SC9XA WGA4-2 16 November 2010 M Petkova
CLC/TS50238-2:2010 Railway applications - Compatibility between rolling stock and train detection systems Part 2: Compatibility with track circuits (pr15360) 100% positive vote received Individual results yes/no - 21/0 Publication prepared July 2010 All editorial comments addressed Convenor of WGA4-2 M Petkova
CLC/TS50238-3:2010 Railway applications - Compatibility between rolling stock and train detection systems Part 2: Compatibility with axle counters (pr21550) 96% weighted positive vote received Individual results yes/no - 20/1 Publication prepared July 2010 All editorial comments addressed Convenor of WGA4-2 M Petkova
Definition of susceptibility limits of axle counters Convenor of WGA4-2 M Petkova
Standard co-ordinates Convenor of WGA4-2 M Petkova
FM – x direction Convenor of WGA4-2 M Petkova
FM – y direction Convenor of WGA4-2 M Petkova
FM – z direction Convenor of WGA4-2 M Petkova
Frequency Management for Axle Counters – Band 1 Convenor of WGA4-2 M Petkova
Frequency Management for Axle Counters – Band 2 Convenor of WGA4-2 M Petkova
Frequency Management for Axle Counters – Band 3 Convenor of WGA4-2 M Petkova
Pr16623 Basic parameters for train detection systems to allow safe detection of RST Resolution 34/1 Noting BT decision D136/033 to set back project 16623 to PWI stage, SC9XA resolves to initiate a survey group within WGA4-2 with the remit of identifying the characteristics of train detection that need to be defined, with the objective of initiating a New Work Item Proposal. Convenor of WGA4-2 M Petkova
Report from the survey group/WGA4-2 Progress to date 28 September – 1st meeting of WGA4-2 Decision taken to continue work in two subgroups focused on track circuits and axle counters, correspondingly 10 November – 1st meeting of TC survey group 11 November – 1st meeting of AxC survey group 2 parameters list developed accordingly and responsibility for managing assigned Additional responsibility identified for IM for maintaining parameters in the framework of interoperability Convenor of WGA4-2 M Petkova
Way forward SC9XA issues the report of the survey group to all National Committees for 2 month enquiry to finalise the new mandate for WGA4-2. WGA4-2 starts work immediately, to avoid further delay to the introduction of Interoperability WGA4-2 remains a joint WG. New members are welcome. Convenor of WGA4-2 M Petkova
{ Frequency management (rules for definition) CCS TSI – interface Doc RST AxC (or TC, or other) Design guideline Design target TSI Implementation timeframe X years X years Basic parameters for target system { TS50238 - matured TS50238 (Appendix C) Compatibility with other/old vehicles + + + Convenor of WGA4-2 M Petkova
16.7 Hz traction – next step for FM All Track Circuits currently listed as preferred can be taken into account for the FM. - Austria – S50108914 106,7 Hz; S1722-8 100 Hz - Germany – FTGS 46, FTGS 917 - Netherlands – FTGS 46, FTGS 917, HVI - Norway – FTGS 46, FTGS 917, 95 Hz, 105 Hz - Sweden – JRK10470 Switzerland – UGSK 95, UGSK 3, FTGS 46, FTGS 917 Note: TI21 listed as preferred in TS50238-2 but since dropped from the list by the Norwegian National Rail Administration Convenor of WGA4-2 M Petkova
DC Traction 750 V DC special case Proposed steps to achieve f-management 750 V DC special case 1 500 V DC and 3 000 V – f management to be merged if possible, as in the Energy TSI, across the f-range Audio F track circuits –1.6 – 7kHz Convenor of WGA4-2 M Petkova
50Hz traction – proposed steps to achieve f-management LF area Single f + 75/275 Hz – special case Coded track circuits Audio F track circuits –1.6 – 7kHz Higher F management – 50-70kHz Convenor of WGA4-2 M Petkova
List of preferred track circuits for 50 Hz traction (TS50238-2) - Belgium – Jade 2, HVI TC - Czech Republic – EVKO 275 Hz, KOA 75 Hz, KOA 275 Hz, ASE, ASAR - Denmark – DC TC, 77 Hz, FTGS 46, FTGS 917 - France – UM71 C*, UM71 CB*, UM71 CTVM*, HVI, SJB* - Italy – ATIS (CBDAC), Digicode DTC24-2 - Poland – SOT-1, SOT-2, EON-1, EON-3, EON-6 - Netherlands – Jade 1-28, Jade 1-31, Jade 1-49, Jade 1-67, Jade 2, HVI - UK – EBI Track 200 (TI21), DC AC immune various, UM71 C TVM SEI - Spain – FS3000 Convenor of WGA4-2 M Petkova
Q&A Thank you for your attention Convenor of WGA4-2 M Petkova