Gas Chromatography Introduction 1.) Gas Chromatography
Advertisements

Gas Chromatography Lecture 36.
Gas Chromatography Vaporization of sample Gas-solid
Gas Chromatography 427 PHC.
Lecture 8b Gas Chromatography.
GAS CHROMATOGRAPHY ENVE 202 Dr. Aslıhan Kerç.
GAS CHROMATOGRAPHY.
Lab Methods Day June 25, 2014 Gas Chromatography
Mobile phase is a gas! Stationary phase could be anything but a gas
GC & LC.
HPLC 1. Introduction 1.Introduction CHROMATOGRAPHY Chromatography basically involves the separation of mixtures due to differences in the distribution.
1 Gas Chromatography Lecture a. Thermal Conductivity Detector (TCD) This is a nondestructive detector which is used for the separation and collection.
The geometry of capillary columns is fairly simple, consisting of length, internal diameter, and stationary phase thickness. Nevertheless, there are endless.
Gas Chromatography.
Gas Chromatography.
Chapter 27 Gas Chromatography
1 Chapter 24 GC Gas Chromatography. 2 GC Mechanism of separation is primarily volatility. Difference in boiling point, vapor pressure etc. What controls.
Capillary Columns Nicholas H. Snow Department of Chemistry, Seton Hall University, 400 South Orange Avenue, South Orange, NJ 07079
Intro to Chromatographic Separations Chap 26. Originally based on separation and identification by color Originally based on separation and identification.
Gas Chromatography. Mobile phase: Inert gas such as N2 or He. Mobile phase: Inert gas such as N2 or He. Stationary phase: May be solid (GSC) or Stationary.
Gas chromatography is used in many research labs, industrial labs (quality control), forensic (arson and drug analysis, toxicology, etc.), environmental.
Gas Chromatography.
Chromatography Chapter 4.
Gas Liquid Chromatography
Gas Chromatography. Gas Chromatography Basics Gas Liquid Chromatography (GLC) Gas Solid Chromatography (GSC) Mobile phase does not interact with analyte.
Chapter 22 GC & LC Gas Chromatography -1 1.Schematic diagram.
CHAPTER 29 Supercritical Fluid Chromatography The mobile phase is a supercritical fluid (a fluid above its critical T and critical pressure) Supercritical.
Effect of Packing Particle Size on Plate Height. Resolution between 2 adjacent peaks.
Principles of Chromatography. Chromatography is the most powerful tool for separating & measuring the components of a complex mixture. Quantitative &
Chapter 22 GC & LC Gas Chromatography 1.Schematic diagram.
Chapter 6 - Chromatography
Chapter 27 Gas Chromatography 1. Principles
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 22 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
1.1 General description - Sample dissolved in and transported by a mobile phase - Some components in sample interact more strongly with stationary phase.
Chapter 21 Principles of Chromatography. Chromatography is the most powerful tool for separating & measuring the components of a complex mixture. Quantitative.
CHROMATOGRAPHY. The general name given to methods by which two or more compounds in a mixture are physically separated by distributing themselves between.
Separation Science Differences in IMFs can be used to separate chemical substances for further analysis. Differences in IMFs can be used to separate chemical.
PLOT Columns P orous L ayer O pen T ubular Porous layer open tubular (PLOT) columns are defined as capillary columns where the inner surface is coated.
INSTRUMENTAL ANALYSIS CHEM 4811 CHAPTER 12 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
INTRODUCTION TO CHROMATOGRAPY
Gas Chromatography Lecture 38.
Gas Chromatography Experiment. Gas Chromatography - Gas Chromatography (GC) is a common technique used to separate and identify volatile organic compounds.
Intensive General Chemistry Chemical separations II Isabelle Vu Trieu
Analytical Separations
HPLC – High Performance Liquid Chromatography
Basic Gas Chromatography. History Separation of dyes by Runge Separation of plant pigments by Tswett Theoretical gc (Martin & Synge)
1 Gas Chromatography Lecture Liquid Stationary Phases In general, the polarity of the stationary phase should match that of the sample constituents.
Lecture 4a Gas Chromatography.
Ch 21 – Principles of Chromatography and Mass Spectrometry Ch 22 – Gas and Liquid Chromatography.
Chapter 32 Gas Chromatography. In gas chromatography, the components of a vaporized sample are separated by being distributed between a mobile gaseous.
Gas Chromatography b General Design of a Gas Chromatograph b Separation Processes in Gas Chromatography b GC Columns b GC Injectors b GC Detectors.
Gas Chromatography.
Gas Chromatography. In Gas Chromatography (GC), a gaseous mobile phase transports a gaseous solute through a long, thin column containing solid or liquid.
Lecture 9 Gas Chromatography Lecture 9 – Chromatography, Dr. Rasha Hanafi 1© Dr. Rasha Hanafi, GUC.
Experiments in Analytical Chemistry
1.1 General description - Sample dissolved in and transported by a mobile phase - Some components in sample interact more strongly with stationary phase.
Gas Chromatography Chap 27 Types: Gas-solid chromatography (GSC)
Reading assignment: section 26E(p781) Chapter 26 # 2, 3, 14, 15, 16 Chapter 27 # 7(a,d,f), 22, 23, 24, 25.
Chem. 133 – 5/9 Lecture.
GAS CHROMATOGRAPH. GAS CHROMATOGRAPH Principle: Which type of compounds can analyse? Volatile Thermostable.
Chem. 133 – 5/11 Lecture.
Chem. 231 – 2/25 Lecture.
Chapter 27 Gas Chromatography
Gas Chromatography.
An Introduction to Chromatographic Separations
BASICS OF SUPERCRITICAL FLUID CHROMATOGRAPHY
VAPOUR PHASE CHROMATOGRAPHY
Gas Chromatography.
GAS CHROMATOGRAPHY.
Chromatography Various techniques for the separation of complex mixtures that rely on the differential affinities of substances for a gas or liquid mobile.
Presentation transcript:

animation.php

Major Components

Column Stationary Phases: Packed - liquid coated silica particles (< mm diameter) in glass tube -best for large scale but slow and inefficient Capillary/Open Tubular - wall-coated (WCOT) <1 mm thick liquid coating on inside of silica tube - support-coated (SCOT) 30 mm thick coating of liquid-coated support on inside of silica tube - best for speed and efficiency but only small samples diameter mm

Why are modern GC based on a capillary column? Back to the van Deemter Eqn. H = A + B/ + C Remember,  = flow rate, A = multiple paths, B/ = longitudinal diffusion effects, C = MT effects We want to minimize H as much as possible.

Many based on polysiloxanes or polyethylene glycol (PEG):

Non-polar stationary phases best for non-polar analytes non- polar analytes retained preferentially Polar stationary phases best for polar analytes polar analytes retained preferentially

Temperature Programming -As column temperature raised, vapor pressure analyte increases, eluted faster - Raise column temperature during separation – temperature programming – separates species with wide range of polarities or vapor pressures

Sample Injection

GC Injection Syringe It is important to rapidly vaporize the sample. Slow vaporization increases band broadening, by increasing the sample “plug”. Injection port temperature is usually held 50 o C higher than the BP of the least volatile compounds. GC injection and band broadening and anomalies. Extremely slow injections will cause band- broadening, wide sample “plug”. Jerky injections may cause double peaks for the same analyte species.

Split vs. Splitless Injection Sample injection is done by a syringe – 1 to 5 μL or ng’s of analyte for the average capillary column. Capillary columns usually require split in injections, a sample reduction method. Depending on the spilt ratio (adjustable) only 0.2 to 2 % of the sample injection makes its way to the column. The rest is discarded. SplitSplitless

GC Detectors -Ideal detector characteristics, for flowing systems (e.g. GC) -large dynamic/linear range -response independent of flow rate, i.e. fast response times -Universal detection, responds to all species. -Keep this in mind when we discuss HPLC and CE. -Additional requirements for GC -operation from RT to 400 o C - detector response independent of detector oven T

Flame Ionization Detector (FID). -Sensitive towards organics -Analyte is burned in H 2 /air, which produces CH and CHO +, radicals, remember our discussion regarding the blue cone in AA. -CHO + radicals are reduced at a cathode which produces a current proportional to the radical quantity. About amps -Specific for organic carbon, insensitive to inorganics, CO 2, SO 2 etc. - Response to specific organic depends on the number of organic carbons.

Electron Capture Detector (ECD) Sensitive to electron withdrawing groups especially towards organics containing –F, -Cl, -Br, -I also, -CN, NO 2 Nickel-63 source emits energetic electrons collides with N 2 (introduced as make-up gas or can be used as carrier gas) producing more electrons: Ni-63  e - + N 2  2e - + N 2 + The result is a constant current that is detected by the electron collector (anode).

GC-MS offers structural determinations With other detectors identification is possible with retention times of analyte and standard, however it’s best if another method is used as a confirmation.