XS26-2 Expandable Safety Controller.

Slides:



Advertisements
Similar presentations
Module 3 Configuring Hardware on a Computer Running Windows XP Professional.
Advertisements

Model W Wall Mount Static Transfer Switch. Why choose a model W static transfer switch? Increases power availability. Integrated maintenance bypass. True.
Unit 7 Discrete Controllers
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
1. 2 LabVIEW for FRC Doug Norman National Instruments January 6, 2012.
MCS-Connect Intro to Connect Connection and Setup Display Menus Graphics Uses in troubleshooting Overview.
Projector Controllers
EZ-SCREEN ® LP with Integral Muting. Introduction ■ No “third box” muting controller required –Simple design & lower installed cost ■ Many of the same.
Delta Confidential Apr GAIA-series 5-11KVA Introduction.
1. 2 FRC 2010 Driver Station Doug Norman & Stephanie Brierty National Instruments January 8, 2010 Thanks to Joe Ross – Team 330.
Material Handling Modules Configuring Your Own Work Cells.
Remote Monitoring and Management Solutions ®
Checker 200 Series Training Presentation. CONFIDENTIAL The Checker 200 Series Versatile, multicolor lighting provides high contrast Small: 67x36x70 mm.
Programmable Logic Controllers Mary Holleboom ENGR 315 Dec. 5, 2001.
ConneXium Network Manager
AS-i, The Simplest Automation Networking Solution Dated: 10/30/2008.
CheckMeter 2.3 Portable Working Standard Page 1 March 2009.
MUST HAVE SHOULD HAVE COULD HAVE Module # 010. Qi Hardware Objectives Recognize hardware Know how to interface to field equipment Know the 4 different.
ME 411/511Prof. Sailor Data Acquisition & LabView Lecture goals… –Learn the basics of how to use and modify LabView Virtual Instruments –Become familiar.
Advantys® STB High Density Discrete I/O Modules. AGP - English 2 Advantys® STB Advantys STB delivers customer value in distributed I/O Smart Built-in.
PLC: Programmable Logical Controller
All content in this presentation is protected – © 2008 American Power Conversion Corporation Symmetra ® LX – redundant UPS High performance, redundant.
© Reference New safety system for Arc Welding products and systems.
Drivers Station 2010 Joe Ross Team /12/2009.
Driver Station MVRT 2009 – 2010 Season. Add information Breadboard Classmate PC USB Hub Joysticks Stop Button.
TRANSMILLE PATs The New Alternative To Fast, Easy & Efficient Portable Appliance Testing.
Operator Panel and Programmable Logic Controller.
NetVuze Precision Network Meter standalone, easy to use, networked with data logging.
PLC introduction1 Discrete Event Control Concept Representation DEC controller design DEC controller implementation.
PLC: Programmable Logical Controller
Schutzvermerk nach DIN 34 beachten XC200 Hardware Overview.
Eclipse EHX System Logic Maestro. Module Objective Introduce Logic Maestro to the user Elements ► What is Logic Maestro ► How does Logic Maestro relate.
IND131/331 Process Weighing Terminal. Internal usage only 1 Process Terminal Portfolio - Opportunity  Process Prices Performance IND110 IND560 IND780.
Cisco Router Hardware Software overview. In this lecture we will investigate an overview of Cisco router hardware and software. We will first turn our.
Product range/ALPHA-E-0001-tri-20/04/03 ALPHA Micro Controllers A single multi-functional unit instead of multiple components ALPHA / ALPHA XL Products/ALPHA.
Forging new generations of engineers
Hardware Training Product: ITMS2.
TECHNICAL TRAINING SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB.
Logic Functions and Symbols
Prepared by: Engr. Qurban Ali Memon 11ES (SEC- 1 & 2)
Quick guide to ASIMON configuration For version 3.0 or greater SAFETY AT WORK Date: 3/18/2009.
Ethernet I/O Set-Up This presentation will step through a typical configuration of the CON-DVT-IOE. Intellect 1.5 is used for the software portion. NEXT.
CheckMeter 2.1 Portable Working Standard Page 1 March 2009.
New product introduction:
Ethernet I/O Set-Up This presentation will step through a typical configuration of the DVT CON-IOE. Intellect 1.0 is used for the software portion.
Multifunctional LCD Panel HDL-MPL8.48. LCD Panel Description The HDL-MPL8.48 series is a new generation of wall mounted switch, with a total of 8 metal.
Teaching Digital Logic courses with Altera Technology
Introduction to EV3. Many Different Types of Robots Snake Robot.
PROGRAMMABLE LOGIC CONTROLLER. Control Systems Types  Programmable Logic Controllers  Distributed Control System  PC- Based Controls.
Start of Sales MSI-XXXB Safety Relays Plugable screw or spring-cage terminal blocks.
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. PUBLIC PUBLIC CO900H L16 - Features for Improving Efficiency FactoryTalk® View Machine.
CompactLogix Controllers Portfolio
Programmable Logic Controller
1 Comparison of 100-B and 100-D Contactors B Contactors.
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. PUBLIC PUBLIC CO900H L06 - Developing Safety Applications Using the Guardmaster®
Lesson 1 PLC BASICS. PLC Definition  Programmable Logic Controllers are industrial computers that control machine and other applications.  PLC have.
Software Configurable Safety Relay
ControlLogix Portfolio
ControlLogix 5580 Controller
SLS 518 Single Beam Safety Light Barrier Type 4
Conveyor Belt Production Line
Compact GuardLogix 5370 Controller
Crouzet touch Quick start.
fischertechnik® RoboPro Software for Gateway To Technology® RoboPro
Graphite® Control Platform
ACOE347 – Data Acquisition and Automation Systems
Detailed information FOR INTERNAL USE ONLY! CUBE20.
Project Migration / Management
Presentation transcript:

XS26-2 Expandable Safety Controller

XS26-2 Introduction Overview Product benefits Physical platform I/O Programming Software Application example Pricing

XS26-2 Overview The XS26-2 provides a simple and flexible safety solution for machine safeguarding Excellent alternative for multiple safety relay module applications or when a safety PLC is excessive and too costly Scalable Up to 8 expansion I/O modules can be added 6 modules to choose from Meets safety Category 4 Performance Level (PL) e

Product Benefits Easy To Use Intuitive programming environment Preconfigured safety function blocks Familiar device icons Real time feedback Live display & Ethernet

Product Benefits Flexible Interfaces with a wide selection of safety devices Designed to support a variety of safety input properties Several Logic and Function Blocks to customize safety design Configurable attributes for safety devices, logic blocks, and outputs

Product Benefits Efficient Combines the function of multiple safety relay modules Reduces wiring Reduces the space required in the control panel No dedicated status outputs wasting terminals: Inputs can be configured as outputs only when needed No feedback jumper wires required: Outputs can be referenced as Inputs

XS26-2 Expandable Safety Controller Ethernet Port (option) Screw Terminals Included (spring clamp optional) Micro USB Programming Port Status Indicators Onboard Interface Push Buttons (option) Display (option) Expansion I/O Modules Base Controller

The Physical Platform Expandable Safety Controller Dimensions: 45 mm x 110.1 X 128.5 (W x L x H) Environmental ratings: NEMA 1; IP20 Power: 24 V dc +/- 20%, 100 mA exclusive of load USB Micro B connection for programming and XM memory card* Status Indication LCD display option Diagnostics & status * Display Version Only

The Physical Platform Controller I/O 26 Inputs 8 convertible for 24 V dc or status outputs (rated at 80 mA) Removable screw terminals or cage clamp option 2 Dual-Channel Safety Outputs 500 mA Splittable for a single-channel safety output or status output Industrial Ethernet Option 64 virtual outputs Auto populated or customizable

Expandable Controllers & I/O Modules Model Description Housing Inputs/Convertible Safety Outputs XS26-2, e, d, de Base Controllers with Ethernet and Display Options 45 mm 26/8 2 Dual Channel PNP 0.5 A @ 24V dc XS8si Safety Input Module 22.5 mm 8/2 NA XS16si 16/4 XS2so Safety Output Module 2 Dual Channel PNP .75 A @ 24V dc XS4so 4 Dual Channel PNP .5 A @ 24V dc XS1ro Safety Relay Output Module 2 NO: 6A 250 V ac/dc 1 NC: 2.5A 150 V ac/dc XS2ro 4 NO: 6A 250 V ac/dc 2 NC: 2.5A 150 V ac/dc

OR Downloading Options SC-XMP2 SC-XM2 NOTE: Display Version Only SC-USB2

Programming Environment Opens in the Equipment Tab Inputs/Outputs Add Devices and Status Outputs Add I/O Modules Select Devices

Device Options Supported I/O: E-stop buttons Gate switches Safety light screens Two-hand control Non-safety devices Safety points & grids Safety mats/edges Enabling pendants Muting sensors Bypass switches Status outputs

Programming Environment Functional View Tab Inputs Flow Outputs Check List Click to add Functions Properties Window

Function Options Logic Blocks Function Blocks Split Outputs

Programming Environment Wiring Diagram Tab Page # Unused Terminals Inputs I/O Terminals Module Outputs

Programming Environment Ladder Logic Tab

Programming Environment Configuration Summary Tab

Programming Environment Live Display Run Time From XS26-2 Power-up Status Green = ON/Functional Red = OFF Amber = Fault Fault Codes NOTE: Active in Equipment, Functional and Wiring Views

Application Example ̶ Semi-Automated Assembly Line

Hypothetical Application Example 9 Hazardous Motions 5 Zones 5 Conveyor Segments 1 Press 1 Robot 1 Box Delivery System Safety Devices 10 E-stops 9 Gates 1 Two-Hand Control 1 Area Laser Scanner 2 Light Curtains (1 with exit muting) XS26-2 Hardware 1 XS26-2de Controller 2 XS16si 1 XS8si 5 XS2ro

Hypothetical Application Example Zone 5 Zone 4 Zone 3 Zone 1 Zone 2

Application Example ̶ Equipment View Still Room To Grow Note Series Connections

Application Example ̶ Functional View – Multiple Pages

Expandable Controllers & Modules Model Description List Price XS26-2 Base Controller $695 XS26-2d Base Controller with LCD $745 XS26-2e Base Controller with Ethernet $845 XS26-2de Base Controller with Ethernet and LCD $895 XS8si 8 Pin Safety Input Module (2 convertible) $235 XS16si 16 Pin Safety Input Module (4 convertible) $295 XS2so Safety Output Module (2 x Dual Channel PNP) XS4so Safety Output Module (4 x Dual Channel PNP) $315 XS1ro Safety Relay Output Module (2 NO / 1 NC) $265 XS2ro Safety Relay Output Module (4 NO / 2 NC) $375 NOTE: All models come with screw terminals.

Accessories Model Description List Price SC-XM2 XM Memory Card $13 SC-XMP2 XM Programming Tool $60 SC-USB2 USB Programming Cable $7 SC-TS2 Screw Terminal Block Set $30 SC-TC2 Spring Terminal Block Set $100 DIN-SC DIN Rail Screw Clamp $5 90443 Resource CD $4

Thank You