Pulse Sequences Types of Pulse Sequences: Functional Techniques

Slides:



Advertisements
Similar presentations
Pulse Timing parameters & Weighting
Advertisements

Assessment of tumoural ADC’s in rectal Tumours using Burst: New methodological Developments SJ Doran 1, ASK Dzik-Jurasz 2, J Wolber 2, C Domenig 1, MO.
Magnetic Resonance Imaging Lorenz Mitschang Physikalisch-Technische Bundesanstalt, 23 rd February 2009 I. Basic Concepts.
MRI Physics 2: Contrasts and Protocols
Imaging Sequences part I
Chapter 7: Gradient Echo Imaging Methods
Proton Spin In absence of a magnetic field, protons spin at random
Richard Wise FMRI Director +44(0)
M R I Pulse Sequences Jerry Allison Ph.D..
Basis of the BOLD signal
Institute for Biomedical Engineering EXCITE Afternoon Hands-On MRI Sessions: fMRI & DTI.
MR Sequences and Techniques
Statistical Parametric Mapping
Fund BioImag : MRI contrast mechanisms 1.What is the mechanism of T 2 * weighted MRI ? BOLD fMRI 2.How are spin echoes generated ? 3.What are.
Parameters and Trade-offs
Magnetic Resonance Imaging
Fast spin echo 단국대학교 영상의학과 유 동 수.
Principles of NMR Protons are like little magnets
fMRI introduction Michael Firbank
Relaxation Exponential time constants T1 T2 T2*
FMRI: Biological Basis and Experiment Design Lecture 14: Localization I Spin echo BOLD Experiment design 1 light year = 5,913,000,000,000 miles?
Principles of MRI Some terms: – Nuclear Magnetic Resonance (NMR) quantum property of protons energy absorbed when precession frequency.
Perfusion Imaging Lalith Talagala, Ph. D
Psy 8960, Fall ‘06 EPI, Part 2: variants1 Segmentation Partial Fourier Spin echo vs. gradient echo Inversion recovery Long vs. short TE.
Measuring Blood Oxygenation in the Brain. Functional Imaging Functional Imaging must provide a spatial depiction of some process that is at least indirectly.
Magnetic Resonance Imaging 4
Gradient echo pulse sequences
Advanced pulse sequences
Principles of Magnetic Resonance
Imaging Sequences part II
A new method for diffusion imaging using Burst excitation C. Wheeler-Kingshott 1, D. Thomas 2, M. Lythgoe 2, S. Williams 2 and S. J. Doran 1 1 University.
Seminar October, 2008 j. brnjas-kraljević. Imaging (MRI)  tomography technique  tomography technique – the volume image is built up by images of thin.
Functional Spectroscopy of Brain Activation Following a Single light Pulse: Examinations of the Mechanism of the Fast Initial Response. J.Henning,C.Janz,O.Speck,and.
THE CORRELATIONS OF 3D PSEUDO-CONTINUOUS ARTERIAL SPIN LABELING AND DYNAMIC SUSCEPTIBILITY CONTRAST PERFUSION MRI IN BRAIN TUMORS Delgerdalai Khashbat,
Pulse sequences.
Chapter 6 Lecture Spin Echo Imaging Methods Mark D. Herbst, MD, PhD Two Main Types of MR methods –Spin Echo –uses RF pulse to get an echo –Gradient Echo.
Basics of MRI.
RT 4912 Review (A) Rex T. Christensen MHA RT (R) (MR) (CT) (ARRT) CIIP.
Medical Image Analysis Medical Imaging Modalities: Magnetic Resonance Imaging Figures come from the textbook: Medical Image Analysis, Second Edition, by.
Contrast Mechanism and Pulse Sequences Allen W. Song Brain Imaging and Analysis Center Duke University.
DIFFUSION & PERFUSION MRI IMAGING Dr. Mohamed El Safwany, MD.
G Practical MRI 1 Basic pulse sequences.
Contrast Mechanisms in MRI Introduction to Cardiovascular Engineering Michael Jay Schillaci, PhD Managing Director, Physicist Tuesday, September 16 th,
Perfusion MRI in GSK Study
Contrast Mechanism and Pulse Sequences
Statistical Parametric Mapping
MRI Physics Dr Mohamed El Safwany, MD.. MRI Magnetic Resonance Imaging Magnetic Resonance Imaging.
BIOE 220/RAD 220 REVIEW SESSION 6 March 5, What We’ll Cover Today General questions? Spinal cord anatomy review Fat in images T2* vs T2 decay Review.
 fMRI: functional (nuclear) magnetic resonance imaging  Neuroimaging: get the structure of the brain Want to know how it works: connection brain parts.
Magnetic Resonance Imaging
FMRI – Week 4 – Contrast Scott Huettel, Duke University MR Contrast FMRI Graduate Course (NBIO 381, PSY 362) Dr. Scott Huettel, Course Director.
MRI Physics: Pulse Sequences
V.G.Wimalasena Principal School of Radiography
FMRI and MR Spectroscopy. BOLD BOLD=Blood Oxygenation Level Dependant contrast Neurons at work use oxygen (carried by hemoglobin) 1-5 s. delay, peaks.
MRI: Contrast Mechanisms and Pulse Sequences
Spinning Nucleus Produces Magnetic Moment
Principles of MRI Physics and Engineering Allen W. Song Brain Imaging and Analysis Center Duke University.
MRI Magnetic Resonance Imaging. Definition A non-ionizing technique with full three dimensional capabilities, excellent soft-tissue contrast, and high.
Chapter 5 Mark D. Herbst, M.D., Ph.D.. The MR Imaging Process Two major functions –Acquisition of RF signals –Reconstruction of images.
Parameters which can be “optimized” Functional Contrast Image signal to noise Hemodynamic Specificity Image quality (warping, dropout) Speed Resolution.
BOLD functional MRI Magnetic properties of oxyhemoglobin and deoxyhemoglobin L. Pauling and C. Coryell, PNAS USA 22: (1936) BOLD effects in vivo.
FMRI data acquisition.
Go to 51:47-1:06 mark listen for 9 minutes.
MRI Physics in a Nutshell Christian Schwarzbauer
بسم الله الرحمن الرحيم.
Where Mt is the magnetization at time = t, the time after the 90o pulse, Mmax is the maximum magnetization at full recovery. At a time = one T1, the signal.
Magnetic Resonance Imaging: Physical Principles
Magnetic Resonance Imaging
(4)ELECTRONIC SUPPORT SYSTEM
The echo time (TE) The echo time (TE) refers to the time between the application of the radiofrequency excitation pulse and the peak of the signal induced.
Presentation transcript:

Pulse Sequences Types of Pulse Sequences: Functional Techniques Spin Echo Gradient Echo Inversion Recovery Echo Planar Imaging Functional Techniques Diffusion-weighted imaging Perfusion weighted imaging Spectroscopy fMRI

Pulse Sequences Spin Echo (SE) (Conventional Spin Echo) RF pulse sequence with a 90o excitation pulse followed by a 180o rephasing or refocusing pulse to eliminate field inhomogeneity and chemical shift effects. Main Points: 1) 90o excitation pulse 2)180o rephasing pulse

Pulse Sequences Spin Echo (SE)

Pulse Sequences Spin Echo (SE)

Pulse Sequences Spin Echo – Multiple Echo

Pulse Sequences Spin Echo – Multi-echo

Pulse Sequences Spin Echo Pulse Sequence T1 weighted images Short TR (300 ms – 700 ms) Short TE (10 ms – 30 ms) T2 weighted Images Long TE ( > 80 ms) Long TR ( > 2000 ms)

Pulse Sequences T1WI vs. T2WI ____________________________________ *Short TR *Long TE Short TE Long TR T1WI T2WI

Pulse Sequences Proton (Spin) Density Weighted Density of Resonating spins in a given volume (e.g., tissue). The higher the concentration of spin density, the higher (brighter) the received signal. Long TR (1000 ms – 2000 ms) Short TE (10 ms – 30 ms)

Pulse Sequences Spin Echo T1 – weighted image (short TR, short TE) Proton Density image (long TR, short TE) T2 – weighted image (long TE, long TR)

Pulse Sequences Rapid Acquisition with Relaxation Enhancement Also known as RARE Fast Spin Echo (FSE) – GE, Picker, Toshiba & Hitachi Turbo Spin Echo (TSE) – Siemens & Philips One advantage is speed without loss of S/N. In CSE, if acquisition time is reduced by 50%, the S/N is reduced by 40%

Pulse Sequences Fast Spin Echo

Pulse Sequences RARE

Pulse Sequences Fast (Turbo) Spin Echo Echo Train Length (ETL) or Turbo Factor (TF) Effective Echo Time (ETE) Echo Train Spacing (ETS)

Pulse Sequences Rapid Acquisition with Relaxation Enhancement Acquires multiple echoes per excitation at different phase encoding steps – echo train length (ETL) The number of echos acquired per excitation pulse is referred to as echo train length TE is referred to as “Effective TE” (ETE)

Pulse Sequences Rapid Acquisition with Relaxation Enhancement Time between each echo (phase encoding step) is referred to as echo train spacing (ETS) TE is primarily responsible for image contrast. RARE reduces the amount of excitation pulses. Scan Time – (TR x Gpe x NEX) / ETL

Pulse Sequences Fast Spin Echo Scan Time = (TR x Gpe X NEX) / ETL TR = 2000 ms (2000 x 256 x 4) / 8 Gpe = 256 2000 x 256 x 4 = 2048000 NEX = 4 2048000 / 1000 = 2048 seconds ETL = 8 2048 / 60 (convert seconds to minutes) = 34.13 minutes 34.13 minutes / 8ETL = 4.26 minutes

Pulse Sequences Fast Spin Echo Advantage Disadvantage Reduced Scan Time Disadvantage Possible flow and motion artifacts Fat may be brighter on FSE than CSE Image blur – Increased TF or ETL

Pulse Sequences Gradient Echo (GE) Generally uses an excitation flip angle (FA) of less than 90o degree and a gradient reversal to rephase the protons Main Points: 1) Variable Flip Angle (FA) 2) Gradient reversal

Pulse Sequences

Pulse Sequences Gradient Echo

Pulse Sequences Advantages: Gradient Echo Much shorter scan times than SE pulse sequences Low FA allows for faster recovery of longitudinal magnetization Gradients rephase faster than 180o RF pulses TR and TE values are shorter than spin echo pulse sequences

Pulse Sequences Disadvantages: Gradient Echo Susceptible to magnetic field inhomogeneities Contain magnetic susceptibility artifacts T2* weighting

Pulse Sequences Fast Spin Echo (Advantage over GRE) FSE uses a 180 degree pulse to eliminate susceptibility artifacts. Heavy T2 – weighted images cannot be easily acquired with GRE

Pulse Sequences Gradient Echo: Weighting T1 Weighting - 1o controlled by FA and TR T2* Weight – 1o controlled by TE

Pulse Sequences Gradient Echo Pulse Sequence T1 – Weighted Large Flip Angle Short TR Short TE T2* - weighted Small Flip Angle Long TR Long TE Proton Density Weighted

Pulse Sequences Inversion Recovery Sequence consisting of an initial 180o RF pulse to invert the magnetization, followed by a spin-echo (90o to 180o) or gradient sequence.

Pulse Sequences Inversion Recovery

Pulse Sequences Inversion Recovery FLAIR – Nulls CSF STIR – Nulls FAT

Pulse Sequences Dixon

Pulse Sequences Null Point

Pulse Sequences Echo Planar Imaging (EPI) Allows data to be collected and reconstructed in less than a second Stronger and faster gradients (slew rate) required Data collected along GFE (readout) direction

Pulse Sequences Echo Planar Imaging

Functional Techniques Diffusion-weighted image (DWI) Technique used to measure the motion of water molecules Areas with increased diffusion within a tissue show greater signal loss Terms such as – b-value, Apparent diffusion coefficient (ADC) Clinical applications – acute cerebral infarcts (ischemic areas) appear bright

Functional Techniques Perfusion-weighted image (PWI) Technique used to measure the flow of blood though the capillary region of an organ or tissue Dynamic Susceptibility Contrast (DSC) uses gadolinum as a tracer Arterial Spin Labeling (ASL) noninvasive Terms - Cerebral Blood Flow (CBF), Mean transit Time (MTT) and Cerebral Blood Volume (CBV)

Functional Techniques Spectroscopy (MRS) Technique that provides chemical information about a tissue Nuclei such as 1H, 31P, 13C, 23Na, 39K, 19F Methods used: Stimulated echo acquisition mode (STEAM) Point-resolved spectroscopy (PRESS) Image-selected in vivo Spectroscopy (ISIS) Chemical shift imaging (CSI) a.k.a. magnetic resonance spectroscopic imaging (MRSI)

Functional Techniques Functional MRI (fMRI) Term used to describe any technique that evaluates brain physiology rather than anatomy fMRI specifically used to map brain activity Areas of interest – motor cortex, visual cortex Blood oxygenation level-dependent (BOLD)

Functional Magnetic Resonance Imaging fMRI BOLD: Blood Oxygen Level Dependence fMRI is the most common for research purposes Measures the hemodynamic response (amount of blood flow) related to neural activity in the brain Increase in magnetic susceptibility when blood is oxygenated Direct correlation between brain activity and cerebral blood flow has been observed, but unsure of exact underlying mechanisms Usually uses a T2* weighted contrast TR: 2-4s 2-4mm spatial resolution (better with 3-9T)

Methods Two common types of experimental design Resting state: Participant has no task, just lies still in the scanner Experimental: Participants are presented with tasks or stimuli at approximately 5s intervals Or block design due to poor temporal resolution 5s + 5s … to 2 min Repeat w Next Block of Images

Methods- cont’d Although commonly thought of as a direct measure of brain activity, fMRI usually identifies relative differences in brain activity Correlation does NOT equal causality Subtraction Technique EX: Response to images of smoking Smokers Nonsmokers Difference - =

Clinical Utility fMRI is not currently used for diagnostic purposes Used to identify functional maps of neural networks & research relative deficiencies in brain function New software allows for the quantification of network activity via Independent Components Analysis Differences in network connectivity has been associated with certain disorders and fMRI should be capable of accurate diagnosis within the next decade Allows early identification and treatment of disordered individuals (e.g. Schizophrenia and Alzheimers) Visual Network Default Mode Network

Other Functional Techniques Diffusion based fMRI Contrast MR Arterial Spin Labeling Magnetic Resonance Spectroscopic Imaging Electroencephalography Although it has great spatial resolution, fMRI has poor temporal resolution of neuronal activity Combined EEG-fMRI may allow quantification of activity at sub-ms and sub-mm resolution