CPT2000 Platinum Resistance CED7000 & others Signal calibrators CPT9000 Thermocouple CPT1000 Platinum Resistance Features & Benefits Reference Thermometers.

Slides:



Advertisements
Similar presentations
TEMPERATURE measurements
Advertisements

ME 388 – Applied Instrumentation Laboratory Temperature Measurement Lab.
ME 322: Instrumentation Lecture 17
MTE´s Portable Product Portfolio
3441 Industrial Instruments 1 Chapter 4 Thermal Sensors
Temperature Handheld WIKA Calibration Line Pressure Hand-Helds Signal Calibrator Hand-Helds Temperature Hand-Helds.
© 2014 Fluke Corporation Fluke Calibration Web Seminar Series Principles and practical tips about electrical, flow, pressure, RF and temperature calibration.
Overview of Temperature Measurement ME 115 Figures are from “Practical Guidelines for Temperature Measurement” unless otherwise notedwww.omega.com.
Engineering 80 – Spring 2015 Temperature Measurements
Temperature is more than just hot or cold - You are responsible for temperature - we give the tools.
Measurements in Fluid Mechanics 058:180:001 (ME:5180:0001) Time & Location: 2:30P - 3:20P MWF 218 MLH Office Hours: 4:00P – 5:00P MWF 223B-5 HL Instructor:
CheckSystem 2.1 Portable Test Systems Page 1 April 2011.
 Temperature sensors are the devices which are used to measure the temperature of an object.  These sensors sense the temperature and generate output.
Module 3 Eng. Asma Abu Baker. Introduction One of the most important uses of instruments or measuring devices is in the field of process control. If you.
4. Current and resistance
Interchangeability based Design of Resistance Temperature Detectors
Engineering Mechanical Laboratory Term Lab 9 (b): Thermocouple Lab 9(a): Viscosity.
Brief Overview of Hot Wire Anemometers GE 330: Mechatronics Paul Kawka.
28 Feb 2000ISAT 3001 Resistance Temperature Detectors (RTDs)
Instrumentation (AMME2700) 1 Instrumentation Dr. Xiaofeng Wu.
7526A Precision Temperature/Pressure Process Calibrator
1 CPB 5000 Pressure Balance -Product overview-. 2 CPB product line CPB 5000 „Standard“ CPB 3800 „Compact Line“ CPB 5000 „Premium“ HighEnd / Laboratory.
Transducers/Sensors Transducer/sensor converts a non- electrical quantity, measurand, into a related electrical output signal Ideally there is a linear.
MP Electronics 2 1IWF-EXP/ÖAW GRAZ  Power budget  Interface electronics: ~1.5 W  Probe electronics (standby): ~1.2 W  Heater power:~70 W  Power loss.
Training Making accurate Electrical Measurements.
Calibration Savvy. Calibration and Conformance  Calibration: Check a measurement against a known universally recognized standard to determine any deviation.
Engineering Mechanical Laboratory Term 1/2009 Lab 9 (b): Thermocouple Lab 9 (a): Viscosity Nopdanai Ajavakom.
Today’s topic RTD D1&D2 Today I will talk about something of RTD and use D1 light to take the AFP Sweep.
A new class in PC Data Acquisition Delphin Technology AG Felix Ottofuelling V5.0.
8000 Series Options/Technical Overview Series Precision Digital Multimeter New Technology – Multi Processor design No need for AutoCal – High precision.
1 HD SIGNAL CONDITIONER SERIES THERMOCOUPLE TRANSMITTER MODEL HD-TC MODEL & SUFFIX CODE SELECTION HD-TC MODEL ■ Output1 signal ■ Output2 signal Availability.
MicroK Slide:1 Introducing the microK Isothermal Technology Ltd.
Today’s agenda: Electric Current. You must know the definition of current, and be able to use it in solving problems. Current Density. You must understand.
Mechanical Measurement and Instrumentation MECN 4600
4.2.5 Parallel Circuits Wiring for Voltage. Definitions parallel circuit – a circuit in which two or more elements are connected so that each has its.
Merkmale SITRANS T Automation and Drives Process Instrumentation and Analytics Common Technical Data (1) Technical Data (2) Features Block Diagram Housings.
8000 Series Options/Technical Overview Series Precision Digital Multimeter New Technology – Multi Processor design No need for AutoCal – High precision.
Remote AI (Add 6 inputs/units, Max 48 inputs/recorder) VM7000A RS-485(Max 1200m) Remote AI (Max: 6 units) Recorder 12 CH Remote AI 6CH x 6units TTL: 48.
1 RTD (Resistance temperature detector) n Varying resistance with temperature n Good for measurement of small temperature differences n General equation.
RAVISANKAR G EMS INSTRUMENTS
1000 Series Ultra-Portable Multi Function Calibrator Portability, without compromise.
The Measurement of Temperature
1 Four-Wire RTD measurement: Error Analysis/ Experimental Results.
Thermo-energy audit Services for thermo-energy audit Temperature measurement.
Key ideas 1.3 Thermometer Thermometers Working principle
6.Temperature Transducer:- Temperature transducers can be divided into four main categories. 1. Resistance temperature detectors (RTD). 2. Thermocouples.
SITRANS T3K PA Field Instruments Process Instrumentation and Analytics Technical Data (1) Technical Data (2) Features Block Diagram SITRANS T3K PA Head.
Challenger NIST Traceable Air flow Calibrator. Features Dry air flow calibrator No moving parts NIST Traceable Actual & Standard Conditions 1 LPM to 30.
Engineering 80 – Spring 2016 Temperature Measurements 1 SOURCE: 3_standardbody__to-226_straightlead.jpg SOURCE:
Temperature Back to Basics RTDs (Resistance Temperature Detectors)
Temperature and Pressure Sensors Seth Price Department of Chemical Engineering New Mexico Tech Rev. 10/27/14.
Temperature Measurement with Thermistors Portland State University Department of Mechanical Engineering ME 121: Engineering Problem Solving.
LOGO Electronic Volume Converter TZ, PTZ ”Flougas-T”
Process Control Loop and Calibration Basics. Learning objectives ● Develop an understanding of calibration and why it’s important ● Review the related.
Product Overview Analogue Input, 2fold, SM  Box  Sensor connections
Product Presentation T12 Thermometer.
MECH 373 Instrumentation and Measurements
The Measurement of Temperature
資料擷取與感測器 應用實務.
ProtoDUNE SP – Slow control temperature readout setup test
PTS 3.3 C Portable Test System.
Thermocouples and rtd Prepared By: Ansari Najma A. ( )
HD SIGNAL CONDITIONER SERIES
AT-2040 Vibration Sensor test Set.
Overview of Temperature Measurement ME 115
Interchangeability based Design of Resistance Temperature Detectors
Prepared by Dr. Mohamed Ahmed Awad
Temperature Program Features & Benefits CPT1000 & othersB6000
Instrumentation and Control: ME- 441 Department of Mechanical Engineering UMT 1.
724 Temperature Calibrator
Presentation transcript:

CPT2000 Platinum Resistance CED7000 & others Signal calibrators CPT9000 Thermocouple CPT1000 Platinum Resistance Features & Benefits Reference Thermometers

Reference Thermometer CTP1000 Data Sheet CT61.10… PLATINUM RESISTANCE THERMOMETER  Measuring range -100 to 670 o C  Stability better than 40mK after 100h at 660 o C  Dimensions: Ø 6.35mm, l= 450mm  4-wire connection, ends stripped and tin-coated

Reference Thermometer CTP2000 PLATINUM RESISTANCE THERMOMETER  Measuring range -200 to 450 o C  Stability better than 50mK after 100h at 450 o C  Dimensions: Ø 6.35mm, l= 450mm  4-wire connection, ends stripped and tin-coated Data Sheet CT61.10…

Reference Thermometer CTP9000 THERMOCOUPLE  Measuring range: 0 – 1300oC  Thermocouple: Type S; Class 1  Dimensions: Ø 7mm, l = 1500mm  450mm cable, ends with 4mm connector Data Sheet CT61.10…

Order process A reference thermometer requires a traceable certificate. Choose between different calculation and documentation of the coefficients. The coefficient influences the uncertainty of the probes. 5

Reference thermometer Temperature Model CTP1000CTP2000CTP9000 Range -100 … +670 °C-200 … +450 °C0 … °C Elements Pt100 resistance Thermocouple Type S Dimensions Ø 6,35 mm, l = 450 mmØ 4 mm, l = 500 mmØ 7 mm, l = 1500 mm Features -4-wire connection -ends stripped and tin-coated -4-wire connection, -ends with 4 mm connector -With cold junction available - ends with 4 mm connector Suitable measuring devices: CEP6000 and CEP6100 Calculation of coefficients possible and necessary Calibration at an accredited laboratory

CTH6200CTH6500 StarterMedium -50…+250°C °F -200…+1500°C °F Pt100Pt100, TC, (humidity, flow) 0.05…0.2 K 0.03 K RTD 0.2 K TC 0.01°C up to 200°C, then 0.1°C datalogger -Datalogger optional - 2 channel version optional - Ex version optional ModelCEP3000 Starter Range TC (11), RTD (11), Ohms Elements Accuracy ± 0.4 °C for J T/C all errors included ± 0.3 °C for PT100 RTD Display0.1 °C FeaturesSimulate and measure 7 Hand- Helds portfolio Temperature

Portable Multi-Function Calibrator CEP6000 / CEP6100 Applications:  Range: resistance thermometers(13), thermocouples (13), resistance, current, voltage, frequency, pressure  Accuracy: % rdg (mA, V)  CEP6100 with calibration function Signal Calibrator Hand-Helds

Documenting CEP6100  Store up to 50 different UUT to CEP6100  Print certificate on site  Store certificate on PC  Calculates deviation for you Signal Calibrator Hand-Helds

High-precision process calibrator CED7000  Measuring range 0…100mA, 0…100V, 5…4000Ω, -210…+1200⁰C (type J), -200… +800 ⁰C (Pt100)  Accuracy : 0.003%  Measurement and simulation of thermocouples, resistance thermometers, resistance, current, voltage and pressure Data Sheet CT85.51…