Continue The information provided in this training module covers the schematic flow charts for all ovens and ranges that utilized a preheat board, Self.

Slides:



Advertisements
Similar presentations
Sequential Process Control
Advertisements

SWITCHES, FUSES, & CIRCUIT BREAKERS
Programming with Ladder Logic
Schematics On or off Batteries Series or Parallel Volts and Amps FJ
E1 – Electrical Fundamentals
Thermostats. I would recommend that as you proceed through this power point presentation that you refer to your textbook, Unit 14, for some great visuals.
WebStat™ Programming and Configuration of Thermostats.
7.3.3 Student Book © 2005 Propane Education & Research CouncilPage Identifying the Components & Operating Characteristics of Wall Thermostats (Heat.
HVAC Commercial Ref.
38GXC(Q)/40GXC(Q) Service Training Sizes 18 and 24K.
Heating Control Devices
In this presentation you will:
Dishwasher Rework. Identify Unit Disconnect Power Turn off Breaker… … or unplug power cord.
HVAC121 – Gas Heat Flame Rectification.
Gas Furnace Controls Part 4.
Ladder Logic PLC Programs are made up of combinations of AND; OR; NAND; NOR; and other gates, along with timers, inputs, outputs, counters, comparators,
Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams
Logic Operations in Electro-Pneumatics
Section 4: Electric Motors
E2 Motors and Motor Starting
Electrical Electricity Fuses Relays Solenoids Electrical Testing
Student Handout Packet Go to page A4. Please answer the following questions using page A4.
Abs.
1 HVAC 214 Electricity For Oil Heat Fan Center Relays.
Fan Switch and Limit Switch Information. FAN Switch.
Troubleshooting Electric Control Devices
On/Off Temp Holiday Select Fan Air clean Operation Auto SwingRoom Temp Week Select SET/CLR Hour MIN Timer Program Set Fan Speed Jet Cool Cancel RESET E_Heater.
HYDRONIC HEATING AQUASTATS
 Four Components of a circuit  Power supply  Conductor  Load device  Controlling device  Power Supply  Generator  Line source (wall outlet)  Transformer.
Operation Sabbath Mode - SELECT PROGRAM - Lights, alarms and fans Normal Sabbath Overview.
Memory Layout and SLC500 System Addresses. Processor Memory Division An SLC 500 processor's memory is divided into two storage areas. Like two drawers.
BAKE BROIL - SELECT PROGRAM - CONV BAKE CONV BROIL SELF CLEAN On any diagram screen, double click any of the following components to bring you to a description.
Introduction to Defrost
TECHNICAL TRAINING INVERTER-Y
Continue FCU150 Trash Compactor. Normal ModeDelay Mode.
PHSAUTOMOTIVESALSPHSAUTOMOTIVESALS Electric Cooling Fans.
A6a to A6b Schematic Diagram to Pictorial Diagram
G15 This power point presentation is designed to assist the student in understanding the relationship of the fan and limit switch to the fan relay, when.
Symbols and Schematic Diagrams
Last updated: 6/6/2016www.alto-shaam.com Halo Heat Training Cook & Hold OvensHolding Cabinets.
CHAPTER 17: ELECTRICITY ELECTRIC CHARGE AND FORCE CHAPTER 17: ELECTRICITY.
HOUSE WIRING Final Review. Electricity Electricity = flow of electrons Conductor= electricity passes thru easily - Metal, water, person Insulator = restricts.
BASIC AUTOMATIC CONTROLS UNIT 16 ADVANCED AUTOMATIC CONTROLS
NN-CS596S Steam Microwave Oven. NN-CS596S Oven Specification.
Control Systems: Circuitry Electricity for Refrigeration, Heating and Air Conditioning 7th Edition Chapter 16 Control Systems: Circuitry and Troubleshooting.
We apply 120 VAC to the HM Unit (Remember to check polarity!) Our primary step down T/X provides power to terminal “X” and “COM” on the ignition control.
All Freezer Advance. When the Freezer is first supplied with power or if a power outage occurs, the display will indicate this by flashing the temperature.
BASIC ELECTRICITY AND MAGNETISM
Last updated: 6/28/2016www.alto-shaam.com Rotisserie Training Rotisserie.
Push Button Station and Relay
E3 HVACR Controls and Devices
E3 HVACR Controls and Devices
PLC Hardware Components.
Lesson 14: Introduction To Sequential Control
ET 438B Sequential Control and Data Acquisition
Workbook Section.
K1 Schematic Analysis and Pictorial Diagram
Solstice All Options Gas Fired Fryer Service Presentation (CE-UK)
Presentation transcript:

Continue The information provided in this training module covers the schematic flow charts for all ovens and ranges that utilized a preheat board, Self Clean timer and mechanical relays. There were different variations of this design. The following information covers the majority of those models. NOTE: The information provided is subject to change without notice. Viking Range Corporation – May 2008

Start Please note that if you move the cursor over any of the components listed below during this presentation you will open a viewing window on that component. When open, you will see a photo of the component along with a drawing of each part, wire colors, numbers and the termination points of each wire Parts available for viewing: R1 relay R2 relay R3 relay Selector Switch Self Clean Timer Preheat Board

Select a program below CONV BAKE CONV BAKE CONV COOK CONV COOK BAKE MAX BROIL MAX BROIL CONV BROIL CONV BROIL SELF CLEAN SELF CLEAN

ADVANCE

The selector is set to the BAKE cycle.

The thermostat is turned “ON” to the desired temperature.

L1 Power flows first through the High Limiter, then through the operating thermostat, through the R3 and R2 relays to the R1 relay coil. Both the L1 and L2 power flow to the elements through the R1 relay.

The R1 relay closes and the cycle light is illuminated.

L1 Power flows to the Bake Element and the Inner Broil Element.

L1 Power flows to the preheat board Sensor 2. AT4 is post high limit and pre-operating thermostat while AT3 is post operating thermostat.

L2 Power flows from the R1 relay to terminal L2 on the selector. Through the switch to terminal #1 on the selector and then into the BAKE element. The BAKE element 11.5 amps.

L2 Power also flows to Sensor 1 – AT6 on the preheat board. It is wired parallel to the BAKE element while AT2 is wired parallel to the L2 connection on the selector switch. Both are cycled through the R1 relay.

This slide shows the NEUTRAL connections to the preheat board. Notice that the NEUTRAL line is connected to AT15 which is the N.C. contact on Relay K4 on the preheat board. This will be explained later.

This slide shows both the K3 and K4 relays closed on the preheat board.

This slide shows the L2 power flow through AT 14, the N.O. terminal on the K3 relay – through AT 13 (the common terminal) and supply L2 power to both the Outer Broil element and the Inner Broil element. The Inner Broil element 5.20 amps.

This slide shows the L1 power flow from terminal #4 on the selector switch to AT17, the N.O. terminal on K4 on the preheat board. From AT 16 (Common terminal) to the Outer Broil element. The Outer Broil element 7.30 amps. Total amps on PREHEAT: 24 AMPS.

When the oven has reached its set temperature, the power is pulled away from the R1 relay. L1 and L2 power is removed from all three heating elements. The preheat board has sensed that the oven has cycled off so it disengages the K3 and K4 relays. We now have a NEUTRAL connection to the Outer Broil element.

When the oven has cooled, the oven thermostat will close. The R1 relay closes L1 power flows to the Bake and Outer Broil elements. L2 flows through the selector to the Bake element which draws 11.5 amps.

The preheat Board does not activate the K3 and K4 relays. We now have Neutral flowing through the K4 relay to AT 16 then to the Outer Broil element. Because selector switch contact 3 and E are closed, the Inner and Outer broil elements are in series. At 120 volts – they will draw 1.5 amps. Total amps on COOK: 13 AMPS

ADVANCE

The selector is set to the CONV BAKE cycle.

The thermostat is turned “ON” to the desired temperature.

L1 Power flows first through the High Limiter, then through the operating thermostat, through the R3 and R2 relays to the R1 relay coil. Both the L1 and L2 power flow to the elements through the R1 relay.

The R1 relay closes and the cycle light is illuminated.

L1 Power flows to the Bake Element and the Inner Broil Element. L1 also flows through Selector contact # 6 and contact # I to the convection fan motor.

L1 Power flows to the preheat board Sensor 2. AT4 is post high limit and pre-operating thermostat while AT3 is post operating thermostat.

L2 Power flows from the R1 relay to terminal L2 on the selector. Through the switch to terminal #1 on selector. Power flows into the BAKE element. The BAKE element 11.5 amps.

L2 Power also flows to Sensor 1 – AT6 on the preheat board. It is wired parallel to the BAKE element while AT2 is wired parallel to the L2 connection on the selector switch. Both are cycled through the R1 relay.

This slide shows the NEUTRAL connections to the preheat board. Notice that the NEUTRAL line is connected to AT15 which is the N.C. contact on Relay K4 on the preheat board. This will be explained later.

This slide shows both the K3 and K4 relays closed on the preheat board.

This slide shows the L2 power flow through AT 14, the N.O. terminal on the K3 relay – through AT 13 (the common terminal) and supply L2 power to both the Outer Broil element and the Inner Broil element. The Inner Broil element 5.20 amps.

This slide shows the L1 power flow from terminal #4 on the selector switch to AT17, the N.O. terminal on K4 on the preheat board. From AT 16 (Common terminal) to the Outer Broil element. The Outer Broil element 7.30 amps. Total amps on PREHEAT: 24 AMPS.

When the oven has reached its set temperature, the power is pulled away from the R1 relay. L1 and L2 power is removed from all three heating elements. The preheat board has sensed that the oven has cycled off so it disengages the K3 and K4 relays. We now have a NEUTRAL connection to the Outer Broil element. The Convection fan continues to run.

When the oven has cooled, the oven thermostat will close. The R1 relay closes L1 power flows to the Bake and Outer Broil elements. L2 flows through the selector to the Bake element which draws 11.5 amps.

The preheat Board does not activate the K3 and K4 relays. We now have Neutral flowing through the K4 relay to AT 16 then to the Outer Broil element. Because selector switch contact 3 and E are closed, the Inner and Outer broil elements are in series. At 120 volts – they will draw 1.5 amps. Total amps on COOK: 13 AMPS

ADVANCE

The selector is set to the CONV COOK cycle.

The thermostat is turned “ON” to the desired temperature.

L1 Power flows first through the High Limiter, then through the operating thermostat, through the R3 and R2 relays to the R1 relay coil. Both the L1 and L2 power flow to the elements through the R1 relay.

The R1 relay closes and the cycle light is illuminated.

L1 Power flows to the Convection Element. L1 also flows through Selector contact # 6 and contact # I to the convection fan motor.

L2 Power flows from the R1 relay to terminal L2 on the selector. Through the switch to terminal #5 on selector. Power flows into the CONVECTION element. The Convection element 9.2 amps.

ADVANCE

The selector is set to the BROIL cycle.

The thermostat is turned “ON” to the Broil setting.

L1 Power flows first through the High Limiter, then through the operating thermostat, through the R3 and R2 relays to the R1 relay coil. Both the L1 and L2 power flow to the elements through the R1 relay.

The R1 relay closes and the cycle light is illuminated.

L1 Power flows to the Inner Broil Element..

L2 Power flows from the R1 relay to terminal L2 on the selector. Through the switch to terminal #3 on selector. Power flows into the INNER BROIL element. The Inner Broil element 5.2 amps.

ADVANCE

The selector is set to the MAX BROIL cycle.

The thermostat is turned “ON” to the Broil setting.

L1 Power flows first through the High Limiter, then through the operating thermostat, through the R3 and R2 relays to the R1 relay coil. Both the L1 and L2 power flow to the elements through the R1 relay.

The R1 relay closes and the cycle light is illuminated.

L1 Power flows to the Inner Broil Element. We also have F1 power flowing through terminal # 4 to terminal F in the selector. It then flows through AT 12 - the N.C. contact in the K3 relay on the preheat board (inactive in Max Broil). Through AT 13 to the Outer Broil element.

L2 Power flows from the R1 relay to terminal L2 on the selector. Through the switch to terminal #3 on selector. Power flows into the INNER BROIL element. The Inner Broil element 5.2 amps.

At the same time, L2 power also flows through the L2 terminal on the selector to terminal # 2. Power then flows through AT 15 - the N.C. contact in the K4 relay on the preheat board (inactive in Max Broil). Through AT 16 to the outer broil element. The Outer Broil element 7.3 amps. Total on Max Broil: 12.5 AMPS

ADVANCE

The selector is set to the CONV BROIL cycle.

The thermostat is turned “ON” to the Broil setting.

L1 Power flows first through the High Limiter, then through the operating thermostat, through the R3 and R2 relays to the R1 relay coil. Both the L1 and L2 power flow to the elements through the R1 relay.

The R1 relay closes and the cycle light is illuminated. L1 also flows through Selector contact # 6 and contact # I to the convection fan motor. The fan motor continues to run throughout the Convection Broil program.

L1 Power flows to the Inner Broil Element. We also have F1 power flowing through terminal # 4 to terminal F in the selector. It then flows through AT 12 - the N.C. contact in the K3 relay on the preheat board (inactive in Max Broil). Through AT 13 to the Outer Broil element.

L2 Power flows from the R1 relay to terminal L2 on the selector. Through the switch to terminal #3 on selector. Power flows into the INNER BROIL element. The Inner Broil element 5.2 amps.

At the same time, L2 power also flows through the L2 terminal on the selector to terminal # 2. Power then flows through AT 15 - the N.C. contact in the K4 relay on the preheat board (inactive in Max Broil). Through AT 16 to the outer broil element. The Outer Broil element 7.3 amps. Total on Conv Broil: 12.5 AMPS

ADVANCE

The selector is set to the SELF CLEAN cycle.

The thermostat is turned “ON” to the CLEAN setting. MS1 and MS2 close in the operating thermostat.

L2 power flows through the thermostat to the R3 relay coil.

The R3 relay coil energizes. As long as the thermostat is in the CLEAN cycle, the R3 relay will remain closed.

With the R3 relay energized, L1 power flows though the thermostat – then through the R3 relay coil – then to the SW3 contact on the door latch assembly. This will be the power supply to the R1 relay. This circuit will be explained in detail later.

With the selector switch in the CLEAN position, L1 power flows through terminal # 6 and terminal J in the selector switch, then to the R2 relay coil.

The R2 coil engages. We now have the R2 coil (L1-N) and the R3 coil (L2-N) closed.

L1 power also branches off the R2 coil – travels through the closed contact in the R3 relay, then flows to the both the Clean Light and SEL contact in the Self Clean timer. The Self Clean timer is now activated. NOTE: The clean light illuminated indicates that L1 power is present at the Self Clean timer.

The LS1 and LS2 contacts in the self clean timer now close.

With the LS1 and LS2 contacts closed, L1 power flows through LS1 – then through the auto reset N.C. contact #1 and #3. It then flows through the LS2 –then to the lock motor. The lock motor begins to lock the door.

When the door motor has locked the door, SW2 and SW3 in the door lock are now closed. SW2 sends a return signal from VG on the Self Clean timer to SENSOR 3, signaling that the door has locked.

With the door now locked, the Self Clean timer has opened the LS2 contact, stopping the power to the lock motor.

The Self Clean timer now closes contacts T1 and T2 and T3 and T4. These circuits will control the cooling fan (T3-T4) and the R1 relay (T1-T2).

L2 power flows through the T3-T4 contact in the self clean timer. The power by-passes the fan thermostat - then flows into the cooling fan.

With the door locked, the self clean cycle is ready to begin. Starting at the operating thermostat – L1 flows through the N.O. contact in the R3 coil – then to the SW3 contact in the door lock assembly. From there, it flows through T1-T2 in the Self clean timer then travels back to the N.O. contact in the R2 relay and finally ends up at the coil of the R1 relay.

The R1 coil now closes and the cycle light is activated. With the CLEAN light on, it is a good indication that the Selector, Thermostat,R2 and R3 relays are all functioning properly. The CYCLE light lets you know that the R2 and R3 relays are closed and that the T1-T2 (Self Clean timer) and the SW3 in the door lock assembly are also functioning properly.

With the R1 relay energized, L1 power flows to the Bake Element and Inner Broil element. With terminal # 4 and F closed in the selector – L1 power also flows through the K3 relay on the preheat board (Deactivated in Self Clean) and then to the Outer Broil element.

L2 power flows through the R1 relay to terminal L2 and # 3 in the selector switch to the Inner Broil element. The Inner Broil element draws 7.3 AMPS

At the same time, L2 power flows through terminal L2 and # 2 in the selector switch – Through the K4 relay in the preheat board, then to the Outer Broil. The Outer Broil draws 5.2 amps. Total of 12.5 AMPS on the broil elements.

As shown on the last slide, the oven heats during Self Clean by using both the Inner and Outer broil elements. The bake element is also utilized during the self clean process. It is operated on 120 volts. This is achieved by the selector switch channeling the NEUTRAL to the element through terminal N and # 1 on the selector. The Bake element will draw 5.75 AMPS. Total amps on Self Clean: AMPS

During the Self Clean Cycle, when the oven temperature reaches 575 º F, the Auto Reset will trip and open contacts #1 and #2. This will prevent the door motor from opening if the oven temp is too hot.

When the cabinet temperature has reached 230ºF, the Cooling Fan thermostat will close to the cooling fan motor. The fan will continue to run until the cabinet cools below 230ºF.

When the internal temperature has reached 825ºF, the control thermostat will open. We now has removed our L1 circuit through R3 – SW3 (Door Lock) – T2-T3 (Self Clean timer) –Back through the N.O. contact in the R2 relay. The cooling fan continues to run. This process will repeat for 3.5 hours when the Self Clean cycle has completed.

At the end of the Self Clean cycle, the Self Clean Timer will once again close LS1 and LS2. The Door will remained locked until the Auto Reset closes.

When the Auto Reset resets between contacts #1 and #2, L1 Power flows through LS1 - then the Auto Reset – Then through LS2 to the lock Motor. The lock motor turns to unlock the door.

When the door motor has unlocked the door, SW2 and SW3 in the door lock are now open. SW1 sends a return signal from VG on the Self Clean timer to SENSOR 4 signaling that the door has un- locked.

With the door open signal sent to the Self Clean timer, contacts LS1 and LS2 are opened. The cooling fan will cycle off when the fan thermostat opens. Advancing the operating Thermostat to OFF will disengage the R3 relay while advancing the selector to OFF will disengage the R2.

ADVANCE

Old Style Return R1 RELAY

8 Position selector Return

Old Style A B N.C. N.O. C R2 – RELAY Return

Old Style A B N.C. N.O. C R3 – RELAY Return

Old Style A B N.C. N.O. C R2 – R3 RELAY R2 – RELAY R3 – RELAY Return

Old Style M1 LS1 M1 LS1 SENSE 3 SENSE 3 N SENSE 4 SENSE 4 VC LS2 SEL L1 Self Clean timer Return

Old Style K3 K4 AT 8 AT 2 AT 14 AT 12 AT 13 AT 16 AT 17 AT 15 AT 11 AT 10 AT 1 AT 7 AT 5 AT 9 AT 4 AT 3 AT 6 Preheat board Return