DNT 354 - Control Principle Root Locus Techniques DNT 354 - Control Principle.

Slides:



Advertisements
Similar presentations
Figure 8.1 a. Closed- loop system; b. equivalent transfer function
Advertisements

Chapter 4 Continuous Time Signals Time Response Continuous Time Signals Time Response.
Chapter 10 Stability Analysis and Controller Tuning
Chapter 10: Frequency Response Techniques 1 ©2000, John Wiley & Sons, Inc. Nise/Control Systems Engineering, 3/e Chapter 10 Frequency Response Techniques.
Frequency Response Techniques
Lect.7 Steady State Error Basil Hamed
Chapter 8 Root Locus <<<4.1>>>
Chapter 8 Root Locus and Magnitude-phase Representation
Lect.8 Root Locus Techniques Basil Hamed
A Typical Feedback System
Control System Design Based on Frequency Response Analysis
Frequency Response Methods and Stability
Dr. / Mohamed Ahmed Ebrahim Mohamed Automatic Control By Dr. / Mohamed Ahmed Ebrahim Mohamed Web site:
Out response, Poles, and Zeros
Feedback Control Systems (FCS) Dr. Imtiaz Hussain URL :
Automatic control by meiling CHEN1 Lesson 9 Root locus Automatic control 2. Analysis.
Automatic Control Theory-
1 Chapter 2 We need to write differential equations representing the system or subsystem. Then write the Laplace transform of the system. Then we will.
Automatic Control System
Automatic Control Theory School of Automation NWPU Teaching Group of Automatic Control Theory.
The Root Locus Analysis Eng R. L. Nkumbwa MSc, MBA, BEng, REng. Copperbelt University.
Feedback Control System THE ROOT-LOCUS DESIGN METHOD Dr.-Ing. Erwin Sitompul Chapter 5
Properties of Root Locus Lesson Objectives : After finish this lesson, students will be able to  be aware of the control system problem  be aware of.
ME375 Handouts - Spring 2002 Root Locus Method.
INC 341PT & BP INC341 Frequency Response Method (continue) Lecture 12.
Nise/Control Systems Engineering, 3/e
Chapter 5: Root Locus Nov. 8, Key conditions for Plotting Root Locus Given open-loop transfer function G k (s) Characteristic equation Magnitude.
Modern Control Systems (MCS) Dr. Imtiaz Hussain Assistant Professor URL :
Biomedical Control Systems (BCS) Module Leader: Dr Muhammad Arif muhammadarif Batch: 10 BM Year: 3 rd Term: 2 nd Credit Hours (Theory):
Chapter 10 Frequency Response Techniques Frequency Response Techniques.
Chapter 3 Dynamic Response The Block Diagram Block diagram is a graphical tool to visualize the model of a system and evaluate the mathematical relationships.
INC 341PT & BP INC341 Root Locus (Continue) Lecture 8.
Modern Control System EKT 308 Steady-State and Stability.
Chapter 5: Root Locus Nov , Two Conditions for Plotting Root Locus Given open-loop transfer function G k (s) Characteristic equation Magnitude.
Chapter 6 Root-Locus Analysis 6.1 Introduction - In some systems simple gain adjustment may move the closed- loop poles to desired locations. Then the.
Lecture 18: Root Locus Basics
Lecture 9 Feedback Control Systems President UniversityErwin SitompulFCS 9/1 Dr.-Ing. Erwin Sitompul President University
Root Locus Techniques (Sketching Method) Date: 25 th September 2008 Prepared by: Megat Syahirul Amin bin Megat Ali
Dr. Tamer Samy Gaafar Automatic Control Theory CSE 322 Lec. 11 Root Locus.
1 Time Response. CHAPTER Poles and Zeros and System Response. Figure 3.1: (a) System showing input and output; (b) Pole-zero plot of the system;
Modern Control System EKT 308
Prof. Wahied Gharieb Ali Abdelaal
OBJECTIVE  Determination of root from the characteristic equation by using graphical solution.  Rules on sketching the root locus.  Analysis of closed-loop.
Dr. Tamer Samy Gaafar Lec. 2 Transfer Functions & Block Diagrams.
Control Systems Engineering, Fourth Edition by Norman S. Nise Copyright © 2004 by John Wiley & Sons. All rights reserved. Figure 10.1 The HP 35670A Dynamic.
Shroff S.R. Rotary Institute of Chemical Technology Chemical Engineering Instrumentation and process Control.
Control Systems Lect.3 Steady State Error Basil Hamed.
SKEE 3143 Control Systems Design Chapter 2 – PID Controllers Design
Lecture 11/12 Analysis and design in the time domain using root locus North China Electric Power University Sun Hairong.
3.0 Time Response OBJECTIVE
Lecture 7/8 Analysis in the time domain (II) North China Electric Power University Sun Hairong.
Feedback Control System THE ROOT-LOCUS DESIGN METHOD Dr.-Ing. Erwin Sitompul Chapter 5
Root Locus Techniques DNT Control Principle Date: 18th September 2008
Root Locus Method Assist. Professor. Dr. Mohammed Abdulrazzaq
Automatic Control Theory CSE 322
Youngjune, Han Chapter 4 Time Response Youngjune, Han
Automatic Control Theory CSE 322
Time Response Analysis
UNIT-III STABILITY ANALYSIS.
Root-locus Technique for Control Design
UNIT-II TIME RESPONSE ANALYSIS
Frequency Response Techniques
Frequency Response Techniques
UNIVERSITI MALAYSIA PERLIS SCHOOL OF ELECTRICAL SYSTEM ENGINEERING
Root Locus Techniques CH 8: Islamic University of Gaza
Chapter 4. Time Response I may not have gone where I intended to go, but I think I have ended up where I needed to be. Pusan National University Intelligent.
Root Locus Techniques CH 8: Islamic University of Gaza
CH. 6 Root Locus Chapter6. Root Locus.
Frequency Response Techniques
Time Response, Stability, and
Presentation transcript:

DNT 354 - Control Principle Root Locus Techniques DNT 354 - Control Principle

Contents Introduction The Control System Problem Complex Numbers as Vector Defining Root Locus

Introduction Root locus is a graphical representation of the closed-loop poles as a system parameter is varied. Provides a qualitative description of systems performance. The advantage of this technique is in its ability to provide solution for systems of order higher than two. Also provide a graphical representation of system’s stability. Ranges of stability Ranges of instability Conditions that cause a system to break into oscillation Two concepts that will be reviewed beforehand: Control system problem Complex numbers and representation as vectors

The Control System Problem Poles of open-loop transfer function: Easy to obtain via inspection of the denominator Not affected by changes in system gain Poles of closed-loop transfer function: More difficult to obtain which needs factorization of closed-loop system characteristic polynomial Affected by changes in system gain With KG(s) as the forward transfer function and H(s) as the feedback transfer function, the closed-loop transfer function T(s) are reduced to:

The Control System Problem (a) Closed-loop system (b) Equivalent transfer function

The Control System Problem Letting, Then, If given, Poles of G(s) = -2, 0 Zeros of G(s) = -1 Poles of H(s) = -4 Zeros of H(s) = -3

The Control System Problem It is observed: The zeros of T(s) consist of the zeros of G(s) and the poles of H(s). The poles of T(s) are not immediately known without factoring the denominator and are a function of K. Since the system’s transient response and stability are dependant upon the poles of T(s), root locus enables monitoring of the poles as the parameter K is varied.

Complex Numbers as Vector Any complex number, σ + jω, described in Cartesian coordinates can be graphically represented by a vector. (a) s =  + j (b) F(s) = s + a (c) Alternate representation of F(s) = s + a (d) F(s) = s + 7|s5 + j2

Complex Numbers as Vector It can be concluded that (s + a) is a complex number and can be represented by a vector drawn from the zero of the function to the point s. The complex number can also be represented in polar form with magnitude M and angle θ. Exercise: Plot and convert the following complex number into polar form. s = 3 + j4 s = -3 + j5 s = -2 – j7

Complex Numbers as Vector Assume a function, Each factor in the numerator and denominator is a complex number that can be represented as a vector. The function defines the complex arithmetic to be performed to evaluate F(s) at any point, s. Where, Π : Product m : Number of zeros n : Number of poles

Complex Numbers as Vector Since each complex factor can be thought of as a vector, the magnitude M, of F(s) at any point s is, Where, │(s + zi)│ is magnitude of the vector drawn from the zero of F(s) at –zi to the point s. │(s + pj)│ is magnitude of the vector drawn from the pole of F(s) at –pj to the point s.

Complex Numbers as Vector The angle θ, of F(s) at any point s is, Where, Zero angle is the angle measured from the positive extension of the real axis, of a vector drawn from the zero of F(s) at –zi to point s. Pole angle is the angle measured from the positive extension of the real axis, of a vector drawn from the pole of F(s) at –pj to point s.

Complex Numbers as Vector Example: Find F(s) at the point s = -3 + j4. Vector originating at zero at -1 Vector originating at pole at the origin Vector originating at pole at -2

Complex Numbers as Vector Example: Find F(s) at the point s = -3 + j4. The result for evaluating F(s) at the point -3 + j4

Complex Numbers as Vector Example: Find F(s) at the point s = -7 + j9 using the following ways. Directly substituting the point into F(s). Calculating the result using vectors. Answer:

Defining Root Locus Root locus are used to analyze and design the effect of loop gain upon the system’s transient response and stability. By taking the CameraMan system as an example, the video camera system are designed to automatically follow the subject. The tracking system consists of a dual sensor and a transmitter, where one component is mounted on the camera, and the other worn by the subject. An imbalance between the outputs of the two sensors receiving energy from the transmitted causes the system to rotate the camera to balance out the difference and seek the source of energy.

Defining Root Locus (a) CameraMan® Presenter Camera System automatically follows a subject who wears infrared sensors on their front and back tracking commands and audio are relayed to CameraMan via a radio frequency link from a unit worn by the subject. (b) Block diagram (c) Closed-loop transfer function

Defining Root Locus Pole location as a function of gain for the CameraMan system.

Defining Root Locus (a) Pole plot (b) Root locus

Defining Root Locus It is observed: At K = 0, poles exists at -10 and 0. As K increases, both poles move towards each other and meet at -5. The poles break away into the complex plane as K increases further. One pole moves upward while the other downwards. The individual closed-loop poles plotted are removed and replaced with solid lines. Thus, root locus is a representation of the paths of the closed-loop poles as the gain is varied.

Defining Root Locus With regards to transient response: The poles are real for gains less than 25. Thus, the system is overdamped. At a gain of 25, the poles are real and repeated. Thus, the system is critically damped. As gain increases above 25, the poles are complex conjugate. Thus, the system is underdamped. With regards to the underdamped portion of the root locus The settling time remains the same. Damping ratio diminishes and percent overshoot increases. Damped frequency of oscillation increases. With regards to stability, the system is always stable because the root locus never crosses into the RHP.