Impedance Imaging for Breast Cancer Diagnosis Tzu-Jen Kao 1, Ning Liu 3, Hongjun Xia 1, Bong Seok Kim 1, David Isaacson 2, Gary J. Saulnier 3, Jonathan.

Slides:



Advertisements
Similar presentations
Project Lead the Way An Orientation American High School.
Advertisements

ELEN 3371 Electromagnetics Fall Lecture 6: Maxwell’s Equations Instructor: Dr. Gleb V. Tcheslavski Contact: Office.
THE COMPLETE ELECTRODE MODEL FOR IMAGING AND ELECTRODE CONTACT COMPENSATION IN ELECTRICAL IMPEDANCE TOMOGRAPHY G. Boverman 1, B.S. Kim 1, T.-J. Kao 3,
Cell phones and brain cancer: Unlocking the controversy? Faina Linkov, PhD Assistant Professor, University of Pittsburgh Cancer Institute.
Millimeter Wave Sensor: An Overview
The Improved 3D Matlab_based FDFD Model and Its Application Qiuzhao Dong(NU), Carey Rapapport(NU) (contact: This.
WRSTA, 13 August, 2006 Rough Sets in Hybrid Intelligent Systems For Breast Cancer Detection By Aboul Ella Hassanien Cairo University, Faculty of Computer.
1 Electrical Impedance Tomography with Tomosynthesis for Breast Cancer Detection Jonathan Newell Rensselaer Polytechnic Institute With: David Isaacson.
Department of Electrical and Computer Engineering Texas A&M University College Station, TX Abstract 4-Level Elevator Controller Lessons Learned.
Modeling The quadratic integrate and fire follows from a reduced form (1) where F(V) is a voltage dependant function which aims to capture the voltage.
Proton Imaging and Fighting Cancer
Accuracy of PCA for Cancer detection applied to micro array data by Nasser Abbasi Project supervisor: Dr C.H. Lee Mathematics department, CSUF.
Background on: Breast Cancer, X-Ray and MRI Mammography
Biomedical Engineering Overview
Motivation “Every three minutes a woman is diagnosed with Breast cancer” (American Cancer Society, “Detailed Guide: Breast Cancer,” 2006) Explore the use.
1 Antennas: from Theory to Practice 1. Basics of Electromagnetics Yi HUANG Department of Electrical Engineering & Electronics The University of Liverpool.
Kunal Mitra Professor, Mechanical and Aerospace Engineering Department Director- Biomedical Engineering Program Florida Institute of Technology, Melbourne,
Magnetic Resonance Electrical Impedance Mammography (MREIM) A new approach to breast cancer imaging Maria Kallergi, 1 John J. Heine, 2 and Ernest Wollin.
Dr. Yaseen Hayajneh Radiology Services Yaseen Hayajneh RN, MPH, PhD.
Articulating Confocal Endoscope for Imaging Cancers in vivo This work is supported in part by the Center for Subsurface Sensing and Imaging Systems, under.
Parameter selection in prostate IMRT Renzhi Lu, Richard J. Radke 1, Andrew Jackson 2 Rensselaer Polytechnic Institute 1,Memorial Sloan-Kettering Cancer.
Magnetoencephalography (MEG)
Chapter 5 Engineering Tools for Electrical and Computer Engineers.
1 Development a Portable Device for Multi-Channel Impedance Measurement in Dielectrophoresis-chip Chairman : Dr. Hung-Chi Yang Presenter : Ping-Yang Liao.
Computed Tomography Physics, Instrumentation, and Imaging
The above shows the implementation of the software used to interface with the data acquisition hardware. Inputs for each encoder and the APD detector were.
Presenter: Chuan Li Yang Dept of Electronic and Electrical Engineering.
Improving the object depth localization in fluorescence diffuse optical tomography in an axial outward imaging geometry using a geometric sensitivity difference.
Surface Reconstruction of Blood Vessels from 3D Fluorescence Microscopy Images Abstract This project aims at doing a surface reconstruction of 3D fluorescence.
Regional admittivity spectra with Tomosynthesis images for breast cancer detection Tzu-Jen. Kao 1, G. Boverman 1, J.C. Newell 1, D. Isaacson 2, G.J. Saulnier.
Terahertz Applications for Detection of Explosives Jian Chen, Yunqing Chen, Hongwei Zhao, X.-C. Zhang Center for Terahertz Research, Rensselaer Polytechnic.
Introduction Magnetic resonance (MR) imaging is recognised as offering potential benefits in the delineation of target volumes for radiotherapy (RT). For.
A Front End and Readout System for PET Overview: –Requirements –Block Diagram –Details William W. Moses Lawrence Berkeley National Laboratory Department.
MRI image validation using MRI simulation Emily Koch CIS II April 10, 2001.
School of Biomedical Engineering, Science & Health Systems V 2.0 SD [020204] Impedance Cardiography for Non-invasive.
BioE153:Imaging As An Inverse Problem Grant T. Gullberg
Engineering Better Brain Implants for the Future of Medicine Patrick J. Rousche, Ph.D. Bioengineering, and co-PI Laxman Saggere, Ph.D. Mechancial Engineering.
Digital Radiology Techniques used in imaging. Why is technology so important? Prenatal Diagnosis and Management of Conjoined Fetuses.
Suppression of the eyelash artifact in ultra-widefield retinal images Vanessa Ortiz-Rivera – Dr. Badrinath Roysam, Advisor –
Radiology started with simple traditional x-ray technology.
Wang Chen, Dr. Miriam Leeser, Dr. Carey Rappaport Goal Speedup 3D Finite-Difference Time-Domain.
Anthropomorphic Liver Phantom for CT and Ultrasound Katelyn Herbert Advisor: Dr. Robert Galloway (BME) Department of Biomedical Engineering, Vanderbilt.
Visualization of Tumors in 4D Medical CT Datasets Visualization of Tumors in 4D Medical CT Datasets Burak Erem 1, David Kaeli 1, Dana Brooks 1, George.
ACT4: A High-Precision, Multi-frequency Electrical Impedance Tomograph. Chandana Tamma 1, Ning Liu 1, G.J. Saulnier 1 J.C. Newell 2 and D. Isaacson 3.
Presenter : Yu-Chun Hua Presenter : Yu-Chun Hua Adviser : Dr. Ji-Jer Huang Adviser : Dr. Ji-Jer Huang Date : Date :
Your text would go here. Introduction to Glass OCT Technology Google Glass Optical Coherence Tomography (OCT) is a feature of Glass that is revolutionizing.
Introduction In positron emission tomography (PET), each line of response (LOR) has a different sensitivity due to the scanner's geometry and detector.
Imaging HIFU Lesions Using Ultrasound Andrew Draudt and Robin Cleveland Department of Aerospace and Mechanical Engineering, Boston University, Boston,
CardioInspect Diagnostic and Monitoring Systems
Mammographic image analysis for breast cancer detection using complex wavelet transforms and morphological operators.
1 Introduction to Computer Graphics with WebGL Ed Angel Professor Emeritus of Computer Science Founding Director, Arts, Research, Technology and Science.
BME 353 – BIOMEDICAL MEASUREMENTS AND INSTRUMENTATION MEASUREMENT PRINCIPLES.
Hemodynamically Constrained Dynamic Diffuse Optical Tomography Under Mammographic Compression Eleonora Vidolova 1, Dana Brooks 1, Eric Miller 2, Stefan.
Non-invasive fetal electrocardiogram measurements Adviser :蔡亮宙 Student ;蔡政宏.
The current density at each interfacial layer. The forward voltage is continuous at every point inside the body. A Layered Model for Breasts in Electrical.
Take Up.  Arthroscopes are a surgical tool that allow surgeons to literally see within a patient’s joints without having to surgically open the patient.
Fast and parallel implementation of Image Processing Algorithm using CUDA Technology On GPU Hardware Neha Patil Badrinath Roysam Department of Electrical.
By David Tse Mentor: Andreas H. Hielscher, Ph.D Columbia University Biomedical Engineering Department 500 West 120th Street ET351 Mudd Bldg., MC8904 New.
X-rays By: Jacob, Akram, Cameron Science biophysics ISP.
The magnetic field is then detected by sensing coils. MIT is sensitive to all three passive electromagnetic properties: conductivity, permittivity and.
Hanyang University Antennas & RF Devices Lab. ANTENNA THEORY ANALYSIS AND DESIGN Prof. Jaehoon Choi Dept. of Electronics and Computer Engineering
Electrical Resistivity of K12/TRb Tumors vs. Normal Liver Tissue
T. E. Dyhoum1, D. Lesnic 1 and R. G. Aykroyd 2
Excitation based cone-beam X-ray luminescence tomography of nanophosphors with different concentrations Peng Gao*, Huangsheng Pu*, Junyan Rong, Wenli Zhang,
ELEC 401 MICROWAVE ELECTRONICS Lecture 3
ELEC 401 MICROWAVE ELECTRONICS Lecture 3
Hyonyoung Han, Min-Joon Kim, and Jung Kim
Reza Firoozabadi, Eric L. Miller, Carey M. Rappaport and Ann W
Lattice (bounce) diagram
Theoretical Background Challenges and Significance
Presentation transcript:

Impedance Imaging for Breast Cancer Diagnosis Tzu-Jen Kao 1, Ning Liu 3, Hongjun Xia 1, Bong Seok Kim 1, David Isaacson 2, Gary J. Saulnier 3, Jonathan C. Newell 1 1 Departments of Biomedical Engineering, 2 Mathematical Sciences 3 Department of Electrical, Computer and Systems Engineering Rensselaer Polytechnic Institute Introduction: The long-term goal of this project is to develop Electrical Impedance Tomography (EIT) technology to improve the diagnosis of breast cancer. Breast Cancer is responsible for over 40,000 deaths annually among women in the United Stated. Early detection of breast cancer improves the chances that it can be treated successfully. Also, improved detection techniques may be able to reduce the number of biopsies that are performed. Even using combined diagnostic techniques, such as mammography, MRI, clinical breast examination, only % of the biopsies that are performed actually reveal cancer [4]. Electrical Impedance Tomography, also called Electrical Impedance Imaging, is a non-invasive technique used to image the electrical conductivity and permittivity within a body from measurements taken on the body surface [5]. Small electric currents are passed through the body using electrodes attached to the skin; the resulting voltages are then measured and used by mathematical algorithms to reconstruct the values of the electrical conductivity and permittivity within the body. It has been known for some time that breast tumors have a significantly higher conductivity and permittivity than surrounding normal tissue. Hence, by forming images of the electrical conductivity of the breast, tumors may be detected and differentiated from normal tissue. EIT does not use ionizing radiation and employs relatively low-cost instrumentation, making it less expensive and/or safer than x-ray mammography, MRI and CT. Future Plans: We are presently testing the ACT 4 hardware and implementing the initial version of the system software and firmware. Over the next few weeks we expect to begin collecting complete data sets and testing the instrument performance. Initial testing will use laboratory test phantoms with conductivity similar to that of the human body. Once the instrument is fully tested and its performance characterized, it will be used to study breast cancer patients at Massachusetts General Hospital. The study, involving a small number of patients who will be undergoing biopsies, will establish the ability of EIT to detect cancer by directly comparing EIT results with biopsy results. References Publications Acknowledging NSF Support: 1. Ning Liu, Gary J. Saulnier, J.C. Newell, D. Isaacson and T-J Kao. “ ACT4: A High-Precision, Multi-frequency Electrical Impedance Tomography ” Conference on Biomedical Applications of Electrical Impedance Tomography, University College London, June 22-24th, Hongjun Xia, A. S. Ross E. Brevdo, T-J Kao, Ning Liu, B. S. Kim, J.C. Newell, G. J. Saulnier and D. Isaacson. “ The Application software of ACT4. ” Conference on Biomedical Applications of Electrical Impedance Tomography, University College London, June 22-24th, Choi, M.H., T-J Kao, D. Isaacson, G.J. Saulnier and J.C. Newell. “ A Simplified Model of a Mammography Geometry for Breast Cancer Imaging with Electrical Impedance Tomography ” Proc. IEEE-EMBS Conf. 26, In Press Others: 4. American Cancer Society, 5. M. Cheney, D. Isaacson, Newell, S. Simske, and J. Goble, “ NOSER: An Algorithm for Solving the Inverse Conductivity Problem ” Int.. J. Imag. Syst. Tech., vol. 2, pp , Jossinet, J. and M. Schmitt. “ A review of Parameters for Bioelectrical characterization of Breast Tissue ” Ann. NY Acad. Sci. Vol. 873:30-41, Cheng, K-S., D. Isaacson, J.C. Newell and D.G. Gisser. “ Electrode Models for Electric Current Computed Tomography ” IEEE Trans. Biomed. Eng. 36: , The ACT 4 system is hosted by a Pentium-based personal computer. Through the computer, the operator is able to control the hardware, display and manipulate images and manage the information database. The user interface software is designed to be used in both clinical and laboratory environments and is implemented as a window-style program coded in Visual C++. The interface to allow access to low-level hardware functions will be available for laboratory/experimental use. A simplified interface offering only the functions needed for collecting patient data will be available for clinical use. Contact Info: Jonathan Newell, Ph. D. Professor of Biomedical Engineering Rensselaer Polytechnic Institute Web site: Eighth St. Troy, NY Phone : FAX : Hardware and Software: [1, 2] The ACT 4 hardware and software supports 64 electrodes that will produce 3-D images of conductivity and permittivity in real time using applied excitations with frequencies between 1 KHz and 1 MHz. It will be able to apply arbitrary patterns of voltage or currents while measuring the resulting currents and voltages, respectively. The operator will be able to select various combinations of image rate and measurement precision, including real-time operation to visualization cardiac-frequency events. To support a high-speed, high-precision, multi-channel instrument, we designed a distributed digital system, including a computer, digital signal processors (DSPs) and field-programmable gate arrays (FPGAs). The computer provides a user interface to control the instrument and to display the results for analysis. Four DSPs are working in parallel to implement the real-time reconstruction algorithm. We use FPGAs mainly to implement the signal generation, voltmeter and control for the ACT 4 analog circuits. FPGAs are also used to implement the interface between multiple channels through a VME-64x backplane, and between the computer and the instrument. Data Collection Hardware Control Data Management BMP Files Patient Information Import Export Image Display System Configuration Reconstruction Algorithm Block Diagram of Software Structure Reconstructed Images: Reconstruction Algorithms: Reconstructing an EIT image involves solving the inverse problem of determining the conductivity and permittivity distribution within a body that produces the observed relationship between the voltage and current at the surface. The problem is ill-posed, meaning that large changes in the conductivity and permittivity can produce only small changes at the surface. This ill-posedness makes the reconstruction problem more difficult and results in the need for very high-precision instrumentation. In the low frequency limit ( ω = 0 ) Maxwell’s equations reduce to Therefore, in this case Where U denotes the electrical potential or voltage throughout the interior of the body. Hence in the low frequency limit we have that the voltage inside the body, B, satisfies. On the body’s surface, S, one has. Here υ denotes the outward pointing unit normal vector to the body B on the surface S, and j denotes the applied current density on the surface. V denotes the measured voltage on the surface. The following steps are used to reconstruct an approximation to the conductivity σ at low frequencies: 1.Introducing a guess for the conductivity, σ 0. 2.Relating the potentials or fields on the surface S to the electrical tissue properties and field inside the body B by the identity Here the subscript 0 denotes fields due to the conductivity σ 0. The superscripts denote the fields that result from different current densities. 3. Apply an electrode model [7] relating currents and voltages on electrodes labeled with the subscript l = 1, …,L into the above exact relation. Use the notation δσ = σ - σ 0 and the approximation U k = U 0 k + O(δσ) to obtain the equations relating measured current voltages to moments of the unknown conductivity 4. Measure and compute the components of the “data” matrix D. 5. Choose a basis of functions for approximation δσ by 6. Display σ = δσ + σ 0 3D Image in 2D sequence (Layer 1 ~ Layer 8, thickness: 6.25 mm each ) Agar target is located 6 mm away from the electrode array Model of the mammogram geometry: Experimental Design: [3] Size of Electrode Array: 5 x 5 cm Dim. of the box : 5 cm x 5 cm x 5 cm Size of Electrode: 1.0 x 1.0 cm Gap between Electrodes: 2 mm Conductivity σ 0 = S/m Agar Target size: 5 mm cube Conductivity σ = S/m The Agar Target with Electrode Array Agar TargetThe 4x4 Electrode Array Solid line: reconstructed voxel conductivity Dotted line: ideal computed conductivity of voxel Importance of this work: The reconstruction of conductivity images in a mammogram geometry will provide a foundation for the comparison of EIT as a breast cancer detection tool with the X-ray mammography. This work is supported in part by CenSSIS, the Center for Subsurface Sensing and Imaging Systems, under the Engineering Research Centers Program of the National Science Foundation (Award Number EEC ). This work is supported in part by NIBIB, the National Institute of Biomedical Imaging and Bioengineering under Grant Number R01-EB State of the art & dummy load test: The spectral characteristics of excised breast tissue provided by Jossinet & Schmitt [6] The results suggest that EIT is a promising modality to image the breast for malignancies.