TOX-SPOT Rapid Detection Of Water Toxicity On-Site Test Protocol - Step By Step Version 2.0.

Slides:



Advertisements
Similar presentations
Selling Inoculants Module One – How are your Cows?
Advertisements

Endothelial Progenitor Cell (EPC) Core Laboratory Instructions Version 5.0 March 29, 2008 For questions regarding collection, processing, storage, or shipping.
Rapid determination of Biochemical Oxygen Demand (BOD)
Portable Contamination Biomonitors PCB-TOX & PCB-TOX-SPOT
S&S 12.1 Soil Nutrients and Fertilizers GLEs , 3.1.3,
N ew S nap TM B eta- L actam. Areas neat, clean, orderly, well ventilated, and temperature controlled (4 – 30 0 C or 39.2 – 86 0 F) Adequate lighting.
Carry out PCR for 20, 25 and 30 cycles. Analyse the PCR fragments by agarose gel electrophoresis. Find out how the number of cycles affects the amount.
National Centre for Biotechnology Education The Lambda protocol Copyright © Dean Madden, 2012.
Using the SASS 3010 Particle Extractor
Lab #5 Photosynthesis S61 Procedures:
SURVEY OF CHEMISTRY LABORATORY I SPECTROPHOTOMETRIC DETERMINATION
Laboratory: Unit 3: isolate bacteria (pages 43-52) Unit 4: extract DNA (pages 71-83) Next Day: examine plates & streak Lecture: DNA extraction from bacterial.
Salk Institute Mobile Lab Gel Electrophoresis Teacher Instructions Edvotek Set Up 12 groups.
Practical Clinical Hematology. Introduction HBA 2 is a protein which in humans is encoded by the HBA 2 gene. Hemoglobin A 2 is a normal variant of hemoglobin.
Procedure for QuickTox™ Kit for Aflatoxin Bulk Grain
Module 9: Performing HIV Rapid Tests Demonstration and Practice.
Using the Rapid Test Kit Slide Set 3. Quickvue Rapid Influenza A and B Test Allows for rapid, qualitative detection of influenza type A and type B antigens.
An Introduction to Microvolumetrics and Pipetting
Salk Institute Mobile Lab Gel Electrophoresis Teacher Instructions VWR Set Up 12 groups Mira Costa kit.
Module 3 - Photosynthesis
ORYX Microbatch Screening Ran Meged -1-. Microbatch oil protein & reagent solution -2-
1 USDOC41 Rev 0 1/04 Training and Education Program ©2004 HemoCue, Inc. HemoCue ® Training and Education Program The HemoCue Hb System.
Presented by: Robert O'Brien Training Specialist – Forensic Biology
Preparation of Ribavirin solution for Nebulisation: 6g in 100ml The following guidelines for the safe reconstitution (in the patients room) of ribavirin.
Orion QuikRead ® Portable CRP Test Kit. Supplies QuikRead ® 101 instrument Magnetic calibrator card Blood Capillary tubes with plungers (20 uL) Cuvettes.
Laboratory Techniques I: Dilution Go to browse and set to full screen.
PARA-R Restriction Digest: An Introduction to Plasmids and Restriction Enzymes Laboratory 2a.
Bio-Rad Science Ambassador Program Your profession is your passion. Pass it on. bio-rad.com/scienceambassadors.
DNA Extraction Genes in a Bottle Kit Onion DNA Extraction Genetically Modified Organisms (GMO)
DNA Extraction Amber Baranowski
Unknown Foods: Macromolecule Lab Chapter 2: Carbohydrates, Lipids, and Proteins.
Baby’s formula Prepared by Miss. Sara. Out line  How to clean feeding bottle  How to Prepare a bottle feed using baby milk powder.
Salk Institute Mobile Lab Gel Electrophoresis Teacher Instructions BioRad Set Up 8 groups Grossmont Kit.
Genes in a Bottle. Protocol Highlights What can you teach with the DNA Extraction Kit ? Reinforce the structures of a cell Introduce procedures involved.
ALGALTOXKIT F Test procedure. 1 PREPARATION OF ALGAL CULTURING MEDIUM - VOLUMETRIC FLASK (1 liter) - VIALS WITH NUTRIENT STOCK SOLUTIONS A (2 vials),
DNA-Fingerprint1 Detection of PCR Products by Agarose Gel Electrophoresis.
National Centre for Biotechnology Education The PCR and Plant evolution Copyright © Dean Madden, 2012.
Experimental Procedure Lab 402. Overview Three different experiments are complete in a calorimeter. Each experiment requires careful mass, volume, and.
4.3 (a) To investigate the effect of pH on amylase activity
Chemical Energy Conversions Vanderbilt Student Volunteers for Science Spring 2015.
Comparative Proteomics Kit I: Protein Profiler Module
DAPHTOXKIT F MAGNA Test procedure. PREPARATION OF STANDARD FRESHWATER - VOLUMETRIC FLASK (2 liter) - VIALS WITH SOLUTIONS OF CONCENTRATED SALTS - DISTILLED.
Measure 25 ml of red water and pour it into test tube A. Step 1 Remember 25 is 5 lines above the 20.
Biology Ms. Haut. 1. Add 1 ml (10 drops) of Benedict’s solution to the test tube. 2. Add 8 drops of sample solution to a test tube. 3. Heat the mixture.
September 7, 2007 Warm-Up question What does making cheese have to do with biotechnology?
High Sucrose Soybean Thin-Layer Chromatography (TLC)
Lesson 9 How can you measure radon in water? Slide 9-1 Radon in water Tap water from underground source may be a concern Test water to determine radon.
Cell Culture Techniques
DIGESTING LACTOSE WITH LACTASE Lab Conclusions. Background Information.
Antibody Array Assay Report 1. Protocol 2 Protein Extraction 1.Wash the cells with ice cold 1X PBS. 2.Add Lysis Beads and Extraction Buffer to the sample.
DNA Isolation Lab.
Lab Instructions. Materials and Equipment Distilled Water Zinc metal Filter Paper Plastic Wash Bottle Copper II sulfate Tap water Pencil (not a pen) Plastic.
Experimental Procedure
Systems: Open and Closed Open System: –A system in which both matter and energy can be exchanged with its surroundings Closed System: –A system in which.
DNA Fingerprinting Agarose Gel Electrophoresis Student Instructions
Introduction to Titration Go to browse and set to full screen.
Recombinant DNA Bacterial Transformation Student Instructions Making Competent Cells.
Is your drinking water safe? Drinking Water Hometest Series Please check with “Drinking Water Hometest Series” Drinking Water Hometest suggest simple and.
PLASMID ISOLATION AND ANALYSIS Part III Plasmid Isolation.
An Introduction to Microvolumetrics and Pipetting
Test Kit Training Phosphate.
What do we need to digest our food?
Marine Biotechnology Lab
Bacterial Transformation Visual Guide
Protein Production Jackpot!
Introduction to Titration
The Effect of Temperature on Water Quality
The Effect of Temperature on Water Quality
Presentation transcript:

TOX-SPOT Rapid Detection Of Water Toxicity On-Site Test Protocol - Step By Step Version 2.0

TOX-SPOT Kits Content Refill Kit Reagents: 1. freeze dried bacteria vials 2. freeze dried buffers vials: Negative Control (Pro-Metal; Pro-Organic) Positive Control (Pro-Metal; Pro-Organic) Sample 1 (Pro-Metal; Pro-Organic) Sample 2 (Pro-metal; Pro-Organic) 3. Hydration Buffer 4. Empty test tubes Accessories: 5. Portable luminometer 6. Pipettor (0.1-1ml) 7. Tips 8. Timer 9. Portable incubator 10. Carrying case

Step 1- Preparations Turn portable incubator on by connecting to cigarette plug in the car. Place 8 black-capped plastic tubes inside incubator

Step 1- Preparations (cont.) In the designated foam slots, place 8 freeze-dried vials marked as follows: M-NC,M-PC,M-S1,M-S1 O-NC,O-PC,O-S1,O-S2 Collect samples from suspected water source (river, lake, drinking water tap, etc.).

Step 2 - Hydrate Bacteria & Incubate Place a blue tip on the end of the pipettor and hydrate one vial of freeze-dried bacteria with 0.9ml Hydration Buffer. Place in designated slot in incubator and leave for 10 minutes at 30°C.

Step 3 - Add Clean Water Withdraw from clean water container 0.9ml with pipettor and dispense into each of the control vials: O-NC O-PC M-NC M-PC Mix well the contents of each vial by vigorous flicking with index finger

Step 4 - Add Samples Withdraw from Samples containers 0.9ml with pipettor and dispense into each of the Sample vials: O-S1 O-S2 M-S1 M-S2 Mix well the contents of each vial by vigorous flicking with index finger

Step 5 - Biosensor Addition After exactly 10 minutes of incubation, remove the hydrated bacteria (Biosensor) and mix vigorously with finger. Using the pipettor (set at 100 microliter), rapidly dispense exactly 0.1 ml into each of the 8 vials.

Step 6 - Liquid Transfer Carefully and quickly, pour the content of each vial into its parallel empty plastic tube in the incubator.

Step 7 - Mixing & Incubation Place the black cap back on each plastic tube and mix contents by shaking. Incubate all 8 tubes (holding bacteria, buffer, and water) in the incubator for 15 minutes.

Step 8 - Read Results Using the orange holder, pick up one tube at a time and insert into luminometer in the following order: M-NC M-PC M-S1 M-S2 O-NC O-PC O-S1 O-S2

Step 9- Analyze Data Record the light level obtained in each tube. Use the provided Excel module to automatically analyze the data. NC (Negative Control) is defined as 100% baseline. PC (Positive Control) should be at least 50% of NC. If Samples (S1, S2) reading indicates >50% change in light compared to NC = TOXICITY ALERT Data is stored in the luminometer for future download to PC.

Excel Module - Data Analysis Example