How Microsoft Does Data Centres John Dwyer Area Data Centre Mgr - International Data Centre Solutions.

Slides:



Advertisements
Similar presentations
Challenges in optimizing data center utilization
Advertisements

COS211. Source - INFINITE RESEARCH - Issue #003 | 03/08/11 | ww.infiniteresearch.netww.infiniteresearch.net 60% Growth
MidAmerican Energy Holdings Company Telecom Power Infrastructure Analysis Premium Power for Colocation Telecom Power Infrastructure Analysis February 27,
Zycko’s data centre proposition The very best products and technologies Focus on what your customers need Turning products into solutions Wide range of.
An Economical Analysis on Data Servers; Green vs. Regular Teddy Hsieh, Chris Davis, Christopher Perrenoud, Matt Nickeson, Shabnam Jahromi ETM 535-Winter.
Large Data Centers Small & Medium Data Centers Computer Rooms & Closets Network-Critical Physical Infrastructure Presented by Ian P. de la Rosa Enterprise.
1 Leading Energy Efficiency in High Tech: PG&E’s Program & Service Portfolio Mark Bramfitt, P.E. CSU Dominguez Hills.
Cooling Product Positioning
Anand Vanchi- Intel IT Ravi Giri – Intel IT Sujith Kannan – Intel Corporate Services Comprehensive Energy Efficiency of Data Centers – Case study shared.
1 NYSERDA Data Center Efficiency Program Columbia University Green Data Center Winter Workshop January 7 th, 2011.
Application Models for utility computing Ulrich (Uli) Homann Chief Architect Microsoft Enterprise Services.
Citrix Partner Update The Citrix Delivery Centre.
Thermal Management Solutions from APW President Systems
Datacenter Transformation. In the past decade US Government owned datacenters skyrocketed from 432 to 1200 However, average utilization of servers is.
 Site  Requirements  Local Resources  Initial layout ideas  Brief material selection  Supply options.
WAL-MART STORES, INC. ENERGY EFFICIENCY AND DEMAND RESPONSE.
Building A Sustainable Data Centre Strategy John Dwyer Area Data Centre Manager - International Global Foundation Services Microsoft Corporation.
MODULAR DATA CENTER PUE
Creating Energy-Efficient Data Centers
Steve Craker K-12 Team Lead Geoff Overland IT and Data Center Focus on Energy Increase IT Budgets with Energy Efficiency.
CHAPTER OVERVIEW SECTION 5.1 – MIS INFRASTRUCTURE
Architecture for Modular Data Centers James Hamilton 2007/01/08
Current trends in data centre outsourcing
CNN Center John Hester Turner Properties, Inc.. CNN Center Built in ,583,000 square feet on 18 floors Five structures joined by a common atrium.
1 May 12, 2010 Federal Data Center Consolidation Initiative.
October 23rd, 2009 Visit of CMS Computing Management at CC-IN2P3.
Resource Planning Georgia Power’s Diverse Plan to Meet Georgia’s Energy Needs AWMA Fall 2010 Conference October 7, 2010 Jeff Burleson Director of Resource.
Information Technology Division Executive Office for Administration and Finance Springfield Data Center Program Energy Strategy Meeting 9/29/2009.
1 Provision of sustainable energy. 2 The market of energy as we know it The energy market contains a predefined business suppliers users access and settlement.
Connectivity Week Santa Clara Convention Center May 23, 2011.
CHAPTER FIVE INFRASTRUCTURES: SUSTAINABLE TECHNOLOGIES
Copyright 2009 Fujitsu America, Inc. 0 Fujitsu PRIMERGY Servers “Next Generation HPC and Cloud Architecture” PRIMERGY CX1000 Tom Donnelly April
SOLUTIONS FOR THE EFFICIENT ENTERPRISE Sameer Garde Country GM,India.
LBNL and Government Data Center Programs SC07 November, 2007 William Tschudi
Liam Newcombe BCS Data Centre Specialist Group Secretary Energy Efficient Data Centres.
1 Nassau Community CollegeProf. Vincent Costa Session 7 Infrastructures Sustainable Technologies CMP 117 Business Computing: Concepts &Applications.
Virginia Information Technologies Agency Green Technology Initiatives
HPC Business update HP Confidential – CDA Required
Ulrich (Uli) Homann Chief Architect, WW Enterprise Services Microsoft Corp. Session Code: ARC307.
DELL CONFIDENTIAL 1 GREEN IT SOLUTIONS. GREEN IS EVERYWHERE DELL CONFIDENTIAL 2.
Overview of Data Center Energy Use Bill Tschudi, LBNL
STANFORD UNIVERSITY INFORMATION TECHNOLOGY SERVICES Research Data Centers- Stanford Phil Reese, Stanford University CSG Meeting, June.
Energy-Efficient Infrastructure Management in the IoT era Presented by: George Dritsanos, IT BU VP for Greece, Cyprus & Malta.
Increasing DC Efficiency by 4x Berkeley RAD Lab
Optimizing Power and Data Center Resources Jim Sweeney Enterprise Solutions Consultant, GTSI.
Ulrich (Uli) Homann Chief Architect, WW Enterprise Services Microsoft Corporation SESSION CODE: ARC305.
Green Server Room Construction Primary concerns when building a server room is size and cooling. Size can be diminished with the use of virtual servers.
Data Center Energy Use, Metrics and Rating Systems Steve Greenberg Energy Management Engineer Environmental Energy Technologies Division Lawrence Berkeley.
All content in this presentation is protected – © 2008 American Power Conversion Corporation Row Cooling.
1 ITM 1.2 How IT Decisions Impact Data Center Facilities: The Importance of Collaboration Lars Strong P.E. Upsite Technologies, Inc.
Data Center Infrastructure Total System Effectiveness Matt Gleason, CoreSite Jim Hughes, Mitsubishi Electrical Power Products.
1 PCE 2.1: The Co-Relationship of Containment and CFDs Gordon Johnson Senior CFD Manager at Subzero Engineering CDCDP (Certified Data Center Design Professional)
Restricted © Siemens AG 2016 Page 1 Tower to Rack: Driving the Next Generation of Cooling Optimization Technology Jay Hendrix, Siemens Industry Inc. Aaron.
Data Center Energy: Going Forward John Tuccillo, APC by Schneider Electric Founding Board of Director Member.
SPACE AND WATER HEATING SYSTEM SMART RENEWABLE ENERGY STORAGE NEIL STEWART MANAGING DIRECTOR DIMPLEX RENEWABLES.
[Eco 2 System] A Fundamental Twist To Data Centre Cooling Ecological Friendly & Economical.
West Cambridge Data Centre Ian Tasker Information Services.
Extreme Scale Infrastructure
CANOVATE MOBILE (CONTAINER) DATA CENTER SOLUTIONS
Data Center Stabilization
Using Heat to Increase Cooling George Hannah BEng (Hons) CEng MIMechE
© 2016 Global Market Insights, Inc. USA. All Rights Reserved Fuel Cell Market size worth $25.5bn by 2024 Data Center Cooling Market.
CHAPTER OVERVIEW SECTION 5.1 – MIS INFRASTRUCTURE
Architecture for Modular Data Centers
Energy efficient and reliable data centers
فایل ارائه حاضر توسط مرکز تحقیقات درایران « اینترنتی از اشیاء» فناوری
Liebert DSE High efficiency thermal management
Europe Power Rental Market by Type (Diesel, Gas), Power Rating, End Users (Utilities, Oil & Gas, Events, Construction, Mining,
Presentation transcript:

How Microsoft Does Data Centres John Dwyer Area Data Centre Mgr - International Data Centre Solutions

The Global Services Foundation Across the company, all over the world, around the clock Zurich.Net Online 2 MBS Online Office Labs Sharepoint.Microsoft.com Yellow box or text = pipeline Azure

Scale and Market Growth Server Infrastructure Doubling Every Year Network Capacity 9x Growth in Four Years Tripling of Data Centre Instances Dramatic Expansion of Server & Network Geo- Diversity Managed Growth of Power Capacity & Consumption Source: 3

Data Centre Economics Have Changed! Cost of physical space was a primary consideration in data centre design Cost of power and cooling has risen to prominence Data centre managers now must prioritize investment in efficient power and cooling systems to lower the total cost of operating (TCO) of their facilities. Belady, C., “In the Data Center, Power and Cooling Costs More than IT Equipment it Supports”, Electronics Cooling Magazine (Feb 2007) 4

Site Selection Internet Population Internet Peering / Network Mobile Users Power Pricing Environmental Construction Costs Tax Climate IT Labor Availability Corporate Citizenship Composite Heat Map 5

Why Power Matters… In 2006, U.S. data centres consumed an estimated 61 billion kilowatt- hours (kWh) of energy, which accounted for about 1.5% of the total electricity consumed in the U.S. that year. In the EU, data centres consumed an estimated 56 billion kilowatt- hours in As an Industry Segment, Data Centres are the fastest growing Energy Segment in the US. Current projections are that data centre power consumption will exceed 100 billion kWh by 2011 in the US and by 2020 in the EU. Those levels of power consumption in the US would necessitate the construction of 10 additional power plants. 6

Relevant Metrics at Microsoft PUE/DCiE DC Utilization Server Utilization Cost Move from Cost = f (space) Cost = f (power) X 100% The Green Grid

SCRY 8

Setting Aggressive PUE Targets 9

Environmental Control Standards 10

Source: EYP Mission Critical Facilities Inc., New York Where Data Centre Power Goes GFS’ Infrastructure Services is focusing on all the pieces of the pie Opportunities are Everywhere Opportunities are Everywhere 11

Source: EYP Mission Critical Facilities Inc., New York Where Data Centre Power Goes GFS’ Infrastructure Services is focusing on all the pieces of the pie Opportunities are Everywhere Opportunities are Everywhere Widening environment can remove chillers and drive this to zero Offline UPS technologies can drive this substantially down Virtualization, active power management 12

Three of our Data Centres 13

Data Centre Costs in the US Land - 2% Core & Shell Costs – 9% Architectural – 7% Mechanical / Electrical – 82% Since % increase year-to-year Where the costs are: >80% scale with power <10% scale with space 14

SCRY – Window to Our World 15

SCRY Helps Demonstrate Continuous Improvement 22% improvement over 3 years Follows Moore’s Law On existing data centres and helps set goals for new data centres at Microsoft

Where We Think Things Are Going … 17

18

19

Futures – Containers (Chicago) 20

Why We Like Containers 1)Can deploy at scale 2)Plug and Play 3)Drives Innovation 4)Abstracts away religious wars in competitive bid AC vs DC Air vs Liquid 5)Cost can include maintenance 6)Allows for easy cost and performance measurement 7)Creates an environment to drive competition around efficiency 8)One throat to choke Question: Is this water cooling or air cooling? 1)Can deploy at scale 2)Plug and Play 3)Drives Innovation 4)Abstracts away religious wars in competitive bid AC vs DC Air vs Liquid 5)Cost can include maintenance 6)Allows for easy cost and performance measurement 7)Creates an environment to drive competition around efficiency 8)One throat to choke Question: Is this water cooling or air cooling? 21

Container Solutions Use a standard ISO (40’, 20’, 10’ x 8 x 8’6”) shipping container to hold servers Portability allows the delivery and operation of servers in self - contained units Move costs from long lead to short lead equipment, increased ROI Capital Optimize server Delivery at 1000U+ as a unit vs. 40+U in a rack and a Single SKU & Warranty Containers seen as a solution to burst demand and temporary Microsoft’s approach is different – use them as a primary packaging unit Cost: It costs less to ship 2,000+ servers in one container than it does to ship and then install individual racks. Additional savings come from not needing raised floors or fans for each server, and requiring a lot less wiring, packaging and shipping. 22

Container Solutions The container gives us the opportunity to test new technology such as increased supply air temperature, removal of fans from servers, managed airflow with hot aisle containment, significantly increased WPSF and more efficient electrical distributions Microsoft have stand alone units running in production today and are running proof of concepts on newer technology Energy efficiency: At more than 1,000 Watts per square foot, containers allow us to power a lot more servers in a given area. This is the key reason containers have become economically viable. PUE numbers tested in a POC measured at peak ~1.3 23

Microsoft Confidential Container POC GFS DCS Ran a Proof of Concept on a Container System in Seattle, Washington, USA PUE came in between 1.2 and 1.3  Ran unit up to full load measured at 107 kW = 178 watts per server  Dropped power to unit and came back online no issues  Fans and servers ran at full speed for 7 minutes on batteries  Container spec completed and vendor RFP underway  Batteries temp remained at 75 F using probe and IR camera. Back is exposed to 85 F Need to place a temp probe at rear of battery  Ambient air temp had a large effect on temp inside the trailer due to no insulation  Permit and UL inspection took 90 days to obtain  Harmonics above 15%: varies across all 3 phases  24

Timeline started with container in late August PO approved in October First unit Live in January 5 months from Engineering to Live Delays encountered: 1 month: Flood plain re-plan New location, elevated foundation 1 month: Excell energy transformer install 1 month: Final concrete delayed due to snow Actual planning, permitting, construction effort totaled about 3 months First container Jan 5 th, third container Feb 2 nd Container vendor committing to 6-8 week turn around on order long term Virtual Earth Case Study 25

Containers - Chicago Data Centre Elevated Spine Connection Microsoft Container: 2400 Servers 375 KW Standard 40 foot shipping container Target PUE 1.25 Microsoft Container: 2400 Servers 375 KW Standard 40 foot shipping container Target PUE 1.25 Top Floor: 10.8MW Traditional COLO Capacity Ground Floor: 20 MW Container Capacity 26

27 But More Change Is Coming…

Generation 4 Modular Data Centres Challenging Many Data Centre Conventions Prefabrication of Shell and M&E Plant Pre-Assembled Containers Power Density > 1,000 Watt / Square Foot Totally Flexible Configuration (Classes) PUE < 1.1 (depending on Class) 3-5 Month Time-to-Market Reduced Cost of Entry Applying the Model-T Approach