LEIR Schottky renovation M.Andersen –BE-BI-SW 29/05/2013.

Slides:



Advertisements
Similar presentations
What is Computer Software?. Hardware vs Software Got to have both to get the job done!
Advertisements

By the end of this section, you will know and understand the hardware and software involved in making a LAN!
Supervisory Control & Data Acquisition DAQ Networking.
Gelu M. Nita NJIT. Noise Diode Control Day/Night Attn. Ctrl. Solar Burst Attn. Ctrl. V/H RF Power Out Attn. Ctrl. Temperature Sensors.
Tunis, Tunisia, 28 April 2014 Business Values of Virtualization Mounir Ferjani, Senior Product Manager, Huawei Technologies 2.
Linux Migration GBT e2e Software Review May 3, 2005 Ramon Creager Melinda Mello
Computers Are Your Future © 2008 Prentice-Hall, Inc.
Operating Systems High Level View Chapter 1,2. Who is the User? End Users Application Programmers System Programmers Administrators.
CSCI 4550/8556 Computer Networks Comer, Chapter 10: LAN Wiring, Physical Topology, and Interface Hardware.
Existing Industrial Solutions and Virtual Instrumentation Integration into GANMVL Reinhard Bacher, Michael Seebach DESY.
MCITP: Microsoft Windows Vista Desktop Support - Enterprise Section 1: Prepare to Deploy.
1 Project supervised by: Dr Michael Gandelsman Project performed by: Roman Paleria, Avi Yona 26/4/2004 Multi-channel Data Acquisition System Final_A Presentation.
Introduction to windows operating system i
Mid-term Project Presentation Eli Bendersky Igor Oks.
EtherCAT Driver for Remote I/O James Rowland, Ronaldo Mercado and Nick Rees.
I/O Tanenbaum, ch. 5 p. 329 – 427 Silberschatz, ch. 13 p
BI SW for LINAC4 On behalf of BE/BI/SW BI software development process Specifications List of BI Systems – Not covered: PSB ring systems Conclusions Lars.
LAN Wiring & Physical Interfaces Lecture 6. Network Interfaces Every device has some form of a network interfaces. A PC has a Network Interface Card (NIC).
LXI Standard – Current and Future David Owen – Pickering Interfaces TC Chair LXI Consortium LXI – “It’s About Your Time”
A modern NM registration system capable of sending data to the NMDB Helen Mavromichalaki - Christos Sarlanis NKUA TEAM National & Kapodistrian University.
Agilent N432A Thermistor Power Meter Firmware Upgrade Process.
Data Acquisition Software Integration and ADC Characterisation Jack Hobbs 4 th August
UNIX System Administration OS Kernal Copyright 2002, Dr. Ken Hoganson All rights reserved. OS Kernel Concept Kernel or MicroKernel Concept: An OS architecture-design.
IS Fall 2009 Chapter 3 8/31/2009. LOOKING AT THE PARTS 8/17/2009IS 2101/01---Fall
DAQ Cards, or Instruments The purpose of this presentation is to familiarize new Lab View users to the different computer aided test recourses available.
DLS Digital Controller Tony Dobbing Head of Power Supplies Group.
◦ What is an Operating System? What is an Operating System? ◦ Operating System Objectives Operating System Objectives ◦ Services Provided by the Operating.
A+ Guide to Software Managing, Maintaining and Troubleshooting THIRD EDITION Introducing and Comparing Operating Systems Chapter 1.
Markus Joos, EP-ESS 1 “DAQ” at the El. Pool Aim and preconditions Hardware Operating system support Low level software Middle level software High level.
DIGITAL CONTROL INTERFACES MH0307 PLC & DATA ACQUISITION SYSTEMS DEPARTMENT OF MECHATRONICS ENGINEERING SRM UNIVERSITY.
HYDRA: Using Windows Desktop Systems in Distributed Parallel Computing Arvind Gopu, Douglas Grover, David Hart, Richard Repasky, Joseph Rinkovsky, Steve.
1 Lecture 7 LAN Wiring, Physical Topology, and Interface Hardware Computer Networks CS 4316.
HYDRA: Using Windows Desktop Systems in Distributed Parallel Computing Arvind Gopu, Douglas Grover, David Hart, Richard Repasky, Joseph Rinkovsky, Steve.
Networks.
CE Operating Systems Lecture 3 Overview of OS functions and structure.
Latest ideas in DAQ development for LHC B. Gorini - CERN 1.
Samantha. What is it? –It is a Wi-Fi interface for the Lego Mindstorms –It replaces the Bluetooth connection for running matches It is mostly for running.
CERN Control Standards Front-End Computer Layer Stéphane Deghaye BE/CO/FE
IPHC - DRS Gilles CLAUS 04/04/20061/20 EUDET JRA1 Meeting, April 2006 MAPS Test & DAQ Strasbourg OUTLINE Summary of MimoStar 2 Workshop CCMOS DAQ Status.
CMPF124 Basic Skills For Knowledge Workers Chapter 1 – Part 1 Introduction To Windows Operating Systems.
PSI Power Supply Controls MedAustron Controls Workshop 1 PR a-FMO-PSI_Power_Supply_Controls.pptx F. Moser - PSI Power Supply Controls 1.
REDNet - Status overview Rok Stefanic Ziga Kroflic
NetTech Solutions Resolving Issues with Locally Attached Devices Lesson Twelve.
PXI Systems - Discussions Gueorgui ANTCHEV / EP-ESSEPTAB Meeting February 2003Slide 1 of 3 PXI = Compact PCI + eXtensions for Instrumentation PXI is an.
Fast and fluid graphics Wide range of network conditions New client devices & form factors Windows Metro style user interface Mobile devices, WAN.
EPM-Series Power Meter(N1913/14A) Firmware Upgrade Process.
Overview Consolidation projects for PS LIU-PS Main observable review Conclusion Acknowledgements S. Gilardoni R. Steerenberg G. Metral H. Damerau BI colleagues.
INFORMATION SYSTEM – SOFTWARE TOPIC: GRAPHICAL USER INTERFACE.
Device/Driver Support for Network Based Devices EPICS Collaboration Meeting Jun, 2003.
5 th October 2004Hardware – KS41 Hardware Objectives: Computer systems  What do they do?  Identify the hardware that makes up a computer system (PC)
BPM stripline acquisition in CLEX Sébastien Vilalte.
Operating Systems. Categories of Software System Software –Operating Systems (OS) –Language Translators –Utility Programs Application Software.
Sven Ubik, Aleš Friedl CESNET TNC 2009, Malaga, Spain, 11 June 2009 Experience with passive monitoring deployment in GEANT2 network.
4. Operations and Performance M. Lonza, D. Bulfone, V. Forchi’, G. Gaio, L. Pivetta, Sincrotrone Trieste, Trieste, Italy A Fast Orbit Feedback for the.
PXI-Based Hybrid Test Systems Nick Hickford UK Sales Manager, Pickering Interfaces
COMPUTER NETWORKS CS610 Lecture-11 Hammad Khalid Khan.
Fermilab Control System Jim Patrick - AD/Controls MaRIE Meeting March 9, 2016.
Operating System & Application Software
Nature & Types of Software
Group Manager – PXI™/VXI Software
Protocols and Layering
Chapter 4 The Power behind the Power
N8262A P-Series Modular Power Meter Firmware Upgrade Process
ME3200 ELECTRONIC INSTRUMENTATION AND MEASUREMENT (INDUCTION PROGRAM) [Slide 3] Function/Arbitrary Waveform Generator BY DREAMCATCHER
Measurement & Automation Explorer
Computer Science I CSC 135.
Outline Overview Development Tools
Chapter 4 The Power behind the Power
EPICS: Experimental Physics and Industrial Control System
Chapter 13: I/O Systems “The two main jobs of a computer are I/O and [CPU] processing. In many cases, the main job is I/O, and the [CPU] processing is.
Presentation transcript:

LEIR Schottky renovation M.Andersen –BE-BI-SW 29/05/2013

Actual devices

Agilent N9020 A 1. Vertical 2. Horizontal 3.Longitudinal

Interface Based on Windows XP (upgrade is possible) Running VSA SW package When used away from LEIR control room, use Remote Desktop

SW screen

What are the issues? Reliability: system freezes, sometimes hard reset is the only solution. Lacking responsiveness, latency and lagging, freezing. Incomplete results- requires extra steps to compute Schottky end-results. Inconvenient – one needs 3 simultaneous remote desktops to 3 devices. Non-compliant with CO infrastructure Windows XP – IT no longer supports and allows it on the tech-net.

Problem causes 1. Remote Desktop strains resources a.3-5 Mbps on average b.20 Mbps bursts c.Non-uniform network load. 2. Windows XP

Renovation possibilities Improve interface with existent acquisition HW Replace acquisition HW SW with new one

Home build HW Home build HW Can Tune measurement Electronics (BBQ) handle the job? analogue down mixing with an analogue mixer, followed with an analogue low-pass filter “..Given the parameters of your signal (span of 300 kHz), there should not be any loss of information even if the signal is around 1 MHz, requiring sampling at 2 MHz…” Marek Gasior Replace Acquisition HW with a new system

Agilent PXI HW Agilent PXI HW High cost modular PXI solutions from agilent based on M9202A digitizers. Data visualisation and analysis based on the same SW platform as current N9020A. Software interface libraries are for Windows/Labview only Costly (€ 50K) and does not solve our problem. Replace Acquisition HW with a new system

Improve perfomance by reducing network traffic strain Make network traffic more homogenous Only transmit the actual numeric data withot graphics ”Hide” 3 Agilent devices behind a FEC running FESA. Dedicated op. application would improve user experinece Improve current interface Improve interface with existent acquisition HW

Proposed scheme Improve interface with existent acquisition HW

Has been successfully implemented before Known to be working GPIB to LAN adapter does not require GPIB interface card Open source libraries exist ÷GPIB is an old bus standard GPIB SW interface

Ethernet - initial picture TCPIP-LAN through IVI Class Driver ( direct interface to LabWindows/CVI or Microsoft COM) Lower level Agilient I/O Libraries suite provides drivers and libraries interface for C- C++,C#.NET, Labview, Matlab. Only Windows OS- is supportd

Ethernet on LINUX Agilent support message based SCPI (Standard Command for Programmable Instrument) standard which is verdor and interface independent SCPI commands are transparent over LAN, GPIB or USB. Linux sockets over port 5025 allows for SCPI link to the device.

To be done: Consolidate & formalize SCPI functions into a proper SW API library. Investigate operational use-cases: free-running vs. MTG synchronous triggering Specify and develop an initial FESA class handling all three AN9020A devices. Produce an application for the operation. Evaluate upgrade (Windows 7 + new processor and SSD, CHF 4150,- /device)

BCTs In LEIR: TRIC based Fast BCTs have been operating in parallel, ready to replace old system. In LN3: TRICs are also deployed but due to baseline slope distortions can’t replace the old yet; HW based solution is being tested Ring BCT system based on Linux and VD80 ADC modules runs in parallel.