CCDs in space: the effects of radiation on Hubble’s Advanced Camera for Surveys (ACS) Max Mutchler, David Golimowski (Space Telescope Science Institute),

Slides:



Advertisements
Similar presentations
A NEW CTE PHOTOMETRIC CORRECTION FORMULA FOR ACS Marco Chiaberge TIPS meeting 05/16/2012.
Advertisements

X-ray Imaging Spectrometers (XIS) of Astro-E2 Hironori Matsumoto (Kyoto University) and the XIS team 1. Overview Astro-E2 is the fifth Japanese X-ray Astronomy.
DESCRIBING TRENDS OR MOVEMENTS IN GRAPHS/CHARTS
What makes an image memorable?
Return to Hubble: Servicing Mission 4 Dr. Frank Summers Space Telescope Science Institute April 2, 2009.
1 ACS Status Update STScI TIPS Meeting 19-October-2006 Ken Sembach.
Armin Karcher, LBNL IEEE/NSS 2001 Proton Radiation Damage in P-Channel CCDs Fabricated on High-Resistivity Silicon. C. Bebek, D. Groom, S. Holland, A.
ASTR1002 Mystery Object Tute. Patterns in the Night Sky Imagine, once again, that you live in Mog, where the clouds recently cleared (for the first time.
SDW Marco Sirianni Marco Sirianni (ESA/STScI) Max Mutchler (STSci) Radiation Damage in HST Detectors.
Following the Photons… Empirical, Pixel-Based Corrections for CTE Jay Anderson STScI October 12, 2011 Back-Tracking the Electrons.
CHARGE COUPLING TRUE CDS PIXEL PROCESSING True CDS CMOS pixel noise data 2.8 e- CMOS photon transfer.
2008/10/21 J. Fontenla, M Haberreiter LASP – Univ. of Colorado NADIR MURI Focus Area.
Digital Technology 14.2 Data capture; Digital imaging using charge-coupled devices (CCDs)
A101 Slide Set: Young Galaxies Grow Developed by the GALEX Team 1 Topic: Galaxies Concepts: Ultraviolet observations, galaxy formation, galaxy evolution,
Yerkes Astrophysics Academy for Young Scientists (YAAYS) January 20, 2007 Invitational Festival.
LIVE INTERACTIVE YOUR DESKTOP January 28, 2010 NASA/NSTA Web Seminar Series How Telescopes Have Changed Our View of the Universe Hubble’s Universe:
FEATURE EXTRACTION FOR JAVA CHARACTER RECOGNITION Rudy Adipranata, Liliana, Meiliana Indrawijaya, Gregorius Satia Budhi Informatics Department, Petra Christian.
We have the first, direct measure of photometric loss due to imperfect CTE on ACS.
S. Baggett, J. Anderson, K. S. Long, J. W. MacKenty, K. Noeske, J. Biretta, and the WFC3 team (STScI) WFC3 : Understanding and mitigating UVIS charge.
AST3 detector properties
Pipeline calibrations of ACS data Max Mutchler Hubble Space Telescope Calibration Workshop October 2005.
Summary of Lesser Packaged SNAP CCDs to Date. Lesser Packaged CCDs (UASN5071) (UASN5450) (UASN5451) (UASN5452)
NGC 6217 in DSI mode with F658N Mosaic before new superbias why we don’t release images until after SMOV! ACS CCD monitoring and pipeline calibration review.
TIPS presentation 19 July 2007Charles Proffitt COS-STIS TeamPage 1 STIS FUV MAMA Dark Current Charles Proffitt COS-STIS Team.
Understanding Persistence: A 3D Trap Map of an H2RG Imaging Sensor
11 th RD50 Workshop, CERN Nov Results with thin and standard p-type detectors after heavy neutron irradiation G. Casse.
The B-V colors and photometric variability of Nix and Hydra, Pluto’s two small satellites Max Mutchler (STScI) S. Alan Stern (SwRI) Hal Weaver (JHU/APL)
Molecular Gas and Dust in SMGs in COSMOS Left panel is the COSMOS field with overlays of single-dish mm surveys. Right panel is a 0.3 sq degree map at.
National Science Foundation Identification of an intrinsic difficulty in fabricating efficient power devices Sokrates T. Pantelides, Vanderbilt University,
May 21, 2009John MacKenty, STScI1 WFC3 SM4 Events and Current Status.
SHINE SEP Campaign Events: Long-term development of solar corona in build-up to the SEP events of 21 April 2002 and 24 August 2002 A. J. Coyner, D. Alexander,
10/26/20151 Observational Astrophysics I Astronomical detectors Kitchin pp
SNAP CCD Development Progress Hakeem Oluseyi January 9, 2003.
D. Golimowski2010 STScI Calibration Workshop1 ACS after SM4: New Life for an Old Workhorse David Golimowski Space Telescope Science Institute 22 July 2010.
SPACE TELESCOPE SCIENCE INSTITUTE Operated for NASA by AURA TIPS: STIS Report Paul Goudfrooij 1.Unusual Target ACQ Failures: Update & Resolution 2.Calibration.
ACS STATUS Linda Smith (thanks to David Golimowski for providing the slides)
MIT Lincoln Laboratory NU Status-1 JAB 11/20/2015 Advanced Photodiode Development 7 April, 2000 James A. Burns ll.mit.edu.
STS-125 Hubble Space Telescope(HST) Servicing Mission 4 (SM4) Overview Presented By: Jerry L. Ross October 6, 2009 Prague, Czech Republic 1.
Observational Astrophysics I
The B-V colors and photometric variability of Nix and Hydra, Pluto’s two small satellites Max Mutchler (STScI) S. Alan Stern (SwRI) Hal Weaver (JHU/APL)
ACS/WFC CTE correction for point source photometry Marco Chiaberge ACS Team STScI.
UPDATED CTE CORRECTION FORMULAE FOR ACS Marco Chiaberge Pey Lian Lim, Vera Kozhurina-Platais, Marco Sirianni Ron Gilliland, Jennifer Mack.
The Hubble Space Telescope explores the limits of “roundness”: Ceres and Vesta Max Mutchler (Space Telescope Science Institute), Lucy McFadden, Jian-Yang.
Chapter 38 Diffraction Patterns and Polarization.
TIPS - Oct 13, 2005 M. Sirianni Temperature change for ACS CCDs: initial study on scientific performance M. Sirianni, T. Wheeler, C.Cox, M. Mutchler, A.
The HESSI Imaging Process. How HESSI Images HESSI will make observations of the X-rays and gamma-rays emitted by solar flares in such a way that pictures.
HLA WFPC2 Source List Photometric Quality Checks Version: August 25, 2008 Brad Whitmore 1.Introduction 2.Comparison with Ground-based Stetson Photometry.
Hubble Space Telescope By Brittany Bellows Physics 1040 – Spring 2011.
F Don Lincoln, Fermilab f Fermilab/Boeing Test Results for HiSTE-VI Don Lincoln Fermi National Accelerator Laboratory.
Introduction NICMOS (Near-Infrared Camera and Multi-Object Spectroscopy) was installed on the Hubble Space Telescope during SM2 in 1997 and has been the.
SCT WeekDecember 3, Block of Low Gain Analysis and Solutions A. Ciocio - LBNL.
February 21, 2002TIPS meeting1 "Data contained herein is exempt from ITAR regulations under CFR 125.4(13) -- data approved for public disclosure." TIPS.
CCD Image Processing: Issues & Solutions. CCDs: noise sources dark current –signal from unexposed CCD read noise –uncertainty in counting electrons in.
Installation of the ACS Guido De Marchi – TIPS meeting – Guido De Marchi - ESA/STScI - ACS Group The ACS was installed on board the HST on the.
Hubble Update for “Teacher’s Thursday” on 10 April 2003 Max Mutchler Space Telescope Science Institute.
ACS WFC Flat-Field Changes Temperature change from -77 C to -81 C on July 4, 2006 leads to expected changes for flat fields. Are L-flat measures stable.
Marco Sirianni TIPS 12/18/2003 Anomalous scattered light in ACS/WFC Data Marco Sirianni D. Van Orsow, A. Welty, T. Wheeler R. Gilliland, R. van der Marel.
STIS Status TIPS, September 17, 2009 Charles Proffitt for the STIS team.
S. Baggett, J. Anderson, J. MacKenty, J. Biretta, K. Noeske, and the WFC3 team (STScI) HST/WFC3 UVIS Detectors: Radiation Damage Effects and Mitigation.
Wilkinson Microwave Anisotropy Probe (WMAP) By Susan Creager April 20, 2006.
Motions of the Moon, Phases and Eclipses (Ch 3)
FINAL YEAR PROJECT 4SSCZ
Chapter 30 Section 4 Big Bang Theory.
Charge Transfer Efficiency of Charge Coupled Device
CCD Image Processing …okay, I’ve got a bunch of .fits files, now what?
Introduction Euclid Mission Weak Lensing Radiation damage
Investigation on tray MID 063 Back
A “Field Guide” to WFPC2 HLA Image Anomalies
Akatsuki Mission Update: New Images and Status of the Mission
FNAL Production Experience
Presentation transcript:

CCDs in space: the effects of radiation on Hubble’s Advanced Camera for Surveys (ACS) Max Mutchler, David Golimowski (Space Telescope Science Institute), Marco Sirianni (ESA / ESTEC) Photo: Astronauts John Grunsfeld and Drew Feustel during Hubble Servicing Mission 4 in May April 2002 July 2009 Figure 3: A comparison of dark images (above) obtained shortly after ACS installation in 2002, and following the repair in The brightening near the chip gap reflects the cumulative effects of hot pixel CTE tails far from the readout amps, and a horizontal striping feature from the new electronics (not a dark feature) is evident. Corresponding histograms (bottom) indicate the growing population of warm and hot pixels over this period. Figure 1: At left, th e mean dark current (e-/pix/hr/yr) over time, illustrating the effect of reducing the operating temperature from -77 C to -81 C, and the rate following the 28-month period between ACS failure and repair. At right, the same trends for the growth of hot pixels. For more, see the ACS website: Figure 2: Parallel (blue) and serial (red) CTE as measured by the EPER test at one signal level (1620e), showing post- SM4 results to be near extrapolations from January 2007 warm hot SM3B -77 C -81 C SM4 Anneal: 12 hr 6 hr 12 hr Jan 2007 June 2009 WFC1 WFC2 Introduction: The Advanced Camera for Surveys (ACS) has been continuously exposed to the space radiation environment since being installed during Hubble Servicing Mission 3B in March We have been monitoring the effects of radiation damage in the CCDs during this 7-year period. Radiation damage on-orbit leads to a continuous growth of permanent hot pixels (defined to be > 0.08 e-/s), and an increase of the mean dark current per pixel, and loss of charge transfer efficiency (CTE). We have also experimented raising the operating temperature a few degrees, and also cutting our anneal time in half, from 12 down to 6 hours at +20 C. In July 2006, coincident with the switch to the redundant side 2 electronics, the operating temperature of the CCDs was lowered from - 77 C to -81 C, which caused the dark current rate and the hot pixel contamination to be reduced by more than 50% (see Figure 1). The CTE tails are also fainter, and along with the lower hot pixel contamination, this reduced the image noise. Following the ACS failure in January 2007, the camera experienced a relatively warm 28-month period at -10 C. We summarize the more recent radiation damage history of the CCDs, with results following the on-orbit installation of the new controller electronics box (CEB-R) during Hubble Servicing Mission 4 in May 2009, and the resumption of science observations at the nominal operating temperature of -81 C. Since the ACS High Resolution Channel (HRC) was not recovered during SM4, we discuss only the two Wide Field Channel (WFC) CCDs. A report by Gilliland (2008, internal) summarized the characteristics of ACS at the time of the failure in January 2007, with extrapolations into the future as criterion for the success of the repair effort. We compare those predictions to initial post-SM4 results, and discuss what the complex thermal history of the ACS CCDs has revealed. Mean dark current: At launch in 2002, operating at -77 C with monthly 12-hour anneals the mean dark current was 7.8 e-/hour and 7.5 e-/pix/hr (for WFC1 and WFC2 respectively), and increasing at a rate of 2.1 and 1.6 e-/pix/hr/yr. When ACS failed in January 2007 we were operating at -81 C with dark current 10.7 e-/pix/hr, and at this temperature we have seen a rate of 3.1 and 3.6 e-/pix/hr/yr. Our recent post-SM4 measurement of 22.0 e-/pix/hr/yr is higher than the prediction of 15 e-/pix/hr/yr, but is not problematic. See Figure 1. Experimenting with 6-hour anneals at -77 C yielded rates of 3.8 and 3.1 e-/pix/hour/year, respectively, and after reducing the operating temperature to -81 C in July 2006, these 6-hour anneals yielded rates of 3.0 and 3.2 e-/pix/hour/year. Although on a monthly basis the anneal does not seem to have any effect on the mean dark current, reducing the length of the anneal from 12 to 6 hours clearly has a detrimental effect on the growth of dark current, so we have reverted to the longer anneals. The 28-month “annealing” at -10 C did not have a significant effect: the dark current has grown as expected based on the trend from the few months of operation at -81C in Hot pixels: Operating at -77C from launch in 2002 until July 2006, we measured a permanent hot pixel growth rate of rate of ~71 pixels/chip/day with 12-hour monthly anneals. Experimenting with 6- hour anneals produced a rate of ~105 pixels/chip/day – 40% faster! A direct comparison with the growth rate at -77 C is no longer possible because a different pixel population is involved. Operating at -81 C after July 2006 this rate decreased to ~34 pixels/chip/day until in January 2007, the fraction of the WFC covered by permanent hot pixels (those not removed in monthly anneals) was 0.68%. The fraction anticipated for May 2009 (after the first anneal) is 1.1%, and the early count is very close to prediction at 1.15%. It is too early to reliably measure the post-SM4 rate of permanent hot pixel growth. In addition to hot pixels, other evolving dark structure is evident in the comparison of dark images spanning the on-orbit life of ACS (Figure 3). The dark features visible in 2002 have faded into the rising dark current and noise. Even when we last saw ACS in 2007, the cumulative effect of the CTE tails of hot pixels was evident as a brightening towards the chip gaps (farthest from the readout amplifiers). This effect, plus a new horizontal striping feature (caused by the new electronics, not radiation damage) is evident in the 2009 post-SM4 dark. Charge transfer efficiency (CTE): The CTE as measured by Extended Pixel Edge Response (EPER) at a signal level of 1620e in January 2007 was , with an extrapolation for May 2009 of The actual EPER results measured were slightly lower than this prediction, but still above the level considered problematic (see Figure 2). The rate of CTE degradation has remained predictable, with no effects due to temperature changes, although the shape and brightness of the CTE tails is now shorter and brighter. Conclusions: The two WFC CCDs are from the same silicon wafer and they went through a similar processing, and they show a very similar CTE and hot pixel contamination -- but clearly the dark current grows at a different rate in the two chips. The first dark after the 28 month “anneal” had no temporary hot pixels, only the most damaging traps (those that do not anneal at +20 C), which have accumulated at a rate similar to the one measured at -81 C with monthly anneals, so the chip degradation has continued as we would expect if ACS had been operating during this down time.