Pierpaolo Valerio.  CLICpix is a hybrid pixel detector to be used as the CLIC vertex detector  Main features: ◦ small pixel pitch (25 μm), ◦ Simultaneous.

Slides:



Advertisements
Similar presentations
Sci-Fi tracker for IT replacement 1 Lausanne 9. December 2010.
Advertisements

STATUS OF MEDIPIX-3, PLANS FOR TIMEPIX-2 X. Llopart.
MDT-ASD PRR C. Posch30-Aug-02 1 Specifications, Design and Performance   Specifications Functional Analog   Architecture Analog channel Programmable.
5ns Peaking Time Transimpedance Front End Amplifier for the Silicon Pixel Detector in the NA62 Gigatracker E. Martin a,b J. Kaplon b, A. Ceccucci b, P.
NA62 front end architecture and performance Jan Kaplon/Pierre Jarron.
TOT01 ASIC – First Results (STS prototype chip – first results) Krzysztof Kasiński, Paweł Gryboś,Robert Szczygieł
GOSSIPO-2 chip: a prototype of read-out pixel array featuring high resolution TDC-per-pixel architecture. Vladimir Gromov, Ruud Kluit, Harry van der Graaf.
Timepix2 power pulsing and future developments X. Llopart 17 th March 2011.
Power pulsing strategy with Timepix2 X. Llopart 10 th May 2011 Linear Collider Power Distribution and Pulsing workshop Timepix3.
Evaluation of 65nm technology for front-end electronics in HEP Pierpaolo Valerio 1 Pierpaolo Valerio -
A radiation-tolerant LDO voltage regulator for HEP applications F.Faccio, P.Moreira, A.Marchioro, S.Velitchko CERN.
MEDIPIX3 TESTING STATUS R. Ballabriga and X. Llopart.
A Serializer ASIC for High Speed Data Transmission in Cryogenic and HiRel Environment Tiankuan Liu On behalf of the ATLAS Liquid Argon Calorimeter Group.
Design of Robust, Energy-Efficient Full Adders for Deep-Submicrometer Design Using Hybrid-CMOS Logic Style Sumeer Goel, Ashok Kumar, and Magdy A. Bayoumi.
2. Super KEKB Meeting, DEPFET Electronics DEPFET Readout and Control Electronics Ivan Peric, Peter Fischer, Christian Kreidl Heidelberg University.
CARIOCA (Cern and RIO Current Amplifier). The CARIOCA chip has 8 binary output, therefore DIALOG has 16 PCH as input channels and has up to 8 LCH as output.
A. Rivetti Gigatracker meeting, dec 2009 Charge measurement with the TDC per pixel architecture A. Rivetti, G. Dellacasa S. Garbolino, F. Marchetto, G.
Building blocks 0.18 µm XFAB SOI Calice Meeting - Argonne 2014 CALIIMAX-HEP 18/03/2014 Jean-Baptiste Cizel - Calice meeting Argonne 1.
Radiation Tests on IHP’s SiGe Technologies for the Front-End Detector Readout in the S-LHC M. Ullán, S. Díez, F. Campabadal, G. Pellegrini, M. Lozano CNM.
Fully depleted MAPS: Pegasus and MIMOSA 33 Maciej Kachel, Wojciech Duliński PICSEL group, IPHC Strasbourg 1 For low energy X-ray applications.
Progress on STS CSA chip development E. Atkin Department of Electronics, MEPhI A.Voronin SINP, MSU.
The AGIPD Detector for the European XFEL Julian Becker (DESY), Roberto Dinapoli (PSI), Peter Goettlicher (DESY), Heinz Graafsma (DESY), Dominic Greiffenberg.
Specifications & motivation 2  Lowering integration time would significantly reduce background  Lowering power would significantly reduce material budget.
1 Development of the input circuit for GOSSIP vertex detector in 0.13 μm CMOS technology. Vladimir Gromov, Ruud Kluit, Harry van der Graaf. NIKHEF, Amsterdam,
Robert Szczygieł IFJ PANSPIE 2005 Radiation hardness of the mixed-mode ASIC’s dedicated for the future high energy physics experiments Introduction Radiation.
Update on CLICpix design
CBM workshop – GSI, April 18th – 20th A. Rivetti Pixel detector development for PANDA A.Rivetti INFN – Sezione di Torino.
DESIGN CONSIDERATIONS FOR CLICPIX2 AND STATUS REPORT ON THE TSV PROJECT Pierpaolo Valerio 1.
Power Pulsing in Timepix3 X. Llopart CLIC Workshop, January
AMS HVCMOS status Raimon Casanova Mohr 14/05/2015.
Valerio Re, Massimo Manghisoni Università di Bergamo and INFN, Pavia, Italy Jim Hoff, Abderrezak Mekkaoui, Raymond Yarema Fermi National Accelerator Laboratory.
65 nm CMOS analog front-end for pixel detectors at the HL-LHC
A. Rivetti Villa Olmo, 7/10/2009 Lepix: monolithic detectors for particle tracking in standard very deep submicron CMOS technologies. A. RIVETTI I.N.F.N.
ClicPix ideas and a first specification draft P. Valerio.
Thanushan Kugathasan, CERN Plans on ALPIDE development 02/12/2014, CERN.
10th Trento Workshop on Radiation Detectors HVCMOS Sensors for LHC Upgrade Felix Michael Ehrler, Robert Eber Daniel Münstermann, Branislav Ristic, Mathieu.
CMOS MAPS with pixel level sparsification and time stamping capabilities for applications at the ILC Gianluca Traversi 1,2
65 nm technology for HEP: status and perspectives Pierpaolo Valerio, CERN on behalf of the RD53 collaboration.
RD53 Analog IP blocks WG : developments and plans at CPPM M. Barbero, L. Gallin Martel (LPSC), Dzahini (LPSC), D. Fougeron, R. Gaglione (LAPP), F. Gensolen,
LHCb Vertex Detector and Beetle Chip
Pixel detector development: sensor
65 nm CMOS technology in High Energy Physics Pierpaolo Valerio CERN
-1-CERN (11/24/2010)P. Valerio Noise performances of MAPS and Hybrid Detector technology Pierpaolo Valerio.
FE-I4 irradiated chip tests at low temperature M. Menouni, P. Breugnon, A. Rozanov (CPPM - Aix-Marseille Université)
CLICPIX AND MEDIPIX3-TSV PROJECTS Pierpaolo Valerio.
S. Bota – Calorimeter Electronics overview - July 2002 Status of SPD electronics Very Front End Review of ASIC runs What’s new: RUN 4 and 5 Next Actions.
Standard electronics for CLIC module. Sébastien Vilalte CTC
FPIX2: A rad-hard pixel readout chip for BTeV David Christian Fermilab Homestead September 14, 2000 Vertex 2000 f.
CERN PH MIC group P. Jarron 07 November 06 GIGATRACKER Meeting Gigatracker Front end based on ultra fast NINO circuit P. Jarron, G. Anelli, F. Anghinolfi,
CBM 12 th Meeting, October 14-18, 2008, Dubna Present status of the first version of NIHAM TRD-FEE analogic CHIP Vasile Catanescu and Mihai Petrovici NIHAM.
R. Kluit Nikhef Amsterdam R. Kluit Nikhef Amsterdam Gossopo3 3 rd Prototype of a front-end chip for 3D MPGD 1/27/20091GOSSIPPO3 prototype.
UPDATE ON CLICPIX2 DESIGN Pierpaolo Valerio Edinei Santin
Update on works with SiPMs at Pisa Matteo Morrocchi.
Medipix3 chip, downscaled feature sizes, noise and timing resolution of the front-end Rafael Ballabriga 17 June 2010.
L. Ratti a,b, M. Dellagiovanna a, L. Gaioni a,b, M. Manghisoni b,c, V. Re b,c, G. Traversi b,c, S. Bettarini d,e, F. Morsani e, G. Rizzo d,e a Università.
Technical status of the Gossipo-3 : starting point for the design of the Timepix-2 March 10, Vladimir Gromov NIKHEF, Amsterdam, the Netherlands.
NOISE MEASUREMENTS ON CLICPIX AND FUTURE DEVELOPMENTS Pierpaolo Valerio.
NEWS FROM MEDIPIX3 MEASUREMENTS AND IMPACT ON TIMEPIX2 X. Llopart CERN.
Week 22: Schematic Week 23-Week 27: Routing Gerber files have been available since 9th July 1st prototype: – PCB manufacturer: supervised by KIT – Cabling:
ASICs1 Drain Current Digitizer Chip (DCD) Status and Future Plans.
A General Purpose Charge Readout Chip for TPC Applications
Charge sensitive amplifier
LHC1 & COOP September 1995 Report
INFN Pavia / University of Bergamo
Functional diagram of the ASD
High Rate Photon Irradiation Test with an 8-Plane TRT Sector Prototype
OmegaPix 3D IC prototype for the ATLAS upgrade SLHC pixel project 3D Meeting 19th March, 2010 A. Lounis, C. de La Taille, N. Seguin-Moreau, G.
Readout Electronics for Pixel Sensors
Readout Electronics for Pixel Sensors
Readout Electronics for Pixel Sensors
Presentation transcript:

Pierpaolo Valerio

 CLICpix is a hybrid pixel detector to be used as the CLIC vertex detector  Main features: ◦ small pixel pitch (25 μm), ◦ Simultaneous TOA and TOT measurements ◦ Power pulsing ◦ Data compression  A demonstrator of the CLICpix architecture with an array of 64x64 pixels has been submitted using a commercial 65 nm technology and tested  The technology used for the prototype has been previously characterized and is being validated for HEP use and radiation hard design up to very high doses mm 3 mm

3  The analog front-end shapes photocurrent pulses and compares them to a fixed (configurable) threshold  Digital circuits simultaneously measure Time-over-Threshold and Time-of-Arrival of events and allow zero-compressed readout Input CSA 4-bit Th.Adj DAC Feedback network Polarity TOA ASM TOT ASMClk divider 4-bit TOT counter 4-bit TOA counter HF Bottom pixel Top pixel Configuration data: Th.Adj, TpulseEnable, CountingMode, Mask Threshold V test_pulse Clock

4 Simulations Measurement TOA Accuracy < 10 ns Gain44 mV/ke - 40 mV/ke - Dynamic Range up to 40 ke - (configurable) Non-Linearity (TOT) < 8% at 40 ke - < 4% at 40 ke - Equivalent Noise ~60 e - (without sensor capacitance) ~51 e - (with a 6% variation r.m.s.) DC Spread (uncalibrated) σ = 160 e - σ = 128 e - DC Spread (calibrated) σ = 24 e - σ = 22 e - Power consumption 6.5 μ W7 μ W Measurements expressed in electrons depend on the test capacitance. A nominal value of 10 fF was assumed here

 CLIC radiation hardness requirement: <1Mrad  LHC upgrade: 1Grad! But…  Knowing how blocks react to radiation can be useful to better understand how they work  Test results can be very useful for people using 65 nm technology for LHC applications  … such as the RD53 collaboration 5

 Collaboration on future pixel chips for ATLAS/CMS/LCD  Development and characterization of circuits and building blocks needed for pixel chips  Share circuit blocks  Some blocks which will be useful for CLIC are already being designed (bandgap, I/O cells…)  Work is ongoing using the same technology used for CLICpix 6

 Threshold voltage shift in both NMOS and PMOS devices  Leakage current increase in NMOS transistors  Very large decrease in PMOS transconductance for high radiation doses (>200 Mrads), dependent on the device size  Reduced speed of digital circuits  Testing on single transistors have been carried out by researchers at CERN and CPPM 7

 A in-house calibrated X-ray test setup was used to evaluate Total Dose effects  Tests were automated using a linux PC and the already tested CLICpix board and Spartan-6 FPGA  Two different chips were tested and they showed similar results 8

 Small radiation steps in the dose range interesting to the CLIC project (< 10 Mrad)  Larger steps for higher doses (until the chip stopped working)  The main analog performances of the chip were monitored throughout the test 9

 Digital power consumption had a very limited variation up to very high dose rates  The digital features of the chip kept working normally for the whole test  The analog power consumption plummeted after ~250 Mrads (after which the chip was not functional anymore) 10  The PMOS current mirror used to bias the chip “switched off” at high doses, making it impossible to power the chip

11  The chip uses a PMOS current mirror to copy an external reference current  At high doses, the PMOS devices in the mirror are unable to provide enough current  A final version of CLICpix would use a bandgap to generate a reference voltage inside the chip, making it more robust VDD I ext I ref VGVG VDD

 DACs used for biasing kept their linearity for low rates, with a minimal variation of their characteristics  At high rates (>300Mrads) a large non-linearity appears 12

13 >600 mV ~200 mV A I out I DAC  DACs use PMOS switches to control a current mirror for each bit  At high rates switches irradiated while they are ON (their control voltage is GND) degrade more quickly than the one irradiated while they are OFF  Damaged switches are unable to let the nominal current pass (they are permanently OFF) VDD A

 The voltage gain of the analog front-end shows some variation for low rates, due to a reduction of the gain of the preamplifier or a decrease in the feedback current  A higher variation can be noted for higher doses 14

 Peaking time of the front-end is almost constant up to high rates  The delay due to the logic and the discriminator is constant  The measurement uses the internal clock for a 10 ns accurcay. The peaking time measurement is not “clean” because of low statistics 15

 Variation of threshold voltage is limited for low rates and it is compatible with the drift in the DAC characteristic  Different pixels show the same behavior 16

 TOT gain increases with radiation dose, especially at high doses  This effect is probably caused by a decrease in the front-end feedback current 17

 All I/O interfaces and digital structures did not show any significant degradation during irradiation, even after the analog front-end stopped working  The chips regained some functionality after a week of annealing at room temperature (the total power consuption could be set back to pre-rad value). After annealing measurement will be analyzed soon  The measurement was performed at a doserate of ~150 krad/minute (~75 krad/minute for the first 10 Mrads). The high doserate could have an effect on the radiation damage and needs to be explored 18

 The performances of CLICpix with respect to radiation damage were studied  In the sub-Mrad range, where CLIC will operate, the chip did not show any significant change, even in a high doserate test. Periodic re- calibration can anyway be performed to correct any DAC characteristics and threshold drift  At very high doses (>200 Mrads), even basic blocks fail (switches, current mirrors). Further investigation on simpler structures is needed to develop circuits robust to such doses  Data on annealing and noise measurements are still being acquired and analyzed 19

Thanks for your attention