International Fire Door Inspector Association Presents New Annual Fire Door Inspections NFPA 80 – 2007, 2010, 2013 Standard for Fire Doors and Other Opening.

Slides:



Advertisements
Similar presentations
Underground Storage Tanks at Duke Duke Medical Center –8 permitted USTs located on medical campus –Range in size from 2,000 gallons to 30,000 gallons Proper.
Advertisements

WAYNE DALTON OF SYRACUSE PRESENTS:
Annual Fire Door Inspection
2009 Edition – NFPA 101 Steve Hornyak, DAHC, CDT, FDAI
MEANS OF EGRESS.
Denver Fire Alarm Test FUNDAMENTAL, POWER SUPPLIES, CIRCUITS, INSPECTIONS, TESTING and MAINTENANCE.
Initiating Devices Manual Fire Alarm Boxes Ionization Smoke Detectors
East Carolina University Compressed Gas Safety Training Program
FIRE DOOR INSPECTIONS NFPA 80 STANDARDS THIS STANDARD REGULATES THE INSTALLATION AND MAINTENANCE OF ASSEMBLIES AND DEVICES USED TO PROTECT OPENINGS IN.
NFPA 96 and Building Code Requirements for Commercial Kitchen Hood Systems Presentation for the Sevier County Fire Code and Building Code Officials Presented.
PHOTO. NO.DATE: 01/20/14 REVISIONS Construction Services 170 Long Lane Middletown, CT WESLEYAN U N I V E R S I T Y P CHURCH STREET OLIN.
“TI” Ohhhh….. (TIO) (No TIO is not a person!) What is it all about?
Postal Responsibility/Contractor responsibility 1.Serial number of fire extinguisher 2.Number found on fire extinguisher and panel 3.Date extinguisher.
FCIA CODE EFFORTS FCIA Spring Conference 2003 By William E. Koffel, P.E. Koffel Associates, Inc.
N.F.P.A. 13R Justin Bohlmann FIR-204.
Emergency Lighting Code Review Presented by Iota Engineering LLC.
Texas Department of Insurance State Fire Marshall’s Office Sixth Report on State University Fire Safety January 2002.
FCIA EFC Maintenance Maintenance of Effective Compartmentation - Scott Rankin, Pyro- Stop, LLC FCIA 2004 Past President - Bill McHugh, FCIA Executive Director.
Electrical Safety.
Decoded 2 – Fire Door Assemblies
Controlling Hazardous Energy
2012 International Fire Code Adopted as the minimum fire safety standard by the State of Wyoming City of Sheridan must adopt the minimum standard to retain.
ESSENTIAL SAFETY MEARURES IN BUILDINGS PRESENTED BY: BRUCE HOWIE.
FALAR Part 3 – Post Construction  Compilation of  Maintenance records of fire protection/life safety equipment  Test records of fire protection/life.
Child Care Fire Safety Program North Carolina Fire Prevention Code 2000 International Fire Code with NC amendments. North Carolina Building Code Council.
Chapter 14: Inspection and Maintenance
Amusement Ride Presentation Designed for Amusement Ride Owners and Operators * Hyperlinks are available throughout the presentation. Click on the blue.
OPERATOR, Tester & INSTALLER Licensing WWQRR, Chapter 17, Part L
Emergency Action Plans
New ANSI Fall Protection Standards
CHAPTER 5 Infrastructure Components PART I. 2 ESGD5125 SEM II 2009/2010 Dr. Samy Abu Naser 2 Learning Objectives: To discuss: The need for SQA procedures.
1 29 CFR THE CONTROL OF HAZARDOUS ENERGY.
Commissioning of Fire Protection and Life Safety Systems Presented by: Charles Kilfoil Bechtel National Waste Treatment Plant Richland WA.
Electrical Safety in Construction. Objectives In this course, we will discuss the following: Common electrical hazards Standards relating to those hazards.
Code Officials and the Code Process.  To design the interior of the building in conjunction with codes, standards and federal regulations required in.
Firestopping – Filling the Gaps Makes a Difference Poole Fire Protection Brian Griffin & Jack Poole, PE 2007 DOE Contractor Fire Protection Workshop Argonne.
Tennessee Department of Health Bureau of Health Licensure and Regulations Division of Health Care Facilities.
Exit Routes and Fire Protection
Fire-Resistant Materials & Assemblies Part 2 Chapter 5.
About the Instructor & Presenter: Paul G. Baillargeon, AHC, FDAI Vice President, Technical Consulting Door Security & Safety Foundation A noted veteran.
Fire Resistance Rated Truss Assemblies Educational Overview.
Sprinkler Loads on Trusses Educational Presentation.
Presented by John Lewandowski and Mike Larabel Inspection, Testing, and Maintenance of Kitchen Hood Systems Michigan Fire Inspectors Society Winter Educational.
The purpose of installing fire fighting equipments is to protect the public, property, and assets in fire emergency. Manufacturers of fire protection.
Steep Slope Roofing Systems. Based on the 2007 C.B.C. Presented by Oscar Davalos.
Laboratory equipment Dr. W. Huisman Cairo, November 21th 2012.
Firefighter Emergency Escape Systems New York State Department of Labor Public Employee Safety and Health (PESH)
Inspection and Quality Assurance Requirements for Metal Plate Connected Wood Trusses Educational Overview.
Fire Alarm Verification CAN/ULC-S561-03
Cooling Tower Audit Nathan Maple City of Marion. Why do we undertake an audit and sampling? Regulation 15 South Australian Public Health (Legionella)
Fire Protection Systems Chapter 9 IBC 9th Edition Amendments
Barrier Management Symposium
Cross Connection Survey Training
Fire Extinguisher Inspections.
Product Compliance Training – Codes Class
INTD 405 Modern Practices in Interior Design DOOR & WINDOW SCHEDULES
Construction Management
Fire Door Inspections Qualified Training
INTD 405 Modern Practices in Interior Design DOOR & WINDOW SCHEDULES
Most frequently cited OSHA standards during FY 2018 inspections
From AS :   Part 4— Commissioning, operation and asset management
General Requirements of NFPA 101
NFPA #1901 Fire Apparatus Standard Report
NFPA #1901 Fire Apparatus Standard Report
Fire Alarm Tech Practice Test # 16 NICET
Lock Out Tag Out.
Code Development & Adoption
National Fire Protection Association Update
Denver Fire Depart. License Fire Alarm Practice Test # 12
Field Labeling/Evaluation of Openings
Presentation transcript:

International Fire Door Inspector Association Presents New Annual Fire Door Inspections NFPA 80 – 2007, 2010, 2013 Standard for Fire Doors and Other Opening Protectives October 2, 2013

Why NFPA 80 is Applicable

International Building Code (IBC) 2009 Chapter 7, Section specifies fire door assemblies shall be installed in accordance with NFPA 80. PERTAINS TO INSTALLATION Fire door and shutter assemblies. Approved fire door and fire shutter assemblies shall be constructed of any material or assembly of component materials that conforms to the test requirements of Sections , , and the fire-protection rating indicated in Table Fire door assemblies and shutters shall be installed in accordance with the provisions of this section and NFPA 80.

International Fire Code (IFC) 2009 Chapter 7, Section specifies fire door assemblies shall be maintained in accordance with NFPA 80. PERTAINS TO MAINTENANCE Fire walls, fire barriers and fire partitions. Required fire walls, fire barriers and fire partitions shall be maintained to prevent the passage of fire. All openings protected with approved doors or fire dampers shall be maintained in accordance with NFPA 80.

NFPA 1 Fire Code 2009 Section specifies fire door assemblies shall be installed and maintained in accordance with NFPA 80. PERTAINS TO INSTALLATION & MAINTENANCE. Section The installation and maintenance of assemblies and devices used to protect openings in walls, floors, and ceilings against the spread of fire and smoke within, into, or out of buildings shall comply with Section 12.4 and NFPA 80, Standard for Fire Doors and Other Opening Protectives.

I-Code State Adoption Status Adoption of 2009 / 2012 IBC, IFC, NFPA 1 36 of 50 States

Inspection Frequency NFPA Fire door assemblies shall be inspected and tested not less than annually and a written record of the inspection shall be signed and kept for inspection by the AHJ. (2007,2010) Periodic inspections and testing shall be performed not less than annually. (2013)

Qualified Person NFPA 80 NFPA , 2013 Qualified Person. A person who, by possession of a recognized degree, certificate, professional standing, or skill, and who, by knowledge, training, and experience, has demonstrated the ability to deal with the subject matter, the work, or project.

Inspection Specifics 2007, 2010 (1) No open holes or breaks exist in surfaces of either the door or frame

Inspection Specifics (2) Glazing, vision light frames, and glazing beads are intact and securely fastened in place, if so equipped

Inspection Specifics (3) The door, frame, hinges, hardware, and noncombustible threshold are secured, aligned, and in working order with no visible signs of damage.

Inspection Specifics (4) No parts are missing or broken.

Inspection Specifics (5) Door clearances at the door edge to the frame, on the pull side of the door, do not exceed clearances listed in and

Inspection Specifics (6) The self-closing device is operational, that is, the active door completely closes when operated from the full open position.

Inspection Specifics (7) If a coordinator is installed, the inactive leaf closes before the active leaf.

Inspection Specifics (8) Latching hardware operates and secures the door when it is in the closed position.

Inspection Specifics (9) Auxiliary hardware items that interfere or prohibit operation are not installed on the door or frame.

Inspection Specifics (10) No field modifications to the door assembly have been performed that void the label.

Inspection Specifics (11) Gasketing and edge seals, where required, are inspected to verify their presence and integrity.

Inspection Specifics 2013 (1) Labels are clearly visible and legible

Inspection Specifics 2013 (12) Meeting edge protection, gasketing and edge seals, where required, are inspected to verify their presence and integrity

Inspection Specifics 2013 (13) Signage affixed to a door meets the requirements listed in 4.1.4

Fire Door Inspectors Inspection Versus Certification Fire door inspectors provide inspection services only Listing agencies provide certification services Fire door inspectors never provide certification labels to re-label fire doors without any fire rating labels

NFPA 80 – 2007 Field Modification In cases where a field modification to a fire door assembly is desired, the laboratory whose label is on the assembly shall be contacted and a description of the modification shall be presented to the laboratory.

NFPA 80 – 2013 Field Modification In cases where a field modification to a fire door or fire door assembly is desired, and is not permitted by through , the laboratory with which the product or component being modified is listed shall be contacted through the manufacturer and a written or graphic description of the modifications shall be presented to the laboratory.

NFPA 80 Listing Agency Field Labels

Personnel Certification Programs Growing trend for these programs Involves preparations and repairs Perfect Raceway Program (Example) Field preparation of 3/8” diameter raceway between the hinge and electrified latch Involves program specific label application Audits conducted by the listing agency

Perfect Raceway Program Program Label

Education and Training Courses International Fire Door Inspector Association (IFDIA) Fire Door Inspector Curriculum Accredited by the International Accreditation Services (IAS) a subsidiary of the ICC Door Hardware Institute (DHI) Fire Door Assembly Inspector Course

Contact Us Website: Phone: (888) Dedicated to the exchange of information on annual fire door inspections required by NFPA 80 FREE online website for AHJ’s, Building Owners and Fire Door Inspectors