Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Manufactured Homes Weatherization UES Measures Regional Technical Forum June.

Slides:



Advertisements
Similar presentations
Sunset Date Extension: Manufactured Homes HVAC Measures Regional Technical Forum November 18 th, 2014.
Advertisements

SEEM Calibration: Revisited Revising the regression to use continuous heat loss variable Regional Technical Forum December 17, 2013.
New Construction Calibration Research Results and Request for Decision Regional Technical Forum March 18, 2014.
Ductless Heat Pumps in Manufactured Homes with Zonal Electric Resistance Heat Adam Hadley Regional Technical Forum February 18, 2015.
Oregon Energy Star Homes Measure Update New Measure Proposal April 22nd,
SEEM Calibration for Multi-Family Buildings Regional Technical Forum September 18, 2012 Analysis Performed By Ben Larson, Jon Heller, Henry Odum, and Carmen.
UES Measure Sunsets Regional Technical Forum December 17, 2013.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Single Family Weatherization and HVAC UES Measures Regional Technical Forum July.
Residential and Commercial Storage Electric Resistance Water Heaters (Efficient Tanks) Mohit Singh-Chhabra Regional Technical Forum February 18, 2015.
Residential Clothes Washers and Dryers Technical Subcommittee Ryan Firestone & Christian Douglass Regional Technical Forum March 10, PM.
Grocery Measure: LEDs for Reach-In Display Cases Regional Technical Forum July 21 st, 2015 Mohit Singh-Chhabra.
Prescriptive Duct Sealing UES Measure Proposal Regional Technical Forum Subcommittee July 8, 2013.
Manufactured Homes Calibration: Existing and New Homes Mohit Singh-Chhabra & Josh Rushton RTF Update March 17, 2015.
Manufactured Homes Calibration: Existing and New Homes Mohit Singh-Chhabra & Josh Rushton RTF Update May 12, 2015.
Residential New Construction Montana House: UES Measure Update Adam Hadley Regional Technical Forum April 14, 2015.
Manufactured Homes Calibration: Existing and New Homes Mohit Singh-Chhabra & Josh Rushton RTF MH Calibration Subcommittee February 27, 2015.
Direction on Guidelines Savings Definition Path: CONTINUED Remaining Useful Life (RUL) and Measure Interaction Regional Technical Forum February 19, 2014.
New Measure Proposal Review and Prioritization Jennifer Anziano, Adam Hadley, Mohit Singh-Chhabra, Christian Douglass Regional Technical Forum February.
Manufactured Homes Calibration: Existing and New Homes Josh Rushton & Mohit Singh-Chhabra RTF Update June 16, 2015.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Single Family Weatherization and HVAC UES Measures Regional Technical Forum August.
1 NORTHWEST ENERGY EFFICIENCY ALLIANCE Creating a DHP UES Measure Ecotope, Inc. July 16, 2013.
Residential Single Family HVAC UES Measures Proven and Planning UES Measure Proposals Adam Hadley Regional Technical Forum December 16, 2014.
Grocery Measure: EC Motors for Display Cases Regional Technical Forum July 21 st, 2015 Mohit Singh-Chhabra.
Grocery Measure: EC Motors for Display Cases Regional Technical Forum June 16 th, 2015 Mohit Singh-Chhabra.
Washington Energy Star and Built Green Homes Measure Update New Measure Proposal August 12th,
RTF Management Update Jennifer Anziano Regional Technical Forum April 14, 2015.
Oregon ENERGY STAR Homes Measure Update Adam Hadley Regional Technical Forum March 17, 2015.
Residential Single Family and Manufactured Home Heat Pump Water Heaters Christian Douglass Regional Technical Forum 4/14/2015.
QC Follow-up for Single Family SEEM Calibration, HVAC UES Measures, and Weatherization Measures Adam Hadley Regional Technical Forum May 12, 2015.
Analysis of Weatherization Measures Options for Savings Methodology and Presentation of Costs from 6 th Plan Regional Technical Forum May 4 th, 2010.
RTF Delivery Verification Guidance Batch 1 Jennifer Anziano Regional Technical Forum May 12, 2015.
Path for Multi-Family (MF) Weatherization and NC Measures Christian Douglass 8/18/2015.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Single Family Weatherization and HVAC UES Measures Follow-up from August RTF.
SEEM Calibration: Phase II Single Family Heating Energy Regional Technical Forum September 17, 2013 Presented By: Josh Rushton and Adam Hadley Subcommittee.
Staff Updates Regional Technical Forum November 19, 2013.
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat Proven UES Measure Proposal Regional Technical Forum November 19, 2013.
Manufactured Homes Calibration: New Construction Regional Technical Forum September 22 nd, 2015 Mohit Singh-Chhabra.
Research Strategy Review: Advanced Power Strips MH HVAC Related Measures Jennifer Anziano RTF R&E Subcommittee August 6, 2015.
Residential Duct Insulation New Deemed Measure Proposal – A Second Look Regional Technical Forum May 4 th, 2010.
Goodbye, “Last Measure In” Hello, “Option X”? Staff Proposal for how to deal with the last measure in conundrum Regional Technical Forum October 15, 2013.
Implementer’s Group July 2015 RTF Meeting Debrief and Upcoming Meeting Prep July 29, 2015.
Implementer’s Group June 2015 RTF Meeting Debrief and Upcoming Meeting Prep June 23, 2015.
RTF Management Update Jennifer Anziano Regional Technical Forum February 18, 2015.
Guidelines Revisions Defining What RTF Means by “Savings” December 17,
SEEM Calibration for Multi-Family Buildings Regional Technical Forum September 18, 2012 Analysis Performed By Ben Larson, Jon Heller, Henry Odum, and Carmen.
Residential New SF Energy Star Homes Idaho and Montana UES Measure Updates: Energy Star Homes, DHP TCO Homes, and BOP2 Homes March 18 th, 2014.
Residential New SF Energy Star Homes UES Measure Update December 17th, 2013.
Implementer’s Group May 2015 Meeting Debrief and Upcoming Meeting Prep May 19, 2015.
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat Proven UES Measure Proposal Regional Technical Forum October 16, 2013.
ENERGY STAR and EcoRated Homes: Planning Estimates and Research Strategy Regional Technical Forum December 8 th, 2015 Josh Rushton & Mohit Singh-Chhabra.
Working Towards Better Savings Estimates for HVAC and Weatherization Measures Regional Technical Forum September 16, 2014.
ENERGY STAR and Eco-Rated Homes: Planning Estimates and Research Strategy Regional Technical Forum December 8 th, 2015 Josh Rushton & Mohit Singh-Chhabra.
Multifamily Homes: Calibration Update Regional Technical Forum December 8 th, 2015.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Manufactured Homes Weatherization UES Measures Regional Technical Forum December.
RTF Management Update Jennifer Anziano Regional Technical Forum August 18, 2015.
Residential Showerheads UES Update Ryan Firestone Regional Technical Forum October 20, 2015.
Idaho and Montana Residential Single Family New Construction Measures Mohit Singh-Chhabra Regional Technical Forum October 20 th, 2015.
RTF Management Update Jennifer Anziano Regional Technical Forum June 16, 2015.
Planning UES Measures: SF New Construction Heat Pump Upgrades (9.0 HSPF and VCHP) Heat Pump Commissioning Controls and Sizing Adam Hadley Regional Technical.
Planning UES Measures: Prescriptive Duct Sealing SF Performance-based Duct Sealing SF Performance-based Duct Sealing MH Adam Hadley & Josh Rushton Regional.
RTF Management Update Jennifer Anziano Regional Technical Forum July 21, 2015.
Implementer’s Group December Meeting Debrief and Upcoming Meeting Prep January 6, 2015.
RTF Management Update Jennifer Anziano Regional Technical Forum March 17, 2015.
Implementer’s Group October 2015 RTF Meeting Debrief and Upcoming Meeting Prep October 29, 2015.
RTF Management Updates Jennifer Light Regional Technical Forum February 17, 2016.
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat UES Measure Update Regional Technical Forum June 17, 2014.
Single Family New Construction Measure: Slab Insulation Mohit Singh-Chhabra Regional Technical Forum April 19 th, 2016.
Manufactured Homes: Heat Pump Related Measures Regional Technical Forum Presentation August 18 th, 2015.
Working Towards Better Savings Estimates for HVAC and Weatherization Measures Regional Technical Forum September 16, 2014.
Presentation transcript:

Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Manufactured Homes Weatherization UES Measures Regional Technical Forum June 16 th, 2015 Mohit Singh-Chhabra

Presentation Objective Approve MH weatherization measure analysis – Conducted by applying SEEM updates, RBSA calibration (phase 1 & 2) and measure interaction decisions – Approve measures with Electric Resistance Heat identifier as proven – Approve measures with heat pump identifier as planning CC&S research needs to be completed before proven measure with Heat Pump identifier can be developed – Research Strategy presented to the RTF on 3/15 Need to develop Research Strategy for manufactured homes heat pump calibration curve (within next two RTF meetings) 2

How We Got Here August ‘14: Savings calculation methodology addressing measure interaction approved by the RTF – Already applied to SF weatherization measures and approved August ‘14: Existing SF & MH cooling energy calibration approved by the RTF at the August ‘14 meeting – Simplified calibration, on-average thermostat setting December ‘14: MH weatherization analysis presented, RTF directed staff to compare modeled savings estimates with actual program data June ’15 (Today): Calibration curve for existing MH approved by the RTF 3

Measure Overview - 4

Measure Specification Update R-30 attic insulation only applicable to homes with adequate roof pitch – HUD certified, no less than 3:12 nominal pitch – This applies to attic insulation R0-R30, R11-R30 Pre-HUD certified homes will not have enough pitch to allow for R- 30 weatherization. The R0-R22 upgrade is applicable to these homes only. R19-R30 measure discontinued – R19 is the assumed cost effectiveness limit for insulation retrofits CAT consulted with experts (Bruce Manclark, Brady Peeks and Tom Hewes) to develop these measure specs 5

Measure Identifier Update New measure identifier: Electric Resistance Heat – This includes both eFAF and zonal heating systems – RBSA had very little evidence of primary zonal heat prevalence in MH – Zonal and eFAF heated homes likely have similar properties except duct systems 6

Methodology Overview Analysis follows a similar methodology as the SF weatherization measure analysis: RBSA informs measure baseline Define the Full Measure Package (FMP) to conduct RTF measure interaction guidance compliant energy savings analysis Apply RTF approved Phase 1 and Phase 2 calibration Apply RTF approved savings calculation methodology for measures with significant measure interaction (Option 3) 7

Measure Baseline RBSA MH homes simulated in SEEM as is to develop baseline – Each home simulated in all climate zones, similar SF analysis – Accurate representation of average regional UA value 8

Phase I Adjustment Factors 9

Phase II Adjustment Factors 10

Measure Interactions (Option 3) Full Measure Package (Defining efficiency levels) Attic: R-30 Floors: R-22 Windows: u-0.30 Infiltration: 0.35 ACHn Duct Tightness: PTCS Duct Insulation: R-8 Heat Pump HSPF: 9.0 HP CC&S: PTCS 11 Limit on Full Measure Package (Maximum efficiency of starting point) Attic: R-19 Floors: R-11 Windows: Double Pane Metal Frame Infiltration: 0.35 ACHn Duct Tightness: n/a Duct Insulation: Uninsulated Heat Pump HSPF: n/a HP CC&S: n/a Guidelines compliant Measure Interaction savings methodology implemented to calculate measure savings Follows similar methodology as the SF analysis.

Interpreting the Energy Savings Comparison Current Savings: – pre-RBSA calibration savings Note, these aren’t un-calibrated savings – Use LMI methodology – Currently on our books Proposed Savings: – Includes RBSA Phase 1 & 2 calibration – Includes measure interaction analysis “Option 3” 12

Energy Savings (kWh/sf): Attic Measures 13

Notes on Attic Savings Comparison Except the R0-R22 measure, we see a general trend of decrease in energy savings Attic R0-R22: – The current savings are for attic R0-R19 insulation upgrade – The proposed savings are based on pre-HUD homes only; not the case for current Attic R11-R30: – The current savings are for attic R19-R30 insulation upgrade 14

Energy Savings (kWh/sf): Floor Measures 15

Notes on Floor Insulation Savings Comparison General trend: decrease in per unit energy savings Savings floor insulation in HP heated homes in HZ 2, 3 are almost zero (sometimes negative) – For these measures, the calibrated FMP homes consume as much or slightly more energy than the calibrated RBSA homes – This is a function of the RBSA Phase 1 calibration curve (see backup slides) – Note: very few RBSA homes with a HP qualify for a floor insulation upgrade. i.e. measure unlikely to be common 16

Energy Savings (kWh/cfm50 red’n): Infiltration Reduction 17

Notes on Infiltration Energy Savings Comparison Savings decreased for measures due to – Updated SEEM infiltration algorithm See RTF presentation slide 13: Proven UES: Residential Single Family SEEM-affected UES Measures - Whiteboard Items - Adam Hadley (9/14)Proven UES: Residential Single Family SEEM-affected UES Measures - Whiteboard Items - Adam Hadley (9/14) – Effects of calibration, and measure interaction 18

Window Upgrades: Energy Savings Assumption Note: No HP home in RBSA with double pane windows. – Hence no data to model Double Pane to U30 window upgrade in HP homes. CAT estimated double pane upgrade measure savings using ratio of savings between double pane and single pane upgrade in electric resistance homes – Data available to calculate savings in HP homes for single pane to U30 upgrade. 19

Energy Savings (kWh/sf): Window Measures 20

Weatherization Cost Data RTF approved SIW cost data applied Proposed (and current) workbook uses the following as a proxy: – Insulation: SF cost data – Windows: SF and MF cost data – Infiltration: No change CAT received feedback that MH weatherization costs may be much higher than SF costs – Checked against, Idaho Power data. Costs similar to proposed assumption – Two out of state reports used for comparison WI Home Energy+ LI Program – showed significantly higher costs CO Low Income EE Retrofit Programs– showed similar costs to proposed assumption 21

Proposed and Current Measure Costs: Insulation (2006 $/sf) 22

Proposed and Current Measure Costs: Window Upgrades (2006 $/sf) 23

Proposed and Current Measure Costs: Infiltration Reduction No change in infiltration reduction costs – $0.68 per CFM50 reduction (In 2006$) 24

Measure Cost Effectiveness: Which measures are cost effective? Electric Resistance Heat: 25

Measure Cost Effectiveness: Which measures are cost effective? Heat Pump: 26

Delivery Verification Guidance Approved by the RTF on 05/

Decision Slide “I __________ move the RTF approve the Residential MH Weatherization UES measures as presented and: – Set the Category for measures with identifier Electric Resistance Heat to ‘Proven’; set the Status to ‘Active’; – Set the Category for measures with identifier Heat Pump to ‘Planning’; set the Status to ‘Under Review’; – Set the sunset date to May 31, 2020.” 28

Backup Slides 29

Measure Interactions - Option 3 30

Discussion: MH Calibration Phase I 31 Most Base case homes Most efficient homes

Discussion: MH Calibration Phase I

Discussion: MH Calibration Phase 1 (contd.)

Discussion: MH Calibration Phase I 34 R0-R22 R0-R30

Discussion: MH Calibration Phase 1 (contd.) 35 R0-R30 R0-R22