Methods of measuring intra ocular pressure. What is intra ocular pressure ? Definition Intra ocular pressure refers to the pressure exerted by the intra.

Slides:



Advertisements
Similar presentations
Use lenses to direct light in order to enlarge images
Advertisements

Goldmann Applanation Tonometry
Eye and Ear Assessment by Sharon Kerr, MSN, RN Spring 2010.
Technician role in fitting lenses
Study Lesson 2 Using drawing tools & applied geometry.
Alcohol Stove Design with Canister Paul Young-Davies Klondike Derby 2010.
Goldmann Tonometer.
DUCT. LACRIMAL DUCT PATTENCY  Anatomy of the lacrimal apparatus  It is situated in upper orbital outer lacrimal side  Function of the lacrimal apparatus.
Transpalpebral Tonometry H.v.Below, O.Riemer Common practice for ambulant and stationary ophthalmology Grimma/Sachsen.
Medication Assistant Training Module 5 Eyes Ears Nose.
Nasopharyngeal Specimen Collection Specimen Collection Before starting, ensure swab collection equipment is on hand. You will need: Nasopharyngeal swab.
Microscope Basics T. Trimpe
Introduction to a Microscope.  From ancient times, man has wanted to see things far smaller than could be perceived with the naked eye.
1 Microscope operation The practical is divided into a number of sections. You will need your Practical Manual.
Schiotz tonometer.
Prepared by : SIG, Dermatology Nursing, IADVL.  clean the eye of discharge and crusts  prior to eye drop installation  soothe eye irritation  prevent.
SCHIRMERS TEST PURPOSE. To measure the quantity of tear secretion To measure the quantity of tear secretion Special filter paper is used for this test.
Skills Instruction Backpacking Stoves Your Name Troop Guide N Totem Here.
Applanation tonometry:
SUR 111 LAB 4 Entering the Sterile Role. Overview Surgical Hand Scrub (12-1) Toweling Gowning (12-1) Closed Gloving Removal of instrument tray from container.
Recent Advances in IOP measurements
Fitting of Personal Protective Equipment (PPE) and taking swabs for influenza This presentation is for quick reference only. You must also complete the.
Ocular Examination Instruments / Devices
CATHETERISATION. Ursula A Wood. Clinical Educator. Bradford Teaching Hospitals.
VITAL SIGNS: T, P, R, & BP.
Vision Screening. Given to measure individual’s visual acuity Given as part of physical exam or to detect eye disease Conduct exam in a well-lighted room.
INTRAOCULAR PRESSURE LECTURE
Optometry practices can be in various locations  Shopping centres  Medical centres  Individual buildings  People’s homes (domicillary)
Comparison of the Diaton Transpalpebral Tonometer Versus Goldmann Applanation R. S. Davidson 1 ; N. Faberowski 2 ; R. J. Noecker 3 ; M. Y. Kahook 1 1.
1 Eye Injuries Pakistan ICITAP. 2 Learning Objectives To be able to identify both a normal eye and an eye suffering from an abnormality To be familiar.
MISCELLANEOUS TREATMENTS. 2 Foreign Body in the Eye  Check for contact lenses, particularly in unresponsive patient  If found, do not attempt to remove.
Keratometry Walter Huang, OD Yuanpei University Department of Optometry.
Module 3c: ASSESSMENT PROCEDURES Module 3c: ASSESSMENT PROCEDURES.
DO NOW: 1.Hand in the field trip brainstorming you wrote on Friday. 2.Take out your microscope Green packets from last week. 3.In your NOTES section of.
Kinetic Energy and Heat Transfer
Eye Injuries Chapter 25. Anatomy of the Eye Eye Injuries Can produce severe complications Examine pupil for shape and reaction (if you can see it) Can.
Basic Screen Printing Procedures for T-Shirts GOP_5-2 Screen Printing.
NIGHT DUTY RESPONSIBILITIES of MLOP in the Main Hospital WARD NIGHT DUTY RESPONSIBILITIES of MLOP in the Main Hospital WARD.
Measuring and Recording a Blood Pressure. Blood Pressure (BP) is one of the four vital signs you will be required to take. It is important that your recording.
Microscopes SC.912.L.14.4 Compare and contrast structure and function of various types of microscopes.
Chapter 14.
1 04/18/06 Titmusi400 Vision Screener User Training.
LSM780 Live Cell Turn On/Turn Off Instructions Kim Peifley 07/13/15.
Biology Chapter 1 Biology as a science. Scientific Method.
Tonometry Objective measurement of IOP based, most commonly, on the forces required to flatten the cornea,or the degree of corneal indention produced.
Direct ophthalmoscopy
ACCU-CHEK Inform II Operator Training
STAINING R.SEENIAMMAL AEH, THENI.
Eyes Inspection Visual Acuity Visual Fields Pupillary Response
Examination techniques in ophthalmology E. Vlková et al.
Coordination and Response in Plants and Animals
TONOMETER.
Intravenous cannulation
Sara Raftery, Mary Clynes and Colleen O’Neill
Temperatures.  amount of heat in the body  Body heat is produced when food is used for energy  Heat is lost through breath, urine, feces, and skin.
MICROSCOPE A compound microscope is an expensive precision instrument that requires special care and handling. let’s learn the parts of a compound microscope,
How to dry mat your photos. Supplies White or black mat board Image Millimeter ruler T-square ruler Mechanical pencil Exacto Knife and Green Gridded cutting.
Proper Micropipette Technique and Slide Preparation
General Biology lab Microscope.
Autorefractor Instructions. Seat the patient at the instrument. Hold and stabilize the chair as the patient sits down, especially if the chair has wheels.
Keratometry and Corneal Topography Instructions. Generally the keratometer & corneal topographer are combined into one instrument that does each reading.
Basics of Medical Equipment Lecture 5
Assisting in slit lamp examination (Applanation & Gonio)
Oral Glucose Tolerance Test
Rocket Difficulty Time Approximately 30–35 minutes Art Deco Clock
L02: Tear break up time (BUT)
Irrigation of the eye.
INTERFERENCE.
3 mm holes ________________ distance water traveled
2/24/2013.
Presentation transcript:

Methods of measuring intra ocular pressure

What is intra ocular pressure ? Definition Intra ocular pressure refers to the pressure exerted by the intra ocular contents on the coats of the eyeball. Intra ocular pressure refers to the pressure exerted by the intra ocular contents on the coats of the eyeball. It is maintained by the equilibrium between the aqueous humour formation, its outflow and the episcleral venous pressure It is maintained by the equilibrium between the aqueous humour formation, its outflow and the episcleral venous pressure Normal IOP – 10.2mmhg to 20.6mmhg

Types of Tonometer Schiotz Tonometer Schiotz Tonometer Applanation Tonometer- Goldman Applanation Tonometer- Goldman Tonopen Tonopen Pulse air Tonometer Pulse air Tonometer Non contact Tonometer Non contact Tonometer

Schiotz Tonometer Devised in the year 1905 Schiotz tonometer is the instrument which is used to measure the intra ocular pressure ( IOP ) Schiotz tonometer is the instrument which is used to measure the intra ocular pressure ( IOP )

Requirements (Schiotz tonometer) Schiotz tonometer with 5.5gm,7.5gm and 10gm weight Schiotz tonometer with 5.5gm,7.5gm and 10gm weight Measurement chart (Friedan Wald chart) Measurement chart (Friedan Wald chart) 4% Xylocaine as local anaesthetic 4% Xylocaine as local anaesthetic Wiper jar (Sterile) Wiper jar (Sterile) Kidney type tray Kidney type tray Antibiotic drops (Chloramphenical ) Antibiotic drops (Chloramphenical ) 2% propanolol &Tissue paper 2% propanolol &Tissue paper

Method Explain the procedure to the patient and make him comfortable. He should be lying down with head on the pillow. Explain the procedure to the patient and make him comfortable. He should be lying down with head on the pillow. Check the instrument by placing over the model. Now the indicator ‘0’in the scale Check the instrument by placing over the model. Now the indicator ‘0’in the scale Wash and dry hands. Wash and dry hands. Instill one drops of lignocaine 4%eyedrops in the Eye (use pouch technique) – Explain the burning sensation & other points Instill one drops of lignocaine 4%eyedrops in the Eye (use pouch technique) – Explain the burning sensation & other points Allow 2to5minutes for the local drops to act. Allow 2to5minutes for the local drops to act.

Ask the patient to look straight up Ask the patient to look straight up Separate the eyelids, putting no pressure on the eye. Fingers should rest on the orbital margin. Separate the eyelids, putting no pressure on the eye. Fingers should rest on the orbital margin. Hold the tonometer so that footplate rests on the center of the cornea. Hold the tonometer so that footplate rests on the center of the cornea. Look at the scale of the Tonometer to find out the degree of indentation. If the weight is not enough to indent the cornea, use a heavier weight Look at the scale of the Tonometer to find out the degree of indentation. If the weight is not enough to indent the cornea, use a heavier weight Use the chart to calculate the intraocular pressure for that particular weight, and that degree of indentation Use the chart to calculate the intraocular pressure for that particular weight, and that degree of indentation Record the intraocular pressure in the patients note’s Record the intraocular pressure in the patients note’s

Sterilizing the instruments Before replacing the tonometer, dismantle it and clean the parts. Before replacing the tonometer, dismantle it and clean the parts. Remove the weights, unscrew the plunger and clean them using swabs dipped in alcohol Remove the weights, unscrew the plunger and clean them using swabs dipped in alcohol Heat the footplate over the blue flame of the spirit lamp for two minutes. Now the footplate is sterilized Heat the footplate over the blue flame of the spirit lamp for two minutes. Now the footplate is sterilized Keep the tonometer over the sterile wipers/pad so that it cools down to room temperature Keep the tonometer over the sterile wipers/pad so that it cools down to room temperature Check the instruments by placing over the model. Now the indicator should show ‘0’in the scale Check the instruments by placing over the model. Now the indicator should show ‘0’in the scale

Tonopen Tonopen could be used for children and adults Tonopen could be used for children and adults Before measuring, local anesthetic drops are to be applied Before measuring, local anesthetic drops are to be applied The patient can either sit or lie down The patient can either sit or lie down

The tip of tonopen touches the central part of cornea. We should handle it smoothly The tip of tonopen touches the central part of cornea. We should handle it smoothly This could be used for patients who can not be checked with Applanation Tonometer &corneal disorder patients & children This could be used for patients who can not be checked with Applanation Tonometer &corneal disorder patients & children

Pulse Air Tonometer Pulse Air Tonometer could be used for all age group. Pulse Air Tonometer could be used for all age group. Mostly used for children Mostly used for children It could be used effectively on children when they sleep It could be used effectively on children when they sleep Only through air pressure we will be able to measure Only through air pressure we will be able to measure

This is an automatic Tonometer This is an automatic Tonometer Need not use anesthetic drops Need not use anesthetic drops Normal value 12 to 21mmhg Normal value 12 to 21mmhg Pulse Air Tonometer = Non contact Tonometer Pulse Air Tonometer = Non contact Tonometer Distance of Tonometer & Cornea is 10 to 12mm Distance of Tonometer & Cornea is 10 to 12mm

Non contact Tonometer

This is like the slit lamp This is like the slit lamp Patients is to be focused to see the red-light inside the Tonometer Patients is to be focused to see the red-light inside the Tonometer Picture of the eye could be seen on the screen Picture of the eye could be seen on the screen A white dot will be seen in the cornea A white dot will be seen in the cornea The MLOP should focus the white dot and click it The MLOP should focus the white dot and click it At the time of focusing, if you see the word- ’Forward’,you should adjust the joystick in front side. At the time of focusing, if you see the word- ’Forward’,you should adjust the joystick in front side.

At the time of focusing, if you see the word-’Too close’,you should adjust the joystick in back side. At the time of focusing, if you see the word-’Too close’,you should adjust the joystick in back side. Automatically the reading will be shown in the screen itself Automatically the reading will be shown in the screen itself This will be useful for injury and redness and post operative patients This will be useful for injury and redness and post operative patients No need to use local drops. No need to use local drops.

Applanation Tonometer (Goldman’s)

Goldman’s applanation Tonometer is capable of measuring intraocular pressure accurately to 0.5mm Goldman’s applanation Tonometer is capable of measuring intraocular pressure accurately to 0.5mm It is more accurate than Schiotz Tonometer It is more accurate than Schiotz Tonometer This is used with slit lamp microscope This is used with slit lamp microscope It measures the area of the circle made flat by the instrument on the flat and spherical part of the cornea It measures the area of the circle made flat by the instrument on the flat and spherical part of the cornea It has prism with external area of the Tonometer It has prism with external area of the Tonometer A measuring drum attached to the slit lamp is inserted into the handle over the chamber A measuring drum attached to the slit lamp is inserted into the handle over the chamber

Procedure Explain the method to the patient and keep the patient in front of the slit lamp Explain the method to the patient and keep the patient in front of the slit lamp Apply local anesthetic to the eye and add a drop of flourescein with the help of a flourescein strip Apply local anesthetic to the eye and add a drop of flourescein with the help of a flourescein strip Make the patients rest his chin in its place Make the patients rest his chin in its place Use blue filter to focus the conjunctiva, open the slit beam, which is angled at 45-60° to the chamber Use blue filter to focus the conjunctiva, open the slit beam, which is angled at 45-60° to the chamber

Make the patient open her eyes and keep that straight.There should be no friction between the margin of the lid and the instrument lest it causes the patient to blink Make the patient open her eyes and keep that straight.There should be no friction between the margin of the lid and the instrument lest it causes the patient to blink When the patient is ready, arrange the measuring drum. Move it along with slit lamp control lever so that the Tonometer is near the centre of the cornea When the patient is ready, arrange the measuring drum. Move it along with slit lamp control lever so that the Tonometer is near the centre of the cornea Two bright yellow and green semicircles will be visible through the eyepiece of the microscope. Focus them with the help of the control lever so that the vertical lines separating the two parts is equidistant from top and bottom Two bright yellow and green semicircles will be visible through the eyepiece of the microscope. Focus them with the help of the control lever so that the vertical lines separating the two parts is equidistant from top and bottom

Adjust the measuring drum towards upper valves. THE TWO SEMICIRCLES SUPERIMPOSE. The reading at which the two semicircles superimpose is noted. Adjust the measuring drum towards upper valves. THE TWO SEMICIRCLES SUPERIMPOSE. The reading at which the two semicircles superimpose is noted. Multiply the reading by 10. The intraocular pressure is read in mm of Hg Multiply the reading by 10. The intraocular pressure is read in mm of HgNote As the tonometer touches the cornea, it may cause infection. So clean the applanating tip and sterilize it with an antiseptic As the tonometer touches the cornea, it may cause infection. So clean the applanating tip and sterilize it with an antiseptic