1 Division Appareillage et Système Résidentiels 1 IP SYSTEM Wiring Devices and Home Systems Division
2 Division Appareillage et Système Résidentiels SETTING PC with WINDOWS XP
3 Division Appareillage et Système Résidentiels SETTING CONTROL PANNEL ACTIVATION UPNP CONNECTION (MANDATORY) SYSTEM TROUBLESHOOTING:
4 Division Appareillage et Système Résidentiels MANDATORY “Start Control Panel Administrative Tools Services” and start and set as “Automatic” the following services: SSDP Discovery Service Universal Plug and Play Device Host
5 Division Appareillage et Système Résidentiels SYSTEM TROUBLESHOOTING: MANDATORY setting parameters : -Disable FIREWALL -Enable UPNP
6 Division Appareillage et Système Résidentiels “C:\ProgramFiles\CommonFiles\Bticino\BtCommunicationServer\Bticino.OpenServer.exe ” SYSTEM TROUBLESHOOTING: MANDATORY :ENABLE THE BTICINO.OPENSERVER On the WINDOWS FIREWALL go to the EXCEPTION MENU and ADD a program following this link:
7 Division Appareillage et Système Résidentiels Go to “Start Control Panel Windows Firewall Allow a program or feature through Windows Firewall Change settings” and enable “Network Discovery” and “Bticino.OpenServer.exe” (you must click “Add Program…” “Browser” and select “C:\Program Files\Common Files\Bticino\BtCommunicationServer\Bticino.OpenServer.exe” for x86 platform or “C:\Program Files (x86)\Common Files\Bticino\BtCommunicationServer\Bticino.OpenServer.exe” for x64 platform. For both program you must enable “Home/Work (Private)” and “Public”. How disable FIREWALL using WINDOWS 7 ?
8 Division Appareillage et Système Résidentiels Go to “Start Control Panel Network and Sharing Center Change Advanced sharing settings” and activate the “Network Discovery” Then go to “Start Control Panel Administrative Tools Services” and start and set as “Automatic” the following services: SSDP Discovery UPnP Device Host How to enable UPNP SERVICE using WINDOWS 7?
9 Division Appareillage et Système Résidentiels HOW RUN A SW IN DIAGNOSTIC MODALITY?
10 Division Appareillage et Système Résidentiels SOFTWARE TROUBLESHOOTING: HOW RUN THE SOFTSWITCHBOARD IN DIAGNOSTIC WAY? -Create a link on the desktop of the SW SOFTSWITCHBOARD -Change the properties adding “ /LOG” FOR WINDOWS XP: C:\Documents and Settings\Name Surname\Documents\BTicino\SoftSwitchboard_0300\logs FOR WINDOWS VISTA and 7: C:\Users\Name Surname\Documents\BTicino\SoftSwitchboard_0300\logs WHERE I FOUND THE LOGS FILES?
11 Division Appareillage et Système Résidentiels SOFTWARE TROUBLESHOOTING: HOW RUN THE ALARM MANAGER IN DIAGNOSTIC WAY? -Create a link on the desktop of the SW ALARM MANAGER -Change the properties adding “ /LOG=1” FOR WINDOWS XP: C:\Documents and Settings\Name Surname\Documents\BTicino\AlarmManager_0100\logs FOR WINDOWS VISTA and 7: C:\Users\Name Surname\Documents\BTicino\AlarmManager_0100\logs
12 Division Appareillage et Système Résidentiels WHERE I FOUND THE LOGS FILE? WINDOWS XP c:\document and settings\all user\application data\BTicino\VDESystemSuite\SVR\Logs To activate logs for BtCommunicationServer and BtAlarmLogger you must respectively modify these text files: C:\Program Files \Common Files\Bticino\BTAlarmLogger\Bticino.AlarmLogger.exe.config C:\Program Files \Common Files\Bticino\BtCommunicationServer\Bticino.OpenServer.exe.config Select and OPEN it with note pad. You must set to 1 the tag under “LOGLEVEL”: SOFTWARE TROUBLESHOOTING:
13 Division Appareillage et Système Résidentiels THE END