«BE-RF-PM» Updates on thermal tests for CLIC prototype module type 0 Ioannis Kossyvakis, Roberto Mondello, Fabrizio Rossi
«BE-RF-PM» 2 2 Contents 1.Thermal test program 2.Position of temperature sensors 3.Data acquisition and LabVIEW software 4.Data analysis
«BE-RF-PM» 3 3 Thermal test program STEP# INPUT OUTPUT T amb (°C)v air (m/s) Heat power (%) T i,water (°C) T o,water (°C) SASAS LoadPETSRFN LoadDBQSAS (+10 °C)PETS (+15 °C) WPS system (study influence of vibrations induced by air speed on WPS measuring system) Temperature sensors 2.Alignment Temperature sensors 2.Alignment Temperature sensors 2.Alignment Temperature sensors 2.Alignment
«BE-RF-PM» 4 4 Temperature sensors : SAS #1 + CL TS1 TS2TS3TS4TS5TS6 TS7 TS29.C TS29.ATS29.B TS29.D Thermocouples type J Material: Fe/CuNi Accuracy = ± 1.5 °C RTD sensor PT 100 (4-wire resistance) Accuracy = ± 0.1 °C
«BE-RF-PM» 5 5 Temperature sensors : SAS #2 + CL TS8 TS9 TS10 TS30.C TS30.ATS30.B TS30.D Thermocouples type J Material: Fe/CuNi Accuracy = ± 1.5 °C RTD sensor PT 100 (4-wire resistance) Accuracy = ± 0.1 °C
«BE-RF-PM» 6 6 Temperature sensors : PETS + RF NETWORK + CL TS23 TS17 TS18 TS19 TS20 TS21 TS22 TS24 TS25 TS26 TS36 TS35 TS34 TS33 RTD sensor PT 100 (4-wire resistance) Accuracy = ± 0.1 °C Thermocouples type J Material: Fe/CuNi Accuracy = ± 1.5 °C
«BE-RF-PM» 7 7 Temperature sensors : DBQ TS27 TS28 RTD sensor PT 100 (4-wire resistance) Accuracy = ± 0.1 °C
«BE-RF-PM» 8 8 Temperature sensors : air temperature TS39 TS41 TS38 TS40 TS TS43 TS45 TS44 TS38 TS40 TS39 TS48 TS50 TS49 AIR TEMPERATURE AROUND TM0 3 cross sections 5 thermocouples type T for each cross section Thermocouples type T Material: Cu/CuNi Accuracy = ± 0.5 °C
«BE-RF-PM» 9 9 Temperature sensors (pictures in the lab) Temperature sensors on the air Temperature sensors on the accelerating structures Temperature sensors on the DB Q and PETS Temperature sensors on the waveguides
«BE-RF-PM» 10 Data acquisition and LabVIEW software Data acquisition from the accelerating structures Data acquisition from the waveguides Data acquisition from the PETS Data acquisition from the magnets
«BE-RF-PM» 11 Data acquisition and LabVIEW software Data acquisition from the air thermocouples Real time plots Steady state condition at 40 o C
«BE-RF-PM» 12 Data analysis (20 o C) Super AS - 1 PETS - 1 DB Q - 1Air thermocouples - 1
«BE-RF-PM» 13 Data analysis (from 20 o C to 30 o C) Super AS - 1 PETS - 1 DB Q - 1Air thermocouples - 1
«BE-RF-PM» 14 Data analysis (30 o C) Super AS - 1 PETS - 1 DB Q - 1Air thermocouples - 1
«BE-RF-PM» 15 Data analysis (from 30 o C to 40 o C) Super AS - 1 PETS - 1 DB Q - 1Air thermocouples - 1
«BE-RF-PM» 16 Data analysis (effect of air speed on air temperature: 0.8 m/s 0.3 m/s) Air thermocouples - 3 Air thermocouples - 1 Air thermocouples - 2