AREAscan™ DS1 Series Measurement & Detection Light Grids
Specifications POWER SUPPLY24V DC ± 20% CONTROLLED HEIGHT100….300mm OPERATING RANGE 150….2100mm RESOLUTION 5…10mm DIMENSIONS 20 x 41 mm OUTPUT Digital: PNP Analog: 0…10V HOUSING Aluminum CONNECTIONS M12
DS1- LD – XX – XXX – JV RESOLUTION HR=HIGH RESOLUTION (5mm) SR=STANDARD RESOLUTION (7mm) CONTROLLED HEIGHT 010=100mm 015=150mm 030=300mm DIGITAL/ANALOG OUTPUT J = PNP-NO V=VOLTAGE Models
Functions The analog output provides the measurement of the object and the digital PNP output switches when one optic beam (or more than one) is interrupted. Analog Output Digital Output 5VON EASY Measurement and detection without setting operations
CONTROL OF THE CORRECT POSITION OF MATERIALS (PLASTIC, METAL, PAPER, etc.) IN PROCESS Application Examples
DETECTION AND COUNTING OF OBJECTS IN RANDOM POSITIONS Application Examples
DS1 vs Sick ELG1
SpecificationsDS1ELG1 Distance [mm] Height [mm] 150…21000… Resolution [mm]5 Response time Analog output Digital output 10 1~2.75ms DS1 vs Sick ELG 1 12ms Dimensions[mm]20 x 4047 x 62
DS1 vs Sick WLG12 *Only one unit with retro-reflective functionality
SpecificationsDS1WLG12 Distance [mm] Height [mm] Resolution [mm]7 Response time Analog output Digital output 9 1ms DS1-LD-SR-010 vs Sick WLG 12 1ms Dimensions[mm]20 x 4047 x 62
DS1 vs Sunx NA1-11 *Only IP62
SpecificationsDS1NA1-11 Distance [mm] Height [mm] Resolution [mm]7 Response time Analog output Digital output ms DS1-SD-SR-010 vs Sunx NA ms Dimensions[mm]20 x 4010 x 30
DS1 vs Sti ValueScan *Big size
SpecificationsDS1PS Distance [mm] Height [mm] …300100…330 Resolution [mm]5 Response time Analog output Digital output 5 2ms DS1 vs Sti PartScan 3.5ms Dimensions[mm]20 x 4043 x 43
DS1 vs Banner LS10
SpecificationsDS1LS10 Distance [mm] Height [mm] Resolution [mm]5 Response time Analog output Digital output 5.6 1ms DS1 vs Banner LS 10 1ms Dimensions[mm]20 x 4140 x 49
Mechanical Mounting Thanks to an ultra-slim profile, the DS1 series is ideal for situations where space saving is a key factor. Mounting with brackets and screws provided with the device Direct mounting using lateral holes
Electrical Connections V DCSync+ 0VSyncRx +24V DC Sync + 0V Sync V DC SyncTx PNP output 0V Analog output +24V DC Analog out 0V PNP output Sync TX RX
Electrical Connections Ground connection (not mandatory) can be obtained using a special screw provided with the device.
Operating Status - Diagnostics Power supply and diagnostics Operating status Power supply and diagnostics Two LEDs in the RX unit and one LED in the TX unit clearly indicate the device operating status and diagnostics. Operating status Power supply and diagnostics Operating status Power supply and diagnostics Operating status Power supply and diagnostics
Diagnostics POWER ON LED blinking quickly means there is an alignment problem or it’s at its maximum operating distance. POWER ON LED blinking slowly means short-circuit of the digital output. The blinking of the POWER ON LEDs signals the diagnostics.