ECP Extinguishing Control Panel. Extinguishing Control Panel General overview Technical overview.

Slides:



Advertisements
Similar presentations
Prescient II Extinguishing Control Panels
Advertisements

Nexus 1-8 Loop (XP95) Analogue Addressable Control Panels
SITOP select Automation and Drives SITOP select Electronic Diagnosis Module Fault diagnosis – rapid and reliable.
Applications of PICs Advantages/disadvantages Digital and analogue control Loops, sub-routines, scanning, counting and feedback Interrupts Problems with.
ID to 8 Loop Intelligent Fire Alarm Panel
JED Microprocessors Pty Ltd Presenting the JED T430 low-cost Projector Controllers Nov 22nd, 2009.
MEYRA CAN. MEYRA CAN MEYRA CAN remote module identical remotebox for many wheelchair models   identical remotebox for many wheelchair models mechanically.
Zone Control Air System Why? 1.Provides room by room comfort control. 2.Reduces equipment run time. 3.Eliminates hot/cold rooms. 4.Works with conventional.
GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel.
The Worlds No.1 Bridge Navigation Watch Alarm System Introducing Navgard.
System Capacity MAP 5000 Release 1.2 Feature Overview
In this presentation you will:
Motherboard Further Information Click on the image for details about each component.
Engineer Training Control Unit TJ8300 / TJ8500 Control Unit.
SYMAP-BC SYMAP-BC.
ROTHENBUHLER ENGINEERING
FireClass FC501. What’s FC501 ? An entry level Triple Circuit Single Loop addressable system featuring Intelli-Zone mapping An “out of the box” panel.
GST FIRE ALARM SYSTEM INTERNATIONAL BUSINESS DEPARTMENT , GST BEIJING
Presents The Silver Family An Integrated Approach to Processors, Data Communication and Head End Integration.
VEGA CONTROL PANEL Technical
CheckMeter 2.3 Portable Working Standard Page 1 March 2009.
MUST HAVE SHOULD HAVE COULD HAVE Module # 010. Qi Hardware Objectives Recognize hardware Know how to interface to field equipment Know the 4 different.
Precept Conventional Control Panels
1  Module Type Overview  Construction  Characteristics  Installation principles  Details PD 600-Series.
TE-MPE-EE, 02-Apr CLIQ Power supply design J. Mourao TE-MPE-EE.
All content in this presentation is protected – © 2008 American Power Conversion Corporation Symmetra ® LX – redundant UPS High performance, redundant.
Networking All talk - Selective listen Network up to 15 active nodes + 17 passive nodes Nexus/Discovery panels, network repeaters, R3 19” racks, Alarm.
RP-2000 Series Deluge & Agent Releasing Panels
TE-MPE-EE, 16-Apr CLIQ Power supply design J. Mourao TE-MPE-EE.
Programmable logic control Data Processing Computer System Key Board Light Pen Mouse PLC a Process Control Computer System Motion Sensor Sound Sensor.
The Internal Components of a Personal Computer (PC)
Ch4 Electronic Components Circuit/Schematic Symbols.
FG Wilson Access 4000 Control Panel
Doc. Ver. : V1.10 Feb., R&D Center Union Community Co., Ltd. Doc. Ver. : V1.10 Feb., R&D Center Union Community Co., Ltd. Installation &
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
Single Loop Analogue addressable fire control Panel
Confidential / Property of Danfoss Drives A/S DKDD-SMC 1 Drives Division Danfoss presents - VLT ® 2800 Series.
Input/ Output By Mohit Sehgal. What is Input/Output of a Computer? Connection with Machine Every machine has I/O (Like a function) In computing, input/output,
HP900 (ESP Protocol) Analogue Addressable Control Panels
Current operation (black keys) Descriptions Parameter / protection setting (blue keys) Main points to remember A B C D ? SEPAM UMIs SEPAM UMI OPERATION.
The PAX Lite: PAX quality at a great low price.. PAX Lite Series Indication and Setpoint Control Simple field set-up Perfect the low-cost meter users.
KIDDE FIRE PROTECTION Vega Peer to Peer Networking.
COMPUTER MAIN PART DANILO GARCÍA GONZÁLEZ TÉCNICO EN SISTEMAS.
CB200 Conventional Control Panels
2 December, 2015 New Conventional Fire Control Panel.
Electro Eye-Hye System II
Precept Marine Conventional Control Panels
CB200 e Cabinet Extinguishant Control Panels Designed for cabinet extinguishant systems 2 zone extinguishant co-incidence operation Selectable discharge.
Digital Temperature Switches The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
Xplorer 1-2 Loop Analogue Addressable Control Panels From 1-2 loops EN54 2 & 4 Compliance Fully compatible with all Apollo XP95 and Xplorer devices Extensive.
POR:NATALIA RESTREPO BUSTAMANTE. hardware refers to all physical parts of a computer system; its components are: electrical, electronic, electromechanical.
PLC-XD2600 SANYO Sales & Marketing Europe GmbH. Copyright© SANYO Electric Co., Ltd. All Rights Reserved Technical Specifications Model: PLC-XD2600.
CUE – Make Any Pump an E-Pump
CheckMeter 2.1 Portable Working Standard Page 1 March 2009.
PLC-WK2500 SANYO Sales & Marketing Europe GmbH. 2 Copyright© SANYO Electric Co., Ltd. All Rights Reserved 2010 Technical Specifications Model: PLC-WK2500.
Puissant Panel User Training Esc.. 09:11:35 ACTIVE # * 3 6 RESET SYSTEM CLEAR DISPLAY TEST DISPLAY SILENCE BUZZER ESCAPE ENTER SILENCE.
Alarm units AL 175 NT and Aeon Gold For small, medium and large power range.
ACT20X Ex isolator/ amplifier. Page 2 ACT20X (Ex isolators family) Overview - Connects to process equipment in Class/Div, or Zone 0 - Zone 2 areas - ACT20X.
Emergency Voice Communication System ‘beyond expectations’
GmbH Specialist hotel application ComplianceCommercial refrigeration Industrial refrigeration Light Industrial Gas Detection MGS-550 Product Portfolio.
Advantech IPC-6608BP Desktop/ Wall mount Chassis -1 ISA, 4/ 6 PCI, 1 PCIMG, 1 PCI/ISA slot -Advantech PCA-6194VG Core 2 Duo SBC Board -Intel Core2 Duo.
LED1 LED2 LED8 LED9 LED7 LED6 LED5 LED4 CON1 CON4 CON2 CON3 CON5 CON6 A00380 Control Board LED10 JP12 JP10 JP11 LED11 LED12 LED13 LED14 A00380 LED’S.
Avaya VA Line-interactive UPS
ABB i-bus® KNX Valve Drive Actuator VAA/A
Fujitsu Training Documentation Hardware Installation
AN INTRODUCTION TO THE BE9000-DP DUAL DROP & INSERT OPTION FOR
HVI HIPOT TEST SET Pft sERIES.
Copier Jam Detector Design Problem
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
6. USING THE TDR200 IN ANALOGUE MODE
Presentation transcript:

ECP Extinguishing Control Panel

Extinguishing Control Panel General overview Technical overview

Extinguishing Control Panel

Applications Computer Suites Communication Centres Telecom Shelters Archives Document Stores

Extinguishing Control Panel Designed to EN54: 2 & 4 for detection and alarm Designed to BS7273: Pt1 for extinguishing control Designed, manufactured and tested to ISO9001 Over 25 years experience in extinguishing control EMC and LV compliance

Extinguishing Control Panel Fixed format 2 +1, & Self contained with integral PSU Fully programmable from the membrane fascia Slider text inserts for translations All critical I/O circuits are monitored Clear precise information via LED indications Flush mounting bezel available

Extinguishing Control Panel Membrane Fascia Three main areas Panel status LED’s section Extinguishing control & indications section(s) Panel function controls section

Extinguishing Control Panel Membrane Fascia Panel Status LED Indications

Extinguishing Control Panel Membrane Fascia Extinguishing Control LED Indications Area #1

Extinguishing Control Panel Membrane Fascia Extinguishing Control LED Indications Area #1

Extinguishing Control Panel Membrane Fascia Extinguishing Control LED Indications Area #2

Extinguishing Control Panel Membrane Fascia Extinguishing Control LED Indications Area #2

Extinguishing Control Panel Membrane Fascia Control Panel Functions

Extinguishing Control Panel Membrane Fascia Control Panel Functions

Extinguishing Control Panel Membrane Fascia Controls - Extinguishing Areas

Extinguishing Control Panel Monitored Input Circuits

Extinguishing Control Panel Monitored Input Circuits

Extinguishing Control Panel Monitored Output Circuits

Extinguishing Control Panel Monitored Outputs

Extinguishing Control Panel Access Levels Reference EN54:2 restrictions Level 1 - Front Fascia Level 2 - Via a programmable 4 digit pass code providing limited controls

Extinguishing Control Panel Access Levels Level 3 - Via a fixed 4 digit pass code providing additional controls Level 4 - Via a camlock enabling access inside the control panel & programming switch

Extinguishing Control Panel Programming Options

Extinguishing Control Panel How to program Access level 4 (inside control panel) operate switch 1 leaf 2 to the on position Panel enabled LED will pulse rapidly Select required menu option 01, 02, 03, etc.

Extinguishing Control Panel How to program Programming details as per the manual Confirm selection by “Programme” button Return switch 1, leaf 2 to the off position

Extinguishing Control Panel Programming Options Co-incidence Detection -02 (4+1 Version Only)

Extinguishing Control Panel Programming Options Fault Inhibit Release -06

Extinguishing Control Panel Compatibility Detection devices - KFP conventional devices Manual release units KFP devices Alarm devices - bells, electronic sounders, beacons of KFP manufacture KFP manufactured extinguishing equipment

Peripheral equipment Status indicators Hold switches Abort switches Extinguishing Control Panel

Status indicators -SI-1 LED indications only -SI-2LED indications & manual release unit -SI-3LED indications, manual release unit & auto/manual key switch Extinguishing Control Panel

*(1) SI-2 or 3 only *(2) SI-3 only Peripheral equipment (cont’d) Extinguishing Control Panel

Peripheral equipment Status indicators -6 status indicators up to 1.2km away from the ECP -Flush mounted or surface mounted options -RS 485 communications over 2 core cable -Selectable for area A or area B coverage -Lamp test facility -Surface mounted version 123mm (w) x 123mm (h) x 64mm (d) -Flush mounted version 143mm (w) x 143mm (h) Extinguishing Control Panel

Hold Switch -Red mushroom button, non-latching -IP 56 enclosure -108mm (w) x 108mm (h) x 85mm (d) -Out of sequence monitoring by the ECP

Extinguishing Control Panel Abort Switch -Red mushroom button, twist to release -IP 56 enclosure -108mm (w) x 108mm (h) x 85mm (d) -Out of sequence monitoring by the ECP

Technical Summary Quiescent current ECP 2+177mA ECP 4+184mA ECP 4+293mA Battery Calculations Quiescent current x battery degradation factor x 24 hours + half hour alarm time x alarm load x battery degradation factor Q1 x 1.25 x x Al x 1.25 Extinguishing Control Panel

Technical Summary ECP 2+1 Example 0.077mA x 1.25 x x 1.0 x A/H Note: 7 A/H battery space available

Extinguishing Control Panel Technical Summary ECP 4+1 Example 0.084mA x 1.25 x x 1.0 x A/H Note: 7 A/H battery space available

Extinguishing Control Panel Technical Summary ECP 4+2 Example 0.093mA x 1.25 x x 1.0 x A/H Note: 7 A/H battery space available

Extinguishing Control Panel Technical Summary End of line resistors Sounder circuits10K Detection zones3K9 Dimensions ECP (w) x 128 (d) x 398 (h) ECP (w) x 128 (d) x 398 (h) ECP (w) x 128 (d) x 398 (h) Weight ECP 2+1, ECP 4+1 & ECP4+27.2Kg

Extinguishing Control Panel Fuse Details Note: Sub minature fuses are of the plug in type which have a 5mm pitch and are the F type (quick blow). The leads of the fuses will need to be cut down prior to being mounted in their sockets.

Extinguishing Control Panel Internal Controls

Extinguishing Control Panel Internal Indications             

Extinguishing Control Panel Status Indicators SW1 - Momentary push button for micro-processor reset SW2 - Momentary push button for LED test

Extinguishing Control Panel The status indicators have a terminating resistor network for the RS485 communications, the jumper selection must be as detailed below. The ECP RS485 driver card for the status indicators has two way DIL switch SW1 located on the board. With leaves 1 & 2 in the ON position the board will drive in both directions. With leaves 1 & 2 in the OFF position the board will drive in one direction only. Status Indicators

Extinguishing Control Panel Flush mounting bezel