beam entrance up to the Brag beak region

Acknowledgements Some part of studies presented in this contribution has been realised in the frame of ESA DOBIES project. Authors are much obliged to Filip Vanhavere (SCK MOL, Belgium) for the coordination of the project, and to ESA Prodex Office for financial assistance. Their thanks belong also to A.G. Molokanov for the realisation of 145 MeV proton irradiation staffs of HIMAC (NIRS, Chiba), NSRL (BNL), and Nuclotron (JINR, Dubna), and the organizers of the runs: Y. Uchihori, J. Miller, E.R. Benton, A.G. Molokanov, and V.P. Bamblevski † M. Gelev (INRNE BAS Sofia) for the fabrication and delivery of CaSO 4 :Dy TLD materials, and to Their colleagues at NPI AS CR for the help during the detectors treatment and development.