Jeff T. Collins Undulator Support/Mover System 22-24 January 2008 LCLSLCLSLCLSLCLS LCLS Undulator Support/Mover.

Slides:



Advertisements
Similar presentations
Engineer Training XL1200 Drying System. Engineer Training XL1200 Drying System Confidential 2 XL1200 Drying System.
Advertisements

① The output signal of a room thermostat is ON or OFF according to changes of room temperature ② The power supply to a motorized valve is ON or OFF according.
Convection in Flat Plate Turbulent Boundary Layers P M V Subbarao Associate Professor Mechanical Engineering Department IIT Delhi An Extra Effect For.
Extended Surfaces Chapter Three Section 3.6.
Matter and Energy.
9645 TTCSI “I AM” SECONDARY SCHOOLS COMPETITION CHALLENGE 9645.
Conduction, Convection, & Radiation
Temperature Control of Filament Wound Composites during the Gelling Process By: Matt Ballard and Brooks Lively.
1 ISAT Module III: Building Energy Efficiency Topic 6:Stead-State Building Loads z Fabric Loss z Ventilation Loss z Environmental Temperature z Steady-State.
MECHANISM OF HEAT TRANSFER Mode of Heat transfer Conduction Convection
Heat Rate to a Chocolate Chip Cookie through various cooking Surfaces Date: Dec 11, 2006 Group Members: Tony Rands Adrian Williams Josh Dustin.
Thermal Analysis of short bake out jacket version 1 12-Nov-2013.
Jeff T. Collins Undulator Support/Mover System 14 March 2008 LCLSLCLSLCLSLCLS LCLS Undulator Support/Mover System:
The Pizza Pouch Project Joonshick Hwang Brian Pickup Winter 2007 ME 340 Final Project.
Ambient temperature inside an automobile subject to external conditions. MeEn 340 By Eric McKane and Benton Russell.
Modes of Heat Transfer P M V Subbarao Professor Mechanical Engineering Department Accounting of Natural Happenings …..
ENERGY FROM THE SUN Chapter 14.3 Pages Energy in the Atmosphere The sun is the source of ALL energy in our atmosphere. Three things that can.
Thermal Management Solutions from APW President Systems
Temperature and Heat Loss The following topics are covered in this presentation: Temperature and temperature scales Transfer of heat Thermal conductivity,
Cooling Hot Chocolate in an insulated container James Jackson and Jordan Peterson.
Cooling of Transformer
Wittaya Julklang, Boris Golman School of Chemical Engineering Suranaree University of Technology STUDY OF HEAT AND MASS TRANSFER DURING FALLING RATE PERIOD.
Heat Transfer: Physical Origins and Rate Equations
By Kasey Gillespie and Leonidas Leite You’re Ready, but is your pizza Hot?
3 rd Grade Energy Vocabulary. What do we call thermal energy that moves without touching anything? ___________________________.
T.M.F.T: Thermal Mechanical Fatigue Testing
1 BROOKHAVEN SCIENCE ASSOCIATES CFAC Review – Chris Channing P.E. Sr Project Engineer NSLS-II Conventional Facilities - Thermal Stability May 8, 2007.
T.M.F.T: Thermal Mechanical Fatigue Testing Wale Adewole Siyé Baker Heriberto Cortes Wesley Hawk Ashley McKnight.
Jet Fuel Vaporization and Condensation: Modeling and Validation C.E. Polymeropoulos Robert Ochs Rutgers, The State University of New Jersey International.
14-6 Latent Heat Latent Heat *Latent heat is heat required to make a state change occur…there is no temperature change. *Q=mL …. Where L is a latent heat.
Plenary This PowerPoint file contains the Plenary for this chapter in Physics For You. Most of these slides are paired with a corresponding slide in.
THERMAL ENERGY By Hannah Pelayic 1 st hour Picture of a solar flair.
Heat Transfer Carlos Silva December 9 th Energy transference Energy can be transferred between a system and its surroundings Work Heat Mass flow.
Presented to: By: Date: Federal Aviation Administration In-Flight Burn- Through Tests Aluminum vs. composite materials Aircraft Systems Fire Working Grp.
One-Dimensional Steady-State Conduction
Heat Transfer Conduction, Convection, & Radiation…oh my!!
10/29 Warm Up 1.Grab SWOD form 2. Do CONDUCTION for swod today: Definition: the transfer of heat between two substances that are in direct contact with.
Thermal Radiation Done By: Nujood Al-hashar Abrar Al-haddabi
SEPTEMBER 2002 Pixel Support Tube A. Smith LBNL 1 ATLAS Pixel Detector Heater Panel Testing Alexis Smith September 17, 2002.
Jet Fuel Vaporization and Condensation: Modeling and Validation Robert Ochs and C.E. Polymeropoulos Rutgers, The State University of New Jersey International.
INTRODUCTION TO CONVECTION
8.4 – Temperature, Thermal Energy, and Heat
1 BROOKHAVEN SCIENCE ASSOCIATES NSLS – II Stability Workshop Conventional Facilities Temperature Stability Chris Channing P.E. Sr. Project Engineer National.
Test set up Heat source: The radiant heat source used is shown in Fig 1. Temperature of source temp was set to 650 Materials tested: 6”x 6” samples of.
Federal Aviation Administration 0 Composite Wing Tank Flammability May 20, Composite and Aluminum Wing Tank Flammability Comparison Testing Steve.
Press the correct answer before it disappears! Click below to start…
Heat Transfer Review. What type of heat transfer does this picture describe? Radiation.
Jeff T. Collins Undulator Support/Mover System 20 October 2005 LCLSLCLSLCLSLCLS LCLS Undulator Support/Mover System.
Jeff T. Collins Undulator Support/Mover System 27 February 2008 LCLSLCLSLCLSLCLS LCLS Undulator Support/Mover System:
Chapter 3.4 Notes Thermal Rates.  The amount of heat that is transferred per unit time is the heat flow rate  Equation for heat flow rate = heat / time.
Various Methodologies for Calculating the Impacts on Delta-T From Independent Spent Fuel Storage Installations (ISFSI) Jim Holian and Steve Mirsky, SAIC.
Heat Transfer Su Yongkang School of Mechanical Engineering # 1 HEAT TRANSFER CHAPTER 6 Introduction to convection.
Heat Transfer Su Yongkang School of Mechanical Engineering # 1 HEAT TRANSFER CHAPTER 7 External flow.
GCSE ENERGY; THERMAL ENERGY TRANSFER 2
H. Abrahamsson, A. Borg, L. Ström Volvo Aero Corporation, S , Trollhättan, Sweden Internal Cooling of Hot Turbine Structures Z. G. Tari, L. Wang,
Use of Air Showers to Reduce Soaking Time for High Precision Dimensional Measurements Ted Doiron, Donna McLaughlin, Ann Schneider Engineering Metrology.
Heat transfer mechanism Dhivagar R Lecture 1 1. MECHANISMS OF HEAT TRANSFER Heat can be transferred in three different ways: conduction, convection, and.
OBJECTIVES 1.To understand the greenhouse effect 2.To use simple experimentation techniques including: observing and recording data, use of a control,
TEMPERATURE DISTRIBUTION ACROSS THE EXTENDED SURFACE
EXTENDED SURFACE HEAT TRANSFER EXPERIMENT
Heat Transfer & Thermal Insulation
Heat Transfer & Thermal Insulation
Heat gain and heat loss in buildings
Conduction, Convection, & Radiation
UNIT - 4 HEAT TRANSFER.
Volvo V70R Brake Rotor Heat Transfer
FREE CONVECTION – FIXED POWER TD1005
FORCED CONVECTION AND EFFECTIVE VELOCITY
Heat Transfer & Thermal Insulation
Undulator Hall Power Dissipation
Presentation transcript:

Jeff T. Collins Undulator Support/Mover System January 2008 LCLSLCLSLCLSLCLS LCLS Undulator Support/Mover System: Relay Rack Heat Dissipation & the Effects on the Overall System Jeff T. Collins

Undulator Support/Mover System January 2008 LCLSLCLSLCLSLCLS Support/Mover System Testing Background: During Operation, the Relay Rack Located Under Each Undulator System will Continuously Dissipate Approximately 150 Watts of Waste Heat. Concern Has Been Raised that the Relay Rack Heat Dissipation will Elevate the Temperature of the Girder and Undulator Body as Much as 1°C. Estimates of the Relay Rack Heating Effects on the Undulator System have been Analyzed by J. Welch (1/10/08 Memo, “Estimate of Localized Heating Due to 150W Rack”, Hot Rack Effect.pdf).

Jeff T. Collins Undulator Support/Mover System January 2008 LCLSLCLSLCLSLCLS Support/Mover System Testing Hello David, I estimated some of the localized heating effects a 150 W rack would induce when placed under an undulator segment. This estimate includes radiation heat transfer and makes a stab at combining free convection and forced convection, which are both significant. The attached picture is largely self explanatory. The outside of the rack will come up to 29 C and a boundary layer flow of warm (24.5 deg C) air will form around it. This warm air will rise, mostly vertically, and envelop a section of the undulator and the girder. Heat transferred to the undulator and girder at this location will conductively spread longitudinally, warming up the girder and segment, and then get transferred to the air. I think the estimated temperature changes are accurate to within a factor of ~ 1/2 to ~ 2X. - Jim 1/10/08 Memo from J. Welch to D. Schultz:

Jeff T. Collins Undulator Support/Mover System January 2008 LCLSLCLSLCLSLCLS Support/Mover System Testing The Experiment: A Combination of Infrared Imaging and Thermocouple Measurements were Used to Determine the Actual Undulator System Heating Effects from the Relay Rack Under Worst-Case Conditions where No Forced Air Flow is Present Along the Undulator. The LTT Set-Up at the APS was Used for the Experiments. Prior to Experimentation, Background Air Temperature Fluctuations Were Recorded Over a Weekend Period to Assess Air Temperature Stability in the LTT Test Area. A 156 Watt Heater Attached to a Spool Piece Was Placed Inside of a Relay Rack and the Relay Rack was Placed in Position Under the Support/Mover System Girder. The 156 Watt Heater Was Turned On and Infrared Images Were Acquired at a Rate of 1 per Minute for a Total of 20 Hours (1200 Images). After the 20 Hour Period, Temperatures Were Recorded Using a Type T Thermocouple at Various Locations On and Around the Undulator System.

Jeff T. Collins Undulator Support/Mover System January 2008 LCLSLCLSLCLSLCLS Support/Mover System Testing The Relay Rack: 156 Watt Heater Attached to Spool Piece Placed Inside of the Relay Rack

Jeff T. Collins Undulator Support/Mover System January 2008 LCLSLCLSLCLSLCLS Support/Mover System Testing The Radiometer System: The FLIR SC-6000 Radiometer was Recently Purchased in 2007 Two Weeks Ago The System Was Calibrated Using an Extended Area Blackbody The Calibration Yields 0.1°C Absolute Accuracy for Infrared Thermal Imaging The Thermal Imaging Resolution is Better than 25 milliKelvin

Jeff T. Collins Undulator Support/Mover System January 2008 LCLSLCLSLCLSLCLS Support/Mover System Testing Ambient Air Temperature Fluctuations in the LTT Area: Friday 3 PM Monday 11 AM  Ambient Air Temperature Fluctuation ≈ 0.7°C Temperature (°C) 0Time (hours)

Jeff T. Collins Undulator Support/Mover System January 2008 LCLSLCLSLCLSLCLS Support/Mover System Testing Rack Heating 156 Watts.avi The Thermal Imaging Results: Images Were Acquired at a Rate of 1 per Minute Over a 20 Hour Period 1200 Images Were Acquired The Data Was Converted into a Movie Time versus Temperature was Evaluated at Several Points on the System PRESS BUTTON TO PLAY MOVIE

Jeff T. Collins Undulator Support/Mover System January 2008 LCLSLCLSLCLSLCLS Support/Mover System Testing The Final Image After 20 Hours of Relay rack Heat Dissipation: Steady-State on the Relay Rack Surface is Reached in Approximately 3 Hours Variations Beyond Steady-State Track with Air Temperature Fluctuations ≈ 5.1°C Temperature Rise in the Center of the Relay Rack ≈ 1.16°C Temperature Rise on the Gusset Center ≈ 0.24°C Temperature Rise on the Girder Top Above the Relay Rack Unmeasurable Temperature Variation on the Undulator 0.31°C per Division Frame Number = Minutes

Jeff T. Collins Undulator Support/Mover System January 2008 LCLSLCLSLCLSLCLS Support/Mover System Testing Temperature Measurement Location Measured Temperature (°C) Floor Under the Undulator System Next to Relay Rack21.8 Inboard Wall Adjacent to Center of Undulator System22.4 Center Top of Relay Rack28.2 Hottest Spot on Top of Relay Rack (Rear Edge)28.9 Side of Relay Rack at Louvers32.3 Underside of Girder on Gusset Above Center of Relay Rack22.6 Edge of Girder Above Center of Relay Rack22.3 Top Center of Girder Above Center of Relay Rack22.1 Top Center of Girder at Upstream End21.9 Top Center of Girder at Downstream End21.7 Center of Undulator Above Center of Relay Rack21.7 Downstream End of Undulator21.7 Upstream End of Undulator21.8 Steady-State Temperature Measurements Taken at Various Points On and Around the Undulator System Using a Type T Thermocouple After 24 Hours of 156 Watt Relay Rack Heat Dissipation

Jeff T. Collins Undulator Support/Mover System January 2008 LCLSLCLSLCLSLCLS Support/Mover System Testing Conclusions: With 156 Watt Power Dissipation from the Relay Rack there is an Unmeasurable Temperature Variation on the Undulator. These Tests were Conducted Under Worst-Case Conditions with No 0.43 m/sec Tunnel Air Flow Along the Undulator. In Actual Operation with Tunnel Air Flow Present the Effects of Relay Rack Heat Dissipation Would be Even Less. The K-Value of the Magnets in the Undulator Will be Unchanged as a Result of the Heat Dissipation from the Relay Rack.

Jeff T. Collins Undulator Support/Mover System January 2008 LCLSLCLSLCLSLCLS Support/Mover System Testing Future Tests: Similar Tests Shall Be Performed Using an 800 Watt Load Contained Within the Relay Rack. An Attempt Shall be Made to Determine the Threshold Where Measurable Temperature Rise on the Undulator can be Observed as a Result of the Relay Rack Heat Dissipation.