Arc Fault Circuit Interrupters. Residential fires caused by electricity occur more than 40,000 times each year in the U.S. alone. 40% are due to arcing.

Slides:



Advertisements
Similar presentations
S A F E FAMILY Electrical Safety Keeping your home hazard-free.
Advertisements

Introducing Electricity and Electrical Safety
Introducing Electricity and Electrical Safety
Electrical Safety.
Electrical Installation
Electrical Fire Safety Fire Prevention Week 2012 Electrical Safety Foundation International.
4/30/2015 AFCI 9/01/07 Rev 5 1 Arc Fault Circuit Interrupters For NEMA Field Reps.
Electrical Safety and Grounding Essentials Copyright © Texas Education Agency, All rights reserved.
Technician License Course Chapter 9 Lesson Module 20: Electrical Safety.
EET Survey of Electronics
EET Survey of Electronics Chapter 24 - Residential Branch Circuit Wiring.
Electricity Principles & Applications Sixth Edition ©2003 Glencoe/McGraw-Hill Richard J. Fowler Chapter 16 Residential Wiring Concepts.
13.3 Alternating Current (AC) Electromagnetic induction requires a changing magnetic field to produce an electric current. If you were to push a permanent.
Electrical Power Systems
©2008 The McGraw-Hill Companies, Inc. All rights reserved. Electronics Principles & Applications Seventh Edition Arc Fault Circuit Interrupters Charles.
Electrical Fundamentals
The Home Inspection Book: A Guide for Professionals By Marcia Darvin Spada Copyright, Thomson/South-Western, 2003, Revised, 2006.
By Carlin Bright. Electricity The flow of electrons in a conductor.
Area of Study 2: Electricity
Electrical Safety INSTRUCTOR’S NOTES:
Hazard Identification at Home. Ground Fault Circuit Interrupters (GFCI’s)  GFCI’s provide protection by turning off the power before a shock occurs 
Electrical Safety INSTRUCTOR’S NOTES:
1 Electrical Safety. 2 Electrical Hazards & OSHA 29 CFR (b)(1) requires: “Electrical equipment shall be free from recognized hazards that are.
Chapter 17.3 – Circuits electric circuit – a set of electrical components connected such that they provide one or more complete paths for the movement.
7.1.3 Student Book © 2005 Propane Education & Research CouncilPage Applying a Systems Approach to Gas Appliance Troubleshooting Troubleshooting.
Applied Circuit Analysis Chapter 3 - Power and Energy Copyright © 2013 The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
Electrical Safety in Construction. Objectives In this course, we will discuss the following: Common electrical hazards Standards relating to those hazards.
Mechatronics – EAS5407 Spring 2003 Kyle I. Platt Class Discussion 2.11.
Fire Safety Month Fire Safety Tips for October Department of Risk Management James Madison University.
Electric Circuits Series and Parallel Circuits. Circuit Diagrams An electric circuit is a complete path through which charge can flow Circuit diagrams.
35 Electric Circuits In a parallel circuit, each device operates independent of the other devices. A break in any one path does not interrupt the flow.
Objectives Review conductor and conduit selection Learn about protection systems (basic rules) Learn to design Residential Electrical Systems.
13.3 Alternating Current. Alternating Current An electric current that periodically changes direction Current induction in a coil reverses direction periodically.
Home Electrical Systems. Behavior Objectives  Define the basics of Electrical Systems  Explain the basic principles of Electricity.  Describe the different.
1 comes from the electrons in an atom when they are transfered them between objects. + + electrons have a negative (-) charge.
Electrical Safety in the Home 1.Circuit Breakers 2.Fuses 3.Wall Outlets 4.Circuit Breakers 5.GFCI/RCD.
By: Mr. Brock.  Electricity- Source of energy that can be easily converted into light, heat or power  Ampere (Amp)- Unit of measure of the rate of flow.
Chapter 6 Lesson 2. How can electricity flow? When an object gains of loses electrons, it has an electric charge. Similar to magnetic force, unlike charges.
+ Electric Circuits Parallel Circuits and Diagrams.
ELECTRICAL WIRING WIRING BASICS Written by Bobby Joslin
Electricity. TYPES OF CIRCUITS Individual electrical circuits normally combine one or more resistance or load devices. The design of the automotive electrical.
ARC-FAULT CIRCUIT INTERRUPTER(AFCI) Presented by Honey Baby George S7,EEE Roll no-21.
Joel Moody, MD, PhD, MPH Director of Safety, Risk, Policy and Innovation Why did the requirements for Arc Fault Circuit Interrupters in Dwellings Change?
  The traditional molded-case circuit breaker uses electromechanical (thermal magnetic) trip units that may be fixed or interchangeable.  An MCCB provides.
Unit 3 Lesson 3 Electric Circuits
Planning The Electrical System
Power and Energy Energy (E) is the ability to do work
Making Circuits Safe SNC1P1 Findlay.
Circuit Protection Unit 9.
Lighting Branch Circuit and Small-Appliance Circuits for Kitchen
Principles & Applications Residential Wiring Concepts
HOME ELECTRICAL SAFETY
ELECTRICAL INSTALLATION AND MAINTENANCE (EIM) 5 INSTALL ELECTRICAL PROTECTIVE DEVICES FOR DISTRIBUTION, POWER, LIGHTING, AUXILIARY, LIGHTNING PROTECTION.
AFCI Protection: AFCI Receptacles and the NEC
Your Inspection Business Name Goes Here.
Outlet Branch Circuit Arc Fault Circuit Interrupter (OBC AFCI)
Unit 3 Lesson 3 Electric Circuits
Overcurrent Protection— Fuses and Circuit Breakers
The Safe Use of Electricity
Objectives Learn about Electricity Pricing Electric systems.
Objectives Learn about 3 Phase vs. 1 phase F&N vs. 1 phase F&F
Objectives Review conductor and conduit selection
Objectives Finish with Practice circuits problems for
Household Wiring S Explain the parallel circuits, the components, and the safety aspects of household wiring. Include: switches, fuses, circuit.
Objectives Finish Transformers Introduce HW5 (Pricing)
Debunking the Myths of AFCI
Presentation transcript:

Arc Fault Circuit Interrupters

Residential fires caused by electricity occur more than 40,000 times each year in the U.S. alone. 40% are due to arcing faults!

Yearly statistics for U.S. residential electrical fires (necdigest.org) 700 deaths 3,000 injuries $700 million property damage

Division of residential wiring into zones Zone 0Zone 1Zone 2Zone 3 2 %36 %12 %50 % % of residential fires in each zone AFCI protection

bedrooms living rooms kitchens closet/storage areas garages bathrooms laundries halls dining rooms Fire locations (in descending order):

The National Electrical Code requires arc fault protection for the circuits supplying receptacle outlets in the bedrooms of new homes. The AFCI has been called the first major advance in home electrical system protection since the ground fault circuit interrupter was introduced in the late 1960's. Arc heat can exceed 6000 degrees Celsius and ignite building components such as framing, flooring, or paneling. Frayed line cords can ignite furniture, rugs or draperies. Common causes of electrical arcing faults include broken down insulation due to age or lightning strikes, poor electrical workmanship, and home owner abuse.

Circuit Breaker Review A circuit breaker can be designed to trip on:  Current faults (oldest technology)  Ground faults  Arc faults (newest technology)  All of the above

20A CoilSpring Armature Contact points A magnetic circuit breaker trips when the current in the circuit (and coil) is large enough to move the armature.

20A CoilSpring Armature Contact points The trip time is small and the trip current is much higher than the rated current. Residential breakers trip magnetically in the range of 125 to 200 A rms.

Amperes % of circuits Percentage of circuits having short circuit current available versus short circuit current Fault at the end of 6 feet of #18 appliance wire Conclusions: 1.All circuits can supply 75 A. 2.Half can supply 255 A. 3.Half can supply 203 A with appliance cord. 4.Magnetic tripping will not occur for all dead shorts. UL data for “bolted faults” (hot to neutral dead short)

20A Spring Latch Bi-metal element Contact points A thermal circuit breaker trips when the current in the circuit is high enough to heat and warp (bend) the bi-metal element.

20A Spring Latch Bi-metal element Contact points The trip time is long and the trip current is only a little more than the rated current. The time associated with the thermal tripping of breakers is specified in UL 489.

A thermal-magnetic breaker provides better protection: fast circuit interruption for severe overloads (magnetic action) and eventual circuit interruption for modest overloads (thermal action). This allows loads like motors to come on-line without tripping the breaker. Running current: 18 A Starting current: 50 A

The thermal-magnetic breaker provides adequate protection from many kinds of faults; even some caused by a lack of common sense!

However, a thermal-magnetic breaker cannot prevent fires in all cases. Here, a frayed line cord is arcing at an average current of 15 amperes. The breaker does not trip. The heat is intense! 15 A x 120 V = 1.8 kW

Arc current Time (20 ms/div) 0 A 20 A 40 A 60 A Typical arc waveform AFCIs will trip on this waveform. Other breakers will not because the rms value of the fault current is too low to produce a thermal trip and the peak value is too low to produce a magnetic trip. AFCI trip

AFCIs use an electronic circuit that looks for an “arc signature.” The trick is to differentiate the arc signature from the high-frequency noise associated with thyristor light dimmers, sparking motor commutators, and other high-frequency sources. Also, the peak starting current demanded by motors must not cause tripping. Arc signature

Test Requirements Definition Examples Operational Denotes condition that theThe AFCI device Efficacy device trips when arc fault istrips when arc fault detected.detected. Parallel Arcing Denotes an arc fault between Damaged insulation Faults the line and neutralon fixed wiring conductors in parallel with or extension cords. the loads in the circuit. Series Arcing An arc fault in series with A corroded Faults the load. Such arcs resultor loose terminal. from loose connections, or severed wires. Time and heat can cause a series fault to become a parallel fault.

Arcing to GroundDenotes an unintentional If a wall plug or arcing fault between a part switch was not operating normally at some installed properly or potential-to-ground and where connections ground. became loose. Operation Denotes the concealment of The device should Inhibition an arc fault by the normal trip even if the arc operation of circuit fault occurs on a components such as circuit that has lamp switching devices, lamp dimmers, RF line dimmers, RF filters, long filters, or long wire lengths, etc.; use of wire lengths. Faults equipment such as drills should not be fans, or other devices. masked by drills or fans.

Unwanted Tripping Denotes a tripping function Device should not in response to an arcingtrip when switching condition that is not an arcdevices, drills, fault but a condition thathairdryers, lamp occurs as part of the normal dimmers, or motors operation of circuitare operated. components. Currently UL489 allows for a product to be labeled as "mitigating the effects of arcing faults." A UL Standard (UL1699) specifically defines an arc fault circuit interrupter.