1 OPSAWG Agenda Items 7,8, 9 Juergen Quittek, John Parello, Benoit Claise 78th IETF Meeting, Maastricht, 2010 7. Energy Management Framework / Architecture.

Slides:



Advertisements
Similar presentations
1 Introducing the Specifications of the Metro Ethernet Forum.
Advertisements

1 Introducing the Specifications of the Metro Ethernet Forum.
1 Introducing the Specifications of the Metro Ethernet Forum.
G : DCM Signaling Mechanism Using GMPLS RSVP-TE ITU-T Workshop on IP-Optical, Chitose, Japan 7/11/2002 Dimitrios Pendarakis, Tellium, Inc. ITU-T.
PCD Medical Device IT Management White Paper
© 2008 Cisco Systems, Inc. All rights reserved.Cisco ConfidentialPresentation_ID 1 Chapter 8: Monitoring the Network Connecting Networks.
Omniran TG 1 Cooperation for OmniRAN P802.1CF Max Riegel, NSN (Chair OmniRAN TG)
IP over ETH over IEEE draft-riegel-16ng-ip-over-eth-over Max Riegel
ETSI Workshop on Quality Issues for IP Telephony 8-9 June 1999, Sophia Antipolis, France ETSI PROJECT TIPHON overview of QoS activities ETSI Workshop on.
Objectives Overview Define an operating system
1 © 2004, Cisco Systems, Inc. All rights reserved. CCNA 2 v3.1 Module 4 Learning About Other Devices.
The Green Abstraction Layer A Standard Power-Management Interface for Next-Generation Network Devices By group 8 1.
© 2007 Cisco Systems, Inc. All rights reserved.ICND1 v1.0—2-1 Ethernet LANs Operating Cisco IOS Software.
© 2003, Cisco Systems, Inc. All rights reserved. FWL 1.0— © 2003, Cisco Systems, Inc. All rights reserved.
TC100 1 Energy saving system for home appliances and home network devices - Part 1 : Architecture and requirements Korea Electronics Technology Institute.
MIB Browser Watch your Network on the move. Product Overview SNMP MIB Browser for iOS enables the user to browse/view the MIB data of SNMP enabled network.
LLDP-MED Location Identification for Emergency Services Emergency Services Workshop, NY Oct 5-6, 2006 Manfred Arndt
1 © 2006 Cisco Systems, Inc. All rights reserved. Session Number Presentation_ID Using the Cisco Technical Support & Documentation Website for Security.
EMAN WG IETF 84. Note Well Any submission to the IETF intended by the Contributor for publication as all or part of an IETF Internet-Draft or RFC and.
Networking Components
1 PSAMP Protocol Specifications IPFIX IETF-64 November 10th, 2005 Benoit Claise Juergen Quittek Andrew Johnson.
Configuring Routing and Remote Access(RRAS) and Wireless Networking
LLDP-MED Location Identification for Emergency Services Emergency Services Workshop, NY Oct 5-6, 2006 Manfred Arndt
AutoDiscovery Device Attributes Discovery Ports Discovery CDP Neighbours Discovery Layer 3 Hosts Discovery.
1 Remote Management of Wireless Gateway Student Name: Dinesh D N (BITS ID: 2004HZ12158) MphasiS Technologies Ltd, Bangalore March 2006.
©2013 – JouleX Enterprise Energy Management Quickly identify energy waste Reduce energy usage and costs Lower carbon emissions Agentless, network-based.
Component 4: Introduction to Information and Computer Science Unit 7: Networks & Networking (Part 4 of 5)
Draft-ietf-eman-energy-aware-mib-01 Energy Management Framework draft-ietf-eman-framework-01 J. Parello, J. Quittek, B. Schoening, B. Claise.
Home Control Protocol for Smart Devices Hojin Park WG!-N1505.
Unrestricted Connection manager MIF WG IETF 78, Maastricht Gaëtan Feige, Cisco (presenter) Pierrick Seïté, France Telecom -
INTERNATIONAL ELECTROTECHNICAL COMMISSION © IEC:2007 PC118 WG1 Draft Framework China PC 118/WG1 Meeting, , Santa Clara.
© 2007 Cisco Systems, Inc. All rights reserved.Cisco Public ITE PC v4.0 Chapter 1 1 Connecting to the Network Networking for Home and Small Businesses.
BAI513 - PROTOCOLS SNMP BAIST – Network Management.
Energy Efficient Digital Networks Rich Brown Lawrence Berkeley National Laboratory Presentation to DOE State Energy Advisory Board Meeting August 14, 2007.
©2013 – JouleX Enterprise Energy Management Quickly identify energy waste Reduce energy usage and costs Lower carbon emissions Agentless, network-based.
Cisco Confidential © 2011 Cisco and/or its affiliates. All rights reserved. 1 Cisco EnergyWise.
Module 9: Designing Network Access Protection. Scenarios for Implementing NAP Verifying the health of: Roaming laptops Desktop computers Visiting laptops.
\ 1 Presentation for SC25 WG1 N1651 RC (Residential Complex) -EMS for HES Wanki Park ETRI, Korea Ilwoo Lee (ETRI, Korea) ISO/IEC.
Power and Energy Monitoring MIB draft-ietf-eman-energy-monitoring-mib-01 Mouli Chandramouli, B. Schoening Juergen Quittek Thomas Dietz Benoit Claise 82th.
Module 3 Configuring File Access and Printers on Windows 7 Clients.
Module 3: Configuring File Access and Printers on Windows 7 Clients
System integration of WAP and SMS for home network system Editor : Chi-Hsiang Wu, Rong-Hong Jan School : the National Chiao Tung University Source : Computer.
Dec UtilityAMI OpenHAN TF Requirements Working Group Specification Briefing January 2008.
1 Session Number Presentation_ID © 2002, Cisco Systems, Inc. All rights reserved. Using the Cisco TAC Website for Security and Virtual Private Network.
A machine that acts as the central relay between computers on a network Low cost, low function machine usually operating at Layer 1 Ties together the.
Omniran CF CF Network Reference Model Introduction Date: Authors: NameAffiliationPhone Max RiegelNokia Networks+49.
SLRRP BoF 62 nd IETF Scott Barvick Marshall Rose
© 2007 Cisco Systems, Inc. All rights reserved.Cisco Public ITE PC v4.0 Chapter 1 1 Communicating over the Network Network Fundamentals – Chapter 2.
PSAMP MIB Status Managed Objects for Packet Sampling A Status Report Thomas Dietz Benoit Claise
PSAMP MIB Status Managed Objects for Packet Sampling A Status Report Thomas Dietz Benoit Claise
Chapter 9 Operating Systems Discovering Computers Technology in a World of Computers, Mobile Devices, and the Internet.
Networking Components William Isakson LTEC 4550 October 7, 2012 Module 3.
Slide 1 2/22/2016 Policy-Based Management With SNMP SNMPCONF Working Group - Interim Meeting May 2000 Jon Saperia.
Draft-ietf-eman-energy-aware-mib-01 Energy-Aware Networks and Devices MIB draft-ietf-eman-energy-aware-mib-01 Benoit Claise, John Parello.
IPFIX MIB Status Managed Object for IP Flow Export A Status Report Thomas Dietz Atsushi Kobayashi
Kevin Harrison LTEC 4550 Assignment 3.  Ethernet Hub  An unsophisticated device that is used for connecting multiple Ethernet devices together.  Typically.
Wireless LAN Requirements (1) Same as any LAN – High capacity, short distances, full connectivity, broadcast capability Throughput: – efficient use wireless.
David B. Johnson Rice University Department of Computer Science DSR Draft Status Monarch Project 57th IETF.
Topic 11 Network Management. SNMPv1 This information is specific to SNMPv1. When using SNMPv1, the snmpd agent uses a simple authentication scheme to.
Energy Management (EMAN) Applicability Statement draft-tychon-eman-applicability-statement-05 Emmanuel Tychon Brad Schoening Mouli Chandramouli Bruce Nordman.
Cisco – Greening the World Cisco Systems, Inc. presentation to the TERENA Networking Conference May 2012 Chris Lonvick Director, Research and Advanced.
IFIP-UNU ADVANCED COURSE ON NETWORKING AND SECURITY Module II-Wireless Communications Section 5 Access Points.
IEEE MEDIA INDEPENDENT HANDOVER
SUPPORTING DISPLAY DEVICES, I/O DEVICES, AND ACPI
Implement Inter-VLAN Routing
Brief Introduction to IEEE P802.1CF
Implement Inter-VLAN Routing
Implement Inter-VLAN Routing
ARC Closing Report Date: Authors: January 2016
Implement Inter-VLAN Routing
Presentation transcript:

1 OPSAWG Agenda Items 7,8, 9 Juergen Quittek, John Parello, Benoit Claise 78th IETF Meeting, Maastricht, Energy Management Framework / Architecture draft-claise-power-management-arch Energy Management IDs Requirements for Energy Management: draft-quittek-power-monitoring-requirements-01 Power and Energy Monitoring MIB: draft-claise-energy-monitoring-mib-04 Definition of Managed Objects for Energy Management: draft-quittek-power-mib-01 Considerations for Power and Energy Management: draft-norwin-energy-consider Energy Management Working Group Charter Proposal charter proposal

Energy Management Framework/Architecture draft-claise-power-management-arch-00 Brad Schoening, John Parello, Benoit Claise 78th IETF Meeting, Maastricht, 2010

3 Architecture: Problem Description  Monitoring Power and Energy, based on existing data models (IEC 61850, IEC , ANSI C12.20, …)  The target devices include: Router & switches Attached devices such as Power over Ethernet (PoE) devices But not limited to PoE devices. Example: PC Intelligent meters Proxy for building energy management Home energy gateway Etc…  Based on the requirement draft-quittek-power-monitoring-requirements-01  Currently some overlap with draft-claise-energy-monitoring-mib-04 Existing Implementation

4 Architecture: Example: Router, PoE, and non PoE device

5 Architecture: Example: BMS IP

6 Architecture: Example: Smart PDU

7 Architecture: Overview of Scenarios  Use Case Scenarios Scenario 1: Switch with PoE endpoints Scenario 2: Switch with PoE endpoints + device(s) Scenario 3: A switch with Wireless Access Points Scenario 4: Network connected facilities gateway Scenario 5: Data Center Network Scenario 6: Power Consumption of UPS Scenario 7: Power Consumption of Battery-based

8 Architecture: Overview of New Concepts  Monitoring Power Monitor Information Power Monitor Meter Domain Power Monitor Parent and Child Power Monitor Levels Power Monitor Context  TBD Discovery Authentication Entitlement  Basically a new architecture for OPS We should lay down a good foundation for future work in the energy area

9 Architecture: Concept of Parent/Child  The parent/Child = the parent reporting the power for the end point (child) And actually the parent controlling the child power states (not in scope) For example, Wake-on-Lan  Scaling issue if the NMS would control each child  Building Management System requires a proxy pmIndex 1, port, metered power pmIndex 2, phone, negotiated power, parent = switch pmIndex 3, PC, reported power, parent = switch

10 Architecture: Concept of Power Levels Level ACPI Global/System State Name 1 G3, S5 Mech Off 2 G2, S5 Soft Off 3 G1, S4 Hibernate 4 G2, S3 Sleep ( Save-to-RAM) 5 G2, S2 Standby 6 G2, S1 Ready 7 G0, S0, P5 LowMinus 8 G0, S0, P4 Low 9 G0, S0, P3 MediumMinus 10 G0, S0, P2 Medium 11 G0, S0, P1 HighMinus 12 G0, S0, P0 High G = Global state, S = System state, P = Performance state ACPI: Advanced Configuration and Power Interface Non-operational states Operational states

11 Architecture: Power Levels  How many operational states do we need? Example1: an IP phone with an external dial pad and power savings (LCD off) having three power modes (i.e., 9w, 12w, 14w) Example2: a Laptop PC with Windows 7 has 3 states: High Performance, Balanced, and Power Saver. Example3: video camera, 4 levels (lower resolution, take samples) Example4: PoE has 5 classes of power in IEEE 802.3at and pethPsePortPowerClassifications

12 Architecture: Concept of User Defined Power Levels User Defined Power Level User Defined Name 0 none 1 short 2 tall 3 grande 4 venti STD Power Level/Name User Power Level / Name 1 / Mech Off 0 / none 2 / Soft Off 0 / none 3 / Hibernate 0 / none 4 / Sleep, Save-to-RAM 0 / none 5 / Standby 0 / none 6 / Ready 1 / short 7 / LowMinus 1 / short 8 / Low 1 / short 9 / MediumMinus 2 / tall 10 / Medium 2 / tall 11 / HighMinus 3 / grande 12 / High 4 / venti Implementation: Device Manufacturer’s Capability Interface: Mapped to the Standard Levels

Energy Management IDs Various, Benoit Claise 78th IETF Meeting, Maastricht, 2010 Requirements for Energy Management: draft-quittek-power-monitoring-requirements Definiton of Managed Objects for Energy Management: draft-claise-energy-monitoring-mib-04 draft-quittek-power-mib Considerations for Power and Energy Management: draft-norwin-energy-consider

draft-quittek-power-monitoring-requirements-01 Abstract This memo discusses requirements for energy management, particularly for monitoring consumption and controlling power states of devices. This memo further shows that existing IETF standards are not sufficient for energy management and that energy management requires architectural considerations that are different from common other management functions.

draft-quittek-power-mib-01  Created from Requirements document  In Process of merging with claise monitoring MIB  Contain the optional battery module  Abstract This memo defines a portion of the Management Information Base (MIB) for use with network management protocols in the Internet community. In particular, it describes extensions to the Entity MIB to provide information about the energy consumption, the power states and battery status of managed devices and their components.

draft-claise-energy-monitoring-mib-04  Created from Requirements document  Defines monitoring in terms of: Power Monitor Information Power Monitor Meter Domain Power Monitor Parent and Child Power Monitor Context Power Monitor Levels Power Monitor Usage Measurement Optional Power Usage Quality Optional Energy Measurement

17 draft-claise-energy-monitoring-mib-04 pmIndex 1, port, metered power pmIndex 2, phone, negotiated power pmIndex 3, PC, reported power pmIndex 3 pmIndex 2 pmIndex 1 Via an agent Known via LLDP-MED Can we assume that the ENTITY-MIB is supported on all monitored devices? No, so can’t use the entPhysicalIndex as THE index in the table New index: pmIndex, for each power monitor

18 Monitoring MIB: What’s new in version 3 & 4  Explained all the concepts  More use cases  Link with the LLDP-MED MIB  User defined Power Levels  Power Quality  Better alignment with the IEC data model  More reviews from partners  Note: this is a very very quick summary of a 75 pages draft

draft-norwin-energy-consider-00  Recently Submitted  Lists and defines areas and concepts to be considered with energy management

Summary  Multiple drafts evolving together  Requirements  MIB  Architecture  A series of new concepts for the architecture  We should lay down a good foundation for future work in the energy area

21 END