RT 4912 Review (A) Rex T. Christensen MHA RT (R) (MR) (CT) (ARRT) CIIP.

Slides:



Advertisements
Similar presentations
Pulse Timing parameters & Weighting
Advertisements

BOLD Imaging at 7T Mark Elliott CfN Symposium 4/9/2008.
MRI Physics 2: Contrasts and Protocols
By Zach London. Goals Identify axial, sagittal, and coronal images Identify the following: –CT head without contrast –CT head with contrast –MRI brain.
Magnetic Resonance Imaging
Imaging Sequences part I
Chapter 7: Gradient Echo Imaging Methods
PULSE SEQUENCES Emphasizing the differences among spin density, T1, and T2 relaxation time constants of the tissues is the key to the exquisite contrast.
Proton Spin In absence of a magnetic field, protons spin at random
MRI Phillip W Patton, Ph.D..
Richard Wise FMRI Director +44(0)
M R I Pulse Sequences Jerry Allison Ph.D..
Leigh Vaughan, MD June 5, 2012 MUSC. Outline CT Advantages, disadvantages Modality basics Appropriate uses With or without contrast MRI Advantages, disadvantages.
BE 581 Lecture 3- Intro to MRI.
PHYSICS OF MAGNETIC RESONANCE
Richard Simmons, M.D. Child Neurologist Schenectady Neurological Consultants.
Institute for Biomedical Engineering EXCITE Afternoon Hands-On MRI Sessions: fMRI & DTI.
Magnetic Resonance Imaging - MRI
Neuroradiology Natasha Wehrli, MS4 University of Pennsylvania School of Medicine.
MR Sequences and Techniques
Fund BioImag : MRI contrast mechanisms 1.What is the mechanism of T 2 * weighted MRI ? BOLD fMRI 2.How are spin echoes generated ? 3.What are.
Neuroradiology Dr Mohamed El Safwany, MD. Intended Learning Outcomes  The student should be able to understand role of medical imaging in the evaluation.
Parameters and Trade-offs
Magnetic Resonance Imaging
Topics spatial encoding - part 2. Slice Selection  z y x 0 imaging plane    z gradient.
Equipment Magnetic resonance imaging (MRI) scan requires the use of a very strong magnetic field. Unlike other devices used in radiology, MR imaging.
Chapter 10 Lecture Mark D. Herbst, M.D., Ph.D..
Magnetic Resonance Imaging
Introduction to MRI Head Imaging
Tissue Contrast intrinsic factors –relative quantity of protons tissue proton density –relaxation properties of tissues T1 & T2 relaxation secondary factors.
Magnetic Resonance Imaging 4
대구가톨릭대학병원 영상의학과 이 영 환 M M R R Basic Physics. MR Signal T1-, T2-weighted TR, TE MR Signal T1-, T2-weighted TR, TE.
Imaging Sequences part II
The comparison of MRI imaging In 3.0 T & 1.5T By a.r.shoaie.
Pulse sequences.
Pulse Sequences Types of Pulse Sequences: Functional Techniques
Chapter 6 Lecture Spin Echo Imaging Methods Mark D. Herbst, MD, PhD Two Main Types of MR methods –Spin Echo –uses RF pulse to get an echo –Gradient Echo.
MRI DRAFT Principles of MRI ► Sectional Anatomy ► Provides anatomic and physiologic info ► Non- invasive ► No radiation  Magnetic fields and.
Contrast Mechanism and Pulse Sequences Allen W. Song Brain Imaging and Analysis Center Duke University.
DIFFUSION & PERFUSION MRI IMAGING Dr. Mohamed El Safwany, MD.
Rad T 265 MRI Lecture. No Magnetic Field = No Net Magnetization Protons align with a magnetic field…
Contrast Mechanisms in MRI Introduction to Cardiovascular Engineering Michael Jay Schillaci, PhD Managing Director, Physicist Tuesday, September 16 th,
High Resolution 3D Diffusion Pulse Sequence Dept. of Radiology Medical Imaging Research Lab. University of Utah Eun-Kee Jeong, Ph.D. Ph.D. Seong-Eun Kim,
Contrast Mechanism and Pulse Sequences
Statistical Parametric Mapping
MRI Physics Dr Mohamed El Safwany, MD.. MRI Magnetic Resonance Imaging Magnetic Resonance Imaging.
Magnetic Resonance Imaging
Basic MRI Chapter 1 Lecture. Introduction MRI uses radio waves and a magnetic field to make images MRI uses radio waves and a magnetic field to make images.
Principles of MRI magnetic resonance imaging
V.G.Wimalasena Principal School of Radiography
Neuroimaging in Neuropsychiatry
BIOE 220/RAD 220 REVIEW SESSION 3 February 6, 2011.
Magnetic Resonance Imaging (MRI). The Components: A magnet which produces a very powerful uniform magnetic field. A magnet which produces a very powerful.
RT 4912 Review (C) Rex T. Christensen MHA RT (R) (MR) (CT) (ARRT) CIIP.
MRI: Contrast Mechanisms and Pulse Sequences
Magnetic Resonance Learning Objectives
Principles of MRI Physics and Engineering Allen W. Song Brain Imaging and Analysis Center Duke University.
Comparison of T1 FLAIR and T1 FSE Images Andrew Allmendinger, DO Sylvie Destian, MD.
MAGNETIC RESONANCE IMAGING by PRADEEP V.EPAKAYAL. Mem.no L.
بسم الله الرحمن الرحيم Dr. Maged Ali Hegazy Assistant Professor Alazhar University.
Chapter 5 Mark D. Herbst, M.D., Ph.D.. The MR Imaging Process Two major functions –Acquisition of RF signals –Reconstruction of images.
Parameters which can be “optimized” Functional Contrast Image signal to noise Hemodynamic Specificity Image quality (warping, dropout) Speed Resolution.
FMRI data acquisition.
Fig year-old girl with juvenile rheumatoid arthritis
Sunday Case of the Day Physics
بسم الله الرحمن الرحيم.
Magnetic Resonance Imaging: Physical Principles
The Corpus Callosum: Imaging the Middle of the Road
Slice thickness: 5–6mm Slice gap: 20% of slice thickness (!1–1.2mm or factor 1.2) Matrix: 512 FOV: 220–240mm Saturation slab: parallel to the slices,
The echo time (TE) The echo time (TE) refers to the time between the application of the radiofrequency excitation pulse and the peak of the signal induced.
Presentation transcript:

RT 4912 Review (A) Rex T. Christensen MHA RT (R) (MR) (CT) (ARRT) CIIP

Websites: Websites:

6 Key Imaging Goals Optimize Contrast Optimize Contrast Optimize Coverage and Slice Thickness Optimize Coverage and Slice Thickness Optimize Resolution Optimize Resolution Minimize Artifacts Minimize Artifacts Maximize Patient Throughput Maximize Patient Throughput Optimize Signal to Noise (SNR) Optimize Signal to Noise (SNR)

Scenario 1 Radiologist asks for a MRCP to visualize the biliary system. Radiologist asks for a MRCP to visualize the biliary system.

Scenario 2 Radiologist wants a sagittal T2 FSE fatsat knee with better signal and better resolution. Radiologist wants a sagittal T2 FSE fatsat knee with better signal and better resolution.

Scenario 3 A coronal T1 wrist is too grainy A coronal T1 wrist is too grainy

Scenario 4 A FSE T2 fatsat brachial plexus does not get good fat saturation. A FSE T2 fatsat brachial plexus does not get good fat saturation.

Scenario 5 FSE T2 IACs have low spatial resolution FSE T2 IACs have low spatial resolution

Build a Protocol/Optimize It! Brain w/wo contrast Brain w/wo contrast Routine knee Routine knee Routine L-spine Routine L-spine

Advantages/Disadvantages Changing FOV Changing FOV Changing Slice Thickness Changing Slice Thickness Changing ETL Changing ETL Changing NSA/NEX Changing NSA/NEX Changing TE Changing TE Changing Bandwidth Changing Bandwidth Changing TR Changing TR

If this…..then this….. P. 136 and P.137 MRI in Practice P. 136 and P.137 MRI in Practice

I have a question?

Student Questions

1. Higher magnetic field strength is generally associated with which item listed? 1. Higher magnetic field strength is generally associated with which item listed? a. decreased T2 b. higher SNR c. less scan time d. increased spatial resolution d. all of the above correct answer B correct answer B

2. What is the advantage of using partial flip angles in gradient echo pulse sequence? 2. What is the advantage of using partial flip angles in gradient echo pulse sequence? a. A "steady state" is established in which most of the tissue magnetization remains longitudinal. b. It increase MR signal intensity. c. Very short TR's can be used d. both a and c e. none of the above correct answer is D correct answer is D

Steady State Shorter TR than a T1 or T2 sequence. There is no time for transverse magnetization to decay before the next pulse sequence. Flip angles of 30 to 45 degrees and a TR less than 50 ms. Shorter TR than a T1 or T2 sequence. There is no time for transverse magnetization to decay before the next pulse sequence. Flip angles of 30 to 45 degrees and a TR less than 50 ms.

Gradient Echo T1 gradient echo – T1 times of tissues maximized and T2 times of tissues minimized T1 gradient echo – T1 times of tissues maximized and T2 times of tissues minimized larger flip angle to avoid longitudinal recovery of fat and water. larger flip angle to avoid longitudinal recovery of fat and water. T2 gradient echo – smaller flip angle to – T2 times of tissues maximized and T1 times of tissues minimized T2 gradient echo – smaller flip angle to – T2 times of tissues maximized and T1 times of tissues minimized Smaller flip angle allows longitudinal recovery Smaller flip angle allows longitudinal recovery

3. Which of the following results from an increase in the number of averages of an MRI scan? 3. Which of the following results from an increase in the number of averages of an MRI scan? a. decreased scan time b. increased SNR c. increased artifact d. increase spatial resolution e. decreased spatial resolution correct answer is B correct answer is B

4. T2-weighted images are perfomed with: 4. T2-weighted images are perfomed with: a. short TE and short TR b. short TE and long TR c. long TE and long TR d. TE equals TR e. none of the above correct answer is C correct answer is C

5. If the technologist decreases the field of view it will: 5. If the technologist decreases the field of view it will: a. results in an image that depicts more area b. improves spatial resolution c. increase Signal to noise ratio d. increases T1 weighting e. both B and D correct answer is B correct answer is B

6. On single slice gradient echo images, rapidly flowing blood appears: 6. On single slice gradient echo images, rapidly flowing blood appears: a. dark b. bright c. dark or bright d. depends on the vessel e. both dark and bright correct answer is B correct answer is B

Nursing mothers should suspend breast feeding for up to ___ hours after an MRI exam with contrast. Nursing mothers should suspend breast feeding for up to ___ hours after an MRI exam with contrast. a. 12 b. 24 c. 24 ‑ 30 d. 36 ‑ 48 answer: d answer: d

The distance that the 5 Gauss line stands from the isocenter of the magnet is: The distance that the 5 Gauss line stands from the isocenter of the magnet is: a. 5ft b. dependent upon the field strength of the magnet c. dependent upon the field strength, geometry, and type of shielding of the magnet. d. dependent only upon the magnet and shielding answer: c answer: c

The Unit of measure for RF absorption is: The Unit of measure for RF absorption is: a. Volts per pound b. amps per liter c. watts per kilogram d. volts per Tesla Answer: C Answer: C

Contraindications for an MRI exam include: Contraindications for an MRI exam include: 1. Cardiac pacemaker 2. ferromagnetic aneurysm clips 3. renal failure a. 1 only b. 2 only c. 1 and 2 d. 1 and 3 answer c answer c

A joint effusion of the left knee would appear as what on a T2 weighted scan? a. a. Dark area around the joint b. b. Unremarkable c. c. Bright area around the joint d. d. Similar signal with the surrounding soft tissue Answer: C

Inversion recovery sequences are primarily used to identify a. a. Pathology b. b. Anatomy c. c. Multiple sclerosis plaques d. d. Fluid Answer: C

Gadolinium contrast shortens which imaging sequence a. a. T2 b. b. IR c. c. T1 d. d. FLAIR Answer: C

What scanning sequence is used to evaluate for strokes? a. a. T2* b. b. FLAIR c. c. Diffusion Weighted Imaging d. d. T1 Answer: C

What plane would be used to see the corpus callosum in profile? a. a. Transverse b. b. Coronal c. c. Sagittal d. d. Oblique Answer: C

How will freely diffusing water appear on a DWI scan? a. a. Isointense b. b. Bright c. c. Dark

ADC – Apparent Diffusion Coefficient ADC – Apparent Diffusion Coefficient Restricted diffusion = low ADC (dark) Restricted diffusion = low ADC (dark) Unrestricted diffusion = high ADC (same as trace image) Unrestricted diffusion = high ADC (same as trace image) Trace image Trace image Restricted diffusion = bright Restricted diffusion = bright Unrestricted diffusion = no change Unrestricted diffusion = no change

What is the fringe field distance of 1.5 T magnet? a. a. 2 Gauss b. b. 5 Gauss c. c. 7 Gauss d. d. 1.5 Gauss Answer: B

On a FLAIR or T2 weighted sequence a subdural hematoma will appear a. a. Hypointense b. b. Isointense c. c. Hyperintense

References: Westbrook, Catherine and Kaut, Carolyn (1998). MRI In Practice, 3rd Edition, Malden, MA: Blackwell Science, Inc.