Engineer Training Cooler TJ8300 / TJ8500 Cooler. Engineer Training Cooler TJ8300 / TJ8500 Confidential 2 Introduction.

Slides:



Advertisements
Similar presentations
Engineer Training XL1200 Drying System. Engineer Training XL1200 Drying System Confidential 2 XL1200 Drying System.
Advertisements

Starter Question If you touch two objects that are the same temperature, why would one feel colder than the other?
Engineer Training UV Lamp Head TJ8300 / TJ8500 UV Lamp Head.
Engine Cooling And Lubrication
ADX 150 – Engine Repair ADX 170 – Climate Controls
Cooling System Get the engine up to optimum operating Temperature as quickly as possible and maintains it at that temperature. Controls the heat produced.
Thermostats The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees.
Basic Refrigeration Cycle
38GXC(Q)/40GXC(Q) Service Training Sizes 18 and 24K.
Section 16.3 Using Heat.
Engineer Training XL1500 Safety System. Engineer Training XL1500 Safety System Confidential 2 Standard Requirements Both the machine and the Safety System.
Engineer Training Troubleshooting TJ8300 / TJ8500 Troubleshooting.
Marine Engine Systems Merchant Marine Training Centre.
Cooling System For Gear Box Gear Box Cooler Air/Oil cooler fan driven Wash down Motor Gear Pump –Moves oil from gear box through cooler –Optional Oil.
Engineer Training Drum Heating TJ8300 / TJ8500 Drum Heating.
STEAM HEATING.
Hydronic Mechanical Controls
1 Engine Cooling Systems R. Bortignon. 2 Cooling Systems During the power stroke, temperatures of 1200°C or more are generated by the burning air/fuel.
Engineer Training UV Electrical Cabinet (16 and above) TJ8300 / TJ8500 UV Electrical Cabinet (Machines 16 and above)
1 HVACR316 - Piping Condensation Removal Refrigerant Traps Condensation Removal Refrigerant Traps.
Air Conditioning in tropical climates Presented by Ranjeet Kumar Nayak.
Engineer Training Machine New Features TJ8300 / TJ8500 Machine New Features.
Settings & Adjustments. Settings & Adjustments.
Air Conditioning Heating Refrigeration
Cooling Systems Purpose: to keep the engine at it’s most efficient operating temperature TOO HOT! TOO COLD! - poor lubrication - excessive heat - seizing.
FMTV COOLING SYSTEMS 4/23/2017.
Engineer Training UV Electrical Cabinet (1-15) TJ8300 / TJ8500 UV Electrical Cabinet (Machines 1-15)
Cooling System. 1. List the basic parts of a cooling system: -Thermostat -Fan -Water pump -Radiator -Ethelyne glycole -Shroud.
© Goodheart-Willcox Co., Inc. Permission granted to reproduce for educational use only.
Zoning Hydronic Systems. Zone Control Divides the Space to be Heated 1.Each with its own heating needs and control systems 2.There are several reasons.
Section 3 Using Heat.
Engineer Training Checking the Motor’s Rotation Direction TJ8300 / TJ8500 Checking the Motor’s Rotation Direction.
The Cooling System.
Thermal Control System. The Three Mechanisms of Heat Transfer Conduction - The transfer of heat through a solid –Interface Heat Exchangers –Cold plates.
Engineer Training Drying System, IR and Temp Control.
Insulators vs. Conductors Conductors transfer thermal energy rapidly (metals) Insulators reduce the transfer of thermal energy (wood, foam) Insulation.
The Cooling System (Reasons for)
Chapter 39 Cooling System Fundamentals.
Using Heat Part 2. Science Journal Entry 32 Explain the advantages and disadvantages of thermal expansion.
7 A/C System Components, Operation, and Service.
Cooling System Get the engine up to optimum operating Temperature as quickly as possible and maintains it at that temperature. Controls the heat produced.
Manoj kumar 2009JE0406 Mining machinery engineering.
MVD COOLING STATUS COOLING PLANT: -UPDATE of THE HYDRAULIC SYSTEM -INTEGRATION OF THE MVD COOLING CIRCUIT PATHS INSIDE THE PANDA AREA -DEFINITION OF THE.
Engine Cooling Systems
Automotive Engines Theory and Servicing
Fixed Orifice Tube Cycling Clutch System (FOTCC)
Fixed Orifice Tube Cycling Clutch System (FOTCC)
Heat Transfer and Refrigeration Cycle
Automotive Heating And Air Conditioning
Fan Coil Controller FC/S 1.1
Engine Lubrication Systems
. Level 3 Air Conditioning Inspections for Buildings
How to Draw a Systems Diagram
The Engine Cooling System
Heat Transfer and Refrigeration Cycle
Fixed Orifice Tube Cycling Clutch System (FOTCC)
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
Heat Transfer and Refrigeration Cycle
Heating Ventilating and Air Conditioning
Refrigeration Basics By: Mohamed Iqbal Pallipurath.
ME390 Automotive Mechanics
Cooling System Get the engine up to optimum operating Temperature as quickly as possible and maintains it at that temperature. Controls the heat produced.
The Refrigeration Cycle (Air Conditioners)
Bell work Predict whether leaving the refrigerator door open on a hot summer day will help to cool the kitchen.
SB Packing Automatic Downpuller Power Unit
Auto Upkeep Basic Car Care, Maintenance, and Repair (2nd Edition)
______________ Combustion Engine
By: JAGDEEP SANGWAN Refrigeration Basics 101.
Cooling System Get the engine up to optimum operating Temperature as quickly as possible and maintains it at that temperature. Controls the heat produced.
Presentation transcript:

Engineer Training Cooler TJ8300 / TJ8500 Cooler

Engineer Training Cooler TJ8300 / TJ8500 Confidential 2 Introduction

Engineer Training Cooler TJ8300 / TJ8500 Confidential 3 Location Located inside the collecting table

Engineer Training Cooler TJ8300 / TJ8500 Confidential 4 General Description  The cooler is located inside the collecting table.  The cooler’s function is to cool the water that flows through the UV lamp head.  The ambient temperature should be 15°C - 35°C.  The water circulates through the UV lamp head and the cooler.  The water flow pressure is bar.  Within the cooler, the distilled water flows from the water container, through the radiator, which cools it, and then is pumped towards the UV lamp head.

Engineer Training Cooler TJ8300 / TJ8500 Confidential 5 General description (Cont.)  The fan in the cooler removes the heat.  The water temperature must be below 70°C. Otherwise, the lamp will be turned off.

Engineer Training Cooler TJ8300 / TJ8500 Confidential 6 Cooler Unit Components The cooler unit includes:  Water container  Two Radiators  Water pump  Water pipes  Temperature sensor  Water filter  Cooler panel

Engineer Training Cooler TJ8300 / TJ8500 Confidential 7 Water Container Water level sensor50 lit water container

Engineer Training Cooler TJ8300 / TJ8500 Confidential 8 Water Container (Cont.)  The water container contains 50 liters of distilled water with 0.5% of corrosion inhibitor and 1 unit of microtreat.  The water circulates through the cooler and the UV lamp head.  The purpose of the water (float) sensor is to alert the system if the water level is low.  If the water reaches the low (threshold) level, the system turns off the lamp power. Corrosion inhibitor

Engineer Training Cooler TJ8300 / TJ8500 Confidential 9 Radiators  The purpose of the radiators is to cool down the warm water that returns from the UV lamp head.  The fan removes the heat from the cooler unit.

Engineer Training Cooler TJ8300 / TJ8500 Confidential 10 Water Pump Thermal Switch Water Pump

Engineer Training Cooler TJ8300 / TJ8500 Confidential 11 Water Pump (Cont.)  The pump circulates the water through the UV lamp head and the container, via the two radiators.  The thermal switch is set to 70°C and protects the system against high temperatures. If the temperature of the inlet water (into the radiators) reaches 70°C, the system turns off the UV lamp.  The water flow pressure is bar.

Engineer Training Cooler TJ8300 / TJ8500 Confidential 12 Water Tubes Two water tubes are connected between the UV lamp head and the cooler unit. Red mark: The tube carries heated water from the UV lamp head to the cooler unit. Blue mark: The tube carries cold water from the cooler unit to the UV lamp head.

Engineer Training Cooler TJ8300 / TJ8500 Confidential 13 Temperature Sensor The temperature sensor measures the temperature of the output water that flows to the UV lamp head. Temperature Sensor

Engineer Training Cooler TJ8300 / TJ8500 Confidential 14 Water Filter The water filter prevents dirt from entering into the radiators. Water Filter

Engineer Training Cooler TJ8300 / TJ8500 Confidential 15 Cooler Panel Water Level Water level Output water temperature Pump pressure